General Information

Abstract

IEC/PAS 61169-44:2010(E) provides information and rules for preparation of detail specification of SMP series blind mating RF connectors together with the pro forma blank detail specification. It also prescribes mating face dimensions for general connectors - grade 1, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to RBMA series blind mating RF connectors. It indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. SMP series push-on connectors with characteristic impedance 50 ohm are used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The operating frequency limit is up to 40 GHz.

Status
Replaced
Publication Date
26-Apr-2010
Current Stage
DELPUB - Deleted Publication
Start Date
12-Dec-2012
Completion Date
28-Aug-2026

Buy Documents

Technical specification

IEC PAS 61169-44:2010 - Radio-frequency connectors - Part 44: Sectional specification for SMP push-on radio-frequency coaxial connectors Released:4/27/2010

ISBN:978-2-88910-804-6
English language (31 pages)
sale 15% off
Preview
sale 15% off
Preview

Relations

Effective Date
05-Sep-2023

Buy Documents

Technical specification

IEC PAS 61169-44:2010 - Radio-frequency connectors - Part 44: Sectional specification for SMP push-on radio-frequency coaxial connectors Released:4/27/2010

ISBN:978-2-88910-804-6
English language (31 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC PAS 61169-44:2010 is a technical specification published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 44: Sectional specification for SMP push-on radio-frequency coaxial connectors". This standard covers: IEC/PAS 61169-44:2010(E) provides information and rules for preparation of detail specification of SMP series blind mating RF connectors together with the pro forma blank detail specification. It also prescribes mating face dimensions for general connectors - grade 1, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to RBMA series blind mating RF connectors. It indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. SMP series push-on connectors with characteristic impedance 50 ohm are used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The operating frequency limit is up to 40 GHz.

IEC/PAS 61169-44:2010(E) provides information and rules for preparation of detail specification of SMP series blind mating RF connectors together with the pro forma blank detail specification. It also prescribes mating face dimensions for general connectors - grade 1, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to RBMA series blind mating RF connectors. It indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. SMP series push-on connectors with characteristic impedance 50 ohm are used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The operating frequency limit is up to 40 GHz.

IEC PAS 61169-44:2010 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC PAS 61169-44:2010 has the following relationships with other standards: It is inter standard links to IEC 61169-44:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC PAS 61169-44:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC/PAS 61169-44 ®
Edition 1.0 2010-04
PUBLICLY AVAILABLE
SPECIFICATION
PRE-STANDARD
colour
inside
Radio-frequency connectors –
Part 44: Sectional specification for series SMP push-on radio-frequency coaxial
connectors
IEC/PAS 61169-44:2010(E)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC/PAS 61169-44 ®
Edition 1.0 2010-04
PUBLICLY AVAILABLE
SPECIFICATION
PRE-STANDARD
colour
inside
Radio-frequency connectors –
Part 44: Sectional specification for series SMP push-on radio-frequency coaxial
connectors
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
V
ICS 33.120.30 ISBN 978-2-88910-804-6
– 2 – PAS 61169-44 © IEC:2010(E)
CONTENTS
FOREWORD.4
1 Scope.6
2 Normative references .6
3 Mating face and gauge information.6
3.1 Dimensions – General connectors – Grade 1.7
3.1.1 Connector with pin-centre contact.7
3.1.2 Connector with socket-centre contact .10
3.2 Gauges .11
3.2.1 Gauge pin for socket-centre contact .11
3.2.2 Gauge for outer contact of connector with socket-centre contact .12
3.3 Dimensions- standard test connectors – Grade 0 .15
3.3.1 Connector with pin-centre contact.15
3.3.2 Connector with socket-centre contact .17
4 Quality assessment procedure.18
4.1 General .18
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) .18
4.3 Test schedule and inspection requirements .22
4.3.1 Acceptance tests .22
4.3.2 Periodic tests .23
4.4 Procedures.24
4.4.1 Quality conformance inspection .24
4.4.2 Qualification approval and its maintenance.24
5 Instructions for preparation of detail specifications .25
5.1 General .25
5.2 Identification of the detail specification .25
5.3 Identification of the component.25
5.4 Performance.26
5.5 Marking, ordering information and related matters .26
5.6 Selection of tests, test conditions and severities.26
5.7 Blank detail specification pro forma for series RBMA connectors.27

Figure 1 – Connector with pin-centre contact limited detent and full detent (for
dimensions and notes, see Table 1).7
Figure 2 – Connector with pin-centre contact – Smooth bore (for dimensions and
notes, see Table 2) .8
Figure 3 – Connector with pin- centre contact – Catchers mit (for dimensions and
notes, see Table 3) .9
Figure 4 – Connector with socket-centre contact (for dimensions and notes, see
Table 4) .10
Figure 5 – Gauge pin for socket-centre contact (for dimensions and notes, see
Table 5) .11
Figure 6 – Gauge with limited detent for outer contact of connector with socket-outer
contact (for dimensions and notes, see Table 6) .12
Figure 7 – Gauge pin – Full detent for outer contact of connector with socket-centre
(for dimensions and notes, see Table 7) .13

PAS 61169-44 © IEC:2010(E) – 3 –
Figure 8 – Gauge pin – Smooth bore for outer contact of connector with socket-centre
(for dimensions and notes, see Table 8) .14
Figure 9 – Connector with pin-centre contact – Limited detent and full detent (for
dimensions and notes, see Table 9).15
Figure 10 – Connector with pin – centre contact – Smooth bore (for dimensions and
notes, see Table 10) .16
Figure 11 – Connector with socket-centre contact (for dimensions and notes, see
Table 11) .17

Table 1 – Dimensions of connector with pin-centre contact limited detent and full
detent .7
Table 2 – Dimensions of connector with pin-centre contact – Smooth bore .8
Table 3 – Dimensions of connector with pin-centre contact – Catchers mit.9
Table 4 – Dimensions of connector with socket-centre contact.10
Table 5 – Dimensions of gauge pin for socket-centre contact.11
Table 6 – Gauge with limited detent for outer contact of connector with socket-outer
contact.12
Table 7 – Gauge pin – Full detent for outer contact of connector with socket-centre .13
Table 8 – Gauge pin – Smooth bore for outer contact of connector with socket-centre.14
Table 9 – Dimensions of connector with pin-centre contact – Limited detent and full
detent .16
Table 10 – Dimensions of connector with pin-centre contact – Smooth bore .17
Table 11 – Dimensions of connector with socket-centre contact.18
Table 12 – Rating and characteristics .19
Table 13 – Acceptance tests .22
Table 14 – Periodic tests .23

– 4 – PAS 61169-44 © IEC:2010(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 44: Sectional specification for series SMP
push-on radio-frequency coaxial connectors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
A PAS is a technical specification not fulfilling the requirements for a standard, but made
available to the public.
IEC-PAS 61169-44 has been processed by subcommittee 46F: RF and microwave passive
components, of IEC technical committee 46: Cables, wires, waveguides, R.F. connectors,
R.F. and microwave passive components and accessories.
The text of this PAS is based on the This PAS was approved for
following document: publication by the P-members of the
committee concerned as indicated in
the following document
Draft PAS Report on voting
46F/153/PAS 46F/159/RVD
Following publication of this PAS, which is a pre-standard publication, the technical committee
or subcommittee concerned may transform it into an International Standard.

PAS 61169-44 © IEC:2010(E) – 5 –
This PAS shall remain valid for an initial maximum period of 3 years starting from the
publication date. The validity may be extended for a single 3-year period, following which it
shall be revised to become another type of normative document, or shall be withdrawn.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – PAS 61169-44 © IEC:2010(E)
RADIO-FREQUENCY CONNECTORS –
Part 44: Sectional specification for series SMP
push-on radio-frequency coaxial connectors

1 Scope
Series SMP push-on connectors have a characteristic impedance of 50 Ω and are used with
RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The
connectors are usable up to a frequency of 40 GHz.
This PAS provides information and rules for preparation of detail specification of SMP series
push-on RF coaxial connectors together with the pro forma blank detail specification.
It also prescribes mating face dimensions for general purpose connectors – grade 1,
dimensional details of standard test connectors-grade 0, gauging information and tests
selected from IEC 61169-1 applicable to all detail specifications relating to series SMP RF
connectors.
This PAS indicates the recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
)
requirements and measuring methods
Amendment 1 (1996)
Amendment 2 (1997)
3 Mating face and gauge information
Metric dimensions are original dimensions.
All undimensioned pictorial configurations are for reference purpose only.
.
—————————
)
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and its
Amendment 2:1997.
l
k
e
f
j
g
h
i
m
PAS 61169-44 © IEC:2010(E) – 7 –

3.1 Dimensions – General connectors – Grade 1
3.1.1 Connector with pin-centre contact
3.1.1.1 Connector with pin-centre contact limited detent and full detent
Note 1
Note 4
Note 2
Note 3
Figure 1 – Connector with pin-centre contact limited detent and full detent
(for dimensions and notes, see Table 1)
Table 1 – Dimensions of connector with pin-centre
contact limited detent and full detent
Ref. mm Notes
Min. Max.
a 3,53 3,68
b 3,13 3,23
c 3,00 3,10 Limited detent
2,90 3,00 Full detent
d 0,38 0,41
e 30° REF, Angle
f 0,84 0,94
g 0,52 0,60
h 1,37 1,52 Limited detent
1,30 1,45 Full detent
i 2,74 2,84
j 0,00 —
k 1,14 1,40
l 0,08 0,20
m 40° 50° Angle
n — —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameter chosen must meet the nominal impedance of 50 Ω and electrical and
mechanical requirements.
NOTE 3 To meet electrical requirement.
NOTE 4 Spherical or chamfered.
φn
φd
φ
c
φb
φa
l
k
f
j
h
i
m
– 8 – PAS 61169-44 © IEC:2010(E)
3.1.1.2 Connector with pin-centre contact – Smooth bore

Note 1
Note 4
Note 2
Note 3
Figure 2 – Connector with pin-centre contact –
Smooth bore (for dimensions and notes, see Table 2)
Table 2 – Dimensions of connector with pin-centre contact – Smooth bore
Ref. mm Notes
Min. Max.
a 3,53 3,68
b 3,13 3,23
d 0,38 0,41
f 0,84 0,94
h 1,50 1,65
i 2,74 2,84
j 0,00 —
k 1,14 1,40
l 0,08 0,20
m Angle
40° 50°
n — —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameter chosen must meet the nominal impedance of 50 Ω and electrical and
mechanical requirements.
NOTE 3 To meet electrical requirement.
NOTE 4 Spherical or chamfered.

φ
n
φd
φb
a
φ
k
f
j
i
m
PAS 61169-44 © IEC:2010(E) – 9 –
3.1.1.3 Connector with pin-centre contact – Catchers mit

Note 1
Note 4
Note 2
Note 3
Figure 3 – Connector with pin- centre contact –
Catchers mit (for dimensions and notes, see Table 3)
Table 3 – Dimensions of connector with pin-centre contact – Catchers mit
Ref. mm Notes
Min. Max.
a 5,94 —
b — 5,59
c 3,13 3,23
d 0,38 0,41
f 1,09 1,19
i 2,74 2,84
j 0,00 —
k 1,14 1,40
m 45 °REF. Angle
n — —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameter chosen must meet the nominal impedance of 50 Ω and electrical and
mechanical requirements.
NOTE 3 To meet electrical requirement.
NOTE 3 Spherical or chamfered.

φn
φd
φc
φb
φa
– 10 – PAS 61169-44 © IEC:2010(E)
3.1.2 Connector with socket-centre contact

Note 1
g
Note   7
f
Note 3Note 3
Note 2
Note 4 c
Note 5
d
e
Figure 4 – Connector with socket-centre contact
(for dimensions and notes, see Table 4)
Table 4 – Dimensions of connector with socket-centre contact
Ref. p Notes
Min. Max.
a — 3,43
b — —
c 0,00 0,20
d 0,00 0,20
e 1,78 —
f 0,46 0,64 uncabled
0,64 0,89 cabled
g 2,84 —
h — —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameter should comply with required VSWR, mating feature and durability when mated
with a Φ0,38~Φ0,41 diameter.
NOTE 3 The form and dimensions of outer conductor to meet mechanical and electrical requirements.
NOTE 4 Diameter is chosen upon the assumption that the PTFE dielectric has a dielectric constant of
2,02 to give an impedance of 50 Ω.
NOTE 5 The number and dimension of slots must meet mechanical and electrical requirements.
NOTE 6 Anti-rock ring is optional.
NOTE 7 EMI shield is optional.

φh
φb
φa
φ
a
φ
PAS 61169-44 © IEC:2010(E) – 11 –
3.2 Gauges
3.2.1 Gauge pin for socket-centre contact

50� 10�
±
R0.4mm max
Bend radius
0.2mm max
Figure 5 – Gauge pin for socket-centre contact
(for dimensions and notes, see Table 5)
Table 5 – Dimensions of gauge pin for socket-centre contact
Ref. Gauge A Gauge B
(for sizing purposes) (for measurement of retention force for inner
conductor)
Mass of gauge: (28+2)g
mm mm
Min. Max. Min. Max.
a 0,410 0,415 0,375 0,380
b 1,00 1,14 1,00 1,14
Material: steel, polished.
Surface roughness: Ra ≤ 0,4 µm, on the cylindrical surface of length b.

3.2.1.1 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of 1,00 mm. This is a sizing operation and should only be carried out when the socket-
centre contact is removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position. The test should also be carried out on
connector when the socket-centre contact is not removed.
3.2.1.2 Additional test
At the conclusion of the tests and if prescribed in the DS, the force necessary to insert gauge
A shall be measured. When the additional test is required, the force required shall not exceed
7,0 N.
b
l
m
e
g
d
f
h
– 12 – PAS 61169-44 © IEC:2010(E)
3.2.2 Gauge for outer contact of connector with socket-centre contact
3.2.2.1 Gauge with limited detent for outer contact of connector with socket-centre
contact
Figure 6 – Gauge with limited detent for outer contact of connector
with socket-outer contact (for dimensions and notes, see Table 6)
Table 6 – Gauge with limited detent for outer contact of connector
with socket-outer contact
Ref. Gauge A Gauge B Notes
(for sizing purposes) (for measurement of retention force
for inner conductor)
Mass of gauge : (900+20) g
mm mm
Min. Max. Min. Max.
a 3,53 3,68 3,53 3,68
b 3,13 3,23 3,13 3,23
c 3,00 3,02 3,08 3,10 Note 1
d 0,84 0,94 0,84 0,94
e Note 2
28° 32° 28° 32°
f 0,52 0,60 0,52 0,60
g Note 3
33° 37° 33° 37°
h 2,74 2,84 2,74 2,84
i — 2,40 — 2,40
l 0,08 0,20 0,08 0,20
m
40° 50° 40° 50°
Material: steel, polished.
NOTE 1 Surface roughness: Ra ≤ 0,4 µm, on the cylindrical surface of length c.
NOTE 2 Surface roughness: Ra ≤ 0,4 µm, on the slope surface of angle e.
NOTE 3 Surface roughness: Ra ≤ 0,4 µm, on the slope surface of angle g.
φi
φc
φb
φa
l
m
e
g
d
f
h
PAS 61169-44 © IEC:2010(E) – 13 –
3.2.2.1.1 Test procedure
The outer contact shall insert into the gauge A once. This is a sizing operation. After this, the
outer contact shall insert into the gauge B. The outer contact shall retain the gauge in a
vertical downward direction.
3.2.2.1.2 Additional test
After the sizing and if prescribed in the DS, the force required to insert gauge A shall be
measured. This force shall not exceed 45 N.
3.2.2.2 Gauge pin – Full detent for outer contact of connector with socket-centre

Figure 7 – Gauge pin – Full detent for outer contact of connector with socket-centre
(for dimensions and notes, see Table 7)
Table 7 – Gauge pin – Full detent for outer contact of connector with socket-centre
Ref. Gauge A Gauge B Notes
(for sizing purposes) (for measurement of retention force
for inner conductor)
Mass of gauge: (900+20) g
mm mm
Min. Max. Min. Max.
a 3,53 3,68 3,53 3,68
b 3,13 3,23 3,13 3,23
c 2,90 2,92 2,98 3,00 Note 1
d 0,84 0,94 0,84 0,94
e 28° 32° 28° 32° Note 2
f 0,52 0,60 0,52 0,60
g Note 3
33° 37° 33° 37°
h 2,74 2,84 2,74 2,84
i — 2,40 — 2,40
l 0,08 0,20 0,08 0,20
m
40° 50° 40° 50°
Material: steel, polished.
NOTE 1 Surface roughness: Ra ≤0,4 µm, on the cylindrical surface of length c.
NOTE 2 Surface roughness: Ra ≤0,4 µm, on the slope surface of angle e.
NOTE 3 Surface roughness: Ra ≤0,4 µm, on the slope surface of angle g.
i
φ
φc
b
φ
φa
l
m
g
c
e
– 14 – PAS 61169-44 © IEC:2010(E)
3.2.2.2.1 Test procedure
The outer contact shall insert into the gauge A once. This is a sizing operation. After this, the
outer contact shall insert into the gauge B. The outer contact shall retain the gauge in a
vertical downward direction.
3.2.2.2.2 Additional test
After the sizing and if prescribed in the DS, the force required to insert gauge A shall be
measured. This force shall not exceed 45 N.
3.2.2.3 Gauge pin – Smooth bore for outer contact of connector with socket-centre

Figure 8 – Gauge pin – Smooth bore for outer contact of connector
with socket-centre (for dimensions and notes, see Table 8)
Table 8 – Gauge pin – Smooth bore for outer contact of connector with socket-centre
Ref. Gauge A Gauge B Notes
(for sizing purposes) (for measurement of retention force
for inner conductor)
Mass of gauge: (900+20) g
mm mm
Min. Max. Min. Max.
a 3,53 3,68 3,53 3,68
b 3,13 3,15 3,21 3,23 Note 1
c 0,84 0,94 0,84 0,94
e 2,74 2,84 2,74 2,84
g 33° 37° 33° 37° Note 2
i — 2,40 — 2,40
l 0,08 0,20 0,08 0,20
m
40° 50° 40° 50°
Material: steel, polished.
NOTE 1 Surface roughness: Ra ≤0,4 µm, on the cylindrical surface of length c.
NOTE 2 Surface roughness: Ra ≤0,4 µm, on the slope surface of angle g.
φi