Corrigendum 2 - Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.

Corrigendum 2 - Travaux sous tension - Détecteurs de tension - Partie 2: Type résistif pour usage sur des tensions alternatives de 1 kV à 36 kV

General Information

Status
Published
Publication Date
22-Jul-1999
Technical Committee
TC 78 - Live working
Current Stage
PPUB - Publication issued
Start Date
21-Mar-2000
Completion Date
31-Mar-2000

Relations

Effective Date
05-Sep-2023
Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61243-2:1995/COR2:1999 - Corrigendum 2 - Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c. Released:7/23/1999

English and French language (10 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

Intertek Testing Services NA Inc.

Intertek certification services in North America.

ANAB United States Verified

NSF International

Global independent organization facilitating standards development and certification.

ANAB United States Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

IEC 61243-2:1995/COR2:1999 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 2 - Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.". This standard covers: Corrigendum 2 - Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.

Corrigendum 2 - Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c.

IEC 61243-2:1995/COR2:1999 is classified under the following ICS (International Classification for Standards) categories: 13.260 - Protection against electric shock. Live working; 29.240.20 - Power transmission and distribution lines; 29.260.99 - Other electrical equipment for working in special conditions. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61243-2:1995/COR2:1999 has the following relationships with other standards: It is inter standard links to IEC 61243-2:1995/COR1:1996, IEC 61243-2:1995. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61243-2:1995/COR2:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


Publication 61243-2 de la CEI IEC Publication 61243-2
(Première édition – 1995) (First edition – 1995)
Travaux sous tension – Détecteurs de tension – Live working – Voltage detectors –
Partie 2: Type résistif pour usage sur des Part 2: Resistive type to be used for voltages
tensions alternatives de 1 kV à 36 kV of 1 kV to 36 kV a.c.
CORRIGENDUM 2
Le comité technique 78 est toujours attentif à Technical committee 78 continues to monitor the
l'emploi en travaux sous tension de matériaux et de use of chemicals and materials in live working that
produits chimiques qui, tout en étant adéquats, are suitable and provide for safety, occupational
assurent la santé et la sécurité au travail ainsi que health and environmental protection. As a result,
la protection de l'environnement. En conséquence, a suitable solvent has been found to replace the
un solvant adéquat a été identifié pour remplacer le previously used trichloro-1,1,2 trifluoro-1,2,2 ethane
trichloro-1,1,2 trifluoro-1,2,2 éthane (aussi connu (also known as trifluorotrichloroethane, Freon and
sous les appellations trifluorotrichloroéthane, Fréon Refrigerant 113).
et Réfrigérant 113), utilisé au préalable.
Page 26 Page 27
5.1.3 Essais
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...