Electricity metering data exchange - The DLMS/COSEM suite - Part 8-7: AMC-SS PLC communication profile for neighbourhood networks

This Technical Specification is part of the EN 62056 / 52056 DLMS/COSEM suite and specifies the DLMS/COSEM communication profile for compatibly extendable power line carrier neighbourhood networks using Adaptive Multi-Carrier Spread-Spectrum (AMC-SS). The physical layer provides a modulation technique that efficiently utilizes the allowed bandwidth within the CENELEC A band (3 kHz – 95 kHz), offering a very robust communication in the presence of narrowband interference, impulsive noise, and frequency selective attenuation. The physical layer of AMC-SS is defined in Clause 5 of CLC/FprTS 50590:2014. The data link (DL) layer consists of three parts, the ‘Medium Access Control’ (MAC) sub-layer, the Logical Link Control (LLC) sub-layer and the ‘Convergence’ sub-layer. The data link layer allows the transmission of data frames through the use of the power line physical channel. It provides data services, frame integrity control, routing, registration, multiple access, and cell change functionality. The MAC sub-layer and the LLC sub-layer of AMC-SS are defined in Clause 6 of CLC/FprTS 50590:2014. The Convergence sub-layer is defined in this document. The transport layer, the application layer and the data model are as specified in the EN 62056 DLMS/COSEM suite.

Echange des données de comptage de l'électricité - La suite DLMS/COSEM - Partie 8-7: Profil de communication PLC AMC-SS pour les réseaux de voisinage

Izmenjava podatkov pri merjenju električne energije - Niz DLMS/COSEM - 8-7. del: PLC-profil z adaptivnim spektrom z več nosilnimi frekvencami za omrežja CX1

General Information

Status
Published
Publication Date
23-Apr-2015
Current Stage
9093 - Decision to confirm - Review Enquiry
Completion Date
09-Oct-2019

Buy Standard

Technical specification
TS CLC/TS 52056-8-7:2015 - BARVE
English language
42 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2015
,]PHQMDYDSRGDWNRYSULPHUMHQMXHOHNWULþQHHQHUJLMH1L]'/06&26(0GHO
3/&SURILO]DGDSWLYQLPVSHNWURP]YHþQRVLOQLPLIUHNYHQFDPL]DRPUHåMD&;
Electricity metering data exchange - The DLMS/COSEM suite - Part 8-7: The adaptive
multi-carrier spread-spectrum PLC profile for CX1 networks
Ta slovenski standard je istoveten z: CLC/TS 52056-8-7:2015
ICS:
35.240.50 Uporabniške rešitve IT v IT applications in industry
industriji
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

TECHNICAL SPECIFICATION CLC/TS 52056-8-7

SPÉCIFICATION TECHNIQUE
TECHNISCHE SPEZIFIKATION
April 2015
ICS 35.240.60; 91.140.50
English Version
Electricity metering data exchange - The DLMS/COSEM suite -
Part 8-7: AMC-SS PLC communication profile for neighbourhood
networks
This Technical Specification was approved by CENELEC on 2014-11-11.

CENELEC members are required to announce the existence of this TS in the same way as for an EN and to make the TS available promptly
at national level in an appropriate form. It is permissible to keep conflicting national standards in force.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. CLC/TS 52056-8-7:2015 E

CONTENTS
Foreword . 4
1 Scope . 5
2 Normative references . 5
3 Abbreviations . 6
4 Targeted communication environments . 8
5 Reference model . 9
6 Physical Layer (PHY) . 10
6.1 Overview – main features and functions . 10
6.2 PHY layer services . 10
7 Data Link Layer . 11
7.1 Functions and structure . 11
7.2 The Medium Access Control sub-layer. 13
7.3 The Logical Link Control sub-layer . 13
7.3.1 Overview . 13
7.3.2 Layer-2-network management functions . 13
7.3.3 Communication functions . 14
7.3.4 Segmentation and reassembly . 14
7.4 The Convergence sub-layer . 14
7.4.1 Overview . 14
7.4.2 DLMS/COSEM AL specific convergence sub-layer . 14
7.4.3 IPv4 specific convergence sub-layer . 19
7.4.4 IPv6 specific convergence sub-layer . 26
7.5 Identification and addressing . 32
8 Upper layers (Session, Presentation, Application) . 33
8.1 Overview . 33
8.2 Mapping of application layer services . 34
8.3 Registration services . 35
8.3.1 Overview . 35
8.3.2 CL_control.indication . 35
8.3.3 CL_IPv4_control.indication . 36
8.3.4 CL_IPv6_control.indication . 37
9 Data Model . 38
Annex A (normative) IP header compression parameters. . 39
Annex B (informative) Data exchange examples . 40
B.1 Data retrieval from slave node . 40
B.2 Data retrieval error case . 41

List of Figures
Figure 1 – Communication architecture . 8
Figure 2 – DLMS/COSEM AMC-SS PLC architecture . 9
Figure 3 – Primitives between layer 2 and layer 1 . 11
Figure 4 – Structure of Data Link Layer . 11
Figure 5 – DLMS/COSEM AL specific primitives between higher layer and layer 2 in a
bidirectional data transmission . 12

– 3 – CLC/TS 52056-8-7:2015
Figure 6 – DLMS/COSEM AL specific primitives between higher layer and layer 2 in
the case of broadcast . 12
Figure 7 – DLMS/COSEM AL specific primitives between higher layers and layer 2 in
the case of an unsolicited data transmission . 13
Figure 8 – The IPv4 communication architecture . 20
Figure 9 – The IPv6 communication architecture . 26
Figure 10 – Mapping of the DLMS/COSEM Application layer services . 34
Figure 11 – Registration services specific for DLMS/COSEM AL . 36
Figure 12 – IPv4 registration services . 37
Figure 13 – IPv6 registration services . 38
Figure B 1 – Successful GET command specific for DLMS/COSEM AL . 40
Figure B 2 – Data retrieval error case specific for DLMS/COSEM AL . 41
List of Tables
Table 1 – Coding of the DLC extended control field . 14
Table 2 – Mapping of CL_data.request to DL_data.request in the master node . 15
Table 3 – Mapping of CL_data.request to DL_data.request in the slave node . 16
Table 4 – Mapping of DL_data.indication to CL_data.indication in the master node. 17
Table 5 – Mapping of DL_data.indication to CL_data.indication in the slave node . 17
Table 6 – Mapping of DL_data_identifier.confirm to CL_data_request.confirm in the
master node . 18
Table 7 – Mapping of DL_data_identifier.confirm to CL_data_request.confirm in the
slave node . 19
Table 8 – Reserved SAP values on the master node side . 19
Table 9 – Reserved SAP values on the slave node side . 19
Table 10 – Mapping of CL_IPv4_data.request to DL_data.request in the master node . 21
Table 11 – Mapping of CL_IPv4_data.request to DL_data.request in the slave node . 22
Table 12 – Mapping of DL_data.indication to CL_IPv4_data.indication in the master
node . 23
Table 13 – Mapping of DL_data.indication to CL_IPv4_data.indication in the slave
node . 23
Table 14 – Mapping of DL_data_identifier.confirm to CL_IPv4_data_request.confirm in
the master node . 25
Table 15 – Mapping of DL_data_identifier.confirm to CL_IPv4_data_request.confirm in
the slave node . 25
Table 16 – Mapping of CL_IPv6_data.request to DL_data.request in the master node . 28
Table 17 – Mapping of CL_IPv6_data.request to DL_data.request in the slave node . 28
Table 18 – Mapping of DL_data.indication to CL_IPv6_data.indication in the master
node . 29
Table 19 – Mapping of DL_data.indication to CL_IPv6_data.indication in the slave
node . 30
Table 20 – Mapping of DL_data_identifier.confirm to CL_IPv6_data_request.confirm in
the master node . 31
Table 21 – Mapping of DL_data_identifier.confirm to CL_IPv6_data_request.confirm in
the slave node . 32
Table 22 – Mapping of DL_control.indication to CL_control.indication . 36
Table 23 – Mapping of DL_control.indication to CL_IPv4_control.indication . 37
Table 24 – Mapping of DL_control.indication to CL_IPv6_control.indication . 38

Foreword
This document (CLC/TS 52056-8-7:2015) has been prepared by CLC/TC 13 "Electrical energy
measurement and control".
The following date is fixed:
(doa) 2015-07-24
• latest date by which the existence of
this document has to be announced
at national level
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association.

– 5 – CLC/TS 52056-8-7:2015
1 Scope
This Technical Specification specifies the DLMS/COSEM communication profile using a
compatibly-extendable form (CX1) of Adaptive Multi-Carrier Spread-Spectrum (AMC-SS) PLC
for neighbourhood networks. Its structure is in line with the DLMS/COSEM framework as
described in EN 62056-1-0[GK1].
The transport layer, the application layer and the data model are as specified in the EN 62056
DLMS/COSEM suite.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
CLC/TS 50590:2015, Electricity metering data exchange - Lower layer PLC profile using
Adaptive Multi-Carrier Spread-Spectrum for CX1 networks
EN 61334-4-32:1996, Distribution automation using distribution line carrier systems – Part 4 :
Data communication protocols – Section 32: Data link layer – Logical link control (LLC)
(IEC 61334-4-32:1996)
EN 61334-4-1:1996, Distribution automation using distribution line carrier systems – Part 4 :
Data communication protocols – Section 1: Reference model of the communication system
(IEC 61334-4-1:1996)
EN 62056-5-3, Electricity metering data exchange – The DLMS/COSEM suite – Part 5-3:
DLMS/COSEM application layer (IEC 62056-5-3)
EN 62056-6-1, Electricity metering data exchange – The DLMS/COSEM suite – Part 61: OBI
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.