Amendment 1 - Appliances couplers for household and similar general purposes - Part 1: General requirements

Amendement 1 - Connecteurs pour usages domestiques et usages généraux analogues - Partie 1: Prescriptions générales

General Information

Status
Published
Publication Date
28-Aug-2007
Technical Committee
Current Stage
DELPUB - Deleted Publication
Completion Date
24-Jun-2015
Ref Project

Relations

Buy Standard

Standard
IEC 60320-1:2001/AMD1:2007 - Amendment 1 - Appliances couplers for household and similar general purposes - Part 1: General requirements Released:8/29/2007 Isbn:2831892937
English and French language
17 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 60320-1
Edition 2.0 2007-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Appliances couplers for household and similar general purposes –
Part 1: General requirements
Connecteurs pour usages domestiques et usages généraux analogues –
Partie 1: Prescriptions générales

IEC 60320-1 A1:2007
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60320-1
Edition 2.0 2007-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 1
AMENDEMENT 1
Appliances couplers for household and similar general purposes –
Part 1: General requirements
Connecteurs pour usages domestiques et usages généraux analogues –
Partie 1: Prescriptions générales

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
J
CODE PRIX
ICS 29.120.30 ISBN 2-8318-9293-7

– 2 – 60320-1 Amend. 1 © IEC:2007
FOREWORD
This amendment has been prepared by subcommittee 23G: Appliance couplers, of IEC
technical committee 23: Electrical accessories.
The text of this amendment is based on the following documents:
FDIS Report on voting
23G/273/FDIS 23G/274/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Replace the page reference for standard sheet C1 – C27 by
Standard sheets C1 – C27……………………………………………………………………………. 103

Page 13
2 Normative references
Add the following IEC standard:
IEC 60999-1:1999, Connecting devices – Electrical copper conductors – Safety requirements
for screw-type and screwless-type clamping units – Part 1: General requirements and
2 2
particular requirements for clamping units for conductors from 0,2 mm up to 35 mm
(included)
Page 25
8 Marking
8.1
60320-1 Amend. 1 © IEC:2007 – 3 –
Add the following new dash item:
– the marking as specified in Subclause 7.5 of IEC 60999-1 to identify the type of
conductors suitable for screwless terminals.
Page 29
9 Dimensions and compatibility
9.6
Replace, on page 35, the first and second paragraphs of Subclause 9.6 by the following text:
Non-standardized appliance couplers which do not refer to the dimensions specified in the
standard sheets are acceptable, but only if they provide a technical advantage and do not
adversely affect the purpose and safety of appliance couplers complying with the standard
sheets, especially with regard to interchangeability and non-interchangeability.
Non-standardized appliance couplers, however, shall comply with all other requirements of
this standard as far as they reasonably apply.
Change “Note 1” to “Note”.
Insert after the Note the following normative text:
Small deviations from the dimensions as specified in the standard sheets, which give the
impression of a standardized coupler and lead to confusion with standardized appliance
couplers, are not allowed.
Change Notes 2 and 3 into normative text.
Add, at the end of the subclause, the following new paragraph:
It shall not be possible within a given system for a connector and associated appliance inlet to
make improper connections other than the intended position or partial connections causing
deformation which can impair the further use of the appliance.
Compliance is checked by manual test.
Page 37
12 Terminals and terminations
Renumber the first three paragraphs as “12.1 General”.
Delete the existing subtitle “12.1 General”.
Delete existing Subclauses 12.1.1, 12.1.2 and 12.1.3.
Add the following new Subclause 12.2:
12.2 Rewirable connectors shall be provided with clamping units according to IEC 60999-1.

– 4 – 60320-1 Amend. 1 © IEC:2007
Non-rewirable connectors shall be provided with soldered, welded, crimped or equally
effective screwless connections, which shall not allow the possibility to disconnect the
conductor. Screwed connections shall not be used.
The end of a stranded conductor shall not be consolidated by soft soldering at places where
the conductor is subject to contact pressure unless the clamping means is designed so as to
obviate the risk of a bad contact due to cold flow of the solder.
Replace the existing subtitle “Screw-type terminals” with the following new Subclause 12.3:
12.3 Rewirable connectors with a rated current not exceeding 16 A shall have a rated
connecting capacity of 1,5 mm according to IEC 60999-1.
Compliance is checked by the relevant tests of IEC 60999-1.
Delete all subclauses from 12.2.1 to 12.2.12.
Add the following new subclauses:
12.4 Clamping units shall be so fixed or located within the connector that when operated,
the clamping units shall not work loose and creepage distances and clearances shall not be
reduced below the values specified.
NOTE 1 These requirements do not imply the terminals should be so designed that their rotation or displacement
is prevented, but any movement should be sufficiently limited so as to prevent non-compliance with this standard.
NOTE 2 The use of sealing compound or resin is considered to be sufficient for preventing a terminal from working
loose, provided that
− the sealing compound or resin is not subject to stress during normal use, and
− the effectiveness of the sealing compound or resin is not impaired by temperatures attained by the terminal
under the most unfavourable conditions as specified in this standard.
Compliance is checked by the relevant tests of IEC 60999-1.
12.5 Clamping units for earthing conductors shall be of the same size as the corresponding
terminals for the current carrying conductors.
Compliance is checked by inspection.
Page 53
15 Insulation resistance and electric strength
15.2
Replace, on Page 55, item f) by:
f) for rewirable connectors, between any metal part of the cord anchorage, excluding
+0
clamping screws, and a metal rod, of the maximum diameter of the cord mm,
−1
inserted in its place.
Replace the second and third paragraphs after Table 2 by the following text:

60320-1 Amend. 1 © IEC:2007 – 5 –
The term "body" used in items a) and c) above includes all accessible metal parts, fixing
screws, external assembly screws and the like and a metal foil in contact with the outer
surface of external parts of insulating material, in item c) including the engagement face of
connectors. The metal foil is wrapped round the outer surface of external parts of insulating
material; however, it is not pressed into openings.
15.3
Replace the second and third paragraphs by:
The value of the test voltage is 3 000 V ± 60 V when applied between the parts and the body
specified in items a) and c) and 1 500 V ± 60 V in all other cases. Initially, not more than half
the prescribed voltage is applied, and then it is raised rapidly to the full value.
Page 57
16 Forces necessary to insert and to withdraw the connector
16.2 Verification of the maximum withdrawal force
Replace, in the first paragraph, “figure 11” by “Figure 12".
Page 61
18 Resistance to heating of appliance couplers for hot conditions or very hot
conditions
18.1
Replace the second paragraph by:
Connectors for hot and very hot conditions shall be so constructed that the body shall not
allow separation from the front during the tests and the insulation of the core of the cord shall
not be subjected to excessive heating.
18.2
Replace the paragraph “After removal from the apparatus … appliance inlet 10 times” by:
After removal from the test apparatus, one of the connectors shall be subjected to the test of
23.7 within 15 s. The connectors are then allowed to cool down to approximately ambient air
temperature and are inserted into and withdrawn from the appliance inlet 10 times.
Page 63
19 Breaking capacity
Replace the third paragraph by:
The connector is mounted in an appropriate test apparatus, which incorporates an appliance
inlet having polished, hardened steel pins, and dimensions as specified in the relevant

– 6 – 60320-1 Amend. 1 © IEC:2007
standard sheet. The ends of the pins shall be rounded for rectangular pins and hemispherical
for round pins as shown in the standard sheets.
Add the following new paragraph after the fourth paragraph:
The test apparatus shall be designed and adjusted so as to simulate as far as possible
disconnection in normal use.
Page 67
21 Temperature rise
Replace the third paragraph by the following:
Rewirable connectors are fitted with polyvinyl chloride insulated cords having a length of 1 m
2 2
and a cross-sectional area of 1 mm for 10 A connectors and 1,5 mm for 16 A connectors.
Screws of clamping units, if any, are tightened with the torque values specified in the
appropriate column of Table 8 of 25.1.
Non-rewirable connectors are tested with the cord as delivered.
22 Cords and their connection
22.1
Replace the third paragraph by the following:
Non-rewirable connectors shall be provided with a type of cord complying with the standard
indicated in Table 4 for the type of connector and, in addition, the cord shall have a cross-
sectional area not less than that specified in Table 4.
22.3
Replace, on Page 71, the paragraph after Table 5 by the following:
Conductors of the cord of rewirable connectors are introduced into the clamping units, and the
screws of clamping units, if any, are tightened just sufficiently to prevent the conductors from
easily changing their position.
Replace the third paragraph before the Note by the following:
After the tests, the cord shall not have been displaced by more than 2 mm. For rewirable
connectors, the ends of the conductors shall not have moved noticeably in the terminals; for
non-rewirable connectors, there shall be no break in the electrical connections. A visual
inspection is made to ensure no undue twisting of the conductors where they are connected to
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.