Electrical apparatus for use in the presence of combustible dust - Part 1-2: Electrical apparatus protected by enclosures - Selection, installation and maintenance

This European Standard is applicable to electrical apparatus protected by enclosure and temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. This standard gives guidance on the selection, installation and maintenance of electrical apparatus. NOTE: EN 50281-1-1 specifies requirements for the design, construction and testing of electrical apparatus. The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and on the restriction of dust ingress into the enclosure by the use of dust-tight or dust-protected enclosures. The application of electrical apparatus in atmospheres that may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protection measures. The principles of this standard can also be followed when combustible fibres or flyings cause a hazard. This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This Standard is not applicable to electrical apparatus for use in mines susceptible to firedamp; nor does it take account of any risk because of an emission of flammable or toxic gas from the dust. This standard does not include other types of protection and is only applicable to protection by enclosure and temperature limitation

Elektrische Betriebsmittel zur Verwendung in Bereichen mit brennbarem Staub - Teil 1-2: Elektrische Betriebsmittel mit Schutz durch Gehäuse - Auswahl, Errichten und Instandhaltung

Matériels électriques destinés à être utilisés en présence de poussières combustibles - Partie 1-2: Matériels électriques protégés par enveloppes - Sélection, installation et entretien

Električne naprave za uporabo ob prisotnosti gorljivega prahu - 1-2. del: Električne naprave, zaščitene z ohišji - Izbira, vgraditev in vzdrževanje

General Information

Status
Withdrawn
Publication Date
08-Sep-1998
Withdrawal Date
29-Jun-2003
Parallel Committee
IEC/SC 31H - IEC_SC_31H
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Apr-2008
Completion Date
01-Apr-2008

Relations

Effective Date
29-Jan-2023
Effective Date
29-Jan-2023
Effective Date
29-Jan-2023

Get Certified

Connect with accredited certification bodies for this standard

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

CEPREI Certification Center (Guangzhou Saibao)

Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.

CNAS China Verified

CESI Beijing Certification (Saisi)

Subsidiary of China Electronics Standardization Institute (CESI), established 1963.

CNAS China Verified

Sponsored listings

Frequently Asked Questions

EN 50281-1-2:1998 is a standard published by CLC. Its full title is "Electrical apparatus for use in the presence of combustible dust - Part 1-2: Electrical apparatus protected by enclosures - Selection, installation and maintenance". This standard covers: This European Standard is applicable to electrical apparatus protected by enclosure and temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. This standard gives guidance on the selection, installation and maintenance of electrical apparatus. NOTE: EN 50281-1-1 specifies requirements for the design, construction and testing of electrical apparatus. The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and on the restriction of dust ingress into the enclosure by the use of dust-tight or dust-protected enclosures. The application of electrical apparatus in atmospheres that may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protection measures. The principles of this standard can also be followed when combustible fibres or flyings cause a hazard. This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This Standard is not applicable to electrical apparatus for use in mines susceptible to firedamp; nor does it take account of any risk because of an emission of flammable or toxic gas from the dust. This standard does not include other types of protection and is only applicable to protection by enclosure and temperature limitation

This European Standard is applicable to electrical apparatus protected by enclosure and temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. This standard gives guidance on the selection, installation and maintenance of electrical apparatus. NOTE: EN 50281-1-1 specifies requirements for the design, construction and testing of electrical apparatus. The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and on the restriction of dust ingress into the enclosure by the use of dust-tight or dust-protected enclosures. The application of electrical apparatus in atmospheres that may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protection measures. The principles of this standard can also be followed when combustible fibres or flyings cause a hazard. This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This Standard is not applicable to electrical apparatus for use in mines susceptible to firedamp; nor does it take account of any risk because of an emission of flammable or toxic gas from the dust. This standard does not include other types of protection and is only applicable to protection by enclosure and temperature limitation

EN 50281-1-2:1998 is classified under the following ICS (International Classification for Standards) categories: 29.260.20 - Electrical apparatus for explosive atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50281-1-2:1998 has the following relationships with other standards: It is inter standard links to EN 61241-17:2005, EN 61241-14:2004, EN 50281-1-2:1998/A1:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 50281-1-2:1998 is associated with the following European legislation: EU Directives/Regulations: 94/9/EC; Standardization Mandates: BC/CEN/CLC/08-92. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 50281-1-2:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI SIST EN 50281-1-2:2000
prva izdaja
STANDARD
april 2000
Električne naprave za uporabo ob prisotnosti gorljivega prahu - 1-2. del:
Električne naprave, zaščitene z ohišji - Izbira, vgraditev in vzdrževanje
Electrical apparatus for use in the presence of combustible dust - Part 1-2:
Electrical apparatus protected
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...