Coaxial communication cables - Part 6: Sectional specification for CATV drop cables

IEC 61196-6:2009(E) applies to coaxial communications cables. It specifies the requirements for CATV drop cables for use in cabled television distribution networks operating at temperature between 40 °C and +70 °C and in the frequency range from 5 MHz to 1 000 MHz or from 5 MHz to 3 000 MHz.
This publication is to be read in conjunction with IEC 61196-1:2005.

General Information

Status
Published
Publication Date
11-Jan-2009
Technical Committee
Drafting Committee
Current Stage
DELPUB - Deleted Publication
Start Date
31-Jul-2020
Completion Date
27-Aug-2021
Ref Project

Relations

Buy Standard

Standard
IEC 61196-6:2009 - Coaxial communication cables - Part 6: Sectional specification for CATV drop cables
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 61196-6
Edition 1.0 2009-01
INTERNATIONAL
STANDARD
Coaxial communication cables –
Part 6: Sectional specification for CATV drop cables

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61196-6
Edition 1.0 2009-01
INTERNATIONAL
STANDARD
Coaxial communication cables –
Part 6: Sectional specification for CATV drop cables

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
L
ICS 33.120.10 ISBN 2-8318-1021-4
– 2 – 61196-6 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
COAXIAL COMMUNICATION CABLES –

Part 6: Sectional specification for CATV drop cables

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61196-6 has been prepared by subcommittee 46A: Coaxial cables,
of IEC technical committee 46: Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
46A/917/FDIS 46A/926/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This standard is to be read in conjunction with IEC 61196-1. It is based on the second edition
of that standard.
A list of all parts of IEC 61196 series, published under the general title Coaxial
communication cables, can be found on the IEC website.

61196-6 © IEC:2009(E) – 3 –
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

– 4 – 61196-6 © IEC:2009(E)
COAXIAL COMMUNICATION CABLES –

Part 6: Sectional specification for CATV drop cables

1 Scope
This part of IEC 61196 applies to coaxial communications cables. It specifies the
requirements for CATV drop cables for use in cabled television distribution networks operating
at temperature between −40 °C and +70 °C and in the frequency range from 5 MHz to
1 000 MHz or from 5 MHz to 3 000 MHz.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60068-1:1988, Environmental testing – Part 1: General and guidance
IEC 61196-1:2005, Coaxial communication cables – Part 1: Generic specification – General,
definitions and requirements
IEC 61196-1-1:2007,Coaxial communication cables – Part 1-1: Capability approval for coaxial
cables
IEC 61196-1-100 (all parts), Coaxial communication cables – Part 1-1XX: Electrical test
methods
IEC 61196-1-200 (all parts), Coaxial communication cables – Part 1-2XX: Environmental test
methods
IEC 61196-1-300 (all parts), Coaxial communication cables – Part 1-3XX: Mechanical test
methods
IEC 62153 (all parts), Metallic communication cable test methods
IEC 62230, Electric cables – Spark-test method
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61196-1 apply.
4 Materials and cable construction
4.1 Cable construction
The cable construction shall be in accordance with 4.2 to 4.6 of this standard and the
requirements stated in the relevant detail specification.

61196-6 © IEC:2009(E) – 5 –
4.2 Inner conductor
4.2.1 Conductor material
Subclause 4.4.1 of 61196-1 applies. The conductor material shall be stated in the relevant
detail specification.
4.2.2 Conductor construction
The conductor shall consist of a single wire or tube.
Subclause 4.4 of IEC 61196-1 applies.
The nominal diameter of the inner conductor and tolerance shall be stated in the relevant
detail specification.
The maximum allowable tolerance is ± 0,03 mm.
4.3 Dielectric
Subclause 4.5 of IEC 61196-1 applies.
The type, nominal diameter and tolerance along with the ovality and eccentricity of the
dielectric shall be stated in the relevant detail specification.
The maximum allowable tolerance of the diameter is ±0.15 mm. The maximum allowable
values for ovalityand eccentricity are given in 7.3, Table 4 of this standard.
Note: If the tape of the outer conductor is bonded to the dielectric the measurement shall be made over this tape.
4.4 Outer conductor or screen
The construction and material of the outer conductor or screen shall be as stated in the
relevant detail specification. The construction shall be in accordance with 4.6 f) or 4.6 g) of
IEC 61196-1.
The nominal diameter of the outer conductor or screen shall be stated in the relevant detail
specification.
The maximum allowable tolerance of the diameter is ±0.20 mm.
4.5 Sheath
Subclause 4.7 of IEC 61196-1, as amended by the following, applies:
Cables without an outer sheath shall not be subject to 4.5 of this standard.
The outer sheath of the cable shall be a thermoplastic material as specified in the relevant
detail specification.
The nominal sheath thickness shall be stated in the relevant detail specification.
...