Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 13: Oil resistant PVC sheathed cables with two or more conductors

This part (part 13) of the HD details the particular specifications for oil resistant polyvinyl chloride insulated and sheathed flexible cables, of rated voltage (Uo/U) up to and including 300/500 V, for a maximum conductor temperature in normal operation of 70ø C. All cables shall comply with the appropriate requirements given in Part 1 and the individual types of cable shall comply with the particular requirements of this Part. NOTE: The limits for the overall diameter of the cables have been calculated in accordance with EN 60719.

Polyvinylchlorid-isolierte Leitungen mit Nennspannungen bis 450/750 V - Teil 13: Ölbeständige PVC-Steuerleitungen mit zwei oder mehr Adern

Conducteurs et câbles isolés au polychlorure de vinyle, de tension assignée au plus égale à 450/750 V - Partie 13: Câbles souples avec gaine de polychlorure de vinyle, résistant à l'huile, à deux âmes ou plus

Kabli s polivinilkloridno izolacijo za naznačene napetosti do vključno 450/750 V - 13. del: Kabli z dvema ali več vodniki, s polivinilkloridnim plaščem, odpornim proti olju

General Information

Status
Withdrawn
Publication Date
07-Sep-1995
Withdrawal Date
30-Jun-1996
Technical Committee
CLC/TC 20 - Electric cables
Drafting Committee
IEC/TC 20 - IEC_TC_20
Parallel Committee
IEC/TC 20 - IEC_TC_20
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
17-Jan-2014
Completion Date
17-Jan-2014

Relations

Effective Date
28-Jan-2023
Effective Date
29-Jan-2023

Buy Documents

Standardization document

HD 21.13 S1:1998

English language (18 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

Intertek Testing Services NA Inc.

Intertek certification services in North America.

ANAB United States Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Sponsored listings

Frequently Asked Questions

HD 21.13 S1:1995 is a standardization document published by CLC. Its full title is "Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 13: Oil resistant PVC sheathed cables with two or more conductors". This standard covers: This part (part 13) of the HD details the particular specifications for oil resistant polyvinyl chloride insulated and sheathed flexible cables, of rated voltage (Uo/U) up to and including 300/500 V, for a maximum conductor temperature in normal operation of 70ø C. All cables shall comply with the appropriate requirements given in Part 1 and the individual types of cable shall comply with the particular requirements of this Part. NOTE: The limits for the overall diameter of the cables have been calculated in accordance with EN 60719.

This part (part 13) of the HD details the particular specifications for oil resistant polyvinyl chloride insulated and sheathed flexible cables, of rated voltage (Uo/U) up to and including 300/500 V, for a maximum conductor temperature in normal operation of 70ø C. All cables shall comply with the appropriate requirements given in Part 1 and the individual types of cable shall comply with the particular requirements of this Part. NOTE: The limits for the overall diameter of the cables have been calculated in accordance with EN 60719.

HD 21.13 S1:1995 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables. The ICS classification helps identify the subject area and facilitates finding related standards.

HD 21.13 S1:1995 has the following relationships with other standards: It is inter standard links to EN 50525-2-51:2011, HD 21.13 S1:1995/A1:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

HD 21.13 S1:1995 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

HD 21.13 S1:1995 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-februar-1998
.DEOLVSROLYLQLONORULGQRL]RODFLMR]DQD]QDþHQHQDSHWRVWLGRYNOMXþQR9
GHO.DEOL]GYHPDDOLYHþYRGQLNLVSROLYLQLONORULGQLPSODãþHPRGSRUQLPSURWL
ROMX
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part
13: Oil resistant PVC sheathed cables with two or more conductors
Polyvinylchlorid-isolierte Leitungen mit Nennspannungen bis 450/750 V - Teil 13:
Ölbeständige PVC-Steuerleitungen mit zwei oder mehr Adern
Conducteurs et câbles isolés au polychlorure de vinyle, de tension assignée au plus
égale à 450/750 V - Partie 13: Câbles souples avec gaine de polychlorure de vinyle,
résistant à l'huile, à deux âmes ou plus
Ta slovenski standard je istoveten z: HD 21.13 S1:1995
ICS:
29.060.20 Kabli Cables
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

-----
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...