EN IEC 60695-1-14:2026 is a CENELEC standard from the International Electrotechnical Commission (IEC) that gives guidance on power and energy levels linked to ignition and fire in low voltage electrotechnical products. It helps Product Committees judge when an electrical energy source is unlikely to ignite materials, when a fire hazard safeguard should be used, and when extra protection against fire spread is needed.
What does EN IEC 60695-1-14:2026 specify?
EN IEC 60695-1-14:2026 provides guidance for low voltage electrotechnical products used in normal atmospheres commonly available in the home. It is intended for IEC technical committees and Product Committees when preparing or revising product standards for their own applications.
The scope focuses on electrical energy that may be dissipated as heat and used as a basis for fire hazard safeguards. It excludes special locations such as explosive atmospheres. The document is organized into scope, normative references, terms and definitions, electrical energy as a cause of ignition, empirical safety values of electrical power and energy, and a bibliography.
What are the key requirements of EN IEC 60695-1-14:2026?
EN IEC 60695-1-14:2026 is guidance rather than a product test standard. Its main message is that Product Committees should classify electrical energy sources by their ability to cause ignition and then decide what safeguards are appropriate for the product under consideration.
How should the classification be used?
Clause 5 says the classification can be applied to any part, circuit, or end product. The standard uses both power/time thinking and an alternative energy-based view, because the practical risk depends on how much energy is available and for how long. In practice, this helps a committee choose whether to rely on inherent limits, insulation, separation distance, or enclosure design.
What does Class 1 mean?
Clause 5.2 describes Class 1 as an electrical energy source considered unlikely to cause ignition under most circumstances. The practical takeaway is that a source below the stated low power level is normally treated as a safe energy level, so a fire hazard safeguard is usually not needed. The clause also notes that thermal insulation can change the picture, so the surrounding construction still matters.
What does Class 2 mean?
Clause 5.3 treats Class 2 as a source that may cause ignition under certain circumstances, so a fire hazard safeguard should be used. The standard links this to a controlled limit on available power and explains that practical safeguards are typically isolation and use of materials with suitable resistance to ignition. For a reader, this means the product may be allowed to have a potential ignition source, but nearby materials and layout must help contain the risk.
What does Class 3 mean?
Clause 5.4 treats Class 3 as a source likely to cause ignition and, if combustible material is present, fire spread. The document says a second fire hazard safeguard should be in place, such as a fire enclosure or a separation distance from nearby combustible material. In practice, this is the class where design must address not only ignition but also how fire is prevented from spreading.
How does the document help with power limits?
Clause 5 also gives practical guidance for low voltage installations, including the distinction between pluggable equipment type A, pluggable equipment type B, and permanently connected equipment. It uses the product of nominal mains voltage and overcurrent protective device rating to judge whether a circuit sits within the stated steady-state power level. That matters because the same equipment can fall into different design categories depending on how it is connected to the supply.
What terms does EN IEC 60695-1-14:2026 define?
- Fire hazard - a physical object or condition with the potential for an undesirable consequence from fire.
- Fire hazard safeguard - a part, system, or instruction intended to reduce ignition or fire spread; the document notes that this is often called a protection method.
- Ignition - the initiation of combustion.
- Low voltage equipment - electrical equipment with a supply or output voltage not exceeding 1 000 V AC or 1 500 V DC.
- Permanently connected equipment - equipment that can only be connected to or disconnected from the mains using a tool.
- Pluggable equipment type A - equipment intended for connection to the mains through a non-industrial plug and socket-outlet or appliance coupler.
- Pluggable equipment type B - equipment intended for connection to the mains through an industrial plug and socket-outlet or appliance coupler.
- Potential ignition source - a location where electrical energy can cause ignition.
Who uses EN IEC 60695-1-14:2026?
EN IEC 60695-1-14:2026 is aimed at IEC Product Committees and technical committees preparing product standards. It is also relevant to engineers working on low voltage electrotechnical products, especially where fire hazard safeguards have to be chosen during design.
The document is particularly useful in sectors covered by the referenced standards, including household appliances and audio/video, information and communication technology equipment. In those areas, the classification helps teams decide how much protection is needed around energized parts, wiring, and components.
Which standards are used with EN IEC 60695-1-14:2026?
- ISO/IEC Guide 51 - gives the general safety approach used when writing standards.
- ISO 13943:2017 - provides fire safety vocabulary used for the terms in this document.
- IEC GUIDE 104 - explains how to prepare and use basic safety publications.
- IEC GUIDE 116:2010 - gives guidance on safety-related risk assessment and risk reduction for low voltage equipment.
- IEC 60335-1:2020 - provides general safety requirements for household and similar electrical appliances.
- IEC 60695-1-10 and IEC 60695-1-11 - the companion parts used with this publication for fire hazard guidance and assessment.
- IEC 60695-4:2021 - supplies terminology for fire tests for electrotechnical products.
- IEC 60695-11-10:2013 - provides the 50 W flame test methods referenced in the rationale.
- IEC 62368-1:2023 - gives safety requirements for audio/video and ICT equipment, including related power source concepts.
What does the EN IEC 60695-1-14:2026 document contain?
Clause 4 explains how electrical energy can become a cause of ignition through arcing or resistive heating. It also discusses the factors that affect temperature rise, including material mass, heat capacity, heat loss, and geometry, and it notes that prediction can be complex.
Clause 5 sets out the empirical safety values used to classify power and energy sources into Classes 1, 2, and 3. The document includes Figure 1, which illustrates power/time limits, and Figure 2, which illustrates energy limits. These visuals support product design and fire hazard assessment by showing how the classifications are meant to be interpreted in practice.
Relations
- Effective Date
- 22-Nov-2026
- Effective Date
- 22-Nov-2026
- Effective Date
- 22-Nov-2026
- Effective Date
- 22-Nov-2026
- Effective Date
- 22-Nov-2026
- Effective Date
- 22-Nov-2026
- Effective Date
- 17-Nov-2026
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
EN IEC 60695-1-14:2026 is a draft published by CLC. Its full title is "Fire hazard testing - Part 1-14: Guidance on the different levels of power and energy related to the probability of ignition and fire in low voltage electrotechnical products". This standard covers: Fire hazard testing - Part 1-14: Guidance on the different levels of power and energy related to the probability of ignition and fire in low voltage electrotechnical products
Fire hazard testing - Part 1-14: Guidance on the different levels of power and energy related to the probability of ignition and fire in low voltage electrotechnical products
EN IEC 60695-1-14:2026 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.020 - Electrical engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN IEC 60695-1-14:2026 has the following relationships with other standards: It is inter standard links to EN ISO 13943:2017, EN 60695-1-10:2017, EN IEC 62368-1:2024, EN IEC 60695-4:2021, EN 60695-11-10:2013, EN 60695-1-11:2015, EN IEC 60335-1:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN IEC 60695-1-14:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 fire hazard
- 3.2 fire hazard safeguard
- 3.3 ignition
- 3.4 low voltage equipment
- 3.5 permanently connected equipment
- 3.6 pluggable equipment type A
- 3.7 pluggable equipment type B
- 3.8 potential ignition source
- 4 Electrical energy as a cause of ignition
- 5 Empirical safety values of electrical power and energy
- 5.1 Different levels of power and electrical energy sources
- 5.2 Electrical power and energy source that is unlikely to cause ignition (Class 1)
- 5.3 Electrical power and energy source that may cause ignition (Class 2)
- 5.4 Electrical power and energy source that is likely to cause ignition (Class 3)
- 5.5 Graphical overview of the classification
- Bibliography
INTRODUCTION In the design of any electrotechnical product the risk of fire and the potential hazards associated with fire need to be considered. In this respect the objective of component, circuit and equipment design, as well as the choice of materials, is to reduce the risk of fire to a tolerable level even in the event of reasonably foreseeable (mis)use, malfunction or failure. IEC 60695‑1‑10 [1], IEC 60695‑1‑11 [2] and IEC 60695-1-12 [3] provide guidance on how this is to be accomplished.
Fires involving electrotechnical products can be initiated from external non-electrical sources. Considerations of this nature are dealt with in an overall fire hazard (3.1) assessment. The aim of the IEC 60695 series of standards is to save lives and property by reducing the number of fires or reducing the consequences of the fire. This can be accomplished by trying to:
- prevent ignition (3.3) caused by an electrically energised component part and, in the event of ignition (3.3), to confine any resulting fire within the bounds of the enclosure of the electrotechnical product;
- minimize flame spread beyond the product’s enclosure and to minimise the harmful effects of fire effluents including heat, smoke, and toxic or corrosive combustion products. This standard provides guidance to Product Committees on the power levels and amounts of energy that are likely to cause ignition (3.3) and fire. It also provides guidance to Product Committees on the fire hazard safeguards (3.2) that might be necessary to protect against the probability of ignition (3.3).
The probability of fire is highly dependent on the specific fire scenario within the electrotechnical product itself. Therefore, product committees are ultimately responsible for deciding what fire hazard safeguards (3.2) are appropriate for their products.
This standard was created due to a need (IEC technical committee 66) for guidance on electrical energy levels in relation to ignition (3.3) and fire. The preparation of this standard is based on electrical energy levels developed by TC 108, responsible for safety of audio, video and ICT equipment.
oSIST prEN IEC 60695-1-14:2025
1 Scope
This part of IEC 60695 provides guidance about the levels of power and energy that could cause ignition (3.3) and fire in a low voltage electrotechnical product. It can be used by Product Committees to determine what fire hazard safeguards (3.2) might be used, based on the electrical energy that could be dissipated as heat.
This document deals with products used in normal atmospheres commonly available in the home and does not deal with special locations such as those in explosive atmospheres. It is intended as guidance to IEC committees, and is intended be used with respect to their individual applications.
This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC GUIDE 104 and ISO/IEC Guide 51 .
One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
ISO/IEC Guide 51, Safety aspects — Guidelines for their inclusion in standards ISO 13943:2017, Fire safety — Vocabulary IEC GUIDE 104, The preparation of safety publications and the use of basic safety publications and group safety publications IEC GUIDE 116:2010, Guidelines for safety related risk assessment and risk reduction for low voltage equipment IEC 60335-1:2020, Household and similar electrical appliances - Safety - Part 1: General requirements IEC 60695-1-10, Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines IEC 60695-1-11, Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment IEC 60695-4:2021, Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products IEC 60695-11-10:2013, Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods IEC 62368-1:2023, Audio/video, information and communication technology equipment - Part 1: Safety requirements
oSIST prEN IEC 60695-1-14:2025
The preparation of safety publications and the use of basic safety publications and group safety publications
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60695-4:2021 and ISO 13943:2017 (some of which are reproduced below) and the following apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:
- IEC Electropedia: available at http://www.electropedia.org/
- ISO Online browsing platform: available at http://www.iso.org/obp
3.1 fire hazard
physical object or condition with a potential for an undesirable consequence from fire [SOURCE: ISO 13943:2017, 3.131]
3.2 fire hazard safeguard
part or system or instruction specifically provided to reduce the likelihood of ignition (3.3) or spread of fire Note 1 to entry: A fire hazard safeguard (3.2) is often also called a protection method. Note 2 to entry: Examples include current limiters, distances to or from ignition (3.3) sources, materials with flame retardant properties.
3.3 ignition
initiation of combustion [SOURCE: ISO 13943:2017, 3.217]
3.4 low voltage equipment
set of electrical devices or electrical equipment necessary to perform a specific task such as generation, transmission, distribution, utilisation of electric energy and with a supply or output voltage not exceeding 1 000 V for alternating current and 1 500 V for direct current Note 1 to entry: Examples of low voltage equipment are electric power generator, electrical switchgear and control - gear assemblies, electrical wiring systems, air conditioning units. [SOURCE: IEC GUIDE 116:2010,3.1]
3.5 permanently connected equipment
equipment that can only be electrically connected to or disconnected from the mains by the use of a tool [SOURCE: IEC 62368-1:2023, 3.3.3.6]
3.6 pluggable equipment type A
equipment that is intended for connection to the mains via a non-industrial plug and socketoutlet or via a non-industrial appliance coupler, or both
oSIST prEN IEC 60695-1-14:2025
Note 1 to entry: Examples are plugs and socket-outlets covered by standards such asIEC TR 60083 [4] andIEC 60320-1 [5].
[SOURCE: IEC 62368-1:2023, 3.3.3.7]
3.7 pluggable equipment type B
equipment that is intended for connection to the mains via an industrial plug and socket -outlet or via an industrial appliance coupler, or both Note 1 to entry: Examples are plugs and socket-outlets covered by standards such asIEC 60309‑1 [8]. [SOURCE: IEC 62368-1:2023, 3.3.3.8]
3.8 potential ignition source
location where electrical energy can cause ignition (3.3) [SOURCE: IEC 62368-1:2023, 3.3.9.1]
...