IEC 61347-2-8:2000/AMD1:2006/COR1:2012
(Amendment)Corrigendum 1 - Amendment 1 - Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps
Corrigendum 1 - Amendment 1 - Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps
Corrigendum 1 - Amendement 1 - Appareillages de lampes - Partie 2-8: Prescriptions particulières pour les ballasts pour lampes fluorescentes
General Information
Relations
Standards Content (Sample)
IEC 61347-2-8
(First edition – 2000 / Amendment 1:2006)
Lamp controlgear –
Part 2-8: Particular requirements for ballasts for fluorescent lamps
CO RRI G E NDUM 1
CONTENTS
Replace the existing title of Figure I.1 by the following:
Figure I.1 – Test circuit for magnetic controlgear, for lamps with integral starting devices
Figure I.1 – Test circuit for ballasts, for lamps with internal starting devices
Replace existing Figure I.1 by the following:
Key
1 Ammeter for measuring the d.c. current
2 Electrostatic voltmeter with a self-capacitance not exceeding 30 pF for measuring the pulse voltage
3 Protection device for power supply
4 Supply for switch control: optional
C = 0,66 μF
C = 5 000 pF
C = 50 pF
D = Diode ZD22
D = Diode IN4004
D = Diode (6 pieces) BYV96E
P Test sample
R Adjustable resistor (approximately 100 Ω)
R Adjustable resistor: R2 ≥ Ballast x 20
S Vacuum switch
Va Varistors (for selection see Annex I)
Figure I.1 – Test circuit for magnetic controlgear, for lamps with
integral starting devices
August 2012
CEI 61347-2-8
(Première édition – 2000 / Amendement 1:2006)
Appareillages de lampes –
Part 2-8: Pr
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.