EN 61810-1:2008
(Main)Electromechanical elementary relays - Part 1: General requirements
Electromechanical elementary relays - Part 1: General requirements
Applies to electromechanical elementary relays (non-specified time all-or-nothing relays) for incorporation into equipment. Defines the basic functional requirements and safety-related aspects for applications in all areas of electrical engineering or electronics. Compliance with the requirements of this standard is verified by the type tests indicated. The main changes with respect to the previous edition comprise: - inclusion of contact load categories (same as in IEC 61810-2 and IEC 61810-7); - clarifications concerning electrical endurance; - inclusion of provisions for insulation coordination in accordance with the basic safety standards; - inclusion of new annexes for the test set-up, and for special loads.
Elektromechanische Elementarrelais - Teil 1: Allgemeine Anforderungen
Relais électromécaniques élémentaires - Partie 1: Exigences générales
La CEI 61810-1:2008 s'applique aux relais électromécaniques élémentaires (relais de tout ou rien à temps non spécifié) destinés à être incorporés dans des matériels. Elle définit les exigences fonctionnelles fondamentales et les aspects liés à la sécurité, destinés à être appliqués dans tous les domaines de l'électrotechnique ou de l'électronique. La conformité aux exigences de la présente norme est vérifiée par les essais de type indiqués. Cette troisième édition annule et remplace la deuxième édition parue en 2003, dont elle constitue une révision technique. Les modifications pertinentes sont les suivantes: - introduction de catégories de charges de contact (identiques à celles de la CEI 61810-2 et de la CEI 61810-7); - précisions concernant l'endurance électrique (Article 11); - introduction de dispositions pour la coordination de l'isolement, conformément aux normes de sécurité de base CEI 60664-3, CEI 60664-4 et CEI 60664-5 (Article 13); - introduction de nouvelles Annexes pour le montage d'essai, pour les charges spéciales.
Elektromehanski osnovni releji - 1. del: Splošne zahteve (IEC 61810-1:2008)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2008
1DGRPHãþD
SIST EN 61810-1:2004
Elektromehanski osnovni releji - 1. del: Splošne zahteve (IEC 61810-1:2008)
Electromechanical elementary relays - Part 1: General requirements
Elektromechanische Elementarrelais (elektromechanische Schaltrelais ohne festgelegtes
Zeitverhalten) - Teil 1: Allgemeine Anforderungen
Relais électromécaniques élémentaires - Partie 1: Exigences générales
Ta slovenski standard je istoveten z: EN 61810-1:2008
ICS:
29.120.70 Releji Relays
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 61810-1
NORME EUROPÉENNE
June 2008
EUROPÄISCHE NORM
ICS 29.120.70 Supersedes EN 61810-1:2004
English version
Electromechanical elementary relays -
Part 1: General requirements
(IEC 61810-1:2008)
Relais électromécaniques élémentaires - Elektromechanische Elementarrelais -
Partie 1: Exigences générales Teil 1: Allgemeine Anforderungen
(CEI 61810-1:2008) (IEC 61810-1:2008)
This European Standard was approved by CENELEC on 2008-05-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in two official versions (English and German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61810-1:2008 E
Foreword
The text of document 94/267/FDIS, future edition 3 of IEC 61810-1, prepared by IEC TC 94,
All-or-nothing electrical relays, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as EN 61810-1 on 2008-05-01.
This European Standard supersedes EN 61810-1:2004.
The relevant modifications compared to EN 61810-1:2004 are:
– update of references;
– renumbering of clauses to bring them into a more logical order;
– inclusion of contact load categories (same as in EN 61810-2 and EN 61810-7);
– clarifications concerning electrical endurance (Clause 11);
– inclusion of provisions for insulation coordination in accordance with the basic safety standards
EN 60664-3, EN 60664-4 and EN 60664-5 (Clause 13);
– renumbering of all annexes in the order they are referenced in the body of the standard;
– inclusion of new Annex C (normative) for the test set-up, and new Annex D (informative) for special
loads (based upon similar annexes in EN 61810-2 and EN 61810-7);
– improvement of Annex B covering inductive contact loads.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-02-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2011-05-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61810-1:2008 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60335-1 + A1 NOTE Harmonized as EN 60335-1:2002 (modified) + A1:2004 (not modified) .
IEC 60695-11-5 NOTE Harmonized as EN 60695-11-5:2005 (not modified).
IEC 60730-1 + A1 NOTE Harmonized as EN 60730-1:1995 (modified) + A1:1997 (modified).
IEC 60947-5-1 NOTE Harmonized as EN 60947-5-1:2004 (not modified).
IEC 60950-1 NOTE Harmonized as EN 60950-1:2006 (modified).
___________
- 3 - EN 61810-1:2008
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
1)
IEC 60038 (mod) 1983 IEC standard voltages HD 472 S1 1989
- - + corr. February 2002
- - A1 1995
A1 1994
A2 1997
IEC 60050 Series International Electrotechnical Vocabulary - -
(IEV)
IEC 60068-2-2 2007 Environmental testing - EN 60068-2-2 2007
Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-17 1994 Environmental testing - EN 60068-2-17 1994
Part 2: Tests - Test Q: Sealing
IEC 60068-2-20 1979 Environmental testing -
+ A2 1987 Part 2: Tests - Test T: Soldering HD 323.2.20 S3 1988
2)
IEC 60085 2004 Electrical insulation - Thermal classification EN 60085 2004
IEC 60112 2003 Method for the determination of the proof EN 60112 2003
and the comparative tracking indices of solid
insulating materials
IEC 60364-4-44 2007 Low voltage electrical installations - - -
Part 4-44: Protection for safety - Protection
against voltage disturbances and
electromagnetic disturbances
IEC 60417 Data- Graphical symbols for use on equipment - -
base
IEC 60664-1 2007 Insulation coordination for equipment within EN 60664-1 2007
low-voltage systems -
Part 1: Principles, requirements and tests
IEC 60664-3 2003 Insulation coordination for equipment within EN 60664-3 2003
low-voltage systems -
Part 3: Use of coating, potting or moulding for
protection against pollution
IEC 60664-4 2005 Insulation coordination for equipment within EN 60664-4 2006
low-voltage systems - + corr. October 2006
Part 4: Consideration of high-frequency
voltage stress
1)
The title of HD 472 S1 is: Nominal voltages for low voltage public electricity supply systems.
2)
EN 60085 is superseded by EN 60085:2008, which is based on IEC 60085:2007.
Publication Year Title EN/HD Year
IEC 60664-5 2007 Insulation coordination for equipment within EN 60664-5 2007
low-voltage systems -
Part 5: Comprehensive method for
determining clearances and creepage
distances equal to or less than 2 mm
IEC 60695-2-10 2000 Fire hazard testing - EN 60695-2-10 2001
Part 2-10: Glowing/hot-wire based test
methods - Glow-wire apparatus and common
test procedure
IEC 60695-2-11 2000 Fire hazard testing - EN 60695-2-11 2001
Part 2-11: Glowing/hot-wire based test
methods - Glow-wire flammability test method
for end-products
IEC 60695-2-12 2000 Fire hazard testing - EN 60695-2-12 2001
Part 2-12: Glowing/hot-wire based test
methods - Glow-wire flammability test method
for materials
IEC 60695-2-13 2000 Fire hazard testing - EN 60695-2-13 2001
Part 2-13: Glowing/hot-wire based test
methods - Glow-wire ignitability test method
for materials
IEC 60695-10-2 2003 Fire hazard testing - EN 60695-10-2 2003
Part 10-2: Abnormal heat - Ball pressure test
IEC 60721-3-3 1994 Classification of environmental conditions - EN 60721-3-3 1995
A1 1995 Part 3: Classification of groups of - -
A2 1996 environmental parameters and their A2 1997
severities -
Section 3: Stationary use at weatherprotected
locations
IEC 60999-1 1999 Connecting devices - Electrical copper EN 60999-1 2000
conductors - Safety requirements for
screw-type and screwless-type clamping
units -
Part 1: General requirements and particular
requirements for clamping units for conductors
from 0,2 mm² up to 35 mm² (included)
IEC 61210 (mod) 1993 Connecting devices - Flat quick-connect EN 61210 1995
terminations for electrical copper conductors -
Safety requirements
IEC 61760-1 2006 Surface mounting technology - EN 61760-1 2006
Part 1: Standard method for the specification
of surface mounting components (SMDs)
IEC 61984 2001 Connectors - Safety requirements and tests EN 61984 2001
IEC 61810-1
Edition 3.0 2008-02
INTERNATIONAL
STANDARD
Electromechanical elementary relays –
Part 1: General requirements
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XB
ICS 29.120.70 ISBN 2-8318-9586-3
– 2 – 61810-1 © IEC:2008(E)
CONTENTS
FOREWORD.5
1 Scope.7
2 Normative references .7
3 Terms and definitions .8
3.1 Definitions related to general terms .9
3.2 Definitions of relay types .9
3.3 Definitions related to conditions and operations.10
3.4 Definitions of operating values .12
3.5 Definitions related to contacts .13
3.6 Definitions related to accessories .16
3.7 Definitions related to insulation .16
4 Influence quantities .18
5 Rated values .18
5.1 Rated coil voltage/rated coil voltage range .18
5.2 Operative range .19
5.3 Release.19
5.4 Reset .19
5.5 Electrical endurance.19
5.6 Frequency of operation.19
5.7 Contact loads .20
5.8 Ambient temperature .20
5.9 Categories of environmental protection .20
5.10 Duty factor .20
6 General provisions for testing .20
7 Documentation and marking .22
7.1 Data .22
7.2 Additional data .23
7.3 Marking .23
7.4 Symbols .23
8 Heating .24
8.1 Requirements.24
8.2 Test procedure .25
8.3 Terminals .26
8.3.1 General .26
8.3.2 Solder terminals .26
8.3.3 Flat quick-connect terminations .26
8.3.4 Screw and screwless type terminals .27
8.3.5 Alternative termination types .27
8.3.6 Sockets .27
9 Basic operating function .27
9.1 General test conditions.27
9.2 Operate (monostable relays) .
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.