IEC PAS 61169-41:2009
(Main)Radio-frequency connectors - Part 41: Sectional specification for CQA series quick lock R.F. coaxial connectors
General Information
- Abstract
IEC/PAS 61169-41:2009(E) is a sectional specification. It provides information and rules for preparation of detail specification of CQA series quick lock R.F. coaxial connectors together with the pro- forma blank detail specification. It also prescribes mating face dimensions for general connectors-grade 2, dimensional detail of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to CQA series RF connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levers M and H.
- Status
- Replaced
- Publication Date
- 06-Apr-2009
- Technical Committee
- SC 46F - RF and microwave passive components
- Current Stage
- DELPUB - Deleted Publication
- Start Date
- 23-Feb-2011
- Completion Date
- 28-Aug-2026
Relations
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
IEC PAS 61169-41:2009 is a technical specification published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 41: Sectional specification for CQA series quick lock R.F. coaxial connectors". This standard covers: IEC/PAS 61169-41:2009(E) is a sectional specification. It provides information and rules for preparation of detail specification of CQA series quick lock R.F. coaxial connectors together with the pro- forma blank detail specification. It also prescribes mating face dimensions for general connectors-grade 2, dimensional detail of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to CQA series RF connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levers M and H.
IEC/PAS 61169-41:2009(E) is a sectional specification. It provides information and rules for preparation of detail specification of CQA series quick lock R.F. coaxial connectors together with the pro- forma blank detail specification. It also prescribes mating face dimensions for general connectors-grade 2, dimensional detail of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to CQA series RF connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levers M and H.
IEC PAS 61169-41:2009 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC PAS 61169-41:2009 has the following relationships with other standards: It is inter standard links to IEC 61169-41:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC PAS 61169-41:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC/PAS 61169-41 ®
Edition 1.0 2009-04
PUBLICLY AVAILABLE
SPECIFICATION
PRE-STANDARD
Radio-frequency connectors –
Part 41: Sectional specification for CQA series quick lock R.F. coaxial
connectors
IEC/PAS 61169-41:2009(E)
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC/PAS 61169-41 ®
Edition 1.0 2009-04
PUBLICLY AVAILABLE
SPECIFICATION
PRE-STANDARD
Radio-frequency connectors –
Part 41: Sectional specification for CQA series quick lock R.F. coaxial
connectors
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
V
ICS 33.120.30 ISBN 978-2-88910-801-5
– 2 – PAS 61169-41 © IEC:2009(E)
CONTENTS
FOREWORD.4
INTRODUCTION.5
1 Scope.6
2 Normative references .6
3 Mating face and gauge information.7
3.1 Dimensions-general connectors – Grade 2 .7
3.1.1 Connector with pin-centre contact.7
3.1.2 Connector with socket-centre contact .9
3.2 Gauges .11
3.2.1 Gauge pins for socket-centre contact.11
3.2.2 Test procedure .11
3.2.3 Gauge pins for outer contact of connector with pin-centre .12
3.2.4 Test procedure .13
3.3 Dimensions- standard test connectors – Grade 0 .14
3.3.1 Connector with pin-centre contact.14
3.3.2 Connector with socket-centre contact .16
4 Quality assessment procedure.17
4.1 General .17
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) .17
4.3 Test schedule and inspection requirements – Acceptance tests.21
4.3.1 Acceptance tests .21
4.3.2 Periodic tests .22
4.4 Procedures.25
4.4.1 Quality conformance inspection .25
4.4.2 Qualification approval and its maintenance.25
5 Instructions for preparation of detail specifications .25
5.1 General .25
5.2 Identification of the component.25
5.3 Performance.25
5.4 Marking, ordering information and related matters .26
5.5 Selection of tests, test conditions and severities.26
5.6 Blank detail specification pro-forma for type CQA connector.27
Annex A (normative) Adjunct for SMA intermateability .32
Figure 1 – Connector with pin-centre contact .7
Figure 2 – Connector with socket-centre contact.9
Figure 3 – Gauge pins for socket-centre contact .11
Figure 4 – Gauge pins for outer contact .12
Figure 5 – Connector with pin-centre contact .14
Figure 6 – Connector with socket-centre contact.16
Figure A.1 – Adjunct (for dimensions and notes see Table A.1) .32
PAS 61169-41 © IEC:2009(E) – 3 –
Table 1 – Dimensions of connector with pin-centre contact .8
Table 2 – Dimensions of connector with socket-centre contact.10
Table 3 – Dimensions of gauge pins for socket-centre contact .11
Table 4 – Gauge pins for outer contact .12
Table 5 – Dimensions of connector with pin-centre contact .15
Table 6 – Dimensions of connector with socket-centre contact.17
Table 7 – Rating and characteristics .18
Table 8 – Acceptance tests.21
Table 9 – Periodic tests .22
Table A.1 – Dimensions of adjunct.32
– 4 – PAS 61169-41 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 41: Sectional specification for CQA series
quick lock R.F. coaxial connectors
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
A PAS is a technical specification not fulfilling the requirements for a standard, but made
available to the public.
IEC-PAS 61169-41 has been processed by subcommittee 46F: RF and microwave passive
components, of IEC technical committee 46: Cables, wires, waveguides, R.F. connectors, R.F.
and microwave passive components and accessories.
The text of this PAS is based on the This PAS was approved for
following document: publication by the P-members of the
committee concerned as indicated in
the following document
Draft PAS Report on voting
46F/100/PAS 46F/112/RVD
Following publication of this PAS, which is a pre-standard publication, the technical committee
or subcommittee concerned may transform it into an International Standard.
This PAS shall remain valid for an initial maximum period of 3 years starting from the
publication date. The validity may be extended for a single 3-year period, following which it
shall be revised to become another type of normative document, or shall be withdrawn.
PAS 61169-41 © IEC:2009(E) – 5 –
INTRODUCTION
International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed
that compliance with this document may involve the use of a patent concerning IEC 61169-41.
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured IEC that he/she is willing to negotiate licences
under reasonable and non-discriminatory terms and conditions with applicants throughout the
world. In this respect, the statement of the holder of this patent right is registered with IEC.
Information may be obtained from:
Xi’an forstar S&T CO., LTD, No.17 C District No.69 Jinye Road Hi-tech Zone Xi’an R.P China
China Pat. No. ZL 200620136072.X / China Pat. No. ZL 200620136073.4 /
China Pat. No. ZL 200620136071.5 / China Pat. Application No. 200610104844.6 /
US Pat. Application No. 11/891,342
FORSTAR is the trade name of Xi’an forstar S&T CO., LTD.
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights other than those identified above. IEC shall not be held responsible for
identifying any or all such patent rights.
– 6 – PAS 61169-41 © IEC:2009(E)
RADIO-FREQUENCY CONNECTORS –
Part 41: Sectional specification for CQA series
quick lock R.F. coaxial connectors
1 Scope
CQA series quick lock connectors with characteristic impedance 50 Ω are used in microwave,
telecommunication, wireless and other fields, connecting with RF cables or micro-strips. The
operating frequency limit is up to 18 GHz.
This PAS, which is a sectional specification, provides information and rules for preparation of
detail specification of CQA series quick lock R.F. coaxial connectors together with the pro-
forma blank detail specification.
It also prescribes mating face dimensions for general connectors-grade 2, dimensional detail
of standard test connectors-grade 0, gauging information and tests selected from
IEC 61169-1 applicable to all detail specifications relating to CQA series RF connectors.
This specification indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levers M and H.
A CQA series connector with pin-centre contact can mate with a SMA series connector with
socket-centre contact; when mating with a SMA series connector, an adjunct is required. The
adjunct should meet the requirements of Annex A.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
)
requirements and measuring methods
Amendment 1(1996)
Amendment 2 (1997)
)
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1, its Amendment 1 and its
Amendment 2.
PAS 61169-41 © IEC:2009(E) – 7 –
3 Mating face and gauge information
3.1 Dimensions-general connectors – Grade 2
3.1.1 Connector with pin-centre contact
Metric dimension are original dimensions.
All undimensioned pictorial configurations are for reference purpose only.
Note 1
See detail A Note 5
g
e
Note 1
h
j
See detail B f
Note 6
t
w
Note 1
q
p
s
y
ab
Detail B
Detail A
NOTE For dimensions and notes, see Table 1.
Figure 1 – Connector with pin-centre contact
n
a
r
Note 2
m
k
d
c
b
– 8 – PAS 61169-41 © IEC:2009(E)
Table 1 – Dimensions of connector with pin-centre contact
mm
Ref. Notes
Min. Max.
a — 10,5
b 7,25 —
c 6,8 Nominal Note 4
d 4,53 4,59
e 0,25 0,75
f 3,15 — Note 3
g 0,00 0,18
h 0,00 0,25
j — 4,02
k 0,90 0,94
m — 0,38
n 56° 64° Angle
p — 2,54
q — 0,50
r 1,27 Nominal
s 0,47 0,60
t 45° Nominal Angle
w 20° Angle
y 0,60 —
ab 2,00 —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Diameters are chosen upon the assumption that the PTFE dielectric has a dielectric
constant of 2,02 to give an impedance of 50 Ω.
NOTE 3 Dimension f should be such that the reference planes coincide and the connectors
meet the required electrical and environmental performance.
NOTE 4 Should meet mechanical requirements.
NOTE 5 Design for slotting is optional, and should meet electrical and mechanical
performance requirements.
NOTE 6 Outer lock sleeve has a distance of 1,0 mm min. of movement from right to left.
h
g
PAS 61169-41 © IEC:2009(E) – 9 –
3.1.2 Connector with socket-centre contact
d
n
e
m
f
i
ab
See detail A
q p
Note 5
Note 1
j
Detail A
NOTE For dimensions and notes, see Table 2.
Figure 2 – Connector with socket-centre contact
c
b
a
Note 4
k
Note 2
– 10 – PAS 61169-41 © IEC:2009(E)
Table 2 – Dimensions of connector with socket-centre contact
mm
Ref. Notes
Min. Max.
a 4,60 —
b 6,70 6,90
c 7,15 7,24
d 7,50 -
e 0,32 0,45
f 0,55 —
g 60° Nominal Angle Note 3
h — 20° Angle
i 0 0,18
j 2,82 —
k 1,27 Nominal
p 0 0,25
m 0,25 0,50
n 1,70 2,00
q 3,00 3,15
ab 0,30 0,60 Radius
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Diameters are chosen upon the assumption that the PTFE dielectric has a dielectric
constant of 2,02 to give an impedance of 50 Ω.
NOTE 3 Should meet mechanical requirements.
NOTE 4 Design for slotting is optional, and should meet electrical and mechanical requirements,
when mating with Ø 0,90 mm to Ø 0,94 mm gauge pin.
NOTE 5 Design for root cut is allowed, no chamfer is allowed.
PAS 61169-41 © IEC:2009(E) – 11 –
3.2 Gauges
3.2.1 Gauge pins for socket-centre contact
50°
a
0.2mm max
R0.4mm max
NOTE For dimensions and notes, see Table 3.
Figure 3 – Gauge pins for socket-centre contact
Table 3 – Dimensions of gauge pins for socket-centre contact
Gauge B
Gauge A
Minimum material for measurement
of retention force
Maximum material for sizing purposes
Ref.
Mass of gauge: 29 g ± 1 g
mm mm
Min. Max. Min. Max.
a 0,940 0,945 0,895 0,900
b 1,27 1,91 1,27 1,91
Material: steel, polished, surface roughness: Ra=0,4 μm maximum
3.2.2 Test procedure
Gauge A shall be inserted into the socket-centre contact three times with a minimum depth of
1,27 mm. This is a sizing operation and should only be carried out when the socket-centre
contact is removed from the connector.
After this, gauge B shall be inserted into the socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position. The test should also be carried out on
connector when the socket-centre contact is not removed.
Additional test:
At the conclusion of the tests and if prescribed in the DS, the force necessary to insert gauge
A shall be measured. When the additional test is required, the force required shall not exceed
13,3 N.
50¡ ¡ã À2¡ ã
b
– 12 – PAS 61169-41 © IEC:2009(E)
3.2.3 Gauge pins for outer contact of connector with pin-centre
d
e f
m
p
n
g
h
q j
NOTE For dimensions and notes, see Table 4.
Figure 4 – Gauge pins for outer contact
Table 4 – Gauge pins for outer contact
Gauge B
Gauge A
Minimum material for measurement
of retention force
Maximum material for sizing purposes
Ref.
Mass of gauge: 625 g ± 25 g
mm mm
Min. Max. Min. Max.
a 4,60 — 4,60 —
b 6,70 6,75 6,85 6,90
c 7,24 7,245 7,145 7,15
d 7,50 — 7,50 —
e 3,48 3,485 3,295 3,30
f 0,55 0,70 0,55 0,70
g 63º 63,5º 56,5º 57º
h — 20º — 20º
j 3,50 — 3,50 —
k 1,40 — 1,40 —
m 3,05 3,15 3,05 3,15
n 1,55 1,6 1,40 1,45
p 0,45 0,55 0,45 0,55
q 3,16 — 3,15 —
Material: steel, polished, surface roughness: Ra = 0,4 µm maximum
c
b
a
k
PAS 61169-41 © IEC:2009(E) – 13 –
3.2.4 Test procedure
Gauge A shall be inserted into the outer contact three times. This is a sizing operation and
should only be carried out when the outer contact is removed from the connector.
After this, gauge B shall be inserted into the socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position. The test should be carried out on
connector when the outer contact is not removed.
Additional test:
At the conclusion of the tests and if prescribed in the DS, the force necessary to insert gauge
A shall be measured. When this additional test is required, the force required shall not exceed
25 N. This test should be carried out on connector when the outer contact is not removed.
– 14 – PAS 61169-41 © IEC:2009(E)
3.3 Dimensions- standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact
0.08mm B
Note 1
See detail A
0.08mm B
B
g
e
Note 5
h
See detail B
Note 6
Note 1
j
f
t
w
Note 1
q
s
p
y
B
ab
Detail A
Detail B
NOTE For dimensions and notes, see Table 5.
Figure 5 – Connector with pin-centre contact
n
Note 2
r
0.08mm B
m
0.08mm
B
k
d
c
b
a
PAS 61169-41 © IEC:2009(E) – 15 –
Table 5 – Dimensions of connector with pin-centre contact
mm Notes
Ref.
Min. Max.
a — 10,5
b 7,25 7,28
c 6,75 6,85 Note 4
d 4,53 4,59
e 0,25 0,75
f 3,15 — Note 3
g 0 0,05
h 0 0,076
j — 4,02
k 0,90 0,927
m — 0,38
n 50° Angle
p 2,03 2,29
q 0,45 0,50
r 1,27 nominal Note 2
s 0,50 0,57
t 45° nominal Angle
w 20° Angle
y 0,60 —
ab 2,00 —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Diameters are chosen upon the assumption that the PTFE dielectric has a dielectric
constant of 2,02 to give an impedance of 50 Ω ± 0,5 Ω.
NOTE 3 Dimension f should be such that the reference planes coincide and the connectors meet
the required electrical and environmental performance.
NOTE 4 Should meet electrical and mechanical performance requirements.
NOTE 5 Design for slotting is optional, and should meet electrical and mechanical performance
requirements.
NOTE 6 Design for spring is optional, and should meet the requirement of outer lock sleeve
having a axial movement distance of 1,0 mm min.
g h
– 16 – PAS 61169-41 © IEC:2009(E)
3.3.2 Connector with socket-centre contact
d
n
e
m
f
y
ab i
q p See detail C
Note 5
A
0.013 mm
Note 1
0.013 mm
A
0.08mm
A
j
B
Note 1
Detail C
NOTE For dimensions and notes, see Table 6.
Figure 6 – Connector with socket-centre contact
c
b
a
Note 4
k
Note 2
PAS 61169-41 © IEC:2009(E) – 17 –
Table 6 – Dimensions of connector with socket-centre contact
mm
Ref. Notes
Min. Max.
a 4,60 4,67
b 6,75 6,85
c 7,18 7,22
d 7,50 —
e 0,32 0,45
f 0,55 —
g 60° Angle Note 3
h — 20° Angle
i — 0,05
j 2,82 —
k 1,27 Nominal Note 2
m 0,25 0,50
n 1,70 2,00
p — 0,076
q 3,01 3,06
y — 0,25
ab 0,45 0,55 Radius
NOTE 1 Mechanical and electrical reference plane.