Household and similar electrical appliances - Safety - Part 2-101: Particular requirements for vaporizers

Deals with the safety of electric vaporizers for household and similar purposes, their rated voltage being not more than 250 V. This consolidated version consists of the first edition (2002) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.

Appareils électrodomestiques et analogues - Sécurité - Partie 2-101: Règles particulières pour les vaporisateurs

Deals with the safety of electric vaporizers for household and similar purposes, their rated voltage being not more than 250 V.  Cette version consolidée comprend la première édition (2002) et son amendement 1 (2008). Il n'est donc pas nécessaire de commander l'amendement avec cette publication.

General Information

Status
Published
Publication Date
14-Jul-2008
Current Stage
PPUB - Publication issued
Start Date
15-Jul-2008
Completion Date
15-Jul-2008
Ref Project

Buy Standard

Standard
IEC 60335-2-101:2002+AMD1:2008 CSV - Household and similar electrical appliances - Safety - Part 2-101: Particular requirements for vaporizers
English and French language
25 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

IEC 60335-2-101
Edition 1.1 2008-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –
Part 2-101: Particular requirements for vaporizers

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-101: Règles particulières pour les vaporisateurs

IEC 60335-2-101:2002+A1:2008

---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2008 IEC, Geneva, Switzerland

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch

About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00


A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00

---------------------- Page: 2 ----------------------
IEC 60335-2-101
Edition 1.1 2008-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –
Part 2-101: Particular requirements for vaporizers

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-101: Règles particulières pour les vaporisateurs

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CD
CODE PRIX
ICS 13.120; 97.030 ISBN 2-8318-9764-5
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 3 ----------------------
– 2 – 60335-2-101 © IEC:2002+A1:2008
CONTENTS
FOREWORD.3
INTRODUCTION.5

1 Scope.6
2 Normative references.6
3 Definitions.6
4 General requirement.7
5 General conditions for the tests .7
6 Classification.7
7 Marking and instructions.7
8 Protection against access to live parts.7
9 Starting of motor-operated appliances .8
10 Power input and current .8
11 Heating.8
12 Void.8
13 Leakage current and electric strength at operating temperature.8
14 Transient overvoltages .9
15 Moisture resistance.9
16 Leakage current and electric strength.9
17 Overload protection of transformers and associated circuits .9
18 Endurance.9
19 Abnormal operation.9
20 Stability and mechanical hazards .10
21 Mechanical strength.10
22 Construction.10
23 Internal wiring.11
24 Components.11
25 Supply connection and external flexible cords .11
26 Terminals for external conductors.11
27 Provision for earthing .11
28 Screws and connections .11
29 Clearances, creepage distances and solid insulation .11
30 Resistance to heat and fire.11
31 Resistance to rusting.12
32 Radiation, toxicity and similar hazards.12

13
Annexes .

13
Bibliography.

---------------------- Page: 4 ----------------------
60335-2-101 © IEC:2002+A1:2008 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
–––––––––––––
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –

Part 2-101: Particular requirements for vaporizers


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by IEC technical committee 61:
Safety of household and similar electrical appliances.
It forms the first edition of IEC 60335-2-101.
This consolidated version of IEC 60335-2-101 consists of the first edition (2002) [documents
61/2136/FDIS and 61/2161/RVD] and its amendment 1 (2008) [documents 61/3558/FDIS and
61/3604/RVD].
The technical content is therefore identical to the base edition and its amendment and has
been prepared for user convenience.
It bears the edition number 1.1.
A vertical line in the margin shows where the base publication has been modified by
amendment 1.

---------------------- Page: 5 ----------------------
– 4 – 60335-2-101 © IEC:2002+A1:2008
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fourth edition (2001) of that standard.
NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.
This part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for electric vaporizers.
When a particular subclause of Part 1 is not mentioned in this part 2, that subclause applies
as far as is reasonable. When this standard states "addition", "modification", or "replacement",
the relevant text in Part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional annexes are lettered AA, BB, etc.

NOTE 3 The following print types are used:
– requirements: in roman type;
– test specifications: in italic type;
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the
associated noun are also in bold.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date,
the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

NOTE 4 The attention of National Committees is drawn to the fact that equipment manufacturers and testing
organizations may need a transitional period following publication of a new, amended or revised IEC publication in
which to make products in accordance with the new requirements and to equip themselves for conducting new or
revised tests.
It is the recommendation of the committee that the content of the amendment 1 be adopted for implementation
nationally not earlier than 12 months or later than 36 months from the date of publication.

---------------------- Page: 6 ----------------------
60335-2-101 © IEC:2002+A1:2008 – 5 –
INTRODUCTION
It has been assumed in the drafting of this International Standard that the execution of its
provisions is entrusted to appropriately qualified and experienced persons.
This standard recognizes the internationally accepted level of protection against hazards such
as electrical, mechanical, thermal, fire and radiation of appliances when operated as in
normal use taking into account the manufacturer's instructions. It also covers abnormal
situations that can be expected in practice and takes into account the way in which
electromagnetic phenomena can affect the safe operation of appliances.
This standard takes into account the requirements of IEC 60364 as far as possible so that
there is compatibility with the wiring rules when the appliance is connected to the supply
mains. However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered
by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as
far as is reasonable. If applicable, the influence of one function on the other is taken into
account.
When a part 2 standard does not include additional requirements to cover hazards dealt with
in Part 1, Part 1 applies.
NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is
not necessary to specify particular requirements for the appliance in question over and above the general
requirements.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
NOTE 2 Horizontal and generic standards covering a hazard are not applicable since they have been taken into
consideration when developing the general and particular requirements for the IEC 60335 series of standards. For
example, in the case of temperature requirements for surfaces on many appliances, generic standards, such as
ISO 13732-1 for hot surfaces, are not applicable in addition to Part 1 or part 2 standards.
An appliance that complies with the text of this standard will not necessarily be considered to
comply with the safety principles of the standard if, when examined and tested, it is found to
have other features that impair the level of safety covered by these requirements.
An appliance employing materials or having forms of construction differing from those detailed
in the requirements of this standard may be examined and tested according to the intent of
the requirements and, if found to be substantially equivalent, may be considered to comply
with the standard.

---------------------- Page: 7 ----------------------
– 6 – 60335-2-101 © IEC:2002+A1:2008
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –

Part 2-101: Particular requirements for vaporizers



1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric vaporizers for household and
similar purposes, their rated voltage being not more than 250 V.
NOTE 101 Examples of appliances that are within the scope of this standard are air fresheners and insect
repellers. They may be plugged directly into a socket-outlet or connected to the supply mains by means of a
flexible cord and plug.
Appliances not intended for normal household use but which nevertheless may be a source of
danger to the public, such as appliances intended to be used by laymen in shops, in light
industry and on farms, are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by
appliances that are encountered by all persons in and around the home. However, in general,
it does not take into account
– persons (including children) whose
• physical, sensory or mental capabilities; or
• lack of experience and knowledge
prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
NOTE 102 Attention is drawn to the fact that
– for appliances to be used in vehicles or on board ships or aircraft, additional requirements may be necessary;
– in many countries additional requirements are specified by the national health authorities, the national
authorities responsible for the protection of labour, and similar authorities.

NOTE 103 This standard does not apply to
– appliances intended exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of
corrosive or explosive atmosphere (dust, vapour or gas);
– appliances for heating liquids (IEC 60335-2-15);
– insect killers (IEC 60335-2-59);
– fabric steamers (IEC 60335-2-85);
– humidifiers (IEC 60335-2-98).
2 Normative references
This clause of Part 1 is applicable.
3 Definitions
This clause of Part 1 is applicable except as follows.

---------------------- Page: 8 ----------------------
60335-2-101 © IEC:2002+A1:2008 – 7 –
3.1.9 Replacement:
normal operation
operation of the appliance filled with vaporizing medium in accordance with the instructions,
or unfilled, whichever is more unfavourable
3.101
vaporizer
appliance incorporating a heater for vaporizing a medium in order to affect the air in a room
4 General requirement
This clause of Part 1 is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable except as follows.
5.2 Addition:
The test of 21.101 is carried out on a new appliance.
6 Classification
This clause of Part 1 is applicable.
7 Marking and instructions
This clause of Part 1 is applicable except as follows.
7.1 Addition:
NOTE 101 If the rated power input does not exceed 10 W, the appliance may be marked "10 W max".
7.12 Addition:
The instructions shall include the substance of the following:
The appliance is only to be used with the recommended vaporizing medium. The use of
other substances may give rise to a toxic or fire risk.
For appliances that are directly plugged into socket-outlets, if the temperature rise of
accessible surfaces during the test of Clause 11 exceeds the value specified for handles,
knobs, grips and similar parts that are held for short periods only in normal use, the
instructions shall include the substance of the following:
The appliance has hot surfaces to evaporate the active ingredients and these surfaces
should not be touched during use.
8 Protection against access to live parts
This clause of Part 1 is applicable.

---------------------- Page: 9 ----------------------
– 8 – 60335-2-101 © IEC:2002+A1:2008
9 Starting of motor-operated appliances
This clause of Part 1 is not applicable.
10 Power input and current
This clause of Part 1 is applicable except as follows.
10.1 Addition:
For appliances marked with "10 W max", the power input shall not exceed this value.
11 Heating
This clause of Part 1 is applicable except as follows.
11.4 Modification:
Instead of operating the appliance at 1,15 times rated power input, it is supplied at 1,06
times rated voltage.
11.7 Replacement:
The appliance is operated until steady conditions are established.
11.8 Modification:
In Table 3, the temperature rise of parts in contact with oil is not measured.
Addition:
For appliances that are directly plugged into socket-outlets, the temperature rise of
accessible surfaces shall not exceed the limit specified for handles, knobs, grips and similar
parts that are held for short periods only in normal use. This does not apply to surfaces of
outlet grilles and slots for inserting the vaporizing medium, and surfaces within 7 mm of these
parts.
The temperature rise of the surface of the appliance adjacent to the socket-outlet shall not
exceed 40 K.
12 Void
13 Leakage current and electric strength at operating temperature
This clause of Part 1 is applicable except as follows.
13.1 Modification:
Instead of operating the appliance at 1,15 times rated power input, it is supplied at 1,06
times rated voltage.

---------------------- Page: 10 ----------------------
60335-2-101 © IEC:2002+A1:2008 – 9 –
14 Transient overvoltages
This clause of Part 1 is applicable.
15 Moisture resistance
This clause of Part 1 is applicable.
16 Leakage current and electric strength
This clause of Part 1 is applicable.
17 Overload protection of transformers and associated circuits
This clause of Part 1 is applicable.
18 Endurance
This clause of Part 1 is not applicable.
19 Abnormal operation
This clause of Part 1 is applicable except as follows.
19.1 Addition:
Appliances are also subjected to the test of 19.101.
19.2 Addition:
The appliance is operated without the vaporizing medium.
Modification:
Instead of operating the appliance at 0,85 times rated power input, it is supplied at 0,9 times
rated voltage.
19.3 Modification:
Instead of operating the appliance at 1,24 times rated power input, it is supplied at 1,1 times
rated voltage.
19.4 Modification:
Instead of operating the appliance at 1,15 times rated power input, it is supplied at 1,06
times rated voltage.

---------------------- Page: 11 ----------------------
– 10 – 60335-2-101 © IEC:2002+A1:2008
19.13 Addition:
During the tests, the temperature rise of accessible surfaces of appliances that are directly
plugged into socket-outlets shall not exceed
– 55 K, if of metal;
– 65 K, if of porcelain or vitreous enamel;
– 75 K, if of moulded material, rubber or wood.
This does not apply to surfaces of outlet grilles and slots for inserting the vaporizing medium,
and surfaces within 7 mm of these parts.
The temperature rise of the surface of the appliance adjacent to the socket-outlet shall not
exceed 65 K.
19.101 A single layer of double-hemmed pre-washed cotton sheet approximately
2 2
70 cm x 70 cm, having a specific mass between 140 g/m and 170 g/m when dry, is draped
over the appliance. It is operated under normal operation at rated voltage.
The cotton sheet shall not smoulder or ignite.
20 Stability and mechanical hazards
This clause of Part 1 is applicable.
21 Mechanical strength
This clause of Part 1 is applicable except as follows.
21.1 Addition:
NOTE 101 Appliances that are directly plugged into socket-outlets are tested with the appliance rigidly held by its
contact pins.
Appliances that are directly plugged into socket-outlets are also subjected to the test of
21.101 which is carried out on a new appliance.
21.101 An empty appliance is subjected to the free-fall test, procedure 2, of IEC 60068-2-32.
The number of falls is
– 50, if the mass of the appliance is greater than 250 g;
– 100, for other appliances.
After the test, the appliance shall not be damaged to such an extent that compliance with
Clauses 8 and 29 is impaired.
22 Construction
This clause of Part 1 is applicable except as follows.
22.4 Not applicable.

---------------------- Page: 12 ----------------------
60335-2-101 © IEC:2002+A1:2008 – 11 –
23 Internal wiring
This clause of Part 1 is applicable except as follows.
23.3 Addition:
Appliances that are directly plugged into socket-outlets, and can be rotated in relation to the
socket-outlet, are subjected to the following test.
The movable part is rotated clockwise and anticlockwise through the largest angle permitted
by the construction. It is rotated 100 times at a speed of approximately 10 rotations per min.
NOTE 101 A rotation is one movement, either clockwise or anticlockwise.
After the test, the appliance shall comply with Clauses 8 and 29 and the electrical connections
shall not have loosened.
24 Components
This clause of Part 1 is applicable.
25 Supply connection and external flexible cords
This clause of Part 1 is applicable except as follows.
25.5 Addition:
Type Z attachment is allowed.
26 Terminals for external conductors
This clause of Part 1 is applicable.
27 Provision for earthing
This clause of Part 1 is applicable.
28 Screws and connections
This clause of Part 1 is applicable.
29 Clearances, creepage distances and solid insulation
This clause of Part 1 is applicable.
30 Resistance to heat and fire
This clause of Part 1 is applicable except as follows.
30.2.2 Not applicable.

---------------------- Page: 13 ----------------------
– 12 – 60335-2-101 © IEC:2002+A1:2008
31 Resistance to rusting
This clause of Part 1 is applicable.
32 Radiation, toxicity and similar hazards
This clause of Part 1 is applicable except as follows.
Addition:
NOTE 101 The toxicity of vaporizing materials is controlled by national legislation.

---------------------- Page: 14 ----------------------
60335-2-101 © IEC:2002+A1:2008 – 13 –
Annexes
The annexes of Part 1 are applicable.

Bibliography
The bibliography of Part 1 is applicable except as follows.
Addition:
IEC 60335-2-15, Household and similar electrical appliances – Safety – Part 2-15: Particular
requirements for appliances for heating liquids
IEC 60335-2-59, Household and similar electrical appliances – Safety – Part 2-59: Particular
requirements for insect killers
IEC 60335-2-85, Household and similar electrical appliances – Safety – Part 2-85: Par
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.