EN IEC 60335-2-76:2018
(Main)Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers
Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers
This part of IEC 60335 deals with the safety of electric fence energizers, the rated voltage of which is not more than 250 V and by means of which fence wires in agricultural, domestic or feral animal control fences and security fences may be electrified or monitored. NOTE 101 Examples of electric fence energizers coming within the scope of this standard are: - mains-operated energizers; - battery-operated electric fence energizers suitable for connection to the mains, as shown in Figure 101 and Figure 102; - electric fence energizers operated by non-rechargeable batteries either incorporated or separate. This standard does not in general take into account - the use of appliances by young children or infirm persons without supervision; - the playing with appliances by young children. NOTE 102 Attention is drawn to the fact that - for appliances intended to be used on board ships or aircraft, additional requirements can be necessary; - in many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities. NOTE 103 This standard does not apply to - electromagnetically coupled animal trainer collars; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); - separate battery chargers (IEC 60335-2-29); - electric fishing machines (IEC 60335-2-86); - electric animal-stunning equipment (IEC 60335-2-87); - appliances for medical purposes (IEC 60601)
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke – Teil 2-76: Besondere Anforderungen für Elektrozaungeräte
Appareils électrodomestiques et analogues - Sécurité - Partie 2-76: Exigences particulières pour les électrificateurs de clôtures
Gospodinjski in podobni električni aparati - Varnost - 2-76. del: Posebne zahteve za generatorje impulzov za električne ograje
Ta del standarda IEC 60335 obravnava varnost generatorjev impulzov za električne ograje, katerih nazivna napetost ne presega 250 V in s pomočjo katerih so lahko žice ograje v kmetijskih ograjah, ograjah za odganjanje domačih ali divjih živali in varnostnih ograjah elektrificirane ali nadzorovane.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2018
1DGRPHãþD
SIST EN 60335-2-76:2005
SIST EN 60335-2-76:2005/A1:2006
SIST EN 60335-2-76:2005/A11:2008
SIST EN 60335-2-76:2005/A12:2011
SIST EN 60335-2-76:2005/A2:2015
*RVSRGLQMVNLLQSRGREQLHOHNWULþQLDSDUDWL9DUQRVWGHO3RVHEQH]DKWHYH
]DJHQHUDWRUMHLPSXO]RY]DHOHNWULþQHRJUDMH
Household and similar electrical appliances - Safety - Part 2-76: Particular requirements
for electric fence energizers
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke – Teil 2-76:
Besondere Anforderungen für Elektrozaungeräte
Appareils électrodomestiques et analogues - Sécurité - Partie 2-76: Exigences
particulières pour les électrificateurs de clôtures
Ta slovenski standard je istoveten z: EN IEC 60335-2-76:2018
ICS:
65.040.10 Poslopja, naprave in oprema Livestock buildings,
za živino installations and equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN IEC 60335-2-76
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2018
ICS 65.040.99 Supersedes EN 60335-2-76:2005,
EN 60335-2-76:2005/A1:2006,
EN 60335-2-76:2005:A11:2008,
EN 60335-2-76:2005/A12:2010 and
EN 60335-2-76:2005/A2:2015
English Version
Household and similar electrical appliances - Safety - Part 2-76:
Particular requirements for electric fence energizers
(IEC 60335-2-76:2018)
Appareils électrodomestiques et analogues - Sécurité - Sicherheit elektrischer Geräte für den Hausgebrauch und
Partie 2-76: Exigences particulières pour les électrificateurs ähnliche Zwecke - Teil 2-76: Besondere Anforderungen für
de clôtures Elektrozaungeräte
(IEC 60335-2-76:2018) (IEC 60335-2-76:2018)
This European Standard was approved by CENELEC on 2018-08-03. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60335-2-76:2018 E
European foreword
The text of document 61H/366/FDIS, future edition 3 of IEC 60335-2-76, prepared by SC 61H "Safety
of electrically-operated farm appliances" of IEC/TC 61 "Safety of household and similar electrical
appliances" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2019-05-03
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2021-08-03
document have to be withdrawn
This document supersedes EN 60335-2-76:2005, EN 60335-2-76:2005/A1:2006,
EN 60335-2-76:2005:A11:2008, EN 60335-2-76:2005/A12:2010 and EN 60335-2-76:2005/A2:2015.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 60335-2-76:2018 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 60335-2-86 NOTE Harmonized as EN 60335-2-86
IEC 60335-2-87 NOTE Harmonized as EN 60335-2-87
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
Environmental testing – Part 2: Tests –
IEC 60068-2-52 2017 EN IEC 60068-2-52 2018
Test Kb: Salt mist, cyclic (sodium chloride
solution)
IEC 60320-3 - Appliance couplers for household and EN 60320-3 -
similar general purposes - Part 3: Standard
sheets and gauges
ISO 3864-1 - Graphical symbols - Safety colours and - -
safety signs - Part 1: Design principles for
safety signs and safety markings
IEC 60335-2-76 ®
Edition 3.0 2018-06
INTERNATIONAL
STANDARD
colour
inside
Household and similar electrical appliances – Safety –
Part 2-76: Particular requirements for electric fence energizers
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 65.040.99 ISBN 978-2-8322-5808-8
– 2 – IEC 60335-2-76:2018 © IEC 2018
CONTENTS
FOREWORD . 4
INTRODUCTION . 7
1 Scope . 8
2 Normative references. 8
3 Terms and definitions . 9
4 General requirement . 13
5 General conditions for the tests . 13
6 Classification . 14
7 Marking and instructions . 15
8 Protection against access to live parts . 18
9 Starting of motor-operated appliances . 18
10 Power input and current . 18
11 Heating . 18
12 Void . 20
13 Leakage current and electric strength at operating temperature . 20
14 Transient overvoltages. 21
15 Moisture resistance . 22
16 Leakage current and electric strength . 22
17 Overload protection of transformers and associated circuits . 23
18 Endurance . 23
19 Abnormal operation . 24
20 Stability and mechanical hazards . 26
21 Mechanical strength . 26
22 Construction . 27
23 Internal wiring . 31
24 Components . 32
25 Supply connection and external flexible cords . 32
26 Terminals for external conductors . 32
27 Provision for earthing . 33
28 Screws and connections . 33
29 Clearances, creepage distances and solid insulation . 33
30 Resistance to heat and fire . 33
31 Resistance to rusting . 34
32 Radiation, toxicity and similar hazards . 34
Annexes . 40
Annex A (informative) Routine tests . 40
Annex B (normative) Appliances powered by rechargeable batteries that are
recharged in the appliance . 41
Annex S (normative) Battery-operated appliances powered by batteries that are non-
rechargeable or not recharged in the appliance . 43
Annex AA (informative) Circuit for the independent control of the switching speed of
the major impulse-switching device . 47
IEC 60335-2-76:2018 © IEC 2018 – 3 –
Annex BB (normative) Instructions for installation and connection of electric fences . 48
BB.1 Instructions for electric animal fences . 48
BB.2 Instructions for electric security fences not supplied from a security
energizer group . 50
BB.3 Instructions for electric security fences supplied from a security energizer
group . 52
Annex CC (informative) Installation of electric security fences . 56
CC.1 General . 56
CC.2 Location of electric security fence . 56
CC.3 Prohibited zone for pulsed conductors . 56
CC.4 Separation between electric fence and physical barrier . 56
CC.5 Prohibited mounting . 57
CC.6 Operation of electric security fence . 57
Bibliography . 60
Figure 101 – Schematic examples of type A energizers, type B energizers
and type C energizers . 35
Figure 102 – Schematic examples of the different types of type D energizers . 36
Figure 103 – Current limited energizer characteristic limit line . 37
Figure 104 – Type R security energizer group test configurations . 38
Figure 105 – Type S security energizer group test configurations . 39
Figure AA.1 – Circuit for the independent control of the switching speed of the major
impulse-switching device . 47
Figure BB.1 – Symbol for warning sign . 55
Figure CC.1 – Prohibited area for pulse conductors . 57
Figure CC.2 – Typical constructions where an electric security fence is exposed
to the public . 58
Figure CC.3 – Typical fence constructions where the electric security fence is installed
in windows and skylights . 59
Table 101 – Battery source impedance . 19
Table 102 – Rated supply voltage maximum and minimum value multiplier factors . 19
Table 103 – Supply voltage value test settings . 20
Table 104 – Test supply sequence for different supply type . 20
Table 105 – Additional test voltages . 23
Table BB.1 – Minimum clearances from power lines for electric animal fences . 49
Table BB.2 – Minimum clearances from power lines for electric security fences not
supplied from a security energizer group . 51
Table BB.3 – Minimum clearances from power lines for electric security fences
supplied from a security energizer group . 54
– 4 – IEC 60335-2-76:2018 © IEC 2018
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES – SAFETY –
Part 2-76: Particular requirements for electric fence energizers
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This part of International Standard IEC 60335 has been prepared by subcommittee 61H:
Safety of electrically-operated farm appliances, of IEC technical committee 61: Safety of
household and similar electrical appliances.
This third edition cancels and replaces the second edition published in 2002,
Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
• the text has been aligned with Edition 5.2 of Part 1;
• additional requirements for security fence energizers have been introduced (Clauses 3, 7,
19, 22, Figures and Annex BB);
• specific requirements for battery operated energizers have been moved to Annex S.
IEC 60335-2-76:2018 © IEC 2018 – 5 –
The text of this International Standard is based on the following documents:
FDIS Report on voting
61H/366/FDIS 61H/367/RVD
Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 60335 series, published under the general title Household and
similar electrical appliances – Safety, can be found on the IEC website.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments. It was established on the basis of the fifth edition (2010) of that standard.
NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1.
This Part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to
convert that publication into the IEC standard: Safety requirements for electric fence
energizers.
When a particular subclause of Part 1 is not mentioned in this Part 2, that subclause applies
as far as is reasonable. When this standard states “addition”, “modification” or “replacement”,
the relevant text in Part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional Annexes are lettered AA, BB, etc.
NOTE 3 The following print types are used:
– requirements: in roman type
– test specifications: in italic type
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and
associated noun are also in bold.
NOTE 4 The attention of National Committees is drawn to the fact that equipment manufacturers and testing
organizations may need a transitional period following publication of a new, amended or revised IEC publication in
which to make products in accordance with the new requirements and to equip themselves for conducting new or
revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation
nationally not earlier than 12 months or later than 36 months from the date of publication.
The following differences exist in the countries indicated below:
6.101: Only energy limited energizers are allowed (All EU and EFTA counties).
– 6 – IEC 60335-2-76:2018 © IEC 2018
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
IEC 60335-2-76:2018 © IEC 2018 – 7 –
INTRODUCTION
It has been assumed in the drafting of this International Standard that the execution of its
provisions is entrusted to appropriately qualified and experienced persons.
This standard recognizes the internationally accepted level of protection against hazards such
as electrical, mechanical, thermal, fire and radiation of appliances when operated as in
normal use taking into account the manufacturer's instructions. It also covers abnormal
situations that can be expected in practice and takes into account the way in which
electromagnetic phenomena can affect the safe operation of appliances.
This standard takes into account the requirements of IEC 60364 as far as possible so that
there is compatibility with the wiring rules when the appliance is connected to the supply
mains. However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered
by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as
far as is reasonable. If applicable, the influence of one function on the other is taken into
account.
NOTE 1 Throughout this publication, when “Part 1” is mentioned, it refers to IEC 60335-1.
When a part 2 standard does not include additional requirements to cover hazards dealt with
in Part 1, Part 1 applies.
NOTE 2 This means that the technical committees responsible for the part 2 standards have determined that it is
not necessary to specify particular requirements for the appliance in question over and above the general
requirements.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
NOTE 3 Horizontal and generic standards covering a hazard are not applicable since they have been taken into
consideration when developing the general and particular requirements for the IEC 60335 series of standards. For
example, in the case of temperature requirements for surfaces on many appliances, generic standards, such as
ISO 13732-1 for hot surfaces, are not applicable in addition to Part 1 or part 2 standards.
– 8 – IEC 60335-2-76:2018 © IEC 2018
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES – SAFETY –
Part 2-76: Particular requirements for electric fence energizers
1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electric fence energizers, the rated voltage
of which is not more than 250 V and by means of which fence wires in agricultural, domestic
or feral animal control fences and security fences may be electrified or monitored.
NOTE 101 Examples of electric fence energizers coming within the scope of this standard are:
– mains-operated energizers;
– battery-operated electric fence energizers suitable for connection to the mains, as shown in Figure 101
and Figure 102;
– electric fence energizers operated by non-rechargeable batteries either incorporated or separate.
This standard does not in general take into account
– the use of appliances by young children or infirm persons without supervision;
– the playing with appliances by young children.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified by the national health authorities, the national
authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
NOTE 103 This standard does not apply to
– electromagnetically coupled animal trainer collars;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a
corrosive or explosive atmosphere (dust, vapour or gas);
– separate battery chargers (IEC 60335-2-29);
– electric fishing machines (IEC 60335-2-86);
– electric animal-stunning equipment (IEC 60335-2-87);
– appliances for medical purposes (IEC 60601).
2 Normative references
This clause of Part 1 is applicable except as follows.
Addition:
IEC 60068-2-52:2017, Environmental testing – Part 2: Tests – Test Kb: Salt mist, cyclic
(sodium chloride solution)
IEC 60320-3, Appliance couplers for household and similar general purposes – Part 3:
Standard sheets and gauges
ISO 3864-1, Graphical symbols – Safety colours and safety signs – Part 1: Design principles
for safety signs and safety markings
IEC 60335-2-76:2018 © IEC 2018 – 9 –
3 Terms and definitions
This clause of Part 1 is applicable except as follows.
3.1 Definitions relating to physical characteristics
3.1.1 Addition:
Note 1 to entry: For type D energizers, the rated voltage of the energizer is the rated voltage for battery
supply.
Replacement:
3.1.9
normal operation
operation of the appliance under the following conditions: the electric fence energizer is
operated as in normal use when connected to the supply, with no load connected to the
output terminals
3.1.101
prospective peak voltage
peak output voltage of the impulse generator specified in Clause 14 that would be obtained
with the energizer not connected to the test circuit
3.1.102
rated voltage for battery supply
voltage for battery supply, for type A energizers, type B energizers, type C energizers and
type D energizers assigned to the energizer by the manufacturer
3.1.103
rated voltage range for battery supply
voltage range for battery supply, for type A energizers, type B energizers, type C
energizers and type D energizers assigned to the energizer by the manufacturer, expressed
by its lower and upper limits
3.1.104
impulse duration
duration of that part of the impulse that contains 95 % of the overall energy and is the shortest
2 2
interval of integration of I (t) that gives 95 % of the integration of I (t) over the total impulse
Note 1 to entry: I(t) is the impulse current as a function of time.
3.1.105
output current
RMS value of the output current per impulse calculated over the impulse duration
3.5 Definitions relating to types of appliances
3.5.101
electric fence energizer
appliance that is intended to deliver periodically voltage impulses to a fence connected to it
Note 1 to entry: Electric fence energizers are hereinafter also referred to as energizers.
3.5.102
mains-operated energizer
energizer designed for direct connection to the mains
– 10 – IEC 60335-2-76:2018 © IEC 2018
3.5.103
battery-operated energizer suitable for connection to the mains
energizer
– operated by batteries and having, or being designed for connection to, facilities for
charging these batteries from the mains, or
– designed for operation from the mains and from batteries
3.5.104
type A energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit, a battery charging circuit and a battery, the impulse generating circuit
being connected to the mains or the battery when the energizer is in operation
Note 1 to entry: Type A energizers are shown schematically in Figure 101.
3.5.105
type B energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit, a battery charging circuit and a battery, the impulse generating circuit
being connected to the battery and disconnected from the battery charging circuit and the
mains when the energizer is in operation.
Note 1 to entry: For recharging the battery, the impulse generating circuit is disconnected and rendered
inoperable.
Note 2 to entry: Type B energizers are shown schematically in Figure 101.
3.5.106
type C energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit and a battery, the impulse generating circuit being connected to the mains
or the battery when the energizer is in operation, and where it is necessary to remove the
battery to recharge it using a battery charger or, in the case of a non-rechargeable battery, to
replace it with a new battery
Note 1 to entry: Type C energizers are shown schematically in Figure 101.
3.5.107
type D energizer
battery-operated energizer suitable for connection to the mains consisting of an impulse
generating circuit intended to be powered by a battery, or a detachable supply unit, when
the energizer is in operation. The impulse generating circuit or the battery may be connected
to a detachable supply unit with or without incorporated battery charging circuitry for
recharging the battery when the energizer is in operation.
Note 1 to entry: Examples of Type D energizers are shown schematically in Figure 102.
3.5.108
battery-operated energizer
energizer deriving its energy solely from batteries or other sources of energy and not
designed for connection to the mains
3.5.109
security electric fence energizer
energizer containing fence circuits that are intended to periodically deliver voltage impulses
into electric security fences
Note 1 to entry: A security electric fence energizer is hereinafter also referred to as a security energizer.
IEC 60335-2-76:2018 © IEC 2018 – 11 –
3.5.110
independently timed security energizer
security energizer that includes an internal impulse timing signal source to set the timing
of the periodic voltage impulses it delivers to an electric security fence
Note 1 to entry: An independently timed security energizer is hereinafter also referred to as an independent
security energizer.
3.5.111
dependently timed security energizer
security energizer that is dependent on an external impulse timing signal to set the timing
of the periodic voltage impulses it delivers to an electric security fence
Note 1 to entry: A dependently timed security energizer is hereinafter also referred to as dependent security
energizer.
Note 2 to entry: Some types of security energizer may be configured either as an independent security
energizer or a dependent security energizer at the time of installation.
3.5.112
security energizer group
one or two security energizers with a group total of two fence circuits used to supply
adjacent electric security fences in a security energizer fence system that allows the two
fence circuits to be contacted at the same time
Note 1 to entry: The fence circuits in a security energizer group may be galvanically connected.
3.5.113
type R security energizer
security energizer with one or two fence circuits that is suitable for use in a type R
security energizer group
3.5.114
type R security energizer group
security energizer group containing only type R security energizers
3.5.115
type S security energizer
security energizer with one or two fence circuits that is suitable for use in a type S
security energizer group
3.5.116
type S security energizer group
security energizer group containing at least one type S security energizer
Note 1 to entry: A type S security energizer group may contain a type R security energizer.
3.6 Definitions relating to parts of an appliance
3.6.3 Addition:
Note 101 to entry: It also includes terminals for the connection of the battery and other metal parts in a battery
compartment that become accessible when replacing batteries even with the aid of a tool.
Replacement:
3.6.4
live part
conductive part that may cause an electric shock
– 12 – IEC 60335-2-76:2018 © IEC 2018
3.6.101
fence circuit
all conductive parts or components within an energizer, that are connected or intended to be
connected galvanically to the output terminals
3.6.102
security energizer impulse timing signal
signal that is used to determine the timing of the periodic voltage impulses delivered by a
security energizer to an electric security fence
Note 1 to entry: A security energizer impulse timing signal is hereinafter also referred to as an impulse timing
signal.
Note 2 to entry: Examples of a security energizer impulse timing signal include wired (RS-485), wired with
latency (internet clock, secure TCP/IP), wireless with latency (LAN, PAN), optical, GPS.
3.6.103
impulse timing signal source
signal source that generates the impulse timing signal required by a dependent security
energizer to set the timing of the periodic voltage impulses it delivers to an electric security
fence
Note 1 to entry: An impulse timing signal source may be used by one or more dependent security energisers.
Note 2 to entry: An example of an impulse timing signal source is an impulse signal from an adjacent electric
security fence that is powered by an independent security energizer that belongs to the same security
energizer fence system.
Note 3 to entry: An impulse signal from an adjacent electric security fence powered by an independent
security energizer not belonging to the same security energizer fence system is not an example of a possible
impulse timing signal source.
3.8 Definitions relating to miscellaneous matters
3.8.101
standard load
load consisting of a non-inductive resistor of 500 Ω ± 2,5 Ω and a variable resistor that is
adjusted so as to maximize the energy per impulse or output current in the 500 Ω resistor,
as applicable
Note 1 to entry: The variable resistor is connected in series or parallel with the 500 Ω resistor, whichever gives
the more unfavourable result.
3.8.102
earth electrode
metal structure that is driven into the ground near an energizer and connected electrically to
the output earth terminal of the energizer, and that is independent of other earthing
arrangements
3.8.103
pulsed conductors
conductors that are subjected to high voltage pulses by the energizer
3.8.104
connecting lead
electric conductor, used to connect the energizer to the electric fence or the earth electrode
3.8.105
fence
barrier for animals or for security purposes, comprising one or more conductors, such as
metal wires, rods or rails
IEC 60335-2-76:2018 © IEC 2018 – 13 –
3.8.106
electric fence
barrier that includes one or more electric conductors, insulated from earth, to which electric
pulses are applied by an energizer
3.8.107
electric animal fence
electric fence used to contain animals within or exclude animals from a particular area
3.8.108
electric security fence
fence used for security purposes that comprises an electric fence and a physical barrier
electrically isolated from the electric fence
3.8.109
physical barrier
barrier not less than 1,5 m high intended to prevent inadvertent contact with the pulsed
conductors of the electric fence
Note 1 to entry: Physical barriers are typically constructed from vertical sheeting, rigid vertical bars, rigid mesh,
rods or chain-wire mesh.
3.8.110
public access area
any area where persons are protected from inadvertent contact with pulsed conductors by
a physical barrier
3.8.111
secure area
area where a person is not separated from pulsed conductors below 1,5 m by a physical
barrier
3.8.112
security energizer fence system
electric security fence installation where the fences are energized by one or more security
energizers containing one or more security energizer groups that can be type R security
energizer groups or type S security energizers groups
Note 1 to entry: An independent impulse timing signal source used in a security energizer fence system may
be used to set the timing of dependent security energizers in multiple security energizer groups.
4 General requirement
This clause of Part 1 is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable except as follows.
5.2 Modification:
Replace the test specification by the following:
The tests are made on two energizers as delivered, one being subjected to all the tests with
the exception of that of Clause 18, and the other to the tests of 22.108 and Clause 18.
However, the tests of Clauses 22 to 28 may be made on separate samples.
– 14 – IEC 60335-2-76:2018 © IEC 2018
For type A energizers and type C energizers, an additional sample is required for the test of
Clause 18.
Addition:
NOTE 101 Where electronic circuits, electronic components or other devices are normally encapsulated,
specially prepared samples can be used for the tests of 19.11 and 19.101.
5.3 Addition:
The measurements of 22.108 shall be carried out before the tests of Clause 14.
If any electronic component has been damaged during the tests of Clause 14, the tests of
Clause 19 are made twice, once before and once after the damaged electronic components
have been replaced by new electronic components.
5.5 Addition:
The energizer is mounted in a normal position such that the deviation from the position for
which it is designed does not exceed 15°. However, if the energizer is provided with means
for adjustment to the normal position, such as a spirit level, the energizer shall be adjusted to
within ±2° of the normal position.
The earthing terminal of the fence circuit is connected to earth. However, if there is no
indication as to which of the output terminals is to be connected to earth, the terminal that
gives the most unfavourable result is earthed.
5.8.1 Addition:
For type A energizers, type B energizers, type C energizers and type D energizers where
the terminals for the connection of the battery have no indication of polarity, the more
unfavourable polarity of the voltage source replacing the battery shall be applied.
For mains-operated energizers and battery-operated energizers suitable for connection
to the mains, the reference source impedance of the mains supply shall be 0,4 Ω + j0,25 Ω.
5.101 All energizers are tested as motor-operated appliances.
6 Classification
This clause of Part 1 is applicable except as follows.
6.1 Replacement:
Mains-operated energizers and battery-operated energizers suitable for connection to
the mains shall be class II with respect to protection against electric shock.
Compliance is checked by inspection and by the relevant tests.
6.2 Addition:
Energizers shall be of at least IPX4.
6.101 Energizers are classified as being either energy limited energizers or current
limited energizers.
Compliance is checked by the appropriate tests.
IEC 60335-2-76:2018 © IEC 2018 – 15 –
7 Marking and instructions
This clause of Part 1 is applicable except as follows.
7.1 Addition:
Type A energizers, type B energizers and type C energizers shall be marked with the
rated voltage for battery supply or rated voltage range for battery supply, in volts.
Energy limited energizers that are marked with a maximum energy/impulse exceeding 5 J
shall also be marked with the corresponding load resistance at which maximum
energy/impulse is obtained.
Energizers shall be marked with symbol ISO 7000-0790 (2004-01).
Type R security energizers shall be marked with symbol IEC 60417-6406 (2018-02).
Type S security energizers shall be marked with symbol IEC 60417-6407 (2018-02).
7.6 Addition:
[symbol IEC 60417-5036
dangerous voltage
(2002-10)]
[symbol IEC 60417-5017
earth; ground
(2006-08)]
[symbol IEC 60417-6406
time synchronized type R security energizer
(2018-02)]
[symbol IEC 60417-6407
time synchronized type S security energizer
(2018-02)]
The symbols for output (fence) and output (earth) shall be in accordance with symbols
IEC 60417-5036 (2002-10) and IEC 60417-5017 (2006-08) respectively.
7.12 Addition:
Instructions for battery-operated energizers suitable for connection to the mains shall
– include a warning against using non-rechargeable batteries while the e
...