Abstract

This European Standard deals with the safety of microwave ovens for household and similar use, their rated voltage being not more than 250 V.

Status
Not Published
Publication Date
04-May-2027
Current Stage
4599 - Dispatch of FV draft to CMC - Finalization for Vote
Start Date
06-Oct-2026
Due Date
21-Jul-2026
Completion Date
21-Jul-2026

Buy Documents

Draft

prEN IEC 60335-2-25:2026

English language (49 pages)
Preview
Preview
e-Library read for
×1 day

FprEN IEC 60335-2-25:2026 is a CENELEC draft European Standard for the safety of microwave ovens for household and similar use, with rated voltage not more than 250 V. It sets particular safety requirements for microwave ovens, including combination microwave ovens, and is based on IEC 60335-2-25:2024.

What does FprEN IEC 60335-2-25:2026 specify?

FprEN IEC 60335-2-25:2026 covers microwave ovens for household and similar use, including DC supplied and battery-operated appliances. It also covers combination microwave ovens and microwave ovens intended to be used on board ships.

The scope includes appliances used by laypersons in places such as shops, light industry and farms when they can create a public safety risk. It excludes commercial microwave ovens, commercial microwave appliances with insertion or contacting applicators, industrial microwave heating equipment, medical appliances, and appliances used where special conditions prevail, such as corrosive or explosive atmospheres.

The document follows the Part 1 structure and adds, modifies or replaces requirements where microwave ovens need special treatment. Its main body runs through Clauses 1 to 32, with annexes for routine tests, battery-operated appliances, software evaluation, combination microwave ovens, and shipboard use.

AnnexWhat it covers
ARoutine tests
BBattery-operated appliances, separable batteries and detachable batteries
RSoftware evaluation
AACombination microwave ovens
BBMicrowave ovens intended to be used on board ships

What are the key requirements of FprEN IEC 60335-2-25:2026?

Marking, instructions and normal use

FprEN IEC 60335-2-25:2026 requires clear marking and operating instructions so users understand the microwave-specific risks. Clause 7 adds marking for the nominal ISM band frequency, warning labels for covers that expose microwave energy, and hot-surface marking where needed.

The instructions have to cover practical safety matters such as door damage, repair by competent persons, sealed containers, unsuitable utensils, combustible storage in the cavity, smoke, delayed boiling, food in feeding bottles, egg heating, cleaning and the use of a recommended temperature probe. For manufacturers and buyers, this matters because compliance depends not only on the appliance design but also on the information delivered with the product.

Heating, surface temperature and microwave leakage

Clause 11 defines the heating test for microwave ovens as three operating cycles with water load, including rest periods and load replacement. The clause also sets how to measure temperature rises on accessible surfaces and adds Table 101, which gives surface temperature-rise limits according to installation height and surface material.

In practice, this means the design has to stay safe both in operation and in the places where users can touch the appliance. Clause 32.1 then checks microwave leakage with a defined water load and a scan over the external surfaces, with a limit of 50 W/m at points 50 mm or more from the appliance surface. That is the core test for shielding, door sealing and overall radiation containment.

Moisture resistance and spillage

Clause 15 adds tests for water exposure that are especially relevant for built-in ovens and temperature-sensing probes. The document includes a spillage test over the shelf, a water-immersion and thermal cycling test for temperature-sensing probes, and two separate spillage tests for built-in appliances under work surfaces or under other built-in appliances.

These tests matter because microwave ovens are often installed in kitchens where liquid spills can reach openings, controls and insulation. A compliant design has to keep clearances, creepage distances and electrical insulation intact after realistic kitchen spillage.

Door safety, interlocks and endurance

Clause 18 subjects the door system, including hinges and microwave seals, to long cycling before leakage is checked again. The door has to withstand repeated opening and closing in normal use and still keep microwave leakage within limits.

Clauses 22.103 to 22.115 focus on door interlocks, concealed interlocks, monitored interlocks and protection against defeat or accidental access. The standard also checks contamination of seals, distortion at the corners, trapped probes or cords, removable parts, and access through the viewing screen. In practice, this is the main safety zone for preventing exposure while the cavity is accessible or almost accessible.

Abnormal operation, faults and control logic

Clause 19 replaces the generic abnormal-operation sequence with microwave-specific fault tests. These include no-load and short-circuit situations, simulated component failures, the effect of interrupted magnetron circuits, and a potato ignition test that checks whether a fire stays contained within the appliance.

The standard also requires attention to programmable electronic circuits in Clause 22.121 and Annex R, so software-controlled safety functions cannot fail in a way that removes microwave-leakage protection. For engineers, this means the control logic and safety hardware are part of the safety case, not just the mechanical structure.

Special installations

Clause 20 adds stability checks for bottom-hinged doors that can carry a load, and Clause 21 adds mechanical strength tests for hinges, doors and glass panels. Clause 22.116 adds vibration testing for appliances intended for road vehicles, caravans and similar vehicles, while Annex BB adds shock, vibration and corrosion tests for shipboard use.

What terms does FprEN IEC 60335-2-25:2026 define?

  • Microwave oven - an appliance that uses electromagnetic energy in ISM frequency bands between 300 MHz and 30 GHz to heat food and beverages in a cavity.
  • Combination microwave oven - a microwave oven in which resistive heating elements also provide heat in the cavity, either at the same time or one after the other.
  • Cavity - the enclosed space inside the oven where the load is placed.
  • Shelf - the horizontal support in the cavity that carries the load during testing and normal use.
  • Door interlock - a device or system that stops the microwave generator unless the door is closed.
  • Monitored door interlock - a door interlock with a supervision device that checks its switching function.
  • Temperature-sensing probe - a probe inserted into food to measure temperature as part of oven control.
  • Dayroom - an area on board ship that is exposed to the marine environment from time to time.

Who uses FprEN IEC 60335-2-25:2026?

FprEN IEC 60335-2-25:2026 is used by microwave oven manufacturers, component suppliers, test laboratories, certification bodies and compliance teams. It is also relevant to importers, buyers and quality managers who need to check whether a household, built-in, combination or shipboard microwave oven meets the right safety standard.

The document is especially useful for teams dealing with door systems, interlocks, leakage control, built-in installations, temperature probes and software-controlled safety functions. It also matters for product lines intended for kitchens, mobile installations, caravans and ships.

What changed in FprEN IEC 60335-2-25:2026 from the previous edition?

FprEN IEC 60335-2-25:2026 supersedes EN IEC 60335-2-25:2021 and EN IEC 60335-2-25:2021/A11:2021. The text is based on IEC 60335-2-25:2024 and is described as a technical revision.

The edition states these significant changes:

  • requirements for appliance outlets and socket-outlets were modified;
  • Clause 7.12 was clarified;
  • test probe 19 was adopted in 8.1.1 and 20.2;
  • 10.1 and 10.2 were clarified for inverter type microwave ovens;
  • maximum temperature rises for external accessible surfaces were added in 11.8 and Table 101;
  • the criterion in 15.101 was changed and 15.102 was harmonized with IEC 60335-2-6;
  • several clauses were clarified, including 8.1.3, 15.103, 19.11.2, 19.13, 22.105, 22.106, 22.111 and Figure 101;
  • test probe 18 was adopted in 22.103.2, 22.105 and 22.120;
  • 16.101 and 22.119 were reorganized so their subordinate content sits directly under the main subclause.

Which standards are used with FprEN IEC 60335-2-25:2026?

StandardWhat it contributes
IEC 60335-1The base safety standard that this part supplements and modifies.
IEC 60068-2-6Sinusoidal vibration testing for road-vehicle and shipboard applications.
IEC 60068-2-27Half-sine shock testing for shipboard applications.
IEC 60068-2-52Salt mist corrosion testing for shipboard use.
IEC 60335-2-6Additional requirements for stationary combination microwave ovens in Annex AA.
IEC 60335-2-9Additional requirements for portable combination microwave ovens in Annex AA.
IEC 60584-1Thermocouple specifications used in the surface-temperature probe.
IEC 61032Test probes 18, 19 and B used in access and concealment checks.
IEC 60068-2-75Pendulum hammer test used for enhanced mechanical strength of glass panels.
IEC 60335-2-90, IEC 60335-2-110, IEC 60519-6Related exclusions for commercial and industrial microwave equipment.

What does the FprEN IEC 60335-2-25:2026 document contain?

The document contains the full clause structure for safety testing, including marking, access to live parts, heating, moisture resistance, endurance, abnormal operation, construction, mechanical strength and radiation hazards. It also includes Table 101 for surface temperature-rise limits.

Several figures support the test methods, including the rod for door-interlock concealment, the tilted test cabinet, the temperature probe, the excluded door and vent zones, and the spillage-test arrangements. These figures are used to make the tests repeatable in design verification and type testing.

Annex A provides routine tests and microwave leakage instrument checks, while Annex R covers software evaluation of programmable electronic circuits. Annex AA adapts the standard to combination microwave ovens, and Annex BB adapts it to microwave ovens intended for board ships, including shock, vibration and corrosion testing.

Relations

Effective Date
10-Feb-2026
Effective Date
10-Feb-2026
Effective Date
10-Feb-2026
Effective Date
10-Feb-2026
Effective Date
10-Feb-2026
Effective Date
10-Feb-2026
Effective Date
10-Sep-2024
Effective Date
30-Jul-2024
Effective Date
30-Jul-2024

Buy Documents

Draft

prEN IEC 60335-2-25:2026

English language (49 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

FprEN IEC 60335-2-25:2026 is a draft published by CLC. Its full title is "Household and similar electrical appliances - Safety - Part 2-25: Particular requirements for microwave ovens, including combination microwave ovens". This standard covers: This European Standard deals with the safety of microwave ovens for household and similar use, their rated voltage being not more than 250 V.

This European Standard deals with the safety of microwave ovens for household and similar use, their rated voltage being not more than 250 V.

FprEN IEC 60335-2-25:2026 is classified under the following ICS (International Classification for Standards) categories: 13.120 - Domestic safety; 97.040.20 - Cooking ranges, working tables, ovens and similar appliances. The ICS classification helps identify the subject area and facilitates finding related standards.

FprEN IEC 60335-2-25:2026 has the following relationships with other standards: It is inter standard links to EN 60068-2-6:2008, EN 60068-2-27:2009, EN IEC 60335-2-9:2023, EN IEC 60068-2-52:2018, EN 60584-1:2013, FprEN IEC 60335-2-6:2026, FprEN IEC 60335-2-25:2026/FprAA:2026, EN IEC 60335-2-25:2021, EN IEC 60335-2-25:2021/A11:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

FprEN IEC 60335-2-25:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU, 2014/53/EU, 2014/55/EU; Standardization Mandates: M/511, M/536, M/585. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

FprEN IEC 60335-2-25:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 Definitions relating to physical characteristics
  • 3.1.9 normal operation
  • 3.5 Definitions relating to types of appliances
  • 3.6 Definitions relating to parts of an appliance
  • 3.8 Definitions relating to miscellaneous matters
  • 4 General requirement
  • 5 General conditions for the tests
  • 6 Classification
  • 7 Marking and instructions
  • 8 Protection against access to live parts
  • 9 Starting of motor-operated appliances
  • 10 Power input and current
  • 11 Heating
  • 12 Charging of metal-ion batteries
  • 13 Leakage current and electric strength at operating temperature
  • 14 Transient overvoltages
  • 15 Moisture resistance
  • 16 Leakage current and electric strength
  • 17 Overload protection of transformers and associated circuits
  • 18 Endurance
  • 19 Abnormal operation
  • 20 Stability and mechanical hazards
  • 21 Mechanical strength
  • 22 Construction
  • 23 Internal wiring
  • 24 Components
  • 25 Supply connection and external flexible cords
  • 26 Terminals for external conductors
  • 27 Provision for earthing
  • 28 Screws and connections
  • 29 Clearances, creepage distances and solid insulation
  • 30 Resistance to heat and fire
  • 31 Resistance to rusting
  • 32 Radiation, toxicity and similar hazards
  • Annex A
  • Annex B
  • Annex R
  • Annex AA
  • 1 Scope
  • 3 Terms and definitions
  • 3.1.9 normal operation
  • 5 General conditions for the tests
  • 7 Marking and instructions
  • 11 Heating
  • 15 Moisture resistance
  • 18 Endurance
  • 19 Abnormal operation
  • 22 Construction
  • 29 Clearances, creepage distances and solid insulation
  • Annex BB
  • 6 Classification
  • 7 Marking and instructions
  • 22 Construction
  • 31 Resistance to rusting
  • Bibliography

INTRODUCTION It has been assumed in the drafting of this International Standard that the execution of its provisions is entrusted to appropriately qualified and experienced persons. Guidance documents concerning the application of the safety requirements for appliances can be accessed via TC 61 and SC 61B supporting documents on the IEC website https://www.iec.ch/tc61/supportingdocuments https://www.iec.ch/sc61b/supportingdocuments This information is given for the convenience of users of this International Standard and does not constitute a replacement for the normative text in this standard. This standard recognizes the internationally accepted level of protection against hazards such as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal use taking into account the manufacturer's instructions. It also covers abnormal situations that can be expected in practice and takes into account the way in which electromagnetic phenomena can affect the safe operation of appliances.

This standard takes into account the requirements of IEC 60364 as far as possible so that there is compatibility with the wiring rules when the appliance is connected to the supply mains. However, national wiring rules can differ.

If an appliance within the scope of this standard also incorporates functions that are covered by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as is reasonable. If applicable, the influence of one function on the other is taken into account.

When a part 2 standard does not include additional requirements to cover hazards dealt with in Part 1, Part 1 applies.

NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is not necessary to specify particular requirements for the appliance in question over and above the general requirements.

This standard is a product family standard dealing with the safety of appliances and takes precedence over horizontal and generic standards covering the same subject. NOTE 2 Horizontal publications, basic safety publications and group safety publications covering a hazard are not applicable since they have been taken into consideration when developing the general and particular requirements for the IEC 60335 series of standards.

An appliance that complies with the text of this standard will not necessarily be considered to comply with the safety principles of the standard if, when examined and tested, it is found to have other features which impair the level of safety covered by these requirements. An appliance employing materials or having forms of construction differing from those detailed in the requirements of this standard can be examined and tested according to the intent of the requirements and, if found to be substantially equivalent, may be considered to comply with the standard.

NOTE 3 Standards dealing with non-safety aspects of household appliances are:

  • IEC standards published by TC 59 concerning methods of measuring performance;
  • CISPR 11, CISPR 14-1 and relevant IEC 61000-3 series standards concerning electromagnetic emissions;
  • CISPR 14-2 concerning electromagnetic immunity;
  • IEC standards published by TC 111 concerning environmental matters.

oSIST prEN IEC 60335-2-25:2026

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES – SAFETY –

Part 2-25: Particular requirements for microwave ovens, including combination microwave ovens

1 Scope

This clause of Part 1 is replaced by the following.

This part of IEC 60335 deals with the safety of microwave ovens for household and similar use, their rated voltage being not more than 250 V including direct current (DC) supplied appliances and battery-operated appliances.

This standard also deals with combination microwave ovens, for which normative Annex AA is applicable.

This standard also deals with microwave ovens intended to be used on board ships, for which normative Annex BB is applicable.

Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. However, if the appliance is intended to be used professionally to process food for commercial purposes, the appliance is not considered to be for household and similar use only.

As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account - persons (including children) whose - physical, sensory or mental capabilities; or - lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction; - children playing with the appliance.

Attention is drawn to the fact that - for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary; - in many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities. This standard does not apply to - commercial microwave ovens (IEC 60335-2-90); - commercial microwave appliances with insertion or contacting applicators (IEC 60335-2-110); - industrial microwave heating equipment (IEC 60519-6); - appliances for medical purposes (IEC 60601); - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).

oSIST prEN IEC 60335-2-25:2026

2 Normative references

This clause of Part 1 is applicable except as follows.

Addition:

IEC 60068-2-6, Environmental testing – Part 2: Tests – Test Fc: Vibration (sinusoidal) IEC 60068-2-27, Environmental testing – Part 2-27: Tests – Test Ea and guidance: Shock IEC 60068-2-52, Environmental testing – Part 2-52: Tests – Test Kb: Salt mist, cyclic (sodium chloride solution)

IEC 60335-2-6:— , Household and similar electrical appliances – Safety – Part 2-6: Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances IEC 60335-2-9, Household and similar electrical appliances – Safety – Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances IEC 60584-1, Thermocouples – Part 1: EMF specifications and tolerances

3 Terms and definitions

This clause of Part 1 is applicable except as follows.

3.1 Definitions relating to physical characteristics

3.1.7 Note 101 to entry: The rated frequency is the input frequency.

3.1.9 normal operation

Modification:

Replace the first paragraph by the following:

operation of the appliance with 1 000 g ± 50 g of potable water at an initial temperature of 20 °C ± 2 °C in a cylindrical borosilicate glass vessel having a maximum thickness of 3 mm and an outside diameter of approximately 190 mm, the vessel being placed on the centre of the shelf

3.5 Definitions relating to types of appliances

3.5.101 microwave oven appliance using electromagnetic energy in one or several of the ISM frequency bands between 300 MHz and 30 GHz, for heating food and beverages in a cavity Note 1 to entry: ISM frequency bands are the electromagnetic frequencies established by the ITU and reproduced in CISPR 11.

Under preparation. Stage at the time of publication: IEC/FDIS 60335-2-6:2024.

oSIST prEN IEC 60335-2-25:2026

3.5.102 combination microwave oven microwave oven in which heat is also provided in the cavity by simultaneous or consecutive operation of resistive heating elements Note 1 to entry: The resistive heating elements are used to provide radiant heat, convection heat or steam.

3.6 Definitions relating to parts of an appliance

3.6.101 cavity space enclosed by the inner walls and the door in which the load is placed 3.6.102 shelf horizontal support in the cavity on which the load is placed 3.6.103 door interlock device or system that prevents the operation of the microwave generator(s), unless the oven door is closed 3.6.104 monitored door interlock door interlock system that incorporates a supervision device 3.6.105 temperature-sensing probe device that is inserted into the food to measure its temperature and is a part of an oven control

3.8 Definitions relating to miscellaneous matters

3.8.101 open deck area that is exposed to marine environment 3.8.102 dayroom area that can be exposed to marine environment from time to time

4 General requirement

This clause of Part 1 is applicable.

5 General conditions for the tests

This clause of Part 1 is applicable except as follows.

5.2 Addition:

An additional sample can be required for the test of 19.104.

Six samples of the interlocks are required for the test of 24.1.4.

oSIST prEN IEC 60335-2-25:2026

5.3 Modification:

Instead of carrying out the tests in the order of clauses, the following sequence of clauses and subclauses applies: 32.1, 22.113, 22.108, 22.115, 22.116, Clause 7 to 17, Clause 20, Clause 21 (except 21.101 to 21.105), Clause 18, Clause 19 (except 19.104), Clause 22 (except 22.108, 22.113, 22.115 and 22.116), Clause 23 to 31 and 32.2, 21.101 to 21.105 and 19.104. 5.101 Microwave ovens are tested as motor-operated appliances. 5.102 Class III temperature-sensing probes are only subjected to the tests of 22.112.

6 Classification

This clause of Part 1 is applicable except as follows.

6.1 Modification:

Microwave ovens shall be class I or class II.

7 Marking and instructions

This clause of Part 1 is applicable except as follows.

7.1 Addition:

Appliances shall be marked with the nominal frequency in megahertz of the ISM band in which they operate.

If the removal of any cover results in microwave leakage exceeding the value specified in 32.1, the cover shall be marked with the substance of the following:

WARNING MICROWAVE ENERGY DO NOT REMOVE THIS COVER When the exempted provisions of footnote b to Table 101 and/or Table 3 apply, the appliance shall be marked with the substance of "CAUTION: Hot surface", or symbol IEC 60417-5041 (2002-10).

7.6 Addition:

[symbol IEC 60417-5041 caution, hot surface (2002-10)]

7.12 Addition:

The instructions shall include the substance of the following warnings:

  • WARNING: If the door or door seals are damaged, the oven must not be operated until it has been repaired by a competent person.

oSIST prEN IEC 60335-2-25:2026

  • WARNING: It is hazardous for anyone other than a competent person to carry out any service or repair operation that involves the removal of a cover which gives protection against exposure to microwave energy.

NOTE 101 This warning is applicable if microwave leakage exceeds the limit specified in 32.1 during the removal of any cover.

  • WARNING: Liquids and other foods must not be heated in sealed containers since they are liable to explode.
  • WARNING: Ensure that the cavity does not contain any items or utensils that are not suitable for the use with the microwave oven before you operate the appliance.
  • WARNING: Do not use the cavity for storing combustible products, cooking utensils, or food and similar when the microwave oven is not in use.

The instructions shall include the substance of the following:

  • This appliance is intended to be used in household and similar applications such as:
  • staff kitchen areas in shops, offices and other working environments;
  • farm houses;
  • by clients in hotels, motels and other residential environments;
  • bed and breakfast type environments.

If the manufacturer wishes to limit the use of the appliance to less than the above, this shall be clearly stated in the instructions.

  • The minimum height of free space necessary above the top surface of the oven.
  • Metallic containers for food and beverages are not allowed during microwave cooking. This requirement is not applicable if the manufacturer specifies size and shape of metallic containers suitable for microwave cooking.
  • When heating food in plastic or paper containers, keep an eye on the oven due to the possibility of ignition.
  • The microwave oven is intended for heating food and beverages. Drying of food or clothing and heating of warming pads, slippers, sponges, damp cloth and similar can lead to risk of injury, ignition or fire.
  • If smoke is observed, switch off or unplug the appliance and keep the door closed in order to stifle any flames.
  • Microwave heating of beverages can result in delayed eruptive boiling, therefore care must be taken when handling the container.
  • The contents of feeding bottles and baby food jars shall be stirred or shaken and the temperature checked before consumption, in order to avoid burns.
  • Eggs in their shell and whole hard-boiled eggs should not be heated in microwave ovens since they can explode, even after microwave heating has ended.
  • Details for cleaning door seals, cavities and adjacent parts.
  • The oven should be cleaned regularly and any food deposits removed.
  • Failure to maintain the oven in a clean condition could lead to deterioration of the surface that could adversely affect the life of the appliance and possibly result in a hazardous situation.
  • Only use the temperature probe recommended for this oven (for appliances having a facility to use a temperature-sensing probe).
  • The instructions for use for fixed appliances and built-in appliances being used equal or higher than 900 mm above the floor and having detachable turntables shall state that care should be taken not to displace the turntable when removing containers from the appliance. This is not applicable for appliances with horizontal bottom hinged door.
  • The appliance shall not be cleaned with a steam cleaner.

If symbol IEC 60417-5041 (2002-10) is marked on the appliance, its meaning shall be explained.

oSIST prEN IEC 60335-2-25:2026

The manufacturer shall state in the instructions whether the microwave oven is allowed to be placed or installed less than 850 mm above the floor.

The manufacturer shall state in the instructions whether the microwave oven is intended to be used freestanding, built-in or in a cabinet. If the appliance can be used while placed in a cabinet, - the minimum dimensions of the cabinet shall be given by the manufacturer, and - the instructions shall state that the appliance must be operated with any cabinet door open. The instructions for microwave ovens having an additional decorative door shall state that the appliance must be operated with the decorative door open.

The instructions for microwave ovens that are not tested in a cabinet shall state that the appliance must not be placed in a cabinet.

The instructions for microwave ovens that are not in compliance with 22.118 shall state that the appliance must not be installed equal or higher than 900 mm above the floor. 7.14 Addition:

The height of the lettering of the warning specified in 7.1 shall be at least 3 mm. The height of symbol IEC 60417-5041 (2002-10) shall be at least 10 mm. Compliance is checked by measurement.

7.15 Addition:

If the hot surface marking in 7.1, or symbol IEC 60417-5041 (2002-10) is marked on the appliance, it shall be visible when the appliance is operated as in normal use, including when actuating any switch, adjusting any control or opening a lid, drawer or door. It shall not be placed on surfaces that are exempted from the limits in Table 3 and Table 101.

8 Protection against access to live parts

This clause of Part 1 is applicable except as follows.

8.1.1 Addition:

For part of appliances situated not more than 850 mm above the floor after installation or in normal use, in addition to the use of test probe 18, test probe 19 of IEC 61032 is also applied wherever test probe 18 is used and with the same test conditions used for test probe 18. 8.1.3 Addition:

Test probe 19 of IEC 61032 is not applied.

9 Starting of motor-operated appliances

This clause of Part 1 is not applicable.

oSIST prEN IEC 60335-2-25:2026

10 Power input and current

This clause of Part 1 is applicable except as follows.

10.1 Addition:

For inverter type microwave ovens, if the power input varies throughout the operating cycle, the representative period is considered as specified in 11.7 without the rest periods. For inverter type microwave ovens, if the power input does not vary throughout the operating cycle, and for non-inverter type microwave ovens, the power input is measured at the end of third operating cycle of 11.7.

10.2 Addition:

For inverter type microwave ovens, if the current varies throughout the operating cycle, the representative period is considered as specified in 11.7 without the rest periods. For inverter type microwave ovens, if the current does not vary throughout the operating cycle, and for non-inverter type microwave ovens, the current is measured at the end of the third operating cycle of 11.7.

11 Heating

This clause of Part 1 is applicable except as follows.

11.2 Addition:

Appliances, other than built-in appliances, are positioned as specified for heating appliances. A ceiling is placed over the appliance at the minimum height stated in the instructions. The ceiling has a depth of 300 mm from the back wall of the test corner and a length at least 150 mm in excess of the width of the appliance.

Appliances that can be used when placed in a cabinet are placed in a cabinet with the minimum dimension given in the instructions by the manufacturer, the plywood specified for the test corner being used. The appliance is positioned against the rear wall and one of the side walls. The cabinet door is in the open position.

11.3 Addition:

Where the external accessible surfaces are suitably flat and access permits, the test probe of Figure 104 is used to measure the temperature rises of external accessible surfaces specified in Table 101. The probe is applied with a force of 4 N ± 1 N to the surface in such a way that the best possible contact between the probe and the surface is ensured. The measurement is performed after a contact period of 30 s.

The probe can be held in place using a laboratory stand clamp or similar device. Any measuring instrument giving the same results as the probe can be used.

oSIST prEN IEC 60335-2-25:2026

11.7 Replacement:

Appliances are operated for three cycles with remote operation enabled, if any. Each cycle consisting of a heating period of 10 min followed by a rest period of 1 min. The last cycle does not include a rest period of 1 min. During the rest periods, the lid, drawer or door is open, the remote operation enabled, if any, and the load is replaced.

Appliance outlets accessible to the user and socket-outlets accessible to the user are loaded with a resistive load that gives the marked outlet load. The current in the appliance outlets and socket-outlets on the appliance are continuously loaded.

For appliances incorporating integral batteries or separable batteries not disconnected from the appliance for charging purposes:

  • the battery that has been fully discharged is charged for 1 h, while the appliance is operated as specified, if allowed by the construction of the appliance;
  • the battery that has been fully discharged is charged, for a duration of 24 h or until it is fully charged, whichever is shorter, without the battery-operated appliance performing its intended function.

11.8 Modification:

Replace the first paragraph by the following text:

During the test, the temperature rises are monitored continuously and shall not exceed the values shown in Table 3 and Table 101.

Addition:

For Table 3:

  • The temperature rises of external surfaces of microwave ovens are only measured on the surfaces that are not placed against the wall and the floor of the test corner;
  • There are no temperature rise limits for air-outlet grilles and for surfaces up to a distance of 25 mm from them.

...