IEC 60529:1989/AMD2:2013/COR1:2019
(Amendment)Corrigendum 1 - Amendment 2 - Degrees of protection provided by enclosures (IP Code)
Corrigendum 1 - Amendment 2 - Degrees of protection provided by enclosures (IP Code)
Corrigendum 1 - Amendement 2 - Degrés de protection procurés par les enveloppes (Code IP)
General Information
Relations
Standards Content (Sample)
IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60529 IEC 60529
Amendment 2 to Edition 2.0 2013-08 Amendement 2 à l'Édition 2.0 2013-08
DEGREES OF PROTECTION PROVIDED BY DEGRÉS DE PROTECTION PROCURÉS PAR LES
ENCLOSURES (IP CODE) ENVELOPPES (CODE IP)
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
6 Degrees of protection against ingress of water indicated by the second
characteristic numeral
After the instruction "Replace the seventh paragraph by the following", replace the text by the
following new text:
An enclosure designated with second characteristic numeral 7 or 8 only is considered
unsuitable for exposure to water jets (designated by second characteristic numeral 5 or 6) and
need not comply with requirements for numeral 5 or 6 unless it is multiple coded. An
enclosure designated with second characteristic numeral 9 only is considered unsuitable for
exposure to water jets (designated by second characteristic numeral 5 or 6) and immersion in
water (designated by second characteristic numeral
...