General Information

Abstract

IEC 61169-48:2014, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series BMP RF coaxial connectors with blind mating, typically for use in 50 Ohms board to board connection. They may also be used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. Their operating frequency limit is up to 6 GHz. It describes the interface dimensions with gauging information, electrical and mechanical performance including the mandatory tests selected from IEC 61169-1:2013 applicable to all DS relating to type BMP connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.

Status
Published
Publication Date
22-Oct-2014
Current Stage
PPUB - Publication issued
Start Date
23-Oct-2014
Completion Date
31-Dec-2014

Buy Documents

Standard

IEC 61169-48:2014 - Radio-frequency connectors - Part 48: Sectional specification for series BMP R.F. coaxial connectors Released:10/23/2014

ISBN:978-2-8322-1902-7
English and French language (54 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 61169-48:2014 is an international standard issued by the International Electrotechnical Commission (IEC) that defines sectional specifications for series BMP radio-frequency (RF) coaxial connectors. These connectors feature blind mating capabilities and are primarily intended for 50 Ohms board-to-board connections. The standard outlines the dimensional, electrical, mechanical, and testing requirements that manufacturers and designers must follow to ensure compatibility and reliability. This standard supports applications in microwave systems, telecommunication, wireless communications, and other RF fields, with operating frequencies up to 6 GHz.

The specification provides guidance for preparing detailed specifications (DS) for BMP connectors, covering interface dimensions, gauging information, performance criteria, mandatory tests, and inspection requirements according to IEC 61169-1:2013 general requirements for RF connectors.

Key Topics

  • Connector Interface Dimensions
    Precise dimensions for connectors with pin-center contacts and socket-center contacts are detailed, including the use of gauging tools for quality assurance and compliance checks.

  • Blind Mating Capability
    Description of design features allowing connectors to be easily mated without visual alignment, enhancing installation efficiency in compact and complex assemblies.

  • Electrical and Mechanical Performance
    Parameters such as impedance matching, contact retention, mechanical durability, and maximum permissible deflection and axial clearance when mounted on printed circuit boards (PCBs).

  • Testing and Quality Assessment
    Sets forth mandatory and periodic tests-including electrical, mechanical, and climatic tests-ensuring consistent performance. The standard outlines acceptance test schedules and quality conformance procedures to maintain manufacturing standards.

  • Preparation of Detailed Specifications (DS)
    Instructions on writing detail specifications include component identification, performance criteria, marking requirements, and selection of relevant tests to suit specific application needs.

Applications

IEC 61169-48:2014 BMP RF coaxial connectors are widely used in:

  • Telecommunication Equipment
    Ensuring reliable and standardized board-to-board RF connections in communication devices operating in the GHz frequency range.

  • Microwave Systems
    Facilitating the precise interconnection of microwave components where stable impedance and minimal signal loss are critical.

  • Wireless Communication Devices
    Providing robust and quick mating connectors for applications requiring high-frequency data transfer and signal integrity.

  • RF Cables and Micro-strip Lines
    Supporting interoperability in cable-to-board and micro-strip RF systems, useful in various RF modules and subsystems.

  • High-performance PCB Assemblies
    Allowing for compact, space-efficient design by ensuring mechanical and electrical performance compliance in board-mounted connectors.

Related Standards

  • IEC 61169-1:2013
    General requirements, test methods, and performance criteria for radio-frequency connectors, serving as the foundation for this and other sectional specifications.

  • IEC 60068 Series
    Environmental testing standards referenced for climatic categories relevant to connector performance validation.

  • Other IEC 61169 Parts
    Cover various other types and series of RF connectors; users should consult relevant parts depending on connector type and application.


Keywords: IEC 61169-48, BMP RF coaxial connectors, radio-frequency connectors, blind mating, 50 Ohms connectors, PCB mounting, RF connector standards, microwave connectors, telecommunications connectors, IEC RF connector specification, electrical testing, mechanical performance, connector gauge, RF connector detail specifications.

Buy Documents

Standard

IEC 61169-48:2014 - Radio-frequency connectors - Part 48: Sectional specification for series BMP R.F. coaxial connectors Released:10/23/2014

ISBN:978-2-8322-1902-7
English and French language (54 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC 61169-48:2014 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 48: Sectional specification for series BMP R.F. coaxial connectors". This standard covers: IEC 61169-48:2014, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series BMP RF coaxial connectors with blind mating, typically for use in 50 Ohms board to board connection. They may also be used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. Their operating frequency limit is up to 6 GHz. It describes the interface dimensions with gauging information, electrical and mechanical performance including the mandatory tests selected from IEC 61169-1:2013 applicable to all DS relating to type BMP connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.

IEC 61169-48:2014, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series BMP RF coaxial connectors with blind mating, typically for use in 50 Ohms board to board connection. They may also be used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. Their operating frequency limit is up to 6 GHz. It describes the interface dimensions with gauging information, electrical and mechanical performance including the mandatory tests selected from IEC 61169-1:2013 applicable to all DS relating to type BMP connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.

IEC 61169-48:2014 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61169-48:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 61169-48 ®
Edition 1.0 2014-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 48: Sectional specification for series BMP R.F. coaxial connectors

Connecteurs pour fréquences radioélectriques –
Partie 48: Spécification intermédiaire relative aux connecteurs coaxiaux R.F.
série BMP
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 14
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.

IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 55 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,

77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.

Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient plus de 30 000 termes et définitions en
Spécifications techniques, Rapports techniques et autres
anglais et en français, ainsi que les termes équivalents dans
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
14 langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.

Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
Plus de 55 000 entrées terminologiques électrotechniques, en
La recherche avancée permet de trouver des publications IEC
en utilisant différents critères (numéro de référence, texte, anglais et en français, extraites des articles Termes et
comité d’études,…). Elle donne aussi des informations sur les Définitions des publications IEC parues depuis 2002. Plus
projets et les publications remplacées ou retirées. certaines entrées antérieures extraites des publications des

CE 37, 77, 86 et CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished

Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 61169-48 ®
Edition 1.0 2014-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 48: Sectional specification for series BMP R.F. coaxial connectors

Connecteurs pour fréquences radioélectriques –

Partie 48: Spécification intermédiaire relative aux connecteurs coaxiaux R.F.

série BMP
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 33.120.30 ISBN 978-2-8322-1902-7

– 2 – IEC 61169-48:2014 © IEC 2014
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact – Full detent and smooth bore . 6
3.1.2 Connector with socket-centre contact . 7
3.2 Gauges . 8
3.2.1 Gauge pin for socket-centre contact . 8
3.2.2 Test procedure . 9
3.2.3 Gauge for outer contact of connector with pin-centre contact . 10
3.3 Dimensions – Standard test connectors – Grade 0 . 12
3.3.1 Connector with pin-centre contact . 12
3.3.2 Connector with socket-centre contact . 13
3.4 General requirements for connector mounting on PCB . 14
3.4.1 General . 14
3.4.2 Maximum permitting deflexion . 15
3.4.3 Maximum permitting axial clearance . 15
4 Quality assessment procedure . 15
4.1 General . 15
4.2 Rating and characteristics (see Clause 5 of IEC 61169-1:2013) . 15
4.3 Test schedule and inspection requirements – Acceptance tests . 18
4.3.1 Acceptance tests . 18
4.3.2 Periodic tests . 19
4.4 Procedures for the quality conformance . 20
4.4.1 Quality conformance inspection . 20
4.4.2 Quality conformance and its maintenance – General procedure . 20
5 Instructions for preparation of detail specifications . 20
5.1 General . 20
5.2 Identification of the component . 21
5.3 Performance . 21
5.4 Marking, ordering information and related matters . 21
5.5 Selection of tests, test conditions and severities . 21
5.6 Blank detail specification pro-forma for type BMP connector . 22
6 Marking . 27
6.1 Marking of component . 27
6.2 Marking and contents of package . 27

Figure 1 – Connector with pin-centre contact . 7
Figure 2 – Connector with socket-centre contact . 8
Figure 3 – Gauge pin for socket-centre contact . 9
Figure 4 – Gauge A for sizing test . 10
Figure 5 – Gauge B for retention test for pin connectors – Full detent . 11
Figure 6 – Gauge C for retention test for pin connectors – Smooth bore . 12
Figure 7 – Connector with pin-centre contact . 13

Figure 8 – Connector with socket-centre contact . 14
Figure 9 – General requirements for connector mounting on PCB . 15

Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge pin for socket-centre contact . 9
Table 4 – Gauge A for sizing test . 10
Table 5 – Gauge B for retention test for pin connectors – Full detent . 11
Table 6 – Gauge C for retention test for pin connectors – Smooth bore . 12
Table 7 – Dimensions of connector with pin-centre contact . 13
Table 8 – Dimensions of connector with socket-centre contact . 14
Table 9 – Preferred climatic categories (see IEC 60068-1) . 16
Table 10 – Rating and characteristics . 16
Table 11 – Acceptance tests . 19
Table 12 – Periodic tests . 19

– 4 – IEC 61169-48:2014 © IEC 2014
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 48: Sectional specification for series
BMP R.F. coaxial connectors
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-48 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:

CDV Report on voting
46F/253/CDV 46F/291/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.

The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – IEC 61169-48:2014 © IEC 2014
RADIO-FREQUENCY CONNECTORS –
Part 48: Sectional specification for series
BMP R.F. coaxial connectors
1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for series BMP RF coaxial connectors with
blind mating, typically for use in 50 Ω board to board connection. They may also be used with
RF cables or micro-strips in microwave, telecommunication, wireless and other fields. Their
operating frequency limit is up to 6 GHz.
It describes the interface dimensions with gauging information, electrical and mechanical
performance including the mandatory tests selected from IEC 61169-1:2013 applicable to all
DS relating to type BMP connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a DS and covers test schedules and inspection requirements.
NOTE Metric dimension are original dimensions.
All undimensioned pictorial configurations are for reference purpose only.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:2013, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact – Full detent and smooth bore
The mating face of connector with pin-centre contact is shown in Figure 1 and its dimensions
are shown in Table 1.
(1)
(2)
(1)
(4)
(3)
IEC
(1) Mechanical and electrical reference plane.
(2) The slots shall meet mechanical and electrical requirements.
(3) The shape and size of outer conductor shall meet the electrical and mechanical performance requirements.
(4) R0,2 recommended for fillet.
Figure 1 – Connector with pin-centre contact
Table 1 – Dimensions of connector with pin-centre contact
mm
Ref. Additional notes
Min. Max.
a 0,68 0,71
b 1,05 1,10
c 2,30 2,50
a
– –
d
e 4,14 4,18
4,52 4,57 Full detent
f
4,23 4,28 Smooth bore
g 1,77 2,02
h 0,00 0,25
i 2,62 –
0,42 0,52 Full detent
j
1,00 1,20 Smooth bore
k 1,65 1,80
l 1,18 1,28
m 45° ± 2° Angle
q 0,00 0,15
r 0,3 ± 0,1 × 45° Chamfer
a
The diameter is chosen upon the assumption that the PTFE dielectric has a dielectric constant of 2,02 to give
an impedance of 50 Ω.
3.1.2 Connector with socket-centre contact
The mating face of connector with socket-centre contact is shown in Figure 2 and its
dimensions are shown in Table 2.

– 8 – IEC 61169-48:2014 © IEC 2014
(1)
(2)
IEC
(1) Mechanical and electrical reference plane.
(2) Slotted and closed to meet electrical and mechanical requirements.
Figure 2 – Connector with socket-centre contact
Table 2 – Dimensions of connector with socket-centre contact
Ref. mm Additional notes
Min. Max.
a
a – –
b 1,05 1,10
c 1,85 1,95
d 4,17 4,21
e 4,39 4,44
f 55° ± 2°
g 1,63 1,83
h 0,00 0,15
i 2,10 –
j 0,60 0,72
k 1,80 1,90
l 2,10 2,30
m 45° ± 2° Angle
b
– –
p
r 0,15 ± 0,05 × 45° Chamfer
a
Dimensions are chosen to meet mechanical performance requirements, when mating with
Φ0,68 mm~Φ0,71 mm pin.
b
The diameter is chosen upon the assumption that the PTFE dielectric has a dielectric constant of 2,02 to
give an impedance of 50 Ω.
3.2 Gauges
3.2.1 Gauge pin for socket-centre contact
The gauge pin for socket-centre contact is shown in Figure 3 and its dimensions are shown in
Table 3.
IEC
Figure 3 – Gauge pin for socket-centre contact
Table 3 – Dimensions of gauge pin for socket-centre contact
Ref. Gauge A Gauge B
Maximum material for sizing purposes Minimum material for
measurement of retention force
Mass of gauge: 28 g + 2 g
mm mm
Min. Max. Min. Max.
a
0,710 0,715 0,675 0,680
b
0,95 1,20 1,30 1,60
Material: steel, polished. Surface roughness: Ra = 0,4 µm maximum on the cylindrical surface of length b.

3.2.2 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of 0,95 mm. This is a sizing operation and should only be carried out when the socket-
centre contact is removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position.

– 10 – IEC 61169-48:2014 © IEC 2014
3.2.3 Gauge for outer contact of connector with pin-centre contact
3.2.3.1 Gauge A for sizing test
The gauge A for sizing test is shown in Figure 4 and its dimensions are shown in
Table 4.
IEC
Figure 4 – Gauge A for sizing test
Table 4 – Gauge A for sizing test
Ref. Gauge A
Maximum material for sizing purposes
mm
Min. Min.
a
4,15 4,17
c
1,40 1,50
d
2,50 2,70
f
55° ± 2°
Material: steel, polished. Surface roughness: Ra=0,4 µm maximum on the cylindrical surface of a and taper
surface angle f .
3.2.3.2 Test procedure
The gauge A shall be inserted into the outer contact three times. This is a sizing operation.

3.2.3.3 Gauge B for retention test for pin connectors – Full detent
3.2.3.3.1 Dimensions for gauge B
Gauge B for retention test for pin connectors – full detent is shown in Figure 5 and its
dimensions are shown in Table 5.
IEC
Figure 5 – Gauge B for retention test for pin connectors – Full detent
Table 5 – Gauge B for retention test for pin connectors – Full detent
Ref. Gauge B
Minimum material for measurement of retention force
Mass of gauge: 2 000 g + 100 g
mm
Min. Max.
a 4,18 4,21
b 4,39 4,44
c 1,80 1,90
d 2,50 2,70
e 45° ± 1°
f
55° ± 2°
g 0,60 0,72
Material: steel, polished. Surface roughness: Ra = 0,4 µm maximum on the cylindrical surface of length a,b and
taper surface angle e,f .
3.2.3.3.2 Test procedure
The gauge B shall be inserted into outer contact. The engagement force shall not exceed
63 N, the contact shall retain the mass of the gauge in a vertical downward position.

– 12 – IEC 61169-48:2014 © IEC 2014
3.2.3.4 Gauge C for retention test for pin connectors – Smooth bore
3.2.3.4.1 Dimension of the gauge
Gauge C for retention test for pin connectors – smooth bore is shown in Figure 6 and its
dimensions are shown in Table 6.
IEC
Figure 6 – Gauge C for retention test for pin connectors – Smooth bore
Table 6 – Gauge C for retention test for pin connectors – Smooth bore
Ref. Gauge C
Minimum material for measurement of retention force
Mass of gauge: 200 g + 10 g
mm
Min. Max.
a 4,15 4,17
c 1,40 1,50
d 2,50 2,70
f
55° ± 2°
Material: steel, polished. Surface roughness: Ra=0,4 µm maximum on the cylindrical surface of a and taper
surface angle f .
3.2.3.4.2 Test procedure
The gauge C shall be inserted into outer contact. The engagement force shall not exceed
15 N, the contact shall retain the mass of the gauge in a vertical downward position.
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact
The mating face of standard test connector with pin-centre contact is shown in Figure 7 and
its dimensions are shown in Table 7.

(1)
(1)
IEC
(1) Mechanical and electrical reference plane.
Figure 7 – Connector with pin-centre contact
Table 7 – Dimensions of connector with pin-centre contact
Ref. mm Additional notes
Min. Max.
a 0,690 0,710
b 1,07 1,10
c 2,35 2,45
a
– –
d
e 4,14 4,17
f 4,44 4,48
g 1,77 1,83
h 0,00 0,15
i 2,62 –
j 0,63 0,68
k 1,65 1,80
l 1,18 1,24
m Angle
45° ± 2°
p 2,25 2,30
q 0,00 0,15
r Chamfer
0,3 ± 0,1 × 45°
a
The diameter is chosen upon the assumption that the PTFE dielectric has a dielectric constant of 2,02 to
give an impedance of 50 Ω ± 0,5 Ω.

3.3.2 Connector with socket-centre contact
The mating face of standard test connector with socket-centre contact is shown in Figure 8
and its dimensions are shown in Table 8.

– 14 – IEC 61169-48:2014 © IEC 2014
(1)
IEC
(1) Mechanical and electrical reference plane.
Figure 8 – Connector with socket-centre contact
Table 8 – Dimensions of connector with socket-centre contact
Ref. mm Additional notes
Min. Max.
a
– –
a
b 1,07 1,10
c 1,85 1,95
d 4,17 4,21
e 4,37 4,42
f 55° ± 2°
g 1,68 1,72
h 0,00 0,05
i 2,10 –
j 0,65 0,70
k 1,80 1,90
l 2,10 2,30 Angle
m
45° ± 2°
b
– –
p
r
0,15 × 45° max
a
Dimension shall meet mechanical performance requirements.
b
The diameter is chosen upon the assumption that the PTFE dielectric has a dielectric constant of 2,02 to
give an impedance of 50 Ω ± 0,5 Ω.

3.4 General requirements for connector mounting on PCB
3.4.1 General
The typical mounting style of connectors are shown in Figure 9.
For two PCB applications, all the full detent sides of adapters should be in one same PCB and
the smooth bore sides of adapters should be in the other PCB when connecting.

3.4.2 Maximum permitting deflexion
When mating, the maximum permitting deflexion of the adapter as shown in Figure 9a) is 3°.
3.4.3 Maximum permitting axial clearance
When mating, the maximum permitting axial clearance between two boards is ±0,3 mm.
IECII IEC
a) Connecting range b) Working range
NOTE
C is the distance between two PCBs.
The axial working clearance range depends on the interface of BMP.
The radial working range depends on the length of the adapter, longer adapter gets bigger radial working range.
The connecting range depends on the length of the adapter and the chamfer range.
Figure 9 – General requirements for connector mounting on PCB
4 Quality assessment procedure
4.1 General
Clause 10 of IEC 61169-1:2013 apply to this sectional specification, except following
requirement. Subclauses 4.2 to 4.4 provide recommended rating, performance and test
conditions to be considered when writing a detail specification. They also provide an
appropriate schedule of tests with minimum levels of conformance inspection sampling,
together with the pro-forma blank detail specification (BDS) and instructions for the
preparation of a detail specification.
4.2 Rating and characteristics (see Clause 5 of IEC 61169-1:2013)
The values indicated below, in Table 10, are recommended for BMP series R.F. coaxial
connectors and are given for the writer of the detail specification. They are applicable for the
condition when the connectors are fully mated.
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.
Preferred climatic categories are given in Table 9.

– 16 – IEC 61169-48:2014 © IEC 2014
Table 9 – Preferred climatic categories (see IEC 60068-1)
Category designation Letter Temperature range Damp heat steady state
55/125/21 B 21 days
–55 °C to +125 °C
Table 10 – Rating and characteristics
Rating and characteristics Test method Value Remarks,
IEC 61169-1:2013 deviations from
Subclause standard test
method
Electrical
Nominal impedance
50 Ω
a
DC to 6 GHz
Frequency range
b
9.2.1
Return loss
– straight styles ≤–17,72 dB
– right-angle styles ≤–14 dB
– PCB mounting styles See DS
Power rating 9.2.2 See DS
Contact resistance, outer conductor and 9.2.3
centre conductor continuity (mated cabled
connectors)
c
Centre contact resistance
– initial
≤ 3,0 mΩ
– after conditioning
≤ 6,0 mΩ
c
Outer conductor continuity
– initial ≤ 2,5 mΩ
– after conditioning
≤ 5,0 mΩ
Insulation resistance 9.2.5
– initial  ≥ 5 000 MΩ
– after conditioning ≥ 200 MΩ
d e
9.2.6
Proof voltage at sea level
– non-cable styles 500 V (86~106) kPa
– 96IEC50-2 335 V
– 96IEC50-1 125 V
d e
9.2.6 4,4 kPa
Proof voltage at 3 000 m
approximately
– non-cable styles  125 V
equivalent to 20 km
– 96IEC50-2 85 V
– 96IEC50-1  35 V
d e
9.2.6 (86~106) kPa
Environmental test voltage at sea level
– non-cable styles 335 V
– 96IEC50-2 150 V
– 96IEC50-1 85 V
d e
9.2.6 4,4 kPa
Environmental test voltage at 3 000 m
approximately
– non-cable styles 85 V
equivalent to 20 km
– 96IEC50-2 35 V
– 96IEC50-1 25 V
Rating and characteristics Test method Value Remarks,
IEC 61169-1:2013 deviations from
Subclause standard test
method
Screening effectiveness 9.2.7 ≥ 60 dB, at 1 GHz Z ≤ 50 mΩ
t
g
Discharge test (corona test) 9.2.8 Atmospheric
na
pressure
g
Intermodulation level (PIM) 9.2.9 (IEC 62037) dBc
na
Mechanical
Soldering 9.3.2
– Solderability 9.3.2.2 See DS
– Resistance to soldering heat 9.3.2.3 See DS
g
Vibration 9.3.3
na
Insertion force (resilient contacts) 9.3.4 See Subclause 3.2
of this sectional
– centre contacts ≥0,28 N
specification
– outer contacts
– full detent / smooth bore
≥20 N / 2 N
Gauge retention force (resilient contacts) 9.3.4 See DS See Subclause 3.2
of this sectional
– centre contacts
specification
– outer contacts
– full detent / smooth bore
Centre contact captivation 9.3.5 Interface
dimensions shall
– axial force
≥ 17,8 N
remain as
specified.
– permitted displacement in each direction See DS
g
– axial torque
na
Engagement and separation 9.3.6
– Engagement
– Full detent / smooth bore
≤63 N / 15 N
– Separation
– Full detent / smooth bore
30 N to 63 N /≤10 N
Effectiveness of clamping device against 9.3.7 See DS
cable rotation (nutation of cable end)
Effectiveness of clamping device against 9.3.8 See DS
cable pulling
Effectiveness of clamping device against 9.3.9 See DS
cable bending
Effectiveness of clamping device against 9.3.10 See DS
cable torsion
g
Strength of coupling mechanism 9.3.11
na
g
Safety wire hole pull-out bending moment 9.3.12
na
(and shearing force)
Bump 9.3.13 10 g for full detent
100 m/s
n
10 Hz to 2 000 Hz
Shock 9.3.14 50 g for full detent
500 m/s
n
1/2 sine wave
11 ms
Climatic conditionings
g
Sealing non-hermetic sealed connectors 9.4.7
na
g
Hermetically sealed connectors 9.4.8
na
Water immersion test 9.4.9 See DS

– 18 – IEC 61169-48:2014 © IEC 2014
Rating and characteristics Test method Value Remarks,
IEC 61169-1:2013 deviations from
Subclause standard test
method
Salt mist 9.4.10 48 h spray
Endurance
Mechanical endurance 9.3.15
– smooth bore  1 000 operations
– full detent 100 operations
f 9.4.5
250 h at 125 °C
High temperature endurance
Low temperature endurance 9.4.6 See DS
Chemical contamination
Resistance to solvents and 9.4.11 See DS
contaminating fluids
Applicable fluids
Sulphur dioxide test 9.4.12 See DS
a
These values apply to basic connector. In practice, these may be influenced by the cable used and reference
should always be made to the actual values given in the DS.
b
Values for a single pair of connectors.
c
Voltages are r.m.s. values of a.c. at 40 Hz to 65 Hz, unless otherwise specified.
d
Some cables usable with these connectors have ratings lower than the values given here.
e
When interfaces are fully mated.
f
For certain connectors, the upper temperature limit is restricted by the cable characteristics. Reference
should be made to the relevant cable specification.
g
na = not applicable.
4.3 Test schedule and inspection requirements – Acceptance tests
4.3.1 Acceptance tests
There are no group C tests for levels H and M.
Table 11 describes the acceptance tests to be performed.

Table 11 – Acceptance tests
Assessment level M (higher) Assessment level H (lower)
IEC 61169-1:2013
– Test IL AQL Period Test IL AQL Period
Subclause
required required
% %
Group A1
Visual 9.1.1 a II 1 a S3 1,5
inspection
Group B1
Outline 9.1.2 a S4 0,4 a S3 4,0
dimension
Mechanical 9.1.2.2 a II 1 a S3 1,5
compatibility
Engagement 9.3.6 a S4 0,4 a S3 1,5
and
separation
Gauge 9.3.4 ia II 1 ia S3 1,5
retention
(resilient
contacts)
Sealing
non hermetic 9.4.7 ia II 0,65 ia S3 1
hermetic 9.4.8 ia II 0,015 ia S3 0,025
Voltage proof 9.2.6 a II 0,4 a II 4,0
Solderability 9.3.2.2 ia S4 0,4 ia S3 4,0
(d)
Insulation 9.2.5 a S4 0,4 a S3 4,0
resistance
For the symbols, abbreviations and procedures, see the end of Table 12.

4.3.2 Periodic tests
Table 12 describes the periodic tests to be performed.
Table 12 – Periodic tests
IEC 61169-1:2013   Assessment level M Assessment level H

Subclause (higher) (lower)
6 1 3 years 3 1 3 years
Group D1 (d)
Solderability connector
9.3.2.2 ia  ia
assemblies
Resistance to soldering heat 9.3.2.3 ia  ia
Mechanical tests on cable
fixing
Cable rotation (nutation) 9.3.7 na  na
Cable pulling 9.3.8 ia  ia
Cable bending 9.3.9 ia  ia
Cable torsion 9.3.10 ia  ia
6 1 3 years 3 1 3 years
Group D2 (d)
Contact resistance, outer
conductor and centre conductor 9.2.3 a  a
continuity
Vibration 9.3.3 a
Lot by Lot
Lot by Lot
– 20 – IEC 61169-48:2014 © IEC 2014
IEC 61169-1:2013   Assessment level M Assessment level H

Subclause (higher) (lower)
Damp heat, steady state 9.4.3 a  a
Group D3 (d)  1 1 3 years 1* 1 3 years
Dimensions piece-parts and
9.1.2 a  a
materials
Group D4 (d)  6 1 3 years 3 1 3 years
Mechanical endurance 9.3.15 a  a
High temperature endurance 9.4.5 a  a
Discharge test 9.2.8
Climatic conditioning 9.4 na  na
Group D5 (d)  6 1 3 years 3 1 3 years
Return loss 9.2.1 a  a
Screening effectiveness 9.2.7 a  a
Water immersion 9.4.9 ia  ia
Group D6 (d)  6 1 3 years 3 1 3 years
Contact captivation 9.3.5 a  a
Rapid change of temperature 9.4.4 na  na
Climatic sequence 9.4.2 a  a
Group D7 (d)  1§ 3 years 1§ 3 years
Salt mist 9.4.10 a
a suggested as applicable
ia test suggested (if technically applicable)
na not applicable
IL inspection level
AQL acceptable quality level
* one set of piece-parts each style and variant, unless using common piece parts
# for quality conformance, a total of two failures only permitted for level H and one failure only for level M
from groups D1 to D7
§ Group D7 – number of pairs for each solvent
(d) destructive tests – specimens shall not be returned to stock

4.4 Procedures for the quality conformance
4.4.1 Quality conformance inspection
This shall consist of test group A1 and B1 on a lot-by-lot basis and test group D1 to D7 on a
periodic basis.
4.4.2 Quality conformance and its maintenance – General procedure
This shall consist of three consecutive lots passing test groups A1 and B1 followed by
selection of specimens from the lots as appropriate. These specimens shall successfully pass
the specified periodic D tests.
5 Instructions for preparation of detail specifications
5.1 General
Detail specifications (DS) shall use the appropriate blank detail specification (BDS). The
following pages comprise the pro-forma BDS dedicated for use with type BMP connectors. As
such, it will already have entered on it information relating to:
a) the basic specification number applicable to all the detail specifications covering
connector styles of the type covered by the sectional specification;

b) the connector series designation.
The specification writer should enter the details relating to the connector style/variant(s) to
be covered as indicated. The numbers in brackets on the BDS correspond to the following
indications which shall be given.
5.2 Identification of the component
1) Enter the following details:
– style: the style designation of the connector including type of fixing and sealing,
if applicable;
– attachment: by deletion of the inapplicable options of cable/wire given for centre and
outer conductors;
– special features and markings: as applicable.
2) Enter details of assessment level and the climatic category.
3) A reproduction of the outline drawing and details of the panel piercing (if applicable). It
shall provide the maximum envelope dimensions, also the position of the reference plane
and, in the case of a fixed connector, the position of the mounting plane both relative to
the front face of the connector.
4) Any maximum panel thickness limitations for fixed connectors shall be stated.
5) Particulars of all variants covered by the DS. As appropriate, the information shall include:
– cable types (or sizes) applicable to each variant;
– alternative plated or protective finishes;
– details of alternative mounting flanges having either tapped or plain mounting holes;
– details of alternative solder spills or solder buckets including, when applicable, those
for use with microwave integrated circuit (MIC) components.
5.3 Performance
6) Performance data listing the most important characteristics of the connector in accordance
with the requirements of the relevant sectional specification. Deviations from the minimum
requirements shall be clearly indicated. Non-applicable parameters shall be marked “na”.
5.4 Marking, ordering information and related matters
7) Insert marking and ordering information as appropriate, together with details of related
documents and any invoked structural similarity.
5.5 Selection of tests, test conditions and severities
8) “na” shall be used to indicate non-applicable tests. All tests marked “a” by the detail
specification writer shall be mandatory.
When using the normal procedure with a dedicated BDS, the letter “a” – for applicable –
shall be entered in the “test required” column against each of the tests indicated as being
mandatory in the test schedule of the relevant sectional specification. Any additional test
required at the discretion of the specification writer shall also be indicated by an “a”.
The specification writer shall also indicate, when necessary, details of deviations from the
standard test methods and conditions including any relevant deviations given in the test
schedule of the sectional specification.

– 22 – IEC 61169-48:2014 © IEC 2014
5.6 Blank detail specification pro-forma for type BMP connector
The following pages contain the complete BDS pro-forma.
(1) Page 1 of
(2)
ELECTRONIC COMPONENT OF ASSESSED (3)    .
QUALITY IN ACCORDANCE WITH GENERIC

SPECIFICATION IEC 61169-1
(4)    .
NATIONAL REFERENCE
(5) Detail specification for radio frequency coaxial connector of Type
assessed quality
Style    Special features and markings
Method of cable/wire+ attachment centre conductor – solder/crimp+
outer conductor – solder/clamp/crimp +
+ delete as appropriate
(6) Assessment level    Characteristic impedance Climatic category.55/125./21./
50 Ω
(7) Outline and maximum dimensions Panel piercing and mounting details
(8) Variants
Variant No. Description 61196 IEC
of variant
.   .   .   .   .   .

.   .   .   .   .   .
Information about manufacturers who have components qualified under the IECQ Conformity Assessment
System is available through the IECQ on-line certificate system.

(9) Performance (including limiting conditions of use)
Ratings and Variant No. IEC 61169-1:2013 Value Remarks, including
characteristics Designation Subclause any deviations from
standard test
methods
Electrical
Nominal impedance  50Ω
Frequency range    9.2.1 0 GHz to 6 GHz Measurement
frequency range
Reflection factor
GHz
GHz
GHz
Centre contact 9.2.3 Initial
≤    mΩ
resistance
≤    mΩ After conditioning
Centre conductor    9.2.3 ≤    mΩ Resistance change
continuity due to conditioning

≤    mΩ
≤    mΩ
≤    mΩ
Outer contact 9.2.3 ≤    mΩ Initial
continuity
≤    mΩ After conditioning
Insulation resistance 9.2.5 Initial
≥    GΩ
After conditioning
≥    GΩ
9.2.6    kV 86 kPa to 106 kPa
+ Proof voltage at
sea level
kV
kV
kV
9.2.6    kV    kPa (if not 4,4
+ Proof voltage at
kPa)
4,4 kPa
kV
kV
kV
Screening    9.2.7    dB at    Z ≤.   mΩ

t
effectiveness    GHz
...