IEC 61754-6:1997
(Main)Fibre optic connector interfaces - Part 6: Type MU connector family
General Information
- Abstract
Defines the standard interface dimensions for type MU family of connectors which is a miniature single-position plug characterized by a cylindrical, spring loaded butting ferrule and a push-pull coupling mechanism.
- Status
- Published
- Publication Date
- 06-Dec-2005
- Technical Committee
- SC 86B - Fibre optic interconnecting devices and passive components
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 22-Jul-2013
- Completion Date
- 28-Aug-2026
Buy Documents
IEC 61754-6:1997/COR1:1997 - Corrigendum 1 - Fibre optic connector interfaces - Part 6: Type MU connector family Released:9/10/1997
IEC 61754-6:1997 - Fibre optic connector interfaces - Part 6: Type MU connector family Released:5/30/1997
IEC 61754-6:1997+AMD1:2001 CSV - Fibre optic connector interfaces - Part 6: Type MU connector family Released:8/27/2001
IEC 61754-6:1997+AMD1:2001+AMD2:2004 CSV - Fibre optic connector interfaces - Part 6: Type MU connector family Released:12/7/2005
Overview
IEC 61754-6:1997 is an international standard published by the International Electrotechnical Commission (IEC) that defines the fibre optic connector interface dimensions for the type MU connector family. This standard is essential for ensuring consistent design, interoperability, and reliable physical connection of fibre optic connectors specifically of the MU type. The MU connector family features a compact, miniature single-position plug characterized by a cylindrical, spring-loaded butting ferrule and a push-pull coupling mechanism.
The document consolidates the original 1997 edition and subsequent amendments from 2001 and 2004, providing comprehensive details on the physical and mechanical interface specifications for these connectors. It supports manufacturers, designers, and users of fibre optic systems by establishing a clear, uniform framework for the MU connector family.
Key Topics
Connector Interface Dimensions
The standard precisely defines interface dimensions for various MU connector configurations including simplex and duplex plugs, adaptors, housings, and active device receptacles. Accurate dimensional guidelines ensure proper mating and optical alignment of connectors.Mechanical Design Features
The MU connector’s design includes a spring-loaded ferrule and a push-pull coupling mechanism, contributing to easy, reliable connectivity with good physical and optical performance. The standard provides detailed descriptions and specifications for these mechanical features.Alignment Elements
Specifications for resilient alignment sleeves and rigid bore alignment features are included, along with mechanical stops and gauge pin dimensions to ensure precision in fibre alignment, improving insertion loss and return loss performance.Variations and Configurations
The document covers single-position simplex and duplex connectors, multi-port adaptors (including up to 8-port adaptors), and different housing interfaces such as backplane, printed circuit boards, and active device receptacles. Annexes provide informative configurations of type MU-A and MU-B connector sets.Angled PC Connector Interfaces
An important section is dedicated to the MU angled Physical Contact (PC) connector variants that reduce back reflections and improve optical signal integrity in high-performance applications.
Applications
IEC 61754-6:1997 applies broadly to the telecommunications, data communications, and networking industries where high-density fibre optic interconnections are required in a compact form factor. Typical applications include:
- Optical fibre patch panels and cross-connect systems
- Telecommunications central offices and data centres
- Fibre to the home (FTTH) equipment
- Optical transceivers and active network devices
- High-density fibre optic modules and backplanes
By following this standard, manufacturers and system integrators can guarantee connector compatibility and system reliability, enhancing network performance while reducing installation and maintenance costs.
Related Standards
For comprehensive fibre optic connectivity, IEC 61754-6 should be used in conjunction with other related IEC standards:
- IEC 61754 Series – Defines a range of fibre optic connector interfaces, each part covering different connector families such as SC, FC, LC, ST, and others.
- IEC 60793 – Fibre optic cables and their performance specifications.
- IEC 61300 – Fibre optic test procedures, including mechanical and environmental testing of connectors.
- IEC 61755 – Fibre optic connector polish types and end-face geometry.
Cross-referencing these standards ensures a holistic approach to optical fibre network design, guaranteeing interoperability, quality assurance, and long-term system stability.
IEC 61754-6:1997 serves as a crucial guideline for engineering reliable, standardized MU-type fibre optic connectors. Its detailed dimensional and mechanical interface specifications facilitate seamless integration and optimal optical performance in demanding fibre optic infrastructures worldwide.
Relations
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
Buy Documents
IEC 61754-6:1997/COR1:1997 - Corrigendum 1 - Fibre optic connector interfaces - Part 6: Type MU connector family Released:9/10/1997
IEC 61754-6:1997 - Fibre optic connector interfaces - Part 6: Type MU connector family Released:5/30/1997
IEC 61754-6:1997+AMD1:2001 CSV - Fibre optic connector interfaces - Part 6: Type MU connector family Released:8/27/2001
IEC 61754-6:1997+AMD1:2001+AMD2:2004 CSV - Fibre optic connector interfaces - Part 6: Type MU connector family Released:12/7/2005
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
IEC 61754-6:1997 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Fibre optic connector interfaces - Part 6: Type MU connector family". This standard covers: Defines the standard interface dimensions for type MU family of connectors which is a miniature single-position plug characterized by a cylindrical, spring loaded butting ferrule and a push-pull coupling mechanism.
Defines the standard interface dimensions for type MU family of connectors which is a miniature single-position plug characterized by a cylindrical, spring loaded butting ferrule and a push-pull coupling mechanism.
IEC 61754-6:1997 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61754-6:1997 has the following relationships with other standards: It is inter standard links to IEC 61754-6:1997/AMD1:2001, IEC 61754-6:1997/AMD2:2004, IEC 61754-6:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61754-6:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Publication 61754-6 de la CEI
IEC Publication 61754-6
(Première édition - 1997)
(First edition - 1997)
Interfaces de connecteurs
Fibre optic connector interfaces
pour fibres optiques
Type MU connector family –Part 6:
Partie 6: Famille de
connecteurs de type MU
CORRIGENDUM 1
Page 8
Page 9
In the first table, between interface 6-4 and
Correction dans le texte anglais uniquement
interface 6-2:
instead of Not mate
read Mate
and equally, between interface 6-5 and
interface 6-2:
instead of Not mate read Mate
Page 11
Page 10
Figure 1
Figure 1
In the diagram Cross-section A
Dans le schéma Coupe -A:
transversale A-A:
instead of Coupling sleeve
au lieu de Manchon de couplage read Delatch housing
lire Boitier de
déverrouillage
Page 12
Page 13
Tableau 1
Table 1
Dans la note 2, première ligne:
au lieu de
In note 2, first line: instead of
coupling sleeve
Manchon de couplage lire Boitier de
déverrouillage
read Delatch housing
Page 14
Page 15
Figure 2
Figure 2
Comme en figure 1, dans le schéma Coupe
Same as in figure 1, in the diagram Cross-
transversale A-A:
section A-A:
au lieu de
Manchon de couplage lire Boitier de instead of Coupling sleeve
read Delatch housing
déverrouillage
Page 16
Page 17
Tableau 2
Table 2
A la
référence 1, sous dimensions, minimum, au
Reference 1, under dimensions, minimum,
lieu de 6,65 lire 6,55 afin d'unifier avec la 6,65
instead of rea
...
NORME CEI
INTERNATIONALE
IEC
61754-6
INTERNATIONAL
Première édition
STANDARD
First edition
1997-05
Interfaces de connecteurs pour fibres optiques –
Partie 6:
Famille de connecteurs de type MU
Fibre optic connector interfaces –
Part 6:
Type MU connector family
Numéro de référence
Reference number
CEI/IEC 61754-6: 1997
Validité de la présente publication Validity of this publication
Le contenu technique des publications de la CEI est cons- The technical content of IEC publications is kept under
tamment revu par la CEI afin qu'il reflète l'état actuel de constant review by the IEC, thus ensuring that the content
la technique. reflects current technology.
Des renseignements relatifs à la date de reconfirmation de Information relating to the date of the reconfirmation of the
la publication sont disponibles auprès du Bureau Central de publication is available from the IEC Central Office.
la CEI.
Les renseignements relatifs à ces révisions, à l'établis- Information on the revision work, the issue of revised
sement des éditions révisées et aux amendements peuvent editions and amendments may be obtained from IEC
être obtenus auprès des Comités nationaux de la CEI et National Committees and from the following IEC
dans les documents ci-dessous: sources:
• Bulletin de la CEI • IEC Bulletin
• Annuaire de la CEI • IEC Yearbook
Publié annuellement Published yearly
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
Terminologie Terminology
En ce qui concerne la terminologie générale, le lecteur se For general terminology, readers are referred to
reportera à la CEI 60050: Vocabulaire Electrotechnique IEC 60050: International Electrotechnical Vocabulary
International (VEI), qui se présente sous forme de chapitres (IEV), which is issued in the form of separate chapters
séparés traitant chacun d'un sujet défini. Des détails each dealing with a specific field. Full details of the IEV
complets sur le VEI peuvent être obtenus sur demande. will be supplied on request. See also the IEC
Voir également le dictionnaire multilingue de la CEI. Multilingual Dictionary.
Les termes et définitions figurant dans la présente publi- The terms and definitions contained in the present publi-
cation ont été soit tirés du VEI, soit spécifiquement cation have either been taken from the IEV or have been
approuvés aux fins de cette publication. specifically approved for the purpose of this publication.
Symboles graphiques et littéraux Graphical and letter symbols
Pour les symboles graphiques, les symboles littéraux et les For graphical symbols, and letter symbols and signs
signes d'usage général approuvés par la CEI, le lecteur approved by the IEC for general use, readers are referred to
consultera: publications:
– la CEI 60027: Symboles littéraux à utiliser en – IEC 60027: Letter symbols to be used in
électro-technique; electrical technology;
– la CEI 60417: Symboles graphiques utilisables – IEC 60417: Graphical symbols for use on
sur le matériel. Index, relevé et compilation des equipment. Index, survey and compilation of the
feuilles individuelles; single sheets;
– la CEI 60617: Symboles graphiques pour schémas; – IEC 60617: Graphical symbols for diagrams;
et pour les appareils électromédicaux, and for medical electrical equipment,
– la CEI 60878: Symboles graphiques pour – IEC 60878: Graphical symbols for
équipements électriques en pratique médicale. electromedical equipment in medical practice.
Les symboles et signes contenus dans la présente publi- The symbols and signs contained in the present publication
cation ont été soit tirés de la CEI 60027, de la CEI 60417, have either been taken from IEC 60027, IEC 60417,
de la CEI 60617 et/ou de la CEI 60878, soit spécifiquement IEC 60617 and/or IEC 60878, or have been specifically
approuvés aux fins de cette publication. approved for the purpose of this publication.
Publications de la CEI établies par le IEC publications prepared by the same
même comité d'études technical committee
L'attention du lecteur est attirée sur les listes figurant à la fin The attention of readers is drawn to the end pages of this
de cette publication, qui énumèrent les publications de la publication which list the IEC publications issued by the
CEI préparées par le comité d'études qui a établi la technical committee which has prepared the present
présente publication. publication.
NORME
CEI
INTERNATIONALE
IEC
61754-6
INTERNATIONAL
Première édition
STANDARD
First edition
1997-05
Interfaces de connecteurs pour fibres optiques –
Partie 6:
Famille de connecteurs de type MU
Fibre optic connector interfaces –
Part 6:
Type MU connector family
IEC 1997 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni utilisée No part of this publication may be reproduced or utilized in
sous quelque forme que ce soit et par aucun procédé, électronique any form or by any means, electronic or mechanical, including
ou mécanique, y compris la photocopie et les microfilms, sans photocopying and microfilm, without permission in writing from
l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE V
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
Publication 61754-6 de la CEI
IEC Publication 61754-6
(Première édition - 1997)
(First edition - 1997)
Interfaces de connecteurs
Fibre optic connector interfaces
pour fibres optiques
Type MU connector family –Part 6:
Partie 6: Famille de
connecteurs de type MU
CORRIGENDUM 1
Page 8
Page 9
In the first table, between interface 6-4 and
Correction dans le texte anglais uniquement
interface 6-2:
instead of Not mate
read Mate
and equally, between interface 6-5 and
interface 6-2:
instead of Not mate read Mate
Page 11
Page 10
Figure 1
Figure 1
In the diagram Cross-section A
Dans le schéma Coupe -A:
transversale A-A:
instead of Coupling sleeve
au lieu de Manchon de couplage read Delatch housing
lire Boitier de
déverrouillage
Page 12
Page 13
Tableau 1
Table 1
Dans la note 2, première ligne:
au lieu de
In note 2, first line: instead of
coupling sleeve
Manchon de couplage lire Boitier de
déverrouillage
read Delatch housing
Page 14
Page 15
Figure 2
Figure 2
Comme en figure 1, dans le schéma Coupe
Same as in figure 1, in the diagram Cross-
transversale A-A:
section A-A:
au lieu de
Manchon de couplage lire Boitier de instead of Coupling sleeve
read Delatch housing
déverrouillage
Page 16
Page 17
Tableau 2
Table 2
A la
référence 1, sous dimensions, minimum, au
Reference 1, under dimensions, minimum,
lieu de 6,65 lire 6,55 afin d'unifier avec la 6,65
instead of read 6,55 in order to harmonize
dimension 1 pour fiche simple en page 12
with dimension I for simplex plug on page 13
Dans la note 2, première
ligne, comme dans le In note 2, first line, same as in table 1: instead of
tableau 1: au lieu de
Manchon de couplage lire Coupling sleeve
read Delatch housing
Boîtier
de déverrouillage
Page 40
Page 41
Figure 8
Figure 8
Coupe transversale G-G
Cross-section G-G
Dans la partie supérieure gauche du schéma,
In the top left part of the diagram, add 5 mm to
prolonger de 5 mm le trait vertical qui limite la
the vertical line, limit for the dimension BU in
dimension BU pour obtenir* order to obtain:
!
I X
,BY
BU Bv
BW BX
BY
BX BY
BW
Backplane 67,
m
U
A11111^I I I I PN \W4__i7
var
^
---,.•^^^
U
w u-
Outer housing
¢ Boîtier extérieur
2PIILIST
a T
^F- f
Inner housing Boîtier intérieur 1)
^
IF--
Cross-section G-G
Coupe transversale G-G
Page 60
Page 61
Figure 11
Figure 11
Vue agrandie de E
Expanded view E
Dans la partie gauche du schéma, ajouter un trait
Add a vertical line with arrows to show
fléché vertical indiquant la dimension AR afin
dimension AR so as to obtain:
d'obtenir.
Carte imprimée
Printed board
Vue agrandie de E
Expanded view E
August 1997
Août 1997
– 2 – 61754-6 CEI:1997
SOMMAIRE
Pages
AVANT-PROPOS . 4
Articles
1 Domaine d'application . 6
2 Description. 6
3 Interfaces. 6
Figures et tableaux. 10 à 62
Annexes
A Configuration d'un jeu de connecteurs de type MU-A. 64
B Configuration d'un jeu de connecteurs de type MU-B. 66
61754-6 IEC:1997 – 3 –
CONTENTS
Page
FOREWORD . 5
Clause
1 Scope. 7
2 Description. 7
3 Interfaces . 7
Figures and tables. 11 to 63
Annexes
A Configuration of type MU-A connector set . 65
B Configuration of type MU-B connector set . 67
– 4 – 61754-6 CEI:1997
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
_________
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 6: Famille de connecteurs de type MU
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes Internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61754-6 a été établie par le sous-comité 86B: Dispositifs
d'interconnexion et composants passifs à fibres optiques, du comité d'études 86 de la CEI:
Fibres optiques.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
86B/881/FDIS 86B/983/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Les annexes A et B sont données uniquement à titre d'information.
61754-6 IEC:1997 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
_________
FIBRE OPTIC CONNECTOR INTERFACES −
Part 6: Type MU connector family
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61754-6 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/881/FDIS 86B/983/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annexes A and B are for information only.
– 6 – 61754-6 CEI:1997
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 6: Famille de connecteurs de type MU
1 Domaine d'application
La présente partie de la CEI 61754 définit les dimensions d'interfaces normalisées de la famille
de connecteurs de type MU.
2 Description
Le connecteur principal de la famille de connecteurs de type MU est une fiche miniature à
position unique caractérisée par un ou plusieurs embouts en butée à ressort cylindrique de
diamètre type égal à 1,25 mm et un mécanisme de couplage pousser/tirer. Le mécanisme
d'alignement optique des connecteurs est d'un type à trou rigide ou à manchon élastique.
3 Interfaces
La présente norme contient les interfaces normalisées suivantes.
Interface 6-1: Interface de connecteurs à fiches simples – Pousser/tirer
Interface 6-2: Interface de connecteurs à fiches doubles – Pousser/tirer
Interface 6-3: Interface de connecteurs à raccords simples – Pousser/tirer
Interface 6-4: Interface de connecteurs à raccords doubles – Pousser/tirer
Interface 6-5: Interface de connecteurs à raccords à 8 accès – Pousser/tirer
Interface 6-6: Interface de connecteurs à fiches – pour boîtiers de carte imprimée
Interface 6-7: Interface de support de manchon – pour boîtiers de carte imprimée
Interface 6-8: Interface de boîtier de fond de panier à 2 accès – Auto-rétention
Interface 6-9: Interface de boîtier de carte imprimée à 2 accès – Auto-rétention
Interface 6-10: Interface de boîtier de fond de panier à 8 accès – Auto-rétention
Interface 6-11: Interface de boîtier de carte imprimée à 8 accès – Auto-rétention
Les fiches des interfaces 6-1, 6-2 et 6-6 possèdent un ou plusieurs embouts à extrémité
sphérique polie, et établissent le contact physique.
La famille de connecteurs de type MU comprend deux types de jeux de connecteurs: jeu de
connecteurs MU-A (voir annexe A) et jeu de connecteurs MU-B (voir annexe B). Le jeu de
connecteurs MU-A est une configuration fiche-raccord à mécanisme de couplage pousser-tirer.
Le jeu de connecteurs MU-B est une configuration de connecteurs de fond de panier
enfichables, fiche/fond de panier et boîtiers de carte imprimée/fiche pour configuration boîtier
de carte imprimée/support de manchon et il est équipé d'un mécanisme d'auto-rétention.
Le jeu de connecteurs de type MU-A comporte des fiches simples et doubles, des raccords
simples, doubles et à 8 accès. Les fiches sont communes aux boîtiers de connecteurs de fond
de panier du jeu de connecteurs MU-B.
61754-6 IEC:1997 – 7 –
FIBRE OPTIC CONNECTOR INTERFACES –
Part 6: Type MU connector family
1 Scope
This part of IEC 61754 defines the standard interface dimensions for type MU family of
connectors.
2 Description
The parent connector for type MU connector family is a miniature single-position plug which is
characterized by a cylindrical, spring-loaded butting ferrule(s) of a 1,25 mm typical diameter,
and a push-pull coupling mechanism. The optical alignment mechanism of the connectors is of
a rigid hole or a resilient sleeve style.
3 Interfaces
This standard contains the following standard interfaces.
Interface 6-1: Simplex plug connector interface – Push/pull
Interface 6-2: Duplex plug connector interface – Push/pull
Interface 6-3: Simplex adaptor connector interface – Push/pull
Interface 6-4: Duplex adaptor connector interface – Push/pull
Interface 6-5: 8-port adaptor connector interface – Push/pull
Interface 6-6: Plug connector interface – for printed board housings
Interface 6-7: Sleeve holder interface – for printed board housings
Interface 6-8: 2-port backplane housing interface – Self-retentive
Interface 6-9: 2-port printed board housing interface – Self-retentive
Interface 6-10: 8-port backplane housing interface – Self-retentive
Interface 6-11: 8-port printed board housing interface – Self-retentive
The plugs of interfaces 6-1, 6-2 and 6-6 have a ferrule(s) with a spherically polished ferrule
endface, and realize physical contact.
The type MU connector family comprises two types of connector set: MU-A connector set (see
annex A) and MU-B connector set (see annex B). The MU-A connector set is a plug/adaptor
configuration with a push-pull coupling mechanism. The MU-B connector set is a plug-in type
back-plane connector configuration which is plug/backplane and printed board housings/plug
for printed board housing/sleeve holder configuration and is equipped with a self-retentive
mechanism.
The type MU-A connector set consists of simplex and duplex plugs, and simplex, duplex and 8-port
adaptors. The plugs are common to the backplane connector housings of the type MU-B connector
set.
– 8 – 61754-6 CEI:1997
Le jeu de connecteurs de type MU-B comprend des boîtiers de connecteurs fond de panier et
carte imprimée à 2 accès et à 8 accès, des fiches simples et doubles, une fiche pour boîtiers
de connecteurs de cartes imprimées, et un support de manchon. La fiche pour boîtier de
connecteur de carte imprimée est utilisée comme un jack avec le support de manchon. Le jack
est connecté au boîtier de connecteur carte imprimée.
Les interfaces normalisées suivantes sont interconnectables.
Raccords
Fiches
Interface 6-3 Interface 6-4 Interface 6-5
Interface 6-1 Accouplement Accouplement Accouplement
Interface 6-2 Pas d'accouplement Accouplement Accouplement
Boîtiers de connecteurs
Fiches Boîtier de connecteur fond de panier Boîtier de connecteur carte imprimée
Interface 6-8 Interface 6-10 Interface 6-9 Interface 6-11
Interface 6-1 Accouplement Accouplement Pas d'accouplement Pas d'accouplement
Interface 6-2 Accouplement Accouplement Pas d'accouplement Pas d'accouplement
Interface 6-6
avec Pas d'accouplement Pas d'accouplement Accouplement Accouplement
Interface 6-7
61754-6 IEC:1997 – 9 –
The type MU-B connector set consists of 2-port and 8-port backplane and printed board
connector housings, simplex and duplex plugs, plug for printed board connector housings, and
sleeve holder. The plug for printed board connector housing is used as a jack together with the
sleeve holder. The jack is attached into the printed board connector housing.
The following standard interfaces are intermateable.
Adaptors
Plugs
Interface 6-3 Interface 6-4 Interface 6-5
Interface 6-1 Mate Mate Mate
Interface 6-2 Not mate Not mate Not mate
Connector housings
Plugs Backplane connector housing Printed board connector housing
Interface 6-8 Interface 6-10 Interface 6-9 Interface 6-11
Interface 6-1 Mate Mate Not mate Not mate
Interface 6-2 Mate Mate Not mate Not mate
Interface 6-6
with Not Mate Not Mate Mate Mate
Interface 6-7
– 10 – 61754-6 CEI:1997
IEC 405/97
Figure 1 – Interface de connecteurs à fiches simples
61754-6 IEC:1997 – 11 –
IEC 405/97
Figure 1 – Simplex plug connector interface
– 12 – 61754-6 CEI:1997
Tableau 1 – Dimensions de l'interface de connecteurs à fiches simples
Dimensions
Référence Notes
Minimum Maximum
A 1,2485 mm 1,2495 mm 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1 mm 1,1 mm 2 et 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AA 4,3 mm 4,4 mm
AB 3,85 mm 3,95 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Rayon
AE 3 mm –
AF 2,2 mm 2,3 mm
EA 40° 45°
EB 10 mm 25 mm Rayon, 5
EC 0,45 mm 0,73 mm
NOTES
1 Un chanfrein ou rayon est autorisé jusqu'à une profondeur maximale de 0,5 mm par rapport à
la partie antérieure de l'embout.
2 Le manchon de couplage doit pouvoir être déplacé vers la droite et vers la gauche. Ces
dimensions sont indiquées lorsque le manchon de couplage est déplacé dans la position située
le plus à droite.
3 La dimension J est indiquée pour la partie antérieure de la fiche quand elle n'est pas
accouplée. On remarque que l'embout peut être déplacé par une certaine force de compression
axiale avec des extrémités en contact direct; la dimension J est par conséquent variable. La
force de compression de l'embout doit être comprise entre 5,5 N et 6,5 N lorsque la position de
la cible de référence optique à partir de la référence X est déplacée de 3,9 mm à 4,1 mm. De
plus, la dimension J doit se réduire en dessous de 3,25 mm avec une force de compression
axiale relativement importante.
4 La position du côté droit de Q doit devenir la position du côté gauche par rapport au plan
défini par la référence X lorsque le manchon de couplage est déplacé vers sa position située le
plus à gauche.
5 L'excentricité du dôme de la partie antérieure de l'embout sphérique poli doit être inférieure à
à 50 μm.
61754-6 IEC:1997 – 13 –
Table 1 – Dimensions of the simplex plug connector interface
Dimensions
Reference Notes
Minimum Maximum
A 1,2485 mm 1,2495 mm 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1 mm 1,1 mm 2 and 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AA 4,3 mm 4,4 mm
AB 3,85 mm 3,95 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Radius
AE 3 mm –
AF 2,2 mm 2,3 mm
EA 40° 45°
EB 10 mm 25 mm Radius, 5
EC 0,45 mm 0,73 mm
NOTES
1 A chamfer or radius is allowed to a maximum depth of 0,5 mm from the ferrule endface.
2 The coupling sleeve shall be movable toward the right and the left directions. These
dimensions are given when the coupling sleeve is moved in its most right-direction position.
3 The dimension J is given for the plug endface when not mated. It is noticed that the ferrule is
movable by a certain axial compression force with direct contacting endfaces, and therefore the
dimension J is variable. Ferrule compression force shall be 5,5 N to 6,5 N when the position of
the optical datum target from the datum X is moved in the range of 3,9 mm to 4,1 mm. In
addition, the dimension J shall become less than 3,25 mm with a relatively large axial
compression force.
4 The right-side position of Q shall become the left-side position to the plane defined by
datum X when the coupling sleeve is moved to its most left-direction position.
5 Dome eccentricity of the spherically polished ferrule endface shall be less than 50 μm.
– 14 – 61754-6 CEI:1997
IEC 406/97
Figure 2 – Interface de connecteurs à fiches doubles
61754-6 IEC:1997 – 15 –
IEC 406/97
Figure 2 – Duplex plug connector interface
– 16 – 61754-6 CEI:1997
Tableau 2 – Dimensions de l'interface de connecteurs à fiches doubles
Dimensions
Référence Notes
Minimum Maximum
A 1,2485 mm 1,2495 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,65 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1,0 mm 1,1 mm 2 et 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AB 3,7 mm 3,85 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Rayon
AE 3,0 mm –
AF 2,2 mm 2,3 mm
AJ 8,8 mm 8,9 mm
AK 8,35 mm 8,45 mm
AL 4,55 mm 4,7 mm
AM 4,45 mm 4,55 mm
AP – 3,7 mm
EA 40° 45°
EB 10 mm 25 mm Rayon, 5
EC 0,45 mm 0,73 mm
NOTES
1 Un chanfrein ou rayon est autorisé jusqu'à une profondeur maximale de 0,5 mm par rapport à
la partie antérieure de l'embout.
2 Le manchon de couplage doit pouvoir être déplacé vers la droite et vers la gauche. Ces
dimensions sont indiquées lorsque le manchon de couplage est déplacé dans la position située
le plus à droite.
3 La dimension J est indiquée pour la partie antérieure de la fiche quand elle n'est pas
accouplée. On remarque que l'embout peut être déplacé par une certaine force de compression
axiale avec des extrémités en contact direct; la dimension J est par conséquent variable. La
force de compression de l'embout doit être comprise entre 5,5 N et 6,5 N lorsque la position de
la cible de référence optique à partir de la référence X est déplacée de 3,9 mm à 4,1 mm. De
plus, la dimension J doit se réduire en dessous de 3,25 mm avec une force de compression
axiale relativement importante.
4 La position du côté droit de Q doit devenir la position du côté gauche par rapport au plan
défini par la référence X lorsque le manchon de couplage est déplacé vers sa position située la
plus à gauche.
5 L'excentricité du dôme de la partie antérieure de l'embout sphérique poli doit être inférieure à
50 μm.
61754-6 IEC:1997 – 17 –
Table 2 – Dimensions of the duplex plug connector interface
Dimensions
Reference Notes
Minimum Maximum
A 1,2485 mm 1,2495 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,65 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1,0 mm 1,1 mm 2 and 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AB 3,7 mm 3,85 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Radius
AE 3,0 mm –
AF 2,2 mm 2,3 mm
AJ 8,8 mm 8,9 mm
AK 8,35 mm 8,45 mm
AL 4,55 mm 4,7 mm
AM 4,45 mm 4,55 mm
AP – 3,7 mm
EA 40° 45°
EB 10 mm 25 mm Radius, 5
EC 0,45 mm 0,73 mm
NOTES
1 A chamfer or radius is allowed to a maximum depth of 0,5 mm from the ferrule endface.
2 The coupling sleeve shall be movable toward the right and the left directions. These
dimensions are given when the coupling sleeve is moved in its most right-direction position.
3 The dimension J is given for the plug endface when not mated. It is noticed that the ferrule is
movable by a certain axial compression force with direct contacting endfaces, and therefore the
dimension J is variable. Ferrule compression force shall be 5,5 N to 6,5 N when the position of
the optical datum target from the datum X is moved in the range of 3,9 mm to 4,1 mm. In
addition, the dimension J shall become less than 3,25 mm with a relatively large axial
compression force.
4 The right-side position of Q shall become left-side position to the plane defined by datum X
when the coupling sleeve is m
...
NORME CEI
INTERNATIONALE IEC
61754-6
INTERNATIONAL
Edition 1.1
STANDARD
2001-08
Edition 1:1997 consolidée par l'amendement 1:2001
Edition 1:1997 consolidated with amendment 1:2001
Interfaces de connecteurs pour fibres optiques –
Partie 6:
Famille de connecteurs de type MU
Fibre optic connector interfaces –
Part 6:
Type MU connector family
Numéro de référence
Reference number
CEI/IEC 61754-6:1997+A1:2001
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/catlg-f.htm) vous permet de faire des (www.iec.ch/catlg-e.htm) enables you to search
recherches en utilisant de nombreux critères, by a variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations line information is also available on recently
en ligne sont également disponibles sur les issued publications, withdrawn and replaced
nouvelles publications, les publications rempla- publications, as well as corrigenda.
cées ou retirées, ainsi que sur les corrigenda.
• IEC Just Published
• IEC Just Published
Ce résumé des dernières publications parues
This summary of recently issued publications
(www.iec.ch/JP.htm) est aussi disponible par
(www.iec.ch/JP.htm) is also available by email.
courrier électronique. Veuillez prendre contact
Please contact the Customer Service Centre (see
avec le Service client (voir ci-dessous) pour plus
below) for further information.
d’informations.
• Service clients
• Customer Service Centre
Si vous avez des questions au sujet de cette
If you have any questions regarding this
publication ou avez besoin de renseignements
publication or need further assistance, please
supplémentaires, prenez contact avec le Service
contact the Customer Service Centre:
clients:
Email: custserv@iec.ch
Email: custserv@iec.ch
Tél: +41 22 919 02 11
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
61754-6
INTERNATIONAL
Edition 1.1
STANDARD
2001-08
Edition 1:1997 consolidée par l'amendement 1:2001
Edition 1:1997 consolidated with amendment 1:2001
Interfaces de connecteurs pour fibres optiques –
Partie 6:
Famille de connecteurs de type MU
Fibre optic connector interfaces –
Part 6:
Type MU connector family
IEC 2001 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photocopie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
CN
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61754-6 CEI:1997+A1:2001
SOMMAIRE
AVANT-PROPOS.6
1 Domaine d'application .8
2 Description .8
3 Interfaces .8
Annexe A (informative) Configuration d'un jeu de connecteurs de type MU-A .82
Annexe B (informative) Configuration d'un jeu de connecteurs de type MU-B .84
Figure 1 – Interface de connecteurs à fiches simples.12
Figure 2 – Interface de connecteurs à fiches doubles.16
Figure 3a – Interface de connecteurs à raccords simples.20
Figure 3b – Pointe de calibrage pour manchon d'alignement élastique.24
Figure 4a – Interface de connecteurs à raccords doubles .26
Figure 5a – Interface de connecteurs à raccords à 8 accès.26
Figure 4b – Pointe de calibrage pour manchon d'alignement élastique.30
Figure 5b – Pointe de calibrage pour manchon d'alignement élastique.30
Figure 5c – Interface de connecteurs à raccords à 8 accès.30
Figure 6 – Interface de connecteurs à fiches.32
Figure 7a – Interface de support de manchon .36
Figure 7b – Pointe de calibrage pour manchon d'alignement élastique.38
Figure 8 – Interface de boîtier de fond de panier à 2 accès.40
Figure 9 – Interface de boîtier de carte imprimée à 2 accès .46
Figure 10 – Interface de boîtier de fond de panier à 8 accès.52
Figure 11 – Interface de boîtier de carte imprimée à 8 accès .60
Figure 12a – Interface d’embase monovoie de dispositif actif.64
Figure 12b – Détail de l’arrêt mécanique pour un élément d’alignement à trou rigide .70
Figure 12c – Calibre pour manchon d’alignement élastique.72
Figure 13a – Interface d’embase double de dispositif actif .74
Figure 13b – Détail de l’arrêt mécanique pour un élément d’alignement à trou rigide .78
Figure 13c – Calibre pour manchon d’alignement élastique.80
Tableau 1 – Dimensions de l'interface de connecteurs à fiches simples .14
Tableau 2 – Dimensions de l'interface de connecteurs à fiches doubles.18
Tableau 3a – Dimensions de l'interface de connecteurs à raccords simples.22
Tableau 3b – Degré .22
Tableau 3c – Dimensions de la pointe de calibrage.24
Tableau 4a – Dimensions de l'interface de connecteurs à raccords doubles.28
Tableau 5a – Dimensions de l'interface de connecteurs à raccords à 8 accès.28
Tableau 4b – Degré .28
61754-6 IEC:1997+A1:2001 – 3 –
CONTENTS
FOREWORD.7
1 Scope.9
2 Description .9
3 Interfaces .9
Annex A (informative) Configuration of type MU-A connector set .83
Annex B (informative) Configuration of type MU-B connector set .85
Figure 1 – Simplex plug connector interface .13
Figure 2 – Duplex plug connector interface .17
Figure 3a – Simplex adaptor connector interface .21
Figure 3b – Gauge pin for resilient alignment sleeve.25
Figure 4a – Duplex adaptor connector interface .27
Figure 5a – 8-port adaptor connector interface.27
Figure 4b – Gauge pin for resilient alignment sleeve.31
Figure 5b – Gauge pin for resilient alignment sleeve.31
Figure 5c – 8-port adaptor connector interface.31
Figure 6 – Plug connector interface .33
Figure 7a – Sleeve holder interface .37
Figure 7b – Gauge pin for resilient alignment sleeve.39
Figure 8 – 2-port backplane housing interface.41
Figure 9 – 2-port printed board housing interface.47
Figure 10 – 8-port backplane housing interface.53
Figure 11 – 8-port printed board housing interface.61
Figure 12a – Simplex active device receptacle interface .65
Figure 12b – Detail of the mechanical stop for rigid bore alignment feature.71
Figure 12c – Pin gauge for the resilient alignment sleeve.73
Figure 13a – Duplex active device receptacle interface.75
Figure 13b – Detail of the mechanical stop for rigid bore alignment feature.79
Figure 13c – Pin gauge for the resilient alignment sleeve.81
Table 1 – Dimensions of the simplex plug connector interface .15
Table 2 – Dimensions of the duplex plug connector interface.19
Table 3a – Dimensions of the simplex adaptor connector interface .23
Table 3b – Grade.23
Table 3c – Gauge pin dimensions .25
Table 4a – Dimensions of the duplex adaptor connector interface.29
Table 5a – Dimensions of the 8-port adaptor connector interface.29
Table 4b – Grade.29
– 4 – 61754-6 CEI:1997+A1:2001
Tableau 5b – Degré .28
Tableau 4c – Dimensions de la pointe de calibrage.30
Tableau 5c – Dimensions de la pointe de calibrage.30
Tableau 5d – Dimensions de l'interface de connecteurs à raccords à 8 accès.30
Tableau 6 – Dimensions de l'interface de connecteurs à fiches.34
Tableau 7a – Dimensions de l'interface de support de manchon .36
Tableau 7b – Degré .38
Tableau 7c – Dimensions de la pointe de calibrage.38
Tableau 8a – Dimensions de l'interface de boîtier de fond de panier à 2 accès .44
Tableau 8b – Degré .46
Tableau 9 – Dimensions de l'interface de boîtier de carte imprimée à 2 accès .50
Tableau 10a – Dimensions de l'interface de boîtier de fond de panier à 8 accès .56
Tableau 10b – Degré .58
Tableau 11 – Dimensions de l'interface de boîtier de carte imprimée à 8 accès .66
Tableau 12a – Dimensions de l’interface d’embase monovoie de dispositif actif.68
Tableau 12b – Variantes de l’élément d’alignement .70
Tableau 12c – Dimensions de l’arrêt mécanique pour un élément d’alignement
à trou rigide .70
Tableau 12d – Variantes de l’élément d’arrêt mécanique .72
Tableau 12e – Dimensions du calibre .72
Tableau 13a – Dimensions de l’interface d’embase double de dispositif actif .76
Tableau 13b – Variantes de l’élément d’alignement .78
Tableau 13c – Dimensions de l’arrêt mécanique pour un élément d’alignement
à trou rigide .78
Tableau 13d – Variantes de l’élément d’arrêt mécanique .80
Tableau 13e – Dimensions du calibre .80
61754-6 IEC:1997+A1:2001 – 5 –
Table 5b – Grade.29
Table 4c – Gauge pin dimensions .31
Table 5c – Gauge pin dimensions .31
Table 5d – Dimensions of the 8-port adaptor connector interface.31
Table 6 – Dimensions of the plug connector interface .35
Table 7a – Dimensions of the sleeve holder interface .37
Table 7b – Grade.39
Table 7c – Gauge pin dimensions .39
Table 8a – Dimensions of the 2-port backplane housing interface .45
Table 8b – Grade.47
Table 9 – Dimensions of the 2-port printed board housing interface .51
Table 10a – Dimensions of the 8-port backplane housing interface .57
Table 10b – Grade.59
Table 11 – Dimensions of the 8-port printed board housing interface .67
Table 12a – Dimensions of the simplex active device receptacle interface .69
Table 12b – Alignment feature grade .71
Table 12c – Dimensions of the mechanical stop for rigid bore alignment feature .71
Table 12d – Mechanical stop feature grade.73
Table 12e – Pin gauge dimensions .73
Table 13a – Dimensions of the duplex active device receptacle interface.77
Table 13b – Alignment feature grade .79
Table 13c – Dimensions of the mechanical stop for rigid bore alignment feature .79
Table 13d – Mechanical stop feature grade.81
Table 13e – Pin gauge dimensions .81
– 6 – 61754-6 CEI:1997+A1:2001
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 6: Famille de connecteurs de type MU
AVANT-PROPOS
1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes
internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national
intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement
avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les
deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les
Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence
La Norme internationale CEI 61754-6 a été établie par le sous-comité 86B: Dispositifs
d'interconnexion et composants passifs à fibres optiques, du comité d'études 86 de la CEI:
Fibres optiques.
La présente version consolidée de la CEI 61754-6 est issue de la première édition (1997)
[documents 86B/881/FDIS et 86B/983/RVD], de son amendement 1 (2001) [documents
86B/1402/FDIS et 86B/1455/RVD] et du corrigendum d'août 1997.
Elle porte le numéro d'édition 1.1.
Une ligne verticale dans la marge indique où la publication de base a été modifiée par
l'amendement 1 et le corrigendum.
Les annexes A et B sont données uniquement à titre d'information.
Le comité a décidé que le contenu de la publication de base et de son amendement ne sera
pas modifié avant 2002. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
61754-6 IEC:1997+A1:2001 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC CONNECTOR INTERFACES –
Part 6: Type MU connector family
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61754-6 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
This consolidated version of IEC 61754-6 is based on the first edition (1997) [documents
86B/881/FDIS and 86B/983/RVD], its amendment 1 (2001) [documents 86B/1402/FDIS and
86B/1455/RVD], and the corrigendum of August 1997.
It bears the edition number 1.1.
A vertical line in the margin shows where the base publication has been modified by
amendment 1 and the corrigendum.
Annexes A and B are for information only.
The committee has decided that the contents of the base publication and its amendment will
remain unchanged until 2002. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 8 – 61754-6 CEI:1997+A1:2001
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 6: Famille de connecteurs de type MU
1 Domaine d'application
La présente partie de la CEI 61754 définit les dimensions d'interfaces normalisées de la
famille de connecteurs de type MU.
2 Description
Le connecteur principal de la famille de connecteurs de type MU est une fiche miniature à
position unique caractérisée par un ou plusieurs embouts en butée à ressort cylindrique de
diamètre type égal à 1,25 mm et un mécanisme de couplage pousser/tirer. Le mécanisme
d'alignement optique des connecteurs est d'un type à trou rigide ou à manchon élastique.
La présente partie 6, relative à la famille des connecteurs de type MU, définit les dimensions
des interfaces normalisées des embases de dispositifs actifs pour les connecteurs de type MU.
Les embases sont utilisées pour retenir les connecteurs à fiche et pour maintenir
mécaniquement la cible de référence optique des fiches dans une position définie à l’intérieur
des boîtiers d’embases.
3 Interfaces
La présente norme contient les interfaces normalisées suivantes.
Interface 6-1: Interface de connecteurs à fiches simples – Pousser/tirer
Interface 6-2: Interface de connecteurs à fiches doubles – Pousser/tirer
Interface 6-3: Interface de connecteurs à raccords simples – Pousser/tirer
Interface 6-4: Interface de connecteurs à raccords doubles – Pousser/tirer
Interface 6-5: Interface de connecteurs à raccords à 8 accès – Pousser/tirer
Interface 6-6: Interface de connecteurs à fiches – pour boîtiers de carte imprimée
Interface 6-7: Interface de support de manchon – pour boîtiers de carte imprimée
Interface 6-8: Interface de boîtier de fond de panier à 2 accès – Auto-rétention
Interface 6-9: Interface de boîtier de carte imprimée à 2 accès – Auto-rétention
Interface 6-10: Interface de boîtier de fond de panier à 8 accès – Auto-rétention
Interface 6-11: Interface de boîtier de carte imprimée à 8 accès – Auto-rétention
Interface 6-12: Interface d’embase monovoie de dispositif actif – pour connecteur à fiche
à contact PC
Interface 6-13: Interface d’embase double de dispositif actif – pour connecteur à fiche
à contact PC
Les fiches des interfaces 6-1, 6-2 et 6-6 possèdent un ou plusieurs embouts à extrémité
sphérique polie, et établissent le contact physique.
61754-6 IEC:1997+A1:2001 – 9 –
FIBRE OPTIC CONNECTOR INTERFACES –
Part 6: Type MU connector family
1 Scope
This part of IEC 61754 defines the standard interface dimensions for type MU family of
connectors.
2 Description
The parent connector for type MU connector family is a miniature single-position plug which is
characterized by a cylindrical, spring-loaded butting ferrule(s) of a 1,25 mm typical diameter,
and a push-pull coupling mechanism. The optical alignment mechanism of the connectors is
of a rigid hole or a resilient sleeve style.
This part 6 type MU connector family defines the standard interface dimensions of active
device receptacles for the type MU connectors. The receptacles are used to retain the
connector plugs and mechanically maintain the optical datum target of the plugs at a defined
position within the receptacle housings.
3 Interfaces
This standard contains the following standard interfaces.
Interface 6-1: Simplex plug connector interface – Push/pull
Interface 6-2: Duplex plug connector interface – Push/pull
Interface 6-3: Simplex adaptor connector interface – Push/pull
Interface 6-4: Duplex adaptor connector interface – Push/pull
Interface 6-5: 8-port adaptor connector interface – Push/pull
Interface 6-6: Plug connector interface – for printed board housings
Interface 6-7: Sleeve holder interface – for printed board housings
Interface 6-8: 2-port backplane housing interface – Self-retentive
Interface 6-9: 2-port printed board housing interface – Self-retentive
Interface 6-10: 8-port backplane housing interface – Self-retentive
Interface 6-11: 8-port printed board housing interface – Self-retentive
Interface 6-12: Simplex active device receptacle interface – for PC connector plug
Interface 6-13: Duplex active device receptacle interface – for PC connector plug
The plugs of interfaces 6-1, 6-2 and 6-6 have a ferrule(s) with a spherically polished ferrule
endface, and realize physical contact.
– 10 – 61754-6 CEI:1997+A1:2001
La famille de connecteurs de type MU comprend deux types de jeux de connecteurs: jeu de
connecteurs MU-A (voir annexe A) et jeu de connecteurs MU-B (voir annexe B). Le jeu de
connecteurs MU-A est une configuration fiche-raccord à mécanisme de couplage pousser-
tirer. Le jeu de connecteurs MU-B est une configuration de connecteurs de fond de panier
enfichables, fiche/fond de panier et boîtiers de carte imprimée/fiche pour configuration boîtier
de carte imprimée/support de manchon et il est équipé d'un mécanisme d'auto-rétention.
Le jeu de connecteurs de type MU-A comporte des fiches simples et doubles, des raccords
simples, doubles et à 8 accès. Les fiches sont communes aux boîtiers de connecteurs de fond
de panier du jeu de connecteurs MU-B.
Le jeu de connecteurs de type MU-B comprend des boîtiers de connecteurs fond de panier et
carte imprimée à 2 accès et à 8 accès, des fiches simples et doubles, une fiche pour boîtiers
de connecteurs de cartes imprimées, et un support de manchon. La fiche pour boîtier de
connecteur de carte imprimée est utilisée comme un jack avec le support de manchon.
Le jack est connecté au boîtier de connecteur carte imprimée.
Les interfaces normalisées suivantes sont interconnectables.
Raccords
Fiches
Interface 6-3 Interface 6-4 Interface 6-5
Interface 6-1 Accouplement Accouplement Accouplement
Interface 6-2 Pas d'accouplement Accouplement Accouplement
Boîtiers de connecteurs
Fiches Boîtier de connecteur fond de panier Boîtier de connecteur carte imprimée
Interface 6-8 Interface 6-10 Interface 6-9 Interface 6-11
Interface 6-1 Accouplement Accouplement Pas d'accouplement Pas d'accouplement
Interface 6-2 Accouplement Accouplement Pas d'accouplement Pas d'accouplement
Interface 6-6
avec Pas d'accouplement Pas d'accouplement Accouplement Accouplement
Interface 6-7
Connecteurs à fiche
Embases Interface 6-1 Interface 6-2
(connecteur à fiche (connecteur à fiche
monovoie) double)
Interface 6-12 Accouplement Pas d’accouplement
(embase monovoie)
Interface 6-13 Accouplement Accouplement
(embase double)
61754-6 IEC:1997+A1:2001 – 11 –
The type MU connector family comprises two types of connector set: MU-A connector set (see
annex A) and MU-B connector set (see annex B). The MU-A connector set is a plug/adaptor
configuration with a push-pull coupling mechanism. The MU-B connector set is a plug-in type
back-plane connector configuration which is plug/backplane and printed board housings/plug
for printed board housing/sleeve holder configuration and is equipped with a self-retentive
mechanism.
The type MU-A connector set consists of simplex and duplex plugs, and simplex, duplex and 8-port
adaptors. The plugs are common to the backplane connector housings of the type MU-B connector
set.
The type MU-B connector set consists of 2-port and 8-port backplane and printed board
connector housings, simplex and duplex plugs, plug for printed board connector housings,
and sleeve holder. The plug for printed board connector housing is used as a jack together
with the sleeve holder. The jack is attached into the printed board connector housing.
The following standard interfaces are intermateable.
Adaptors
Plugs
Interface 6-3 Interface 6-4 Interface 6-5
Interface 6-1 Mate Mate Mate
Interface 6-2 Not mate Mate Mate
Connector housings
Plugs Backplane connector housing Printed board connector housing
Interface 6-8 Interface 6-10 Interface 6-9 Interface 6-11
Interface 6-1 Mate Mate Not mate Not mate
Interface 6-2 Mate Mate Not mate Not mate
Interface 6-6
with Not mate Not mate Mate Mate
Interface 6-7
Plug connectors
Receptacles
Interface 6-1 Interface 6-2
(simplex plug connector) (duplex plug connector)
Interface 6-12 Mate Not mate
(simplex receptacle)
Interface 6-13 Mate Mate
(duplex receptacle)
– 12 – 61754-6 CEI:1997+A1:2001
Boîtier de déverrouillage
IEC 1355/01
Figure 1 – Interface de connecteurs à fiches simples
61754-6 IEC:1997+A1:2001 – 13 –
Delatch housing
IEC 1355/01
Figure 1 – Simplex plug connector interface
– 14 – 61754-6 CEI:1997+A1:2001
Tableau 1 – Dimensions de l'interface de connecteurs à fiches simples
Dimensions
Référence Notes
Minimum Maximum
A 1,2485 mm 1,2495 mm 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1 mm 1,1 mm 2 et 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AA 4,3 mm 4,4 mm
AB 3,85 mm 3,95 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Rayon
AE 3 mm –
AF 2,2 mm 2,3 mm
EA 40° 45°
EB 10 mm 25 mm Rayon, 5
EC 0,45 mm 0,73 mm
NOTE 1 Un chanfrein ou rayon est autorisé jusqu'à une profondeur maximale de 0,5 mm par
rapport à la partie antérieure de l'embout.
NOTE 2 Le boîtier de déverrouillage doit pouvoir être déplacé vers la droite et vers la gauche.
Ces dimensions sont indiquées lorsque le manchon de couplage est déplacé dans la position
située le plus à droite.
NOTE 3 La dimension J est indiquée pour la partie antérieure de la fiche quand elle n'est pas
accouplée. On remarque que l'embout peut être déplacé par une certaine force de compression
axiale avec des extrémités en contact direct; la dimension J est par conséquent variable.
La force de compression de l'embout doit être comprise entre 5,5 N et 6,5 N lorsque la position
de la cible de référence optique à partir de la référence X est déplacée de 3,9 mm à 4,1 mm.
De plus, la dimension J doit se réduire en dessous de 3,25 mm avec une force de compression
axiale relativement importante.
NOTE 4 La position du côté droit de Q doit devenir la position du côté gauche par rapport au
plan défini par la référence X lorsque le manchon de couplage est déplacé vers sa position
située le plus à gauche.
NOTE 5 L'excentricité du dôme de la partie antérieure de l'embout sphérique poli doit être
inférieure à 50 µm.
61754-6 IEC:1997+A1:2001 – 15 –
Table 1 – Dimensions of the simplex plug connector interface
Dimensions
Reference Notes
Minimum Maximum
A 1,2485 mm 1,2495 mm 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1 mm 1,1 mm 2 and 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AA 4,3 mm 4,4 mm
AB 3,85 mm 3,95 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Radius
AE 3 mm –
AF 2,2 mm 2,3 mm
EA 40° 45°
EB 10 mm 25 mm Radius, 5
EC 0,45 mm 0,73 mm
NOTE 1 A chamfer or radius is allowed to a maximum depth of 0,5 mm from the ferrule
endface.
NOTE 2 The delatch housing shall be movable toward the right and the left directions. These
dimensions are given when the coupling sleeve is moved in its most right-direction position.
NOTE 3 The dimension J is given for the plug endface when not mated. It is noticed that the
ferrule is movable by a certain axial compression force with direct contacting endfaces, and
therefore the dimension J is variable. Ferrule compression force shall be 5,5 N to 6,5 N when
the position of the optical datum target from the datum X is moved in the range of 3,9 mm to
4,1 mm. In addition, the dimension J shall become less than 3,25 mm with a relatively large
axial compression force.
NOTE 4 The right-side position of Q shall become the left-side position to the plane defined by
datum X when the coupling sleeve is moved to its most left-direction position.
NOTE 5 Dome eccentricity of the spherically polished ferrule endface shall be less than 50 μm.
– 16 – 61754-6 CEI:1997+A1:2001
Boîtier de déverrouillage
IEC 1356/01
Figure 2 – Interface de connecteurs à fiches doubles
61754-6 IEC:1997+A1:2001 – 17 –
Delatch housing
IEC 1356/01
Figure 2 – Duplex plug connector interface
– 18 – 61754-6 CEI:1997+A1:2001
Tableau 2 – Dimensions de l'interface de connecteurs à fiches doubles
Dimensions
Référence Notes
Minimum Maximum
A 1,2485 mm 1,2495 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1,0 mm 1,1 mm 2 et 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AB 3,7 mm 3,85 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Rayon
AE 3,0 mm –
AF 2,2 mm 2,3 mm
AJ 8,8 mm 8,9 mm
AK 8,35 mm 8,45 mm
AL 4,55 mm 4,7 mm
AM 4,45 mm 4,55 mm
AP – 3,7 mm
EA 40° 45°
EB 10 mm 25 mm Rayon, 5
EC 0,45 mm 0,73 mm
NOTE 1 Un chanfrein ou rayon est autorisé jusqu'à une profondeur maximale de 0,5 mm par
rapport à la partie antérieure de l'embout.
NOTE 2 Le boîtier de déverrouillage doit pouvoir être déplacé vers la droite et vers la gauche.
Ces dimensions sont indiquées lorsque le manchon de couplage est déplacé dans la position
située le plus à droite.
NOTE 3 La dimension J est indiquée pour la partie antérieure de la fiche quand elle n'est pas
accouplée. On remarque que l'embout peut être déplacé par une certaine force de compression
axiale avec des extrémités en contact direct; la dimension J est par conséquent variable.
La force de compression de l'embout doit être comprise entre 5,5 N et 6,5 N lorsque la position
de la cible de référence optique à partir de la référence X est déplacée de 3,9 mm à 4,1 mm.
De plus, la dimension J doit se réduire en dessous de 3,25 mm avec une force de compression
axiale relativement importante.
NOTE 4 La position du côté droit de Q doit devenir la position du côté gauche par rapport au
plan défini par la référence X lorsque le manchon de couplage est déplacé vers sa position
située la plus à gauche.
NOTE 5 L'excentricité du dôme de la partie antérieure de l'embout sphérique poli doit être
inférieure à 50 µm.
61754-6 IEC:1997+A1:2001 – 19 –
Table 2 – Dimensions of the duplex plug connector interface
Dimensions
Reference Notes
Minimum Maximum
A 1,2485 mm 1,2495 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1,0 mm 1,1 mm 2 and 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AB 3,7 mm 3,85 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Radius
AE 3,0 mm –
AF 2,2 mm 2,3 mm
AJ 8,8 mm 8,9 mm
AK 8,35 mm 8,45 mm
AL 4,55 mm 4,7 mm
AM 4,45 mm 4,55 mm
AP – 3,7 mm
EA 40° 45°
EB 10 mm 25 mm Radius, 5
EC 0,45 mm 0,73 mm
NOTE 1 A chamfer or radius is allowed to a maximum depth of 0,5 mm from the ferrule
endface.
NOTE 2 The delatch housing shall be movable toward the right and the left directions. These
dimensions are given when the coupling sleeve is moved in its most right-direction position.
NOTE 3 The dimension J is given for the plug endface when not mated. It is noticed that the
ferrule is movable by a certain axial compression force with direct contacting endfaces, and
therefore the dimension J is variable. Ferrule compression force shall be 5,5 N to 6,5 N when
the position of the optical datum target from the datum X is moved in the range of 3,9 mm to
4,1 mm. In addition, the dimension J shall become less than 3,25 mm with a relatively large
axial compression force.
NOTE 4 The right-side position of Q shall become left-side position to the plane defined by
datum X when the coupling sleeve is moved to its most left-direction position.
NOTE 5 Dome eccentricity of the spherically polished ferrule endface shall be less than 50 μm.
– 20 – 61754-6 CEI:1997+A1:2001
IEC 407/97
Figure 3a – Interface de connecteurs à raccords simples
61754-6 IEC:1997+A1:2001 – 21 –
IEC 407/97
Figure 3a – Simplex adaptor connector interface
– 22 – 61754-6 CEI:1997+A1:2001
Tableau 3a – Dimensions de l'interface de connecteurs à raccords simples
Dimensions
mm
Référence Notes
Minimum Maximum
A Voir tableau 3b
B 2,39 2,59
D4,8 5
E4,55 –
F 2,9 3,5 Voir note
I– 6,5
J3,9 4,1
K– 5,4
L 2,55 2,7
M– 1,4
N – 0,55
O– 0,6
P– 1,2
Q– 0,4
R – 2,55
S 5,65 5,75
U3,8 4
V3,3 –
W6,7 –
AA 4,45 4,55
AB 4,01 4,11
AC 0,95 1,15
AD – 0,2 Rayon
AE 2,8 2,95
AF 1,9 2,1
AG 0,3 – Rayon
AH 0,4 0,55
AI 1,34 1,44
NOTE La dimension F doit dépasser 4,5 mm lorsqu'une fiche est couplée au raccord ou retirée
du raccord.
Tableau 3b – Degré
Dimensions
mm
Grade Notes
Minimum Maximum
Manchon élastique,
1 et 2
NOTE 1 L'élément d'alignement des connecteurs est un manchon d'alignement élastique.
Il faut que cet élément admette une pointe de calibrage au centre du raccord accompagnée
d'une force de 1 N à 2,5 N à condition qu'une autre pointe de calibrage soit insérée dans
l'élément de l'autre côté. Le centre du raccord est défini par la position du côté droit de la
dimension J.
NOTE 2 Ajouter le numéro du degré au numéro de référence de l'interface.
61754-6 IEC:1997+A1:2001 – 23 –
Table 3a – Dimensions of the simplex adaptor connector interface
Dimensions
mm
Reference Notes
Minimum Maximum
A See table 3b
B 2,39 2,59
D4,8 5
E4,55 –
F 2,9 3,5 See note
I– 6,5
J3,9 4,1
K– 5,4
L 2,55 2,7
M– 1,4
N – 0,55
O– 0,6
P– 1,2
Q– 0,4
R – 2,55
S 5,65 5,75
U3,8 4
V3,3 –
W6,7 –
AA 4,45 4,55
AB 4,01 4,11
AC 0,95 1,15
AD – 0
...
NORME CEI
INTERNATIONALE
IEC
61754-6
INTERNATIONAL
Edition 1.2
STANDARD
2005-12
Edition 1:1997 consolidée par les amendements 1:2001 et 2:2004
Edition 1:1997 consolidated with amendments 1:2001 and 2:2004
Interfaces de connecteurs pour fibres optiques –
Partie 6:
Famille de connecteurs de type MU
Fibre optic connector interfaces –
Part 6:
Type MU connector family
Numéro de référence
Reference number
CEI/IEC 61754-6:1997+A1:2001+A2:2004
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
61754-6
INTERNATIONAL
Edition 1.2
STANDARD
2005-12
Edition 1:1997 consolidée par les amendements 1:2001 et 2:2004
Edition 1:1997 consolidated with amendments 1:2001 and 2:2004
Interfaces de connecteurs pour fibres optiques –
Partie 6:
Famille de connecteurs de type MU
Fibre optic connector interfaces –
Part 6:
Type MU connector family
IEC 2005 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
CQ
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61754-6 CEI:1997+A1:2001+A2:2004
SOMMAIRE
AVANT-PROPOS.6
1 Domaine d'application.10
2 Description.10
3 Interfaces.10
4 Interfaces de connecteurs PC angulaires de type MU .84
Annexe A (informative) Configuration d'un jeu de connecteurs de type MU-A .110
Annexe B (informative) Configuration d'un jeu de connecteurs de type MU-B .112
Figure 1 – Interface de connecteurs à fiches simples.14
Figure 2 – Interface de connecteurs à fiches doubles .18
Figure 3a – Interface de connecteurs à raccords simples.22
Figure 3b – Pointe de calibrage pour manchon d'alignement élastique.26
Figure 4a – Interface de connecteurs à raccords doubles .28
Figure 5a – Interface de connecteurs à raccords à 8 accès.28
Figure 4b – Pointe de calibrage pour manchon d'alignement élastique.32
Figure 5b – Pointe de calibrage pour manchon d'alignement élastique.32
Figure 5c – Interface de connecteurs à raccords à 8 accès.32
Figure 6 – Interface de connecteurs à fiches.34
Figure 7a – Interface de support de manchon .38
Figure 7b – Pointe de calibrage pour manchon d'alignement élastique.40
Figure 8 – Interface de boîtier de fond de panier à 2 accès.42
Figure 9 – Interface de boîtier de carte imprimée à 2 accès .48
Figure 10 – Interface de boîtier de fond de panier à 8 accès.54
Figure 11 – Interface de boîtier de carte imprimée à 8 accès .62
Figure 12a – Interface d’embase monovoie de dispositif actif.66
Figure 12b – Détail de l’arrêt mécanique pour un élément d’alignement à trou rigide .72
Figure 12c – Calibre pour manchon d’alignement élastique.74
Figure 13a – Interface d’embase double de dispositif actif .76
Figure 13b – Détail de l’arrêt mécanique pour un élément d’alignement à trou rigide .80
Figure 13c – Calibre pour manchon d’alignement élastique.82
Figure 14a – Interface de connecteur à fiche simple .86
Figure 14b – Interface de connecteur à fiche simple .88
Figure 15a – Interface de connecteurs à fiches doubles de 4,5 mm .94
Figure 15b – Interface de connecteurs à fiches doubles de 4,5 mm .96
Figure 16a – Interface de connecteurs à fiches doubles de 6,25 mm .102
Figure 16b – Interface de connecteurs à fiches doubles de 6,25 mm .104
61754-6 IEC:1997+A1:2001+A2:2004 – 3 –
CONTENTS
FOREWORD.7
1 Scope.11
2 Description .11
3 Interfaces .11
4 MU angled PC connector interfaces.85
Annex A (informative) Configuration of type MU-A connector set .111
Annex B (informative) Configuration of type MU-B connector set .113
Figure 1 – Simplex plug connector interface .15
Figure 2 – Duplex plug connector interface .19
Figure 3a – Simplex adaptor connector interface .23
Figure 3b – Gauge pin for resilient alignment sleeve.27
Figure 4a – Duplex adaptor connector interface .29
Figure 5a – 8-port adaptor connector interface.29
Figure 4b – Gauge pin for resilient alignment sleeve.33
Figure 5b – Gauge pin for resilient alignment sleeve.33
Figure 5c – 8-port adaptor connector interface.33
Figure 6 – Plug connector interface .35
Figure 7a – Sleeve holder interface .39
Figure 7b – Gauge pin for resilient alignment sleeve.41
Figure 8 – 2-port backplane housing interface.43
Figure 9 – 2-port printed board housing interface.49
Figure 10 – 8-port backplane housing interface.55
Figure 11 – 8-port printed board housing interface.63
Figure 12a – Simplex active device receptacle interface .67
Figure 12b – Detail of the mechanical stop for rigid bore alignment feature.73
Figure 12c – Pin gauge for the resilient alignment sleeve .75
Figure 13a – Duplex active device receptacle interface.77
Figure 13b – Detail of the mechanical stop for rigid bore alignment feature.81
Figure 13c – Pin gauge for the resilient alignment sleeve .83
Figure 14a – Simplex plug connector interface.87
Figure 14b – Simplex plug connector interface.89
Figure 15a – 4,5 mm duplex plug connector interface .95
Figure 15b – 4,5 mm duplex plug connector interface .97
Figure 16a – 6,25 mm duplex plug connector interface .103
Figure 16b – 6,25 mm duplex plug connector interface .105
– 4 – 61754-6 CEI:1997+A1:2001+A2:2004
Tableau 1 – Dimensions de l'interface de connecteurs à fiches simples .16
Tableau 2 – Dimensions de l'interface de connecteurs à fiches doubles.20
Tableau 3a – Dimensions de l'interface de connecteurs à raccords simples.24
Tableau 3b – Degré .24
Tableau 3c – Dimensions de la pointe de calibrage.26
Tableau 4a – Dimensions de l'interface de connecteurs à raccords doubles .30
Tableau 5a – Dimensions de l'interface de connecteurs à raccords à 8 accès.30
Tableau 4b – Degré .30
Tableau 5b – Degré .30
Tableau 4c – Dimensions de la pointe de calibrage.32
Tableau 5c – Dimensions de la pointe de calibrage.32
Tableau 5d – Dimensions de l'interface de connecteurs à raccords à 8 accès.32
Tableau 6 – Dimensions de l'interface de connecteurs à fiches.36
Tableau 7a – Dimensions de l'interface de support de manchon .38
Tableau 7b – Degré .40
Tableau 7c – Dimensions de la pointe de calibrage.40
Tableau 8a – Dimensions de l'interface de boîtier de fond de panier à 2 accès .46
Tableau 8b – Degré .48
Tableau 9 – Dimensions de l'interface de boîtier de carte imprimée à 2 accès .52
Tableau 10a – Dimensions de l'interface de boîtier de fond de panier à 8 accès .58
Tableau 10b – Degré .60
Tableau 11 – Dimensions de l'interface de boîtier de carte imprimée à 8 accès .68
Tableau 12a – Dimensions de l’interface d’embase monovoie de dispositif actif.70
Tableau 12b – Variantes de l’élément d’alignement .72
Tableau 12c – Dimensions de l’arrêt mécanique pour un élément d’alignement
à trou rigide .72
Tableau 12d – Variantes de l’élément d’arrêt mécanique .74
Tableau 12e – Dimensions du calibre .74
Tableau 13a – Dimensions de l’interface d’embase double de dispositif actif .78
Tableau 13b – Variantes de l’élément d’alignement .80
Tableau 13c – Dimensions de l’arrêt mécanique pour un élément d’alignement
à trou rigide .80
Tableau 13d – Variantes de l’élément d’arrêt mécanique .82
Tableau 13e – Dimensions du calibre .82
Tableau 14 – Dimensions de l'interface du connecteur à fiche simple .90
Tableau 15 – Dimensions des interfaces du connecteur à fiche double de 4,5 mm.98
Tableau 16 – Dimensions des interfaces de connecteur à fiche double de 6,25 mm.106
61754-6 IEC:1997+A1:2001+A2:2004 – 5 –
Table 1 – Dimensions of the simplex plug connector interface .17
Table 2 – Dimensions of the duplex plug connector interface.21
Table 3a – Dimensions of the simplex adaptor connector interface .25
Table 3b – Grade.25
Table 3c – Gauge pin dimensions .27
Table 4a – Dimensions of the duplex adaptor connector interface.31
Table 5a – Dimensions of the 8-port adaptor connector interface.31
Table 4b – Grade.31
Table 5b – Grade.31
Table 4c – Gauge pin dimensions .33
Table 5c – Gauge pin dimensions .33
Table 5d – Dimensions of the 8-port adaptor connector interface.33
Table 6 – Dimensions of the plug connector interface .37
Table 7a – Dimensions of the sleeve holder interface .39
Table 7b – Grade.41
Table 7c – Gauge pin dimensions .41
Table 8a – Dimensions of the 2-port backplane housing interface .47
Table 8b – Grade.49
Table 9 – Dimensions of the 2-port printed board housing interface .53
Table 10a – Dimensions of the 8-port backplane housing interface .59
Table 10b – Grade.61
Table 11 – Dimensions of the 8-port printed board housing interface .69
Table 12a – Dimensions of the simplex active device receptacle interface .71
Table 12b – Alignment feature grade .73
Table 12c – Dimensions of the mechanical stop for rigid bore alignment feature.73
Table 12d – Mechanical stop feature grade.75
Table 12e – Pin gauge dimensions .75
Table 13a – Dimensions of the duplex active device receptacle interface.79
Table 13b – Alignment feature grade .81
Table 13c – Dimensions of the mechanical stop for rigid bore alignment feature.81
Table 13d – Mechanical stop feature grade.83
Table 13e – Pin gauge dimensions .83
Table 14 – Dimensions of the simplex plug connector interfaces.91
Table 15 – Dimensions of the 4,5 mm duplex plug connector interfaces.99
Table 16 – Dimensions of the 6,25 mm duplex plug connector interfaces.107
– 6 – 61754-6 © CEI:1997+A1:2001+A2:2004
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 6: Famille de connecteurs de type MU
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 61754-6 a été établie par le sous-comité 86B: Dispositifs
d'interconnexion et composants passifs à fibres optiques, du comité d'études 86 de la CEI:
Fibres optiques.
La présente version consolidée de la CEI 61754-6 comprend la première édition (1997)
[documents 86B/881/FDIS et 86B/983/RVD], son amendement 1 (2001) [documents
86B/1402/FDIS et 86B/1455/RVD], son amendement 2 (2004) [documents 86B/2014/FDIS et
86B/2030/RVD] et son corrigendum d'août 1997.
Le contenu technique de cette version consolidée est donc identique à celui de l'édition de
base et à ses amendements; cette version a été préparée par commodité pour l'utilisateur.
Elle porte le numéro d'édition 1.2.
Une ligne verticale dans la marge indique où la publication de base a été modifiée par les
amendements 1 et 2 et le corrigendum.
Les annexes A et B sont données uniquement à titre d'information.
61754-6 © IEC:1997+A1:2001+A2:2004 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC CONNECTOR INTERFACES –
Part 6: Type MU connector family
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61754-6 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
This consolidated version of IEC 61754-6 consists of the first edition (1997) [documents
86B/881/FDIS and 86B/983/RVD], its amendment 1 (2001) [documents 86B/1402/FDIS and
86B/1455/RVD], its amendment 2 (2004) [documents 86B/2014/FDIS and 86B/2030/RVD] and
the corrigendum of August 1997.
The technical content is therefore identical to the base edition and its amendments and has
been prepared for user convenience.
It bears the edition number 1.2.
A vertical line in the margin shows where the base publication has been modified by
amendments 1 and 2 and the corrigendum.
Annexes A and B are for information only.
– 8 – 61754-6 CEI:1997+A1:2001+A2:2004
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant la date de maintenance indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée
61754-6 IEC:1997+A1:2001+A2:2004 – 9 –
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 10 – 61754-6 CEI:1997+A1:2001+A2:2004
INTERFACES DE CONNECTEURS POUR FIBRES OPTIQUES –
Partie 6: Famille de connecteurs de type MU
1 Domaine d'application
La présente partie de la CEI 61754 définit les dimensions d'interfaces normalisées de la
famille de connecteurs de type MU.
2 Description
Le connecteur principal de la famille de connecteurs de type MU est une fiche miniature à
position unique caractérisée par un ou plusieurs embouts en butée à ressort cylindrique de
diamètre type égal à 1,25 mm et un mécanisme de couplage pousser/tirer. Le mécanisme
d'alignement optique des connecteurs est d'un type à trou rigide ou à manchon élastique.
La présente partie 6, relative à la famille des connecteurs de type MU, définit les dimensions
des interfaces normalisées des embases de dispositifs actifs pour les connecteurs de type MU.
Les embases sont utilisées pour retenir les connecteurs à fiche et pour maintenir
mécaniquement la cible de référence optique des fiches dans une position définie à l’intérieur
des boîtiers d’embases.
3 Interfaces
La présente norme contient les interfaces normalisées suivantes.
Interface 6-1: Interface de connecteurs à fiches simples – Pousser/tirer
Interface 6-2: Interface de connecteurs à fiches doubles – Pousser/tirer
Interface 6-3: Interface de connecteurs à raccords simples – Pousser/tirer
Interface 6-4: Interface de connecteurs à raccords doubles – Pousser/tirer
Interface 6-5: Interface de connecteurs à raccords à 8 accès – Pousser/tirer
Interface 6-6: Interface de connecteurs à fiches – pour boîtiers de carte imprimée
Interface 6-7: Interface de support de manchon – pour boîtiers de carte imprimée
Interface 6-8: Interface de boîtier de fond de panier à 2 accès – Auto-rétention
Interface 6-9: Interface de boîtier de carte imprimée à 2 accès – Auto-rétention
Interface 6-10: Interface de boîtier de fond de panier à 8 accès – Auto-rétention
Interface 6-11: Interface de boîtier de carte imprimée à 8 accès – Auto-rétention
Interface 6-12: Interface d’embase monovoie de dispositif actif – pour connecteur à fiche
à contact PC
Interface 6-13: Interface d’embase double de dispositif actif – pour connecteur à fiche
à contact PC
Interface 6-16: Interface de connecteurs à fiches simples – pousser/tirer, APC 8 degrés
Interface 6-17: Interface de connecteurs à fiches doubles de 4,5 mm – pousser/tirer,
APC 8 degrés
Interface 6-18: Interface de connecteurs à fiches doubles de 6,25 mm – pousser/tirer,
APC 8 degrés
Les fiches des interfaces 6-1, 6-2 et 6-6 possèdent un ou plusieurs embouts à extrémité
sphérique polie, et établissent le contact physique.
61754-6 IEC:1997+A1:2001+A2:2004 – 11 –
FIBRE OPTIC CONNECTOR INTERFACES –
Part 6: Type MU connector family
1 Scope
This part of IEC 61754 defines the standard interface dimensions for type MU family of
connectors.
2 Description
The parent connector for type MU connector family is a miniature single-position plug which is
characterized by a cylindrical, spring-loaded butting ferrule(s) of a 1,25 mm typical diameter,
and a push-pull coupling mechanism. The optical alignment mechanism of the connectors is
of a rigid hole or a resilient sleeve style.
This part 6 type MU connector family defines the standard interface dimensions of active
device receptacles for the type MU connectors. The receptacles are used to retain the
connector plugs and mechanically maintain the optical datum target of the plugs at a defined
position within the receptacle housings.
3 Interfaces
This standard contains the following standard interfaces.
Interface 6-1: Simplex plug connector interface – Push/pull
Interface 6-2: Duplex plug connector interface – Push/pull
Interface 6-3: Simplex adaptor connector interface – Push/pull
Interface 6-4: Duplex adaptor connector interface – Push/pull
Interface 6-5: 8-port adaptor connector interface – Push/pull
Interface 6-6: Plug connector interface – for printed board housings
Interface 6-7: Sleeve holder interface – for printed board housings
Interface 6-8: 2-port backplane housing interface – Self-retentive
Interface 6-9: 2-port printed board housing interface – Self-retentive
Interface 6-10: 8-port backplane housing interface – Self-retentive
Interface 6-11: 8-port printed board housing interface – Self-retentive
Interface 6-12: Simplex active device receptacle interface – for PC connector plug
Interface 6-13: Duplex active device receptacle interface – for PC connector plug
Interface 6-16: Simplex plug connector interface – push/pull, APC 8 degrees
Interface 6-17: 4,5 mm duplex plug connector interface – push/pull, APC 8 degrees
Interface 6-18: 6,25 mm duplex plug connector interface – push/pull, APC 8 degrees
The plugs of interfaces 6-1, 6-2 and 6-6 have a ferrule(s) with a spherically polished ferrule
endface, and realize physical contact.
– 12 – 61754-6 CEI:1997+A1:2001+A2:2004
La famille de connecteurs de type MU comprend deux types de jeux de connecteurs: jeu de
connecteurs MU-A (voir annexe A) et jeu de connecteurs MU-B (voir annexe B). Le jeu de
connecteurs MU-A est une configuration fiche-raccord à mécanisme de couplage pousser-
tirer. Le jeu de connecteurs MU-B est une configuration de connecteurs de fond de panier
enfichables, fiche/fond de panier et boîtiers de carte imprimée/fiche pour configuration boîtier
de carte imprimée/support de manchon et il est équipé d'un mécanisme d'auto-rétention.
Le jeu de connecteurs de type MU-A comporte des fiches simples et doubles, des raccords
simples, doubles et à 8 accès. Les fiches sont communes aux boîtiers de connecteurs de fond
de panier du jeu de connecteurs MU-B.
Le jeu de connecteurs de type MU-B comprend des boîtiers de connecteurs fond de panier et
carte imprimée à 2 accès et à 8 accès, des fiches simples et doubles, une fiche pour boîtiers
de connecteurs de cartes imprimées, et un support de manchon. La fiche pour boîtier de
connecteur de carte imprimée est utilisée comme un jack avec le support de manchon.
Le jack est connecté au boîtier de connecteur carte imprimée.
Les interfaces normalisées suivantes sont interconnectables.
Raccords
Fiches
Interface 6-3 Interface 6-4 Interface 6-5
Interface 6-1 Accouplement Accouplement Accouplement
Interface 6-2 Pas d'accouplement Accouplement Accouplement
Boîtiers de connecteurs
Fiches Boîtier de connecteur fond de panier Boîtier de connecteur carte imprimée
Interface 6-8 Interface 6-10 Interface 6-9 Interface 6-11
Interface 6-1 Accouplement Accouplement Pas d'accouplement Pas d'accouplement
Interface 6-2 Accouplement Accouplement Pas d'accouplement Pas d'accouplement
Interface 6-6
avec Pas d'accouplement Pas d'accouplement Accouplement Accouplement
Interface 6-7
Connecteurs à fiche
Embases
Interface 6-1 Interface 6-2
(connecteur à fiche (connecteur à fiche
monovoie) double)
Interface 6-12 Accouplement Pas d’accouplement
(embase monovoie)
Interface 6-13 Accouplement Accouplement
(embase double)
61754-6 IEC:1997+A1:2001+A2:2004 – 13 –
The type MU connector family comprises two types of connector set: MU-A connector set (see
annex A) and MU-B connector set (see annex B). The MU-A connector set is a plug/adaptor
configuration with a push-pull coupling mechanism. The MU-B connector set is a plug-in type
back-plane connector configuration which is plug/backplane and printed board housings/plug
for printed board housing/sleeve holder configuration and is equipped with a self-retentive
mechanism.
The type MU-A connector set consists of simplex and duplex plugs, and simplex, duplex and 8-port
adaptors. The plugs are common to the backplane connector housings of the type MU-B connector
set.
The type MU-B connector set consists of 2-port and 8-port backplane and printed board
connector housings, simplex and duplex plugs, plug for printed board connector housings,
and sleeve holder. The plug for printed board connector housing is used as a jack together
with the sleeve holder. The jack is attached into the printed board connector housing.
The following standard interfaces are intermateable.
Adaptors
Plugs
Interface 6-3 Interface 6-4 Interface 6-5
Interface 6-1 Mate Mate Mate
Interface 6-2 Not mate Mate Mate
Connector housings
Plugs
Backplane connector housing Printed board connector housing
Interface 6-8 Interface 6-10 Interface 6-9 Interface 6-11
Interface 6-1 Mate Mate Not mate Not mate
Interface 6-2 Mate Mate Not mate Not mate
Interface 6-6
with Not mate Not mate Mate Mate
Interface 6-7
Plug connectors
Receptacles
Interface 6-1 Interface 6-2
(simplex plug connector) (duplex plug connector)
Interface 6-12 Mate Not mate
(simplex receptacle)
Interface 6-13 Mate Mate
(duplex receptacle)
– 14 – 61754-6 CEI:1997+A1:2001+A2:2004
Boîtier de déverrouillage
IEC 1355/01
Figure 1 – Interface de connecteurs à fiches simples
61754-6 IEC:1997+A1:2001+A2:2004 – 15 –
Delatch housing
IEC 1355/01
Figure 1 – Simplex plug connector interface
– 16 – 61754-6 CEI:1997+A1:2001+A2:2004
Tableau 1 – Dimensions de l'interface de connecteurs à fiches simples
Dimensions
Référence Notes
Minimum Maximum
A 1,2485 mm 1,2495 mm 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1 mm 1,1 mm 2 et 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AA 4,3 mm 4,4 mm
AB 3,85 mm 3,95 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Rayon
AE 3 mm –
AF 2,2 mm 2,3 mm
EA 40° 45°
EB 10 mm 25 mm Rayon, 5
EC 0,45 mm 0,73 mm
NOTE 1 Un chanfrein ou rayon est autorisé jusqu'à une profondeur maximale de 0,5 mm par
rapport à la partie antérieure de l'embout.
NOTE 2 Le boîtier de déverrouillage doit pouvoir être déplacé vers la droite et vers la gauche.
Ces dimensions sont indiquées lorsque le manchon de couplage est déplacé dans la position
située le plus à droite.
NOTE 3 La dimension J est indiquée pour la partie antérieure de la fiche quand elle n'est pas
accouplée. On remarque que l'embout peut être déplacé par une certaine force de compression
axiale avec des extrémités en contact direct; la dimension J est par conséquent variable.
La force de compression de l'embout doit être comprise entre 5,5 N et 6,5 N lorsque la position
de la cible de référence optique à partir de la référence X est déplacée de 3,9 mm à 4,1 mm.
De plus, la dimension J doit se réduire en dessous de 3,25 mm avec une force de compression
axiale relativement importante.
NOTE 4 La position du côté droit de Q doit devenir la position du côté gauche par rapport au
plan défini par la référence X lorsque le manchon de couplage est déplacé vers sa position
située le plus à gauche.
NOTE 5 L'excentricité du dôme de la partie antérieure de l'embout sphérique poli doit être
inférieure à 50 µm.
61754-6 IEC:1997+A1:2001+A2:2004 – 17 –
Table 1 – Dimensions of the simplex plug connector interface
Dimensions
Reference Notes
Minimum Maximum
A 1,2485 mm 1,2495 mm 1
B 2,6 mm 2,7 mm
C 4,6 mm 4,8 mm
D 4,65 mm 4,75 mm
E 4,3 mm 4,4 mm
F 3,3 mm 3,4 mm
G 25° 35°
H 25° 35°
I 6,55 mm – 2
J 4,2 mm 4,5 mm 3
K 5,5 mm –
L 2,4 mm 2,5 mm
M 1,5 mm –
N 0,6 mm –
O 0,5 mm –
P 2,6 mm – 2
Q 1 mm 1,1 mm 2 and 4
R 2,65 mm 2,9 mm 2
S 5,5 mm 5,6 mm
T 4,3 mm 4,5 mm
U – 3,7 mm
V – 2,4 mm
W 6,5 mm 6,6 mm
AA 4,3 mm 4,4 mm
AB 3,85 mm 3,95 mm
AC 0,7 mm 0,9 mm
AD 0,2 mm – Radius
AE 3 mm –
AF 2,2 mm 2,3 mm
EA 40° 45°
EB 10 mm 25 mm Radius, 5
EC 0,45 mm 0,73 mm
NOTE 1 A chamfer or radius is allowed to a maximum depth of 0,5 mm from the ferrule
endface.
NOTE 2 The delatch housing shall be movable toward the right and the left directions. These