Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant condensing unit or compressor

Deals with the safety of commercial refrigerators with an incorporated compressor, or split systmes supplied in two units for assembly together. Examples are refrigerated display and storage cabinets, service counters, blast chillers. For domestic refrigerators see IEC 60335-2-24. For motor compressors, see IEC 60335-2-34. For commercial vending machines, see IEC 60335-2-75.

Appareils électrodomestiques et analogues - Sécurité - Partie 2-89 : Règles particulières pour les appareils de réfrigération à usage commercial avec une unité de condensation du fluide frigorigène ou un compresseur incorporés ou à distance

Traite de la sécurité des réfrigerateurs à usage commercial avec un compresseur incorporé ou un système à deux ensembles sous forme de deux unités en vue d'un assemblage. Des exemples sont les présentoirs ou meubles de stockage réfrigérés, les comptoirs de service, les congélateurs à jet d'air. Pour les réfrigérateurs à usage domestique, voir la CEI 60335-2-24. Pour les moto-compresseurs, voir la CEI 60335-2-34. Pour les distributeurs sans moyen de paiement, voir la CEI 60335-2-75.

General Information

Status
Published
Publication Date
20-Mar-2007
Current Stage
DELPUB - Deleted Publication
Start Date
24-Feb-2010
Completion Date
26-Oct-2025
Ref Project

Relations

Standard
IEC 60335-2-89:2002 - Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant condensing unit or compressor Released:5/7/2002 Isbn:2831862922
English and French language
71 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 60335-2-89:2002+AMD1:2005+AMD2:2007 CSV - Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant condensing unit or compressor Released:3/21/2007 Isbn:2831890292
English and French language
81 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 60335-2-89:2002+AMD1:2005 CSV - Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant condensing unit or compressor Released:4/27/2005 Isbn:2831879280
English and French language
79 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME CEI
INTERNATIONALE IEC
60335-2-89
INTERNATIONAL
Première édition
STANDARD
First edition
2002-05
Appareils électrodomestiques et analogues –
Sécurité –
Partie 2-89:
Règles particulières pour les appareils de
réfrigération à usage commercial avec une unité
de condensation du fluide frigorigène ou un
compresseur incorporés ou à distance
Household and similar electrical appliances –
Safety –
Part 2-89:
Particular requirements for commercial
refrigerating appliances with an incorporated
or remote refrigerant condensing unit
or compressor
Numéro de référence
Reference number
CEI/IEC 60335-2-89:2002
Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For

devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1

exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
60335-2-89
INTERNATIONAL
Première édition
STANDARD
First edition
2002-05
Appareils électrodomestiques et analogues –
Sécurité –
Partie 2-89:
Règles particulières pour les appareils de
réfrigération à usage commercial avec une unité
de condensation du fluide frigorigène ou un
compresseur incorporés ou à distance
Household and similar electrical appliances –
Safety –
Part 2-89:
Particular requirements for commercial
refrigerating appliances with an incorporated
or remote refrigerant condensing unit
or compressor
 IEC 2002 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch  Web: www.iec.ch
CODE PRIX
W
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60335-2-89  CEI:2002
SOMMAIRE
AVANT-PROPOS.6

INTRODUCTION.10

1 Domaine d'application .12

2 Références normatives.14

3 Définitions .14

4 Prescriptions générales .16

5 Conditions générales d'essais .18

6 Classification.20
7 Marquage et indications .20
8 Protection contre l'accès aux parties actives .24
9 Démarrage des appareils à moteur.26
10 Puissance et courant .26
11 Echauffements .26
12 Vacant.32
13 Courant de fuite et rigidité diélectrique à la température de régime .32
14 Surtensions transitoires.32
15 Résistance à l'humidité.32
16 Courant de fuite et rigidité diélectrique .34
17 Protection contre la surcharge des transformateurs et des circuits associés.34
18 Endurance.34
19 Fonctionnement anormal .34
20 Stabilité et dangers mécaniques .38
21 Résistance mécanique .38
22 Construction .40
23 Conducteurs internes .56
24 Composants .56
25 Raccordement au réseau et câbles souples extérieurs .56
26 Bornes pour conducteurs externes .58
27 Dispositions en vue de la mise à la terre .58

28 Vis et connexions .58
29 Distances dans l'air, lignes de fuite et isolation solide .58
30 Résistance à la chaleur et au feu.60
31 Protection contre la rouille.60
32 Rayonnement, toxicité et dangers analogues.60
Annexes .66
Annexe AA (normative) Essai à rotor bloqué des moteurs de ventilateurs .66
Bibliographie.70

60335-2-89 © IEC:2002 – 3 –
CONTENTS
FOREWORD.7

INTRODUCTION.11

1 Scope.13

2 Normative references.15

3 Definitions .15

4 General requirement .17

5 General conditions for the tests.19
6 Classification .21
7 Marking and instructions .21
8 Protection against access to live parts .25
9 Starting of motor-operated appliances.27
10 Power input and current .27
11 Heating.27
12 Void .33
13 Leakage current and electric strength at operating temperature.33
14 Transient overvoltages.33
15 Moisture resistance.33
16 Leakage current and electric strength .35
17 Overload protection of transformers and associated circuits .35
18 Endurance .35
19 Abnormal operation.35
20 Stability and mechanical hazards .39
21 Mechanical strength.39
22 Construction .41
23 Internal wiring .57
24 Components .57
25 Supply connection and external flexible cords .57
26 Terminals for external conductors .59
27 Provision for earthing.59

28 Screw and connections .59
29 Creepage distances, clearances, and distances through insulation .59
30 Resistance to heat and fire .61
31 Resistance to rusting .61
32 Radiation, toxicity and similar hazards.61
Annexes.67
Annex AA (normative) Locked-rotor test of fan motors .67
Bibliography .71

– 4 – 60335-2-89  CEI:2002
Figure 101 – Appareillage pour l’essai de débordement .62

Figure 102 – Détails de la pointe de l’outil à rayer .64

Figure AA.1 – Circuit d'alimentation pour l'essai à rotor bloqué d'un moteur de

ventilateur monophasé.68

Tableau 101 – Températures maximales pour les moto-compresseurs.30

Tableau 102 – Paramètres d'inflammabilité des fluides frigorigènes.52

60335-2-89 © IEC:2002 – 5 –
Figure 101 – Apparatus for spillage test.63

Figure 102 – Scratching tool tip details .65

Figure AA.1 – Supply circuit for locked-rotor test of a single-phase fan motor .69

Table 101 – Maximum temperatures for motor-compressors.31

Table 102 – Refrigerant flammability parameters .53

– 6 – 60335-2-89  CEI:2002
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
APPAREILS ÉLECTRODOMESTIQUES
ET ANALOGUES – SÉCURITÉ –
Partie 2-89: Règles particulières pour les appareils de réfrigération

à usage commercial avec une unité de condensation du fluide frigorigène

ou un compresseur incorporés ou à distance

AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement
avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les
deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les
Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La présente partie de la Norme internationale CEI 60335 a été établie par le sous-comité
61C: Appareils domestiques de réfrigération, du comité d'études 61 de la CEI: Sécurité des
appareils électrodomestiques et analogues.
Elle constitue la première édition de la CEI 60335-2-89.

Le texte de cette partie de la CEI 60335 est issu des documents suivants:
FDIS Rapport de vote
61C/208/FDIS 61C/211/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
La présente partie 2 doit être utilisée conjointement avec la dernière édition de la CEI 60335-1 et
ses amendements. Elle a été établie sur la base de la quatrième édition (2001) de cette norme.
NOTE 1 L’expression « Partie 1 » utilisée dans la présente norme fait référence à la CEI 60335-1.
La présente partie 2 complète ou modifie les articles correspondants de la Partie 1 de la
CEI 60335-1 de façon à la transformer en norme CEI: Règles de sécurité pour les appareils
de réfrigération à usage commercial avec une unité de condensation du fluide frigorigène ou
un compresseur incorporés ou à distance.

60335-2-89 © IEC:2002 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –

SAFETY –
Part 2-89: Particular requirements for commercial refrigerating appliances

with an incorporated or remote refrigerant condensing unit or compressor

FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by subcommittee 61C:
Household appliances for refrigeration, of IEC technical committee 61: Safety of household and
similar electrical appliances.
It forms the first edition of IEC 60335-2-89.
The text of this part of IEC 60335 is based on the following documents:

FDIS Report on voting
61C/208/FDIS 61C/211/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fourth edition (2001) of that standard.
NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.
This part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for commercial refrigerating
appliances with an incorporated or remote refrigerant condensing unit or compressor.

– 8 – 60335-2-89  CEI:2002
Lorsqu'un paragraphe particulier de la Partie 1 n'est pas mentionné dans cette partie 2,
ce paragraphe s'applique pour autant qu'il est raisonnable. Lorsque la présente norme

spécifie «addition», «modification» ou «remplacement», le texte correspondant de la Partie 1

doit être adapté en conséquence.

NOTE 2 Le système de numérotation suivant est utilisé:

− paragraphes, tableaux et figures : ceux qui sont numérotés à partir de 101 sont complémentaires à ceux de la
Partie 1;
− notes: à l’exception de celles qui sont dans un nouveau paragraphe ou de celles qui concernent des notes de
la Partie 1, les notes sont numérotées à partir de 101, y compris celles des articles ou paragraphes qui sont

modifiés ou remplacés;
− annexes: les annexes complémentaires sont appelées AA, BB, etc.
NOTE 3 Les caractères d'imprimerie suivants sont utilisés:
− prescriptions: caractères romains;
− modalités d'essais: caractères italiques;
− notes: petits caractères romains.
Les mots en gras dans le texte sont définis à l'Article 3. Lorsqu'une définition concerne un adjectif, l'adjectif et le
nom associé figurent également en gras.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2004. A
cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
60335-2-89 © IEC:2002 – 9 –
Where a particular subclause of Part 1 is not mentioned in this part 2, that subclause applies
as far as is reasonable. Where this standard states "addition", "modification” or "replacement",

the relevant text in Part 1 is to be adapted accordingly.

NOTE 2 The following numbering system is used:

– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;

– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including

those in a replaced clause or subclause;

– additional annexes are lettered AA, BB, etc.

NOTE 3 The following print types are used:

– requirements: in roman type;
– test specifications: in italic type;
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the
associated noun are also in bold.
The committee has decided that the contents of this publication will remain unchanged until
2004. At this date the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition or
• amended.
– 10 – 60335-2-89  CEI:2002
INTRODUCTION
Il a été considéré en établissant la présente Norme internationale que l'exécution de ses

dispositions était confiée à des personnes expérimentées et ayant une qualification

appropriée.
Cette norme reconnaît le niveau de protection internationalement accepté contre les risques

électriques, mécaniques, thermiques, liés au feu et au rayonnement des appareils, lorsqu'ils

fonctionnent comme en usage normal en tenant compte des instructions du fabricant. Elle

couvre également les situations anormales auxquelles on peut s'attendre dans la pratique.

Cette norme tient compte autant que possible des prescriptions de la CEI 60364, de façon à
rester compatible avec les règles d'installation quand l’appareil est raccordé au réseau
d’alimentation. Cependant, des règles nationales d'installation peuvent être différentes.
Si un appareil compris dans le domaine d’application de cette norme comporte également des
fonctions qui sont couvertes par une autre partie 2 de la CEI 60335, la partie 2 correspon-
dante est appliquée à chaque fonction séparément, dans la limite du raisonnable. Si cela est
applicable, on tient compte de l’influence d’une fonction sur les autres fonctions.
Cette norme est une norme de famille de produits traitant de la sécurité d’appareils et a
préséance sur les normes horizontales et génériques couvrant le même sujet.
Un appareil conforme au texte de la présente norme ne sera pas nécessairement jugé
conforme aux principes de sécurité de la norme si, lorsqu'il est examiné et soumis aux essais,
il apparaît qu'il présente d'autres caractéristiques qui compromettent le niveau de sécurité
visé par ces prescriptions.
Un appareil utilisant des matériaux ou présentant des modes de construction différents de
ceux décrits dans les prescriptions de cette norme peut être examiné et essayé en fonction
de l'objectif poursuivi par ces prescriptions et, s'il est jugé pratiquement équivalent, il peut
être estimé conforme aux principes de sécurité de la norme.

60335-2-89 © IEC:2002 – 11 –
INTRODUCTION
It has been assumed in the drafting of this International standard that the execution of its

provisions is entrusted to appropriately qualified and experienced persons.

This standard recognizes the internationally accepted level of protection against hazards such

as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal

use taking into account the manufacturer's instructions. It also covers abnormal situations that

can be expected in practice.
This standard takes into account the requirements of IEC 60364 as far as possible so that

there is compatibility with the wiring rules when the appliance is connected to the supply mains.
However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered by
another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as
is reasonable. If applicable, the influence of one function on the other is taken into account.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
An appliance that complies with the text of this standard will not necessarily be considered to
comply with the safety principles of the standard if, when examined and tested, it is found to
have other features which impair the level of safety covered by these requirements.
An appliance employing materials or having forms of construction differing from those detailed
in the requirements of this standard may be examined and tested according to the intent of the
requirements and, if found to be substantially equivalent, may be considered to comply with the
standard.
– 12 – 60335-2-89  CEI:2002
APPAREILS ÉLECTRODOMESTIQUES
ET ANALOGUES – SÉCURITÉ –
Partie 2-89: Règles particulières pour les appareils de réfrigération

à usage commercial avec une unité de condensation du fluide frigorigène

ou un compresseur incorporés ou à distance

1 Domaine d'application
L'article de la Partie 1 est remplacé par l’article ci-après.
La présente partie de la CEI 600335 traite de la sécurité des appareils de réfrigération
électriques à usage commercial qui ont un compresseur incorporé ou qui sont fournis sous
forme de deux unités en vue d'un assemblage en un seul appareil conformément aux
instructions du fabricant (système à deux ensembles).
NOTE 101 Comme exemples d'appareils compris dans le domaine d'application de la présente norme, on peut
citer
− les présentoirs ou meubles de stockage réfrigérés;
− les chariots roulants réfrigérés;
− les comptoirs de service et comptoirs de self-service;
− les refroidisseurs à jet d'air et congélateurs à jet d'air.
Dans la mesure du possible, la présente norme traite des risques ordinaires présentés par
ces types d’appareils.
Elle ne traite pas des caractéristiques de construction et de fonctionnement des appareils de
réfrigération qui font l’objet de normes ISO.
NOTE 102 L'attention est attirée sur le fait que
− pour les appareils destinés à être utilisés dans des véhicules ou à bord de navires ou d'avions, des
prescriptions supplémentaires peuvent être nécessaires;
− dans de nombreux pays, des prescriptions supplémentaires sont spécifiées par les organismes nationaux de la
santé, par les organismes nationaux responsables de la protection des travailleurs, par les organismes
nationaux responsables de l’alimentation en eau, par les organismes nationaux responsables du transport, et
par des organismes similaires.
NOTE 103 La présente norme ne s'applique pas
− aux appareils de réfrigération à usage domestique (CEI 60335-2-24)

− aux systèmes de réfrigération industriels;
− aux moto-compresseurs (CEI 60335-2-34);
− aux distributeurs commerciaux avec ou sans moyen de paiement (CEI 60335-2-75);
− aux appareils à crème glacée à usage commercial;
− aux fabriques de glace à usage commercial;
− aux chambres froides;
− aux chambres réfrigérées multiples à compresseur à distance.

60335-2-89 © IEC:2002 – 13 –
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –

SAFETY –
Part 2-89: Particular requirements for commercial refrigerating appliances

with an incorporated or remote refrigerant condensing unit or compressor

1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 specifies safety requirements for electrically operated commercial
refrigerating appliances that have an incorporated compressor or that are supplied in two units
for assembly as a single appliance in accordance with the manufacturer’s instructions (split
system).
NOTE 101 Examples of appliances that are within the scope of this standard are
– refrigerated display and storage cabinets;
– refrigerated trolley cabinets;
– service counters and self-service counters;
– blast chillers and blast freezers.
As far as is practicable, this standard deals with the common hazards presented by these types
of appliances.
It does not cover those features of construction and operation of refrigerating appliances which
are dealt with in ISO standards.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be
necessary;
– in many countries additional requirements are specified by national health authorities, the national authorities
responsible for the protection of labour, national water authorities, the national authorities responsible for
transportation and similar authorities.
NOTE 103 This standard does not apply to
– domestic refrigerating appliances (IEC 60335-2-24)
– industrial refrigerating systems;

– motor-compressors (IEC 60335-2-34);
– commercial dispensing appliances and vending machines (IEC 60335-2-75);
– commercial ice-cream appliances;
– commercial ice makers;
– cold temperature rooms;
– multiple refrigerated chambers with a remote compressor.

– 14 – 60335-2-89  CEI:2002
2 Références normatives
L'article de la Partie 1 est applicable avec les exceptions suivantes.

Addition:
CEI/TR 60079 (toutes les parties), Matériel électrique pour atmosphères explosives gazeuses

CEI 60079-4, Matériel électrique pour atmosphères explosives gazeuses – Quatrième partie:

Méthode d'essai pour la détermination de la température d'inflammation

CEI 60079-4A, Matériel électrique pour atmosphères explosives gazeuses – Quatrième partie:
Méthode d'essai pour la détermination de la température d'inflammation
1)
CEI/TR 60079-15:1987 , Matériel électrique pour atmosphères explosives gazeuses –
Partie 15: Mode de protection «n»
CEI/TR3 60079-20, Matériel électrique pour atmosphères explosives gazeuses – Partie 20:
Données pour gaz et vapeurs inflammables, en relation avec l'utilisation des matériels
électriques
CEI 60335-2-5, Appareils électrodomestiques et analogues – Sécurité – Partie 2-5: Règles
particulières pour les lave-vaisselle
CEI 60335-2-34, Appareils électrodomestiques et analogues – Sécurité – Partie 2-34: Règles
particulières pour les moto-compresseurs
ISO 817, Fluides frigorigènes organiques – Désignation numérique
ISO 3864, Couleurs et signaux de sécurité
ISO 5149, Systèmes frigorifiques mécaniques utilisés pour le refroidissement et le chauffage
– Prescriptions de sécurité
3 Définitions
L'article de la Partie 1 est applicable avec les exceptions suivantes.

3.1.9 Remplacement:
conditions de fonctionnement normal
fonctionnement de l’appareil dans les conditions suivantes
les appareils de réfrigération sont mis en fonctionnement à une température ambiante
conformément au 5.7, à vide, avec les portes ou les couvercles fermés, les stores roulants
fermés ou ouverts, suivant le cas le plus défavorable. Les dispositifs de commande de
température réglables par l’utilisateur sont court-circuités ou rendus inopérants de n’importe
quelle autre façon. Les dispositifs de commutation, commandés par point de rosée ou par
horloge, sont mis sous ou hors tension, suivant le cas le plus défavorable.
———————
1)
La CEI/TR 60079-15, Ed. 1 (1987) a été remplacée par une deuxième édition, la CEI 60079-15 (2001), dont les
références ne correspondent plus aux références de la première édition citée ici. Il est prévu d’adapter la
présente norme à la CEI 60079-15 (2001) dans une future révision.

60335-2-89 © IEC:2002 – 15 –
2 Normative references
This clause of Part 1 is applicable except as follows:

Addition:
IEC 60079 (all parts), Electrical apparatus for explosive gas atmospheres

IEC 60079-4, Electrical apparatus for explosive gas atmospheres – Part 4: Method of test for

ignition temperatures
IEC 60079-4A, Electrical apparatus for explosive gas atmospheres – Part 4: Method of test for
ignition temperatures – First supplement
)
IEC/TR 60079-15:1987 , Electrical apparatus for explosive gas atmospheres – Part 15: Type
of protection " n "
IEC/TR3 60079-20, Electrical apparatus for explosive gas atmospheres – Part 20: Data for
flammable gases and vapours, relating to the use of electrical apparatus
IEC 60335-2-5, Household and similar electrical appliances – Safety – Part 2-5: Particular
requirements for dishwashers
IEC 60335-2-34, Household and similar electrical appliances – Safety – Part 2-34: Particular
requirements for motor-compressors
ISO 817, Organic refrigerants – Number designation
ISO 3864, Safety colours and safety signs
ISO 5149, Mechanical refrigerating systems used for cooling and heating – Safety
requirements
3 Definitions
This clause of Part 1 is applicable except as follows.
3.1.9 Replacement:
normal operation
operation of the appliance under the following conditions:
refrigerating appliances are operated at an ambient temperature in accordance with 5.7, empty,
with doors or lids closed, or roller blinds closed or open, whichever is the more unfavourable.
User adjustable temperature control devices are short-circuited or otherwise rendered
inoperative. Devices which are switched, by dew-point controls or clocks, are switched on or
off, whichever is the more unfavourable.
___________
IEC/TR 60079-15, Ed. 1 (1987) has been superseded by a second edition, IEC 60079-15 (2001), which no
longer corresponds to the references to the first edition cited here. It is foreseen to adapt the present standard
to IEC 60079-15 (2001) in a future revision.

– 16 – 60335-2-89  CEI:2002
Pour les appareils raccordés à une alimentation en eau, l'eau distincte de l'eau de

refroidissement est à une température de 15 °C ± 2 °C. L'eau de refroidissement est à la

température maximale spécifiée dans les instructions.

Pour les appareils à unité de condensation du fluide frigorigène séparée, l'unité de

condensation du fluide frigorigène est raccordée au meuble conformément aux instructions

du fabricant.
3.101
présentoir ou meuble de stockage réfrigéré

meuble fermé qui présente ou stocke des aliments congelés ou réfrigérés placés à l'intérieur

et qui est refroidi par une unité de condensation du fluide frigorigène

3.102
élément chauffant auxiliaire
dispositif de chauffage, tel que radiateur de dégivrage, réchauffeur de porte ou radiateur anti-
condensation, qui réalise une fonction auxiliaire
3.103
personne qualifiée
personne ayant reçu la formation technique appropriée et l'expérience nécessaire pour être
au courant des risques auxquels elle est exposée en réalisant une tâche et en prenant des
mesures nécessaires pour réduire le danger qui la menace ou celui encouru par d'autres
personnes
3.104
unité de condensation du fluide frigorigène
unité assemblée en usine pour réaliser une partie du cycle de réfrigération (compression et
condensation) comprenant un ou plusieurs compresseurs pour fluide frigorigène, des
moteurs, des condensateurs, des réservoirs de liquide, des tuyaux d'interconnexion et des
matériels auxiliaires, l’ensemble étant monté sur une base commune
3.105
fluide frigorigène inflammable
fluide frigorigène ayant une classification d'inflammabilité du groupe 2 ou 3, conformément à
l'ISO 5149
NOTE Pour les mélanges de fluides frigorigènes qui ont plus d'une classification d'inflammabilité, on prend, pour
les besoins de cette définition, la classification la plus défavorable.
3.106
espace libre
espace de volume supérieur à 60 l dans lequel un enfant peut être piégé et qui est accessible
après ouverture d'une porte, d'un couvercle ou d'un tiroir et enlèvement de toute partie

amovible interne, y compris les étagères, conteneurs ou tiroirs amovibles qui sont eux-
mêmes uniquement accessibles après l'ouverture d'une porte ou d'un couvercle. Pour calculer
le volume, on ne tient pas compte des espaces dont une des dimensions ne dépasse pas
150 mm ni des espaces à deux dimensions orthogonales dont chacune ne dépasse pas
200 mm.
4 Prescriptions générales
L'article de la Partie 1 est applicable avec l’exception suivante.
NOTE 101 L'utilisation de fluides frigorigènes inflammables entraîne quelques risques supplémentaires que ne
présentent pas les appareils utilisant des fluides frigorigènes ininflammables.
La présente norme aborde les risques dus à l'inflammation de fluide frigorigène inflammable, par suite de fuites,
provoquée par des sources potentielles d’inflammation associées à l'appareil.
Les risques dus à l'inflammation de fluide frigorigène inflammable, par suite de fuites, provoquée par une source
potentielle d’inflammation externe associée à l'environnement dans lequel est installé l'appareil, sont compensés
par la faible probabilité d'inflammation.

60335-2-89 © IEC:2002 – 17 –
For appliances connected to a water supply, the water other than cooling water, is at a

temperature of 15 °C ± 2 °C. The cooling water is at the maximum temperature specified in the

instruction.
For appliances with a separate refrigerant condensing unit, the refrigerant condensing unit

is connected to the cabinet in accordance with the manufacturer’s instructions.

3.101
refrigerated display and storage cabinet

enclosed cabinet which displays or stores chilled or frozen foodstuff placed therein and which

is cooled by a refrigerant condensing unit

3.102
ancillary heating element
heating device which performs an auxiliary function, such as a defrost heater, door heater or
anti-condensation heater
3.103
skilled person
person having the appropriate technical training and experience necessary to be aware of
hazards to which he or she is exposed in performing a task and of measures necessary to
minimize the danger to his or herself or other persons
3.104
refrigerant condensing unit
factory assembled unit for performing part of the refrigeration cycle (compression and
condensation) comprising one or more refrigerant compressors with motors, condensers, liquid
receivers, interconnecting pipe work and ancillary equipment, all mounted on a common base
3.105
flammable refrigerant
refrigerant with a flammability classification of group 2 or 3 in accordance with ISO 5149
NOTE For refrigerant blends which have more than one flammability classification, the most unfavourable
classification is taken for the purposes of this definition.
3.106
free space
space with a volume exceeding 60 l in wh
...


IEC 60335-2-89
Edition 1.2 2007-03
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –
Part 2-89: Particular requirements for commercial refrigerating appliances with
an incorporated or remote refrigerant condensing unit or compressor

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-89: Règles particulières pour les appareils de réfrigération à usage
commercial avec une unité de condensation du fluide frigorigène ou un
compresseur incorporés ou à distance

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by

any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or

IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.

Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette

publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60335-2-89
Edition 1.2 2007-03
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –
Part 2-89: Particular requirements for commercial refrigerating appliances with
an incorporated or remote refrigerant condensing unit or compressor

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-89: Règles particulières pour les appareils de réfrigération à usage
commercial avec une unité de condensation du fluide frigorigène ou un
compresseur incorporés ou à distance

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CQ
CODE PRIX
ICS 97.130.20 ISBN 2-8318-9029-2

– 2 – 60335-2-89 © CEI:2002+A1:2005

+A2:2007
SOMMAIRE
AVANT-PROPOS.6

INTRODUCTION.10

1 Domaine d'application .12

2 Références normatives.14

3 Définitions .14

4 Prescriptions générales .16
5 Conditions générales d'essais .18
6 Classification.20
7 Marquage et indications .20
8 Protection contre l'accès aux parties actives .26
9 Démarrage des appareils à moteur.26
10 Puissance et courant .26
11 Echauffements .28
12 Vacant.32
13 Courant de fuite et rigidité diélectrique à la température de régime .32
14 Surtensions transitoires.32
15 Résistance à l'humidité.32
16 Courant de fuite et rigidité diélectrique .34
17 Protection contre la surcharge des transformateurs et des circuits associés.34
18 Endurance.34
19 Fonctionnement anormal .36
20 Stabilité et dangers mécaniques .40
21 Résistance mécanique .40
22 Construction .40
23 Conducteurs internes .60
24 Composants .60
25 Raccordement au réseau et câbles souples extérieurs .60

26 Bornes pour conducteurs externes .62
27 Dispositions en vue de la mise à la terre .62
28 Vis et connexions .62
29 Distances dans l'air, lignes de fuite et isolation solide .62
30 Résistance à la chaleur et au feu.64
31 Protection contre la rouille.64
32 Rayonnement, toxicité et dangers analogues.64

Annexes .70
Annexe AA (normative) Essai à rotor bloqué des moteurs de ventilateurs.72
Annexe BB (normative) Matériel électrique "n" non producteur d'étincelles.76

60335-2-89 © IEC:2002+A1:2005 – 3 –

+A2:2007
CONTENTS
FOREWORD.7

INTRODUCTION.11

1 Scope.13

2 Normative references.15

3 Definitions .15

4 General requirement .17
5 General conditions for the tests.19
6 Classification .21
7 Marking and instructions .21
8 Protection against access to live parts .27
9 Starting of motor-operated appliances.27
10 Power input and current .27
11 Heating.29
12 Void.33
13 Leakage current and electric strength at operating temperature.33
14 Transient overvoltages.33
15 Moisture resistance.33
16 Leakage current and electric strength .35
17 Overload protection of transformers and associated circuits .35
18 Endurance .35
19 Abnormal operation.37
20 Stability and mechanical hazards .41
21 Mechanical strength.41
22 Construction .41
23 Internal wiring .61
24 Components .61
25 Supply connection and external flexible cords .61

26 Terminals for external conductors .63
27 Provision for earthing.63
28 Screw and connections .63
29 Creepage distances, clearances, and distances through insulation .63
30 Resistance to heat and fire .65
31 Resistance to rusting .65
32 Radiation, toxicity and similar hazards.65

Annexes.71
Annex AA (normative) Locked-rotor test of fan motors.73
Annex BB (normative) Non-sparking “n” electrical apparatus .75

– 4 – 60335-2-89 © CEI:2002+A1:2005

+A2:2007
Bibliographie.80

Figure 101 – Appareillage pour l’essai de débordement .66

Figure 102 – Détails de la pointe de l’outil à rayer .68

Figure AA.1 – Circuit d'alimentation pour l'essai à rotor bloqué d'un moteur de

ventilateur monophasé.74

Tableau 101 – Températures maximales pour les moto-compresseurs.30

Tableau 102 – Paramètres d'inflammabilité des fluides frigorigènes.56

60335-2-89 © IEC:2002+A1:2005 – 5 –

+A2:2007
Bibliography .79

Figure 101 – Apparatus for spillage test.67

Figure 102 – Scratching tool tip details .69

Figure AA.1 – Supply circuit for locked-rotor test of a single-phase fan motor .75

Table 101 – Maximum temperatures for motor-compressors.31

Table 102 – Refrigerant flammability parameters .57

– 6 – 60335-2-89 © CEI:2002+A1:2005

+A2:2007
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
APPAREILS ÉLECTRODOMESTIQUES
ET ANALOGUES – SÉCURITÉ –
Partie 2-89: Règles particulières pour les appareils de réfrigération

à usage commercial avec une unité de condensation du fluide frigorigène

ou un compresseur incorporés ou à distance

AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire

l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La présente partie de la Norme internationale CEI 60335 a été établie par le sous-comité 61C:
Appareils domestiques de réfrigération, du comité d'études 61 de la CEI: Sécurité des appareils
électrodomestiques et analogues.
La présente version consolidée de la CEI 60335-2-89 comprend la première édition (2002)
[documents 61C/208/FDIS et 61C/211/RVD], son amendement 1 (2005) [documents
61C/290/FDIS et 61C/301/RVD] et son amendement 2 (2007) [documents 61C/384/FDIS et
61C/389/RVD] et son corrigendum de juin 2005.
Le contenu technique de cette version consolidée est donc identique à celui de l'édition de
base et à ses amendements; cette version a été préparée par commodité pour l'utilisateur.
Elle porte le numéro d'édition 1.2.
Une ligne verticale dans la marge indique où la publication de base a été modifiée par les
amendements 1 et 2.
60335-2-89 © IEC:2002+A1:2005 – 7 –

+A2:2007
INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –

SAFETY –
Part 2-89: Particular requirements for commercial refrigerating appliances

with an incorporated or remote refrigerant condensing unit or compressor

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by subcommittee 61C:
Household appliances for refrigeration, of IEC technical committee 61: Safety of household and
similar electrical appliances.
This consolidated version of IEC 60335-2-89 consists of the first edition (2002) [documents
61C/208/FDIS and 61C/211/RVD], its amendment 1 (2005) [documents 61C/290/FDIS and
61C/301/RVD] and its amendment 2 (2007) [documents 61C/384/FDIS and 61C/389/RVD] and
its corrigendum of June 2005.
The technical content is therefore identical to the base edition and its amendments and has
been prepared for user convenience.
It bears the edition number 1.2.
A vertical line in the margin shows where the base publication has been modified by
amendments 1 and 2.
– 8 – 60335-2-89 © CEI:2002+A1:2005

+A2:2007
La présente partie 2 doit être utilisée conjointement avec la dernière édition de la CEI 60335-1 et
ses amendements. Elle a été établie sur la base de la quatrième édition (2001) de cette norme.

NOTE 1 L’expression « Partie 1 » utilisée dans la présente norme fait référence à la CEI 60335-1.

La présente partie 2 complète ou modifie les articles correspondants de la Partie 1 de la

CEI 60335-1 de façon à la transformer en norme CEI: Règles de sécurité pour les appareils

de réfrigération à usage commercial avec une unité de condensation du fluide frigorigène ou

un compresseur incorporés ou à distance.

Lorsqu'un paragraphe particulier de la Partie 1 n'est pas mentionné dans cette partie 2,

ce paragraphe s'applique pour autant qu'il est raisonnable. Lorsque la présente norme

spécifie «addition», «modification» ou «remplacement», le texte correspondant de la Partie 1

doit être adapté en conséquence.

NOTE 2 Le système de numérotation suivant est utilisé:
− paragraphes, tableaux et figures: ceux qui sont numérotés à partir de 101 sont complémentaires à ceux de la
Partie 1;
− notes: à l’exception de celles qui sont dans un nouveau paragraphe ou de celles qui concernent des notes de
la Partie 1, les notes sont numérotées à partir de 101, y compris celles des articles ou paragraphes qui sont
modifiés ou remplacés;
− annexes: les annexes complémentaires sont appelées AA, BB, etc.

NOTE 3 Les caractères d'imprimerie suivants sont utilisés:
− prescriptions: caractères romains;
− modalités d'essais: caractères italiques;
− notes: petits caractères romains.
Les mots en gras dans le texte sont définis à l'Article 3. Lorsqu'une définition concerne un adjectif, l'adjectif et le
nom associé figurent également en gras.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
60335-2-89 © IEC:2002+A1:2005 – 9 –

+A2:2007
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fourth edition (2001) of that standard.

NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.

This part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for commercial refrigerating
appliances with an incorporated or remote refrigerant condensing unit or compressor.

Where a particular subclause of Part 1 is not mentioned in this part 2, that subclause applies
as far as is reasonable. Where this standard states "addition", "modification” or "replacement",

the relevant text in Part 1 is to be adapted accordingly.

NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional annexes are lettered AA, BB, etc.

NOTE 3 The following print types are used:
– requirements: in roman type;
– test specifications: in italic type;
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the
associated noun are also in bold.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date,
the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 10 – 60335-2-89 © CEI:2002+A1:2005

+A2:2007
INTRODUCTION
Il a été considéré en établissant la présente Norme internationale que l'exécution de ses

dispositions était confiée à des personnes expérimentées et ayant une qualification

appropriée.
Cette norme reconnaît le niveau de protection internationalement accepté contre les risques

électriques, mécaniques, thermiques, liés au feu et au rayonnement des appareils, lorsqu'ils

fonctionnent comme en usage normal en tenant compte des instructions du fabricant. Elle

couvre également les situations anormales auxquelles on peut s'attendre dans la pratique et

prend en considération les phénomènes électromagnétiques qui peuvent affecter le

fonctionnement en toute sécurité des appareils.
Cette norme tient compte autant que possible des prescriptions de la CEI 60364, de façon à
rester compatible avec les règles d'installation quand l’appareil est raccordé au réseau
d’alimentation. Cependant, des règles nationales d'installation peuvent être différentes.
Si un appareil compris dans le domaine d’application de cette norme comporte également des
fonctions qui sont couvertes par une autre partie 2 de la CEI 60335, la partie 2 correspon-
dante est appliquée à chaque fonction séparément, dans la limite du raisonnable. Si cela est
applicable, on tient compte de l’influence d’une fonction sur les autres fonctions.
Lorsqu’une partie 2 ne comporte pas d’exigences complémentaires pour couvrir les risques
traités dans la Partie 1, la Partie 1 s’applique.
NOTE 1 Cela signifie que les comités d’études responsables pour les parties 2 ont déterminé qu’il n’était pas
nécessaire de spécifier des exigences particulières pour l’appareil en question en plus des exigences générales.
Cette norme est une norme de famille de produits traitant de la sécurité d’appareils et a
préséance sur les normes horizontales et génériques couvrant le même sujet.
NOTE 2 Les normes horizontales et génériques couvrant un risque ne sont pas applicables parce qu’elles ont
été prises en considération lorsque les exigences générales et particulières ont été étudiées pour la série de
normes CEI 60335. Par exemple, dans le cas des exigences de température de surface pour de nombreux
appareils, des normes génériques, comme l’ISO 13732-1 pour les surfaces chaudes, ne sont pas applicables en
plus de la Partie 1 ou des parties 2.
Un appareil conforme au texte de la présente norme ne sera pas nécessairement jugé
conforme aux principes de sécurité de la norme si, lorsqu'il est examiné et soumis aux essais,
il apparaît qu'il présente d'autres caractéristiques qui compromettent le niveau de sécurité
visé par ces prescriptions.
Un appareil utilisant des matériaux ou présentant des modes de construction différents de
ceux décrits dans les prescriptions de cette norme peut être examiné et essayé en fonction

de l'objectif poursuivi par ces prescriptions et, s'il est jugé pratiquement équivalent, il peut
être estimé conforme aux principes de sécurité de la norme.

60335-2-89 © IEC:2002+A1:2005 – 11 –

+A2:2007
INTRODUCTION
It has been assumed in the drafting of this International standard that the execution of its

provisions is entrusted to appropriately qualified and experienced persons.

This standard recognizes the internationally accepted level of protection against hazards such

as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal

use taking into account the manufacturer's instructions. It also covers abnormal situations that

can be expected in practice and takes into account the way in which electromagnetic

phenomena can affect the safe operation of appliances.

This standard takes into account the requirements of IEC 60364 as far as possible so that
there is compatibility with the wiring rules when the appliance is connected to the supply mains.
However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered by
another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as
is reasonable. If applicable, the influence of one function on the other is taken into account.
When a part 2 standard does not include additional requirements to cover hazards dealt with in
Part 1, Part 1 applies.
NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is
not necessary to specify particular requirements for the appliance in question over and above the general
requirements.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
NOTE 2 Horizontal and generic standards covering a hazard are not applicable since they have been taken into
consideration when developing the general and particular requirements for the IEC 60335 series of standards. For
example, in the case of temperature requirements for surfaces on many appliances, generic standards, such as
ISO 13732-1 for hot surfaces, are not applicable in addition to Part 1 or part 2 standards.
An appliance that complies with the text of this standard will not necessarily be considered to
comply with the safety principles of the standard if, when examined and tested, it is found to
have other features which impair the level of safety covered by these requirements.
An appliance employing materials or having forms of construction differing from those detailed
in the requirements of this standard may be examined and tested according to the intent of the
requirements and, if found to be substantially equivalent, may be considered to comply with the
standard.
– 12 – 60335-2-89 © CEI:2002+A1:2005

+A2:2007
APPAREILS ÉLECTRODOMESTIQUES
ET ANALOGUES – SÉCURITÉ –
Partie 2-89: Règles particulières pour les appareils de réfrigération

à usage commercial avec une unité de condensation du fluide frigorigène

ou un compresseur incorporés ou à distance

1 Domaine d'application
L'article de la Partie 1 est remplacé par l’article ci-après.
La présente partie de la CEI 600335 traite de la sécurité des appareils de réfrigération
électriques à usage commercial qui ont un compresseur incorporé ou qui sont fournis sous
forme de deux unités en vue d'un assemblage en un seul appareil conformément aux
instructions du fabricant (système à deux ensembles).
NOTE 101 Comme exemples d'appareils compris dans le domaine d'application de la présente norme, on peut
citer
− les présentoirs ou meubles de stockage réfrigérés;
− les chariots roulants réfrigérés;
− les comptoirs de service et comptoirs de self-service;
− les refroidisseurs à jet d'air et congélateurs à jet d'air.
Dans la mesure du possible, la présente norme traite des risques ordinaires présentés par
ces types d’appareils.
Elle ne traite pas des caractéristiques de construction et de fonctionnement des appareils de
réfrigération qui font l’objet de normes ISO.
NOTE 102 L'attention est attirée sur le fait que
− pour les appareils destinés à être utilisés dans des véhicules ou à bord de navires ou d'avions, des
prescriptions supplémentaires peuvent être nécessaires;
− dans de nombreux pays, des exigences supplémentaires sont spécifiées par les organismes nationaux.
NOTE 103 La présente norme ne s'applique pas
− aux appareils de réfrigération à usage domestique (CEI 60335-2-24)
− aux systèmes de réfrigération industriels;
− aux moto-compresseurs (CEI 60335-2-34);

− aux distributeurs commerciaux avec ou sans moyen de paiement (CEI 60335-2-75);
− aux appareils à crème glacée à usage commercial;
− aux fabriques de glace à usage commercial;
− aux chambres froides;
− aux chambres réfrigérées multiples à compresseur à distance.
NOTE 104 Les appareils dont la charge est supérieure à 150 g de fluide frigorigène inflammable dans chaque
circuit de réfrigération séparé ne sont pas couverts par la présente norme. Pour les appareils dont la charge est
supérieure à 150 g de fluide frigorigène inflammable dans chaque circuit de réfrigération et pour l'installation,
l'ISO 5149 peut être appliquée. En conséquence, la présente partie 2 ne permet pas d'évaluer la sécurité de tels
appareils.
60335-2-89 © IEC:2002+A1:2005 – 13 –

+A2:2007
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –

SAFETY –
Part 2-89: Particular requirements for commercial refrigerating appliances

with an incorporated or remote refrigerant condensing unit or compressor

1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 specifies safety requirements for electrically operated commercial
refrigerating appliances that have an incorporated compressor or that are supplied in two units
for assembly as a single appliance in accordance with the manufacturer’s instructions (split
system).
NOTE 101 Examples of appliances that are within the scope of this standard are
– refrigerated display and storage cabinets;
– refrigerated trolley cabinets;
– service counters and self-service counters;
– blast chillers and blast freezers.
As far as is practicable, this standard deals with the common hazards presented by these types
of appliances.
It does not cover those features of construction and operation of refrigerating appliances which
are dealt with in ISO standards.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be
necessary;
– in many countries, additional requirements are specified by national authorities.
NOTE 103 This standard does not apply to
– domestic refrigerating appliances (IEC 60335-2-24)
– industrial refrigerating systems;
– motor-compressors (IEC 60335-2-34);
– commercial dispensing appliances and vending machines (IEC 60335-2-75);

– commercial ice-cream appliances;
– commercial ice makers;
– cold temperature rooms;
– multiple refrigerated chambers with a remote compressor.
NOTE 104 Appliances with a charge of more than 150 g of flammable refrigerant in each separate refrigerant
circuit are not covered by this standard. For appliances with a charge greater than 150 g of flammable refrigerant
in each refrigerant circuit and for the installation, ISO 5149 may be applied. Consequently, such appliances cannot
be assessed for safety using this part 2.

– 14 – 60335-2-89 © CEI:2002+A1:2005

+A2:2007
2 Références normatives
L'article de la Partie 1 est applicable avec les exceptions suivantes.

Addition:
CEI/TR 60079 (toutes les parties), Matériel électrique pour atmosphères explosives gazeuses

CEI 60079-4, Matériel électrique pour atmosphères explosives gazeuses – Quatrième partie:

Méthode d'essai pour la détermination de la température d'inflammation

CEI 60079-4A, Matériel électrique pour atmosphères explosives gazeuses – Quatrième partie:
Méthode d'essai pour la détermination de la température d'inflammation
CEI 60079-15: 2005, Matériel électrique pour atmosphères explosives gazeuses – Partie 15:
Construction, essais et marquage des matériels électriques du mode de protection «n»
CEI/TR3 60079-20, Matériel électrique pour atmosphères explosives gazeuses – Partie 20:
Données pour gaz et vapeurs inflammables, en relation avec l'utilisation des matériels
électriques
CEI 60335-2-5, Appareils électrodomestiques et analogues – Sécurité – Partie 2-5: Règles
particulières pour les lave-vaisselle
CEI 60335-2-34, Appareils électrodomestiques et analogues – Sécurité – Partie 2-34: Règles
particulières pour les moto-compresseurs
ISO 817, Fluides frigorigènes organiques – Désignation numérique

ISO 5149, Systèmes frigorifiques mécaniques utilisés pour le refroidissement et le chauffage –
Prescriptions de sécurité
3 Définitions
L'article de la Partie 1 est applicable avec les exceptions suivantes.

3.1.9 Remplacement:
conditions de fonctionnement normal
fonctionnement de l’appareil dans les conditions suivantes
les appareils de réfrigération sont mis en fonctionnement à une température ambiante
conformément au 5.7, à vide, avec les portes ou les couvercles fermés, les stores roulants
fermés ou ouverts, suivant le cas le plus défavorable. Les dispositifs de commande de
température réglables par l’utilisateur sont court-circuités ou rendus inopérants de n’importe
quelle autre façon. Les dispositifs de commutation, commandés par point de rosée ou par
horloge, sont mis sous ou hors tension, suivant le cas le plus défavorable.

60335-2-89 © IEC:2002+A1:2005 – 15 –

+A2:2007
2 Normative references
This clause of Part 1 is applicable except as follows:

Addition:
IEC 60079 (all parts), Electrical apparatus for explosive gas atmospheres

IEC 60079-4, Electrical apparatus for explosive gas atmospheres – Part 4: Method of test for

ignition temperatures
IEC 60079-4A, Electrical apparatus for explosive gas atmospheres – Part 4: Method of test for
ignition temperatures – First supplement
IEC 60079-15: 2005, Electrical apparatus for explosive gas atmospheres – Part 15:
Construction, test and marking of type of protection "n" electrical apparatus
IEC/TR3 60079-20, Electrical apparatus for explosive gas atmospheres – Part 20: Data for
flammable gases and vapours, relating to the use of electrical apparatus
IEC 60335-2-5, Household and similar electrical appliances – Safety – Part 2-5: Particular
requirements for dishwashers
IEC 60335-2-34, Household and similar electrical appliances – Safety – Part 2-34: Particular
requirements for motor-compressors
ISO 817, Organic refrigerants – Number designation

ISO 5149, Mechanical refrigerating systems used
...


NORME CEI
INTERNATIONALE
IEC
60335-2-89
INTERNATIONAL
Edition 1.1
STANDARD
2005-04
Edition 1:2002 consolidée par l'amendement 1:2005
Edition 1:2002 consolidated with amendment 1:2005
Appareils électrodomestiques et analogues –
Sécurité –
Partie 2-89:
Règles particulières pour les appareils de
réfrigération à usage commercial avec une unité
de condensation du fluide frigorigène ou un
compresseur incorporés ou à distance

Household and similar electrical appliances –
Safety –
Part 2-89:
Particular requirements for commercial
refrigerating appliances with an incorporated
or remote refrigerant condensing unit
or compressor
Numéro de référence
Reference number
CEI/IEC 60335-2-89:2002+A1:2005

Numérotation des publications Publication numbering

Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are

sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For

devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.

Editions consolidées Consolidated editions

Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its

CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1

exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
60335-2-89
INTERNATIONAL
Edition 1.1
STANDARD
2005-04
Edition 1:2002 consolidée par l'amendement 1:2005
Edition 1:2002 consolidated with amendment 1:2005
Appareils électrodomestiques et analogues –
Sécurité –
Partie 2-89:
Règles particulières pour les appareils de
réfrigération à usage commercial avec une unité
de condensation du fluide frigorigène ou un
compresseur incorporés ou à distance

Household and similar electrical appliances –
Safety –
Part 2-89:
Particular requirements for commercial
refrigerating appliances with an incorporated
or remote refrigerant condensing unit
or compressor
 IEC 2005 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
W
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

– 2 – 60335-2-89  CEI:2002+A1:2005

SOMMAIRE
AVANT-PROPOS.6

INTRODUCTION.10

1 Domaine d'application .12

2 Références normatives.14

3 Définitions .14

4 Prescriptions générales .16
5 Conditions générales d'essais .18
6 Classification.20
7 Marquage et indications .20
8 Protection contre l'accès aux parties actives .26
9 Démarrage des appareils à moteur.26
10 Puissance et courant .26
11 Echauffements .28
12 Vacant.32
13 Courant de fuite et rigidité diélectrique à la température de régime .32
14 Surtensions transitoires.32
15 Résistance à l'humidité.32
16 Courant de fuite et rigidité diélectrique .34
17 Protection contre la surcharge des transformateurs et des circuits associés.34
18 Endurance.34
19 Fonctionnement anormal .36
20 Stabilité et dangers mécaniques .40
21 Résistance mécanique .40
22 Construction .40
23 Conducteurs internes .60
24 Composants .60
25 Raccordement au réseau et câbles souples extérieurs .60

26 Bornes pour conducteurs externes .62
27 Dispositions en vue de la mise à la terre .62
28 Vis et connexions .62
29 Distances dans l'air, lignes de fuite et isolation solide .62
30 Résistance à la chaleur et au feu.64
31 Protection contre la rouille.64
32 Rayonnement, toxicité et dangers analogues.64

Annexes .70
Annexe AA (normative) Essai à rotor bloqué des moteurs de ventilateurs.70
Annexe BB (normative) Matériel électrique "n" non producteur d'étincelles.74

60335-2-89 © IEC:2002+A1:2005 – 3 –

CONTENTS
FOREWORD.7

INTRODUCTION.11

1 Scope.13

2 Normative references.15

3 Definitions .15

4 General requirement .17
5 General conditions for the tests.19
6 Classification .21
7 Marking and instructions .21
8 Protection against access to live parts .27
9 Starting of motor-operated appliances.27
10 Power input and current .27
11 Heating.29
12 Void.33
13 Leakage current and electric strength at operating temperature.33
14 Transient overvoltages.33
15 Moisture resistance.33
16 Leakage current and electric strength .35
17 Overload protection of transformers and associated circuits .35
18 Endurance .35
19 Abnormal operation.37
20 Stability and mechanical hazards .41
21 Mechanical strength.41
22 Construction .41
23 Internal wiring .61
24 Components .61
25 Supply connection and external flexible cords .61

26 Terminals for external conductors .63
27 Provision for earthing.63
28 Screw and connections .63
29 Creepage distances, clearances, and distances through insulation .63
30 Resistance to heat and fire .65
31 Resistance to rusting .65
32 Radiation, toxicity and similar hazards.65

Annexes.71
Annex AA (normative) Locked-rotor test of fan motors.71
Annex BB (normative) Non-sparking “n” electrical apparatus .75

– 4 – 60335-2-89  CEI:2002+A1:2005

Bibliographie.78

Figure 101 – Appareillage pour l’essai de débordement .66

Figure 102 – Détails de la pointe de l’outil à rayer .68

Figure AA.1 – Circuit d'alimentation pour l'essai à rotor bloqué d'un moteur de

ventilateur monophasé.72

Tableau 101 – Températures maximales pour les moto-compresseurs.30

Tableau 102 – Paramètres d'inflammabilité des fluides frigorigènes.56

60335-2-89 © IEC:2002+A1:2005 – 5 –

Bibliography .79

Figure 101 – Apparatus for spillage test.67

Figure 102 – Scratching tool tip details .69

Figure AA.1 – Supply circuit for locked-rotor test of a single-phase fan motor .73

Table 101 – Maximum temperatures for motor-compressors.31

Table 102 – Refrigerant flammability parameters .57

– 6 – 60335-2-89  CEI:2002+A1:2005

COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
APPAREILS ÉLECTRODOMESTIQUES
ET ANALOGUES – SÉCURITÉ –
Partie 2-89: Règles particulières pour les appareils de réfrigération

à usage commercial avec une unité de condensation du fluide frigorigène

ou un compresseur incorporés ou à distance

AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications

référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La présente partie de la Norme internationale CEI 60335 a été établie par le sous-comité 61C:
Appareils domestiques de réfrigération, du comité d'études 61 de la CEI: Sécurité des appareils
électrodomestiques et analogues.
La présente version consolidée de la CEI 60335-2-89 est issue de la première édition (2002)
[documents 61C/208/FDIS et 61C/211/RVD], de son amendement 1 (2005) [documents
61C/290/FDIS et 61C/301/RVD] et du corrigendum de juin 2005.
Elle porte le numéro d'édition 1.1.
Une ligne verticale dans la marge indique où la publication de base a été modifiée par
l'amendement 1.
60335-2-89 © IEC:2002+A1:2005 – 7 –

INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –

SAFETY –
Part 2-89: Particular requirements for commercial refrigerating appliances

with an incorporated or remote refrigerant condensing unit or compressor

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by subcommittee 61C:
Household appliances for refrigeration, of IEC technical committee 61: Safety of household and
similar electrical appliances.
This consolidated version of IEC 60335-2-89 is based on the first edition (2002) [documents
61C/208/FDIS and 61C/211/RVD], its amendment 1 (2005) [documents 61C/290/FDIS and
61C/301/RVD] and its corrigendum of June 2005.
It bears the edition number 1.1.
A vertical line in the margin shows where the base publication has been modified by
amendment 1.
– 8 – 60335-2-89  CEI:2002+A1:2005

La présente partie 2 doit être utilisée conjointement avec la dernière édition de la CEI 60335-1 et
ses amendements. Elle a été établie sur la base de la quatrième édition (2001) de cette norme.

NOTE 1 L’expression « Partie 1 » utilisée dans la présente norme fait référence à la CEI 60335-1.

La présente partie 2 complète ou modifie les articles correspondants de la Partie 1 de la

CEI 60335-1 de façon à la transformer en norme CEI: Règles de sécurité pour les appareils

de réfrigération à usage commercial avec une unité de condensation du fluide frigorigène ou

un compresseur incorporés ou à distance.

Lorsqu'un paragraphe particulier de la Partie 1 n'est pas mentionné dans cette partie 2,

ce paragraphe s'applique pour autant qu'il est raisonnable. Lorsque la présente norme

spécifie «addition», «modification» ou «remplacement», le texte correspondant de la Partie 1

doit être adapté en conséquence.

NOTE 2 Le système de numérotation suivant est utilisé:
− paragraphes, tableaux et figures: ceux qui sont numérotés à partir de 101 sont complémentaires à ceux de la
Partie 1;
− notes: à l’exception de celles qui sont dans un nouveau paragraphe ou de celles qui concernent des notes de
la Partie 1, les notes sont numérotées à partir de 101, y compris celles des articles ou paragraphes qui sont
modifiés ou remplacés;
− annexes: les annexes complémentaires sont appelées AA, BB, etc.

NOTE 3 Les caractères d'imprimerie suivants sont utilisés:
− prescriptions: caractères romains;
− modalités d'essais: caractères italiques;
− notes: petits caractères romains.
Les mots en gras dans le texte sont définis à l'Article 3. Lorsqu'une définition concerne un adjectif, l'adjectif et le
nom associé figurent également en gras.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
60335-2-89 © IEC:2002+A1:2005 – 9 –

This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fourth edition (2001) of that standard.

NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.

This part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for commercial refrigerating
appliances with an incorporated or remote refrigerant condensing unit or compressor.

Where a particular subclause of Part 1 is not mentioned in this part 2, that subclause applies
as far as is reasonable. Where this standard states "addition", "modification” or "replacement",

the relevant text in Part 1 is to be adapted accordingly.

NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional annexes are lettered AA, BB, etc.

NOTE 3 The following print types are used:
– requirements: in roman type;
– test specifications: in italic type;
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the
associated noun are also in bold.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date,
the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 10 – 60335-2-89  CEI:2002+A1:2005

INTRODUCTION
Il a été considéré en établissant la présente Norme internationale que l'exécution de ses

dispositions était confiée à des personnes expérimentées et ayant une qualification

appropriée.
Cette norme reconnaît le niveau de protection internationalement accepté contre les risques

électriques, mécaniques, thermiques, liés au feu et au rayonnement des appareils, lorsqu'ils

fonctionnent comme en usage normal en tenant compte des instructions du fabricant. Elle

couvre également les situations anormales auxquelles on peut s'attendre dans la pratique et

prend en considération les phénomènes électromagnétiques qui peuvent affecter le

fonctionnement en toute sécurité des appareils.
Cette norme tient compte autant que possible des prescriptions de la CEI 60364, de façon à
rester compatible avec les règles d'installation quand l’appareil est raccordé au réseau
d’alimentation. Cependant, des règles nationales d'installation peuvent être différentes.
Si un appareil compris dans le domaine d’application de cette norme comporte également des
fonctions qui sont couvertes par une autre partie 2 de la CEI 60335, la partie 2 correspon-
dante est appliquée à chaque fonction séparément, dans la limite du raisonnable. Si cela est
applicable, on tient compte de l’influence d’une fonction sur les autres fonctions.
Cette norme est une norme de famille de produits traitant de la sécurité d’appareils et a
préséance sur les normes horizontales et génériques couvrant le même sujet.
Un appareil conforme au texte de la présente norme ne sera pas nécessairement jugé
conforme aux principes de sécurité de la norme si, lorsqu'il est examiné et soumis aux essais,
il apparaît qu'il présente d'autres caractéristiques qui compromettent le niveau de sécurité
visé par ces prescriptions.
Un appareil utilisant des matériaux ou présentant des modes de construction différents de
ceux décrits dans les prescriptions de cette norme peut être examiné et essayé en fonction
de l'objectif poursuivi par ces prescriptions et, s'il est jugé pratiquement équivalent, il peut
être estimé conforme aux principes de sécurité de la norme.

60335-2-89 © IEC:2002+A1:2005 – 11 –

INTRODUCTION
It has been assumed in the drafting of this International standard that the execution of its

provisions is entrusted to appropriately qualified and experienced persons.

This standard recognizes the internationally accepted level of protection against hazards such

as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal

use taking into account the manufacturer's instructions. It also covers abnormal situations that

can be expected in practice and takes into account the way in which electromagnetic

phenomena can affect the safe operation of appliances.

This standard takes into account the requirements of IEC 60364 as far as possible so that
there is compatibility with the wiring rules when the appliance is connected to the supply mains.
However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered by
another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as
is reasonable. If applicable, the influence of one function on the other is taken into account.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
An appliance that complies with the text of this standard will not necessarily be considered to
comply with the safety principles of the standard if, when examined and tested, it is found to
have other features which impair the level of safety covered by these requirements.
An appliance employing materials or having forms of construction differing from those detailed
in the requirements of this standard may be examined and tested according to the intent of the
requirements and, if found to be substantially equivalent, may be considered to comply with the
standard.
– 12 – 60335-2-89  CEI:2002+A1:2005

APPAREILS ÉLECTRODOMESTIQUES
ET ANALOGUES – SÉCURITÉ –
Partie 2-89: Règles particulières pour les appareils de réfrigération

à usage commercial avec une unité de condensation du fluide frigorigène

ou un compresseur incorporés ou à distance

1 Domaine d'application
L'article de la Partie 1 est remplacé par l’article ci-après.
La présente partie de la CEI 600335 traite de la sécurité des appareils de réfrigération
électriques à usage commercial qui ont un compresseur incorporé ou qui sont fournis sous
forme de deux unités en vue d'un assemblage en un seul appareil conformément aux
instructions du fabricant (système à deux ensembles).
NOTE 101 Comme exemples d'appareils compris dans le domaine d'application de la présente norme, on peut
citer
− les présentoirs ou meubles de stockage réfrigérés;
− les chariots roulants réfrigérés;
− les comptoirs de service et comptoirs de self-service;
− les refroidisseurs à jet d'air et congélateurs à jet d'air.
Dans la mesure du possible, la présente norme traite des risques ordinaires présentés par
ces types d’appareils.
Elle ne traite pas des caractéristiques de construction et de fonctionnement des appareils de
réfrigération qui font l’objet de normes ISO.
NOTE 102 L'attention est attirée sur le fait que
− pour les appareils destinés à être utilisés dans des véhicules ou à bord de navires ou d'avions, des
prescriptions supplémentaires peuvent être nécessaires;
− dans de nombreux pays, des prescriptions supplémentaires sont spécifiées par les organismes nationaux de la
santé, par les organismes nationaux responsables de la protection des travailleurs, par les organismes
nationaux responsables de l’alimentation en eau, par les organismes nationaux responsables du transport, et
par des organismes similaires.
NOTE 103 La présente norme ne s'applique pas
− aux appareils de réfrigération à usage domestique (CEI 60335-2-24)

− aux systèmes de réfrigération industriels;
− aux moto-compresseurs (CEI 60335-2-34);
− aux distributeurs commerciaux avec ou sans moyen de paiement (CEI 60335-2-75);
− aux appareils à crème glacée à usage commercial;
− aux fabriques de glace à usage commercial;
− aux chambres froides;
− aux chambres réfrigérées multiples à compresseur à distance.
NOTE 104 Les appareils dont la charge est supérieure à 150 g de fluide frigorigène inflammable dans chaque
circuit de réfrigération séparé ne sont pas couverts par la présente norme. Pour les appareils dont la charge est
supérieure à 150 g de fluide frigorigène inflammable dans chaque circuit de réfrigération et pour l'installation,
l'ISO 5149 peut être appliquée. En conséquence, la présente partie 2 ne permet pas d'évaluer la sécurité de tels
appareils.
60335-2-89 © IEC:2002+A1:2005 – 13 –

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –

SAFETY –
Part 2-89: Particular requirements for commercial refrigerating appliances

with an incorporated or remote refrigerant condensing unit or compressor

1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 specifies safety requirements for electrically operated commercial
refrigerating appliances that have an incorporated compressor or that are supplied in two units
for assembly as a single appliance in accordance with the manufacturer’s instructions (split
system).
NOTE 101 Examples of appliances that are within the scope of this standard are
– refrigerated display and storage cabinets;
– refrigerated trolley cabinets;
– service counters and self-service counters;
– blast chillers and blast freezers.
As far as is practicable, this standard deals with the common hazards presented by these types
of appliances.
It does not cover those features of construction and operation of refrigerating appliances which
are dealt with in ISO standards.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be
necessary;
– in many countries additional requirements are specified by national health authorities, the national authorities
responsible for the protection of labour, national water authorities, the national authorities responsible for
transportation and similar authorities.
NOTE 103 This standard does not apply to
– domestic refrigerating appliances (IEC 60335-2-24)
– industrial refrigerating systems;
– motor-compressors (IEC 60335-2-34);

– commercial dispensing appliances and vending machines (IEC 60335-2-75);
– commercial ice-cream appliances;
– commercial ice makers;
– cold temperature rooms;
– multiple refrigerated chambers with a remote compressor.
NOTE 104 Appliances with a charge of more than 150 g of flammable refrigerant in each separate refrigerant
circuit are not covered by this standard. For appliances with a charge greater than 150 g of flammable refrigerant
in each refrigerant circuit and for the installation, ISO 5149 may be applied. Consequently, such appliances cannot
be assessed for safety using this part 2.

– 14 – 60335-2-89  CEI:2002+A1:2005

2 Références normatives
L'article de la Partie 1 est applicable avec les exceptions suivantes.

Addition:
CEI/TR 60079 (toutes les parties), Matériel électrique pour atmosphères explosives gazeuses

CEI 60079-4, Matériel électrique pour atmosphères explosives gazeuses – Quatrième partie:

Méthode d'essai pour la détermination de la température d'inflammation

CEI 60079-4A, Matériel électrique pour atmosphères explosives gazeuses – Quatrième partie:
Méthode d'essai pour la détermination de la température d'inflammation
CEI 60079-15, Matériel électrique pour atmosphères explosives gazeuses – Partie 15:
Construction, essai et marquage des matériels électriques du mode de protection "n"
CEI/TR3 60079-20, Matériel électrique pour atmosphères explosives gazeuses – Partie 20:
Données pour gaz et vapeurs inflammables, en relation avec l'utilisation des matériels
électriques
CEI 60335-2-5, Appareils électrodomestiques et analogues – Sécurité – Partie 2-5: Règles
particulières pour les lave-vaisselle
CEI 60335-2-34, Appareils électrodomestiques et analogues – Sécurité – Partie 2-34: Règles
particulières pour les moto-compresseurs
ISO 817, Fluides frigorigènes organiques – Désignation numérique
ISO 3864, Couleurs et signaux de sécurité
ISO 5149, Systèmes frigorifiques mécaniques utilisés pour le refroidissement et le chauffage –
Prescriptions de sécurité
3 Définitions
L'article de la Partie 1 est applicable avec les exceptions suivantes.

3.1.9 Remplacement:
conditions de fonctionnement normal
fonctionnement de l’appareil dans les conditions suivantes
les appareils de réfrigération sont mis en fonctionnement à une température ambiante
conformément au 5.7, à vide, avec les portes ou les couvercles fermés, les stores roulants
fermés ou ouverts, suivant le cas le plus défavorable. Les dispositifs de commande de
température réglables par l’utilisateur sont court-circuités ou rendus inopérants de n’importe
quelle autre façon. Les dispositifs de commutation, commandés par point de rosée ou par
horloge, sont mis sous ou hors tension, suivant le cas le plus défavorable.
———————
Cette future troisième édition de la CEI 60079-15 est actuellement au stade FDIS et circule parmi les comités
nationaux.
60335-2-89 © IEC:2002+A1:2005 – 15 –

2 Normative references
This clause of Part 1 is applicable except as follows:

Addition:
IEC 60079 (all parts), Electrical apparatus for explosive gas atmospheres

IEC 60079-4, Electrical apparatus for explosive gas atmospheres – Part 4: Method of test for

ignition temperatures
IEC 60079-4A, Electrical apparatus for explosive gas atmospheres – Part 4: Method of test for
ignition temperatures – First supplement
IEC 60079-15: Electrical apparatus for explosive gas atmospheres – Part 15: Construction, test
and marking of type of protection, “n” electrical apparatus
IEC/TR3 60079-20, Electrical apparatus for explosive gas atmospheres – Part 20: Data for
flammable gases and vapours, relating to the use of electrical apparatus
IEC 60335-2-5, Household and similar electrical appliances – Safety – Part 2-5: Particular
requirements for dishwashers
IEC 60335-2-34, Household and similar electrical appliances – Safety – Part 2-34: Particular
requirements for motor-compressors
ISO 817, Organic refrigerants – Number designation
ISO 3864, Safety colours and safety signs
ISO 5149, Mechanical refrigerating systems used for cooling and heating – Safety
requirements
3 Definitions
This clause of Part 1 is applicable except as follows.
3.1.9 Replacement:
normal operation
operation of the appliance under the following conditions:
refrigerating appliances are operated at an ambient temperature in accordance with 5.7, empty,
with doors or lids closed, or roller blinds closed or open, whichever is the more unfavourable.
User adjustable temperature control devices are short-circuited or otherwise rendered
inoperativ
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...