Radio-frequency connectors - Part 51: Sectional specification for RF coaxial connectors with inner diameter of outer conductors 13,5 mm with bayonet lock - Characteristic impedance 50 Ohm (type QLI)

IEC 61169-51:2015 provides information and rules for the preparation of detail specifications (DS) for type QLI R.F. coaxial connectors with quick lock. The connectors are normally used with 50 Ohms corrugated cable and flexible cables for middle power applications in an operating range up to 6 GHz. It describes the interface dimensions for general purpose connectors with gauging information and the mandatory tests selected from IEC 61169-1 applicable to all detail specifications relative to type QLI connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements.

Hochfrequenz-Steckverbinder - Teil 51: Rahmenspezifikation für koaxiale HF Steckverbinder mit 13,5 mm Innendurchmesser des Außenleiters und Bajonettverschluss - Wellenwiderstand 50 Ohm (Typ QLI)

Connecteurs pour fréquences radioélectriques - Partie 51: Spécification intermédiaire relative aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs de 13,5 mm à verrouillage à baïonnette – Impédance caractéristique 50 Ohm (type QLI)

L'IEC 61169-51:2015 fournit des informations et des règles en vue de l'établissement de spécifications particulières (SP) relatives aux connecteurs coaxiaux pour fréquences radioélectriques de type QLI à verrouillage rapide. Les connecteurs sont normalement utilisés avec des câbles 50 Ohms annelés et des câbles souples pour des applications en moyenne puissance au sein d'une plage de fonctionnement inférieure ou égale à 6 GHz. Elle décrit les dimensions d'interface pour des connecteurs d'usage général, ainsi que des informations concernant les calibres et les essais obligatoires choisis dans l'IEC 61169-1, applicables à toutes les spécifications particulières ayant trait aux connecteurs de type QLI. La présente spécification indique les caractéristiques de performance recommandées à prendre en compte pour la rédaction d'une SP et elle couvre tous les programmes d'essais et les exigences de contrôle.

Radiofrekvenčni konektorji - 51. del: Področne specifikacije za radiofrekvenčne koaksialne konektorje z notranjim premerom zunanjih vodnikov 13,5 mm in bajonetnim zaklepom - Karakteristična impedanca 50 Ohm (tip QLI) (IEC 61169-51:2015)

Ta del standarda IEC 61169, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobnih specifikacij (DS) za radiofrekvenčne koaksialne konektorje vrste QLI z zaklepanjem. Konektorji se običajno uporabljajo s 50-ohmskim valovitim kablom in prožnimi kabli za srednjemočnostne uporabe v območju delovanja do 6 GHz. Opisuje dimenzije vmesnika za konektorje za splošni namen z informacijami o merjenju in obvezne preskuse, izbrane iz standarda IEC 61169-1, ki se uporabljajo za vse podrobne specifikacije v zvezi s konektorji tipa QLI.
Ta specifikacija določa priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobnih specifikacij, ter zajema vse urnike preskusov in zahteve za pregled.
OPOMBA: Izvirne mere so podane v metričnih merah. Vse nedimenzionirane slikovne konfiguracije so podane samo v referenčne namene.

General Information

Status
Published
Publication Date
21-May-2015
Withdrawal Date
11-Mar-2018
Current Stage
6060 - Document made available - Publishing
Start Date
22-May-2015
Completion Date
22-May-2015

Overview

EN 61169-51:2015 (IEC 61169-51:2015) is the sectional specification for RF coaxial connectors type QLI - bayonet-lock connectors with an inner diameter of outer conductors of 13.5 mm and characteristic impedance 50 Ω. The document gives rules and templates for preparing Detail Specifications (DS) for QLI connectors, defines interface dimensions and gauging, and sets out the mandatory and recommended test schedules, inspection and quality assessment requirements for use with 50 Ω corrugated and flexible cables in middle‑power RF applications (operating range up to 6 GHz).

Key topics and requirements

  • Connector geometry and mating faces: dimensional drawings and tolerances for both socket‑centre and pin‑centre contact variants, including bayonet lock details and gauging information.
  • Gauging and verification: gauge pin and gauge ring requirements and test procedures to ensure interchangeability and correct mating.
  • Performance characteristics and ratings: recommended electrical, mechanical and environmental characteristics to be included when writing a DS (see tables for ratings and acceptance criteria).
  • Test schedules and inspection: mandatory acceptance tests and recommended periodic tests, with severities and conditions selected from IEC 61169‑1 (generic requirements).
  • Quality assessment & qualification: rules for supplier qualification approval, quality conformance inspection, periodic testing and maintenance of qualification.
  • Detail Specification guidance: instructions, marking, ordering information and a blank DS pro‑forma to help manufacturers and procurers create compliant product specifications.
  • Regulatory/patent note: the introduction flags potential patent claims related to the connector design (holder contact details included in the standard).

Applications and users

EN 61169‑51:2015 is practical for:

  • Connector manufacturers creating QLI products and writing Detail Specifications (DS).
  • Cable assembly producers using 50 Ω corrugated or flexible cables for middle‑power RF links.
  • Test laboratories and inspectors performing dimensional gauging, electrical/mechanical testing and qualification.
  • System integrators, procurement and R&D teams in telecom, broadcast, satellite ground stations, microwave links, and industrial RF systems that require interoperable, bayonet‑lock 50 Ω connectors up to 6 GHz.

Related standards

  • IEC/EN 61169‑1 - Generic specification: general requirements and measuring methods (normative reference).
  • IEC 60529 - Degrees of protection (IP Code).
  • IEC 62037 series - Passive RF and microwave intermodulation measurement.
  • ISO 21207 - Corrosion/accelerated corrosion testing.

Keywords: EN 61169-51:2015, IEC 61169-51, RF coaxial connectors, QLI, 50 Ohm, bayonet lock, connector dimensions, gauging, test schedules, quality assessment, up to 6 GHz.

Standard
EN 61169-51:2015
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2015
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQHVSHFLILNDFLMH]DUDGLRIUHNYHQþQH
NRDNVLDOQHNRQHNWRUMH]QRWUDQMLPSUHPHURP]XQDQMLKYRGQLNRYPPLQ
EDMRQHWQLP]DNOHSRP.DUDNWHULVWLþQDLPSHGDQFD2KP WLS4/,  ,(&

Radio-frequency connectors - Part 51: Sectional specifications RF coaxial connectors
with inner diameter of outer conductors 13.5 mm with bayonet lock. Characteristics
impedance 50 Ohm (type QLI) (IEC 61169-51:2015)
Hochfrequenz-Steckverbinder - Teil 51: Rahmenspezifikation für koaxiale HF
Steckverbinder mit 13,5 mm Innendurchmesser des Außenleiters und Bajonettverschluss
- Wellenwiderstand 50 Ohm (Typ QLI) (IEC 61169-51:2015)
Connecteurs pour fréquences radioélectriques - Partie 51: Spécification intermédiaire
relative aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre
intérieur des conducteurs extérieurs de 13,5 mm à verrouillage à baïonnette - Impédance
caractéristique 50 O (type QLI) (IEC 61169-51:2015)
Ta slovenski standard je istoveten z: EN 61169-51:2015
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61169-51

NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2015
ICS 33.120.30
English Version
Radio-frequency connectors - Part 51: Sectional specification for
RF coaxial connectors with inner diameter of outer conductors
13,5 mm with bayonet lock - Characteristic impedance 50 O
(type QLI)
(IEC 61169-51:2015)
Connecteurs pour fréquences radioélectriques - Partie 51: Hochfrequenz-Steckverbinder - Teil 51:
Spécification intermédiaire relative aux connecteurs Rahmenspezifikation für koaxiale HF Steckverbinder mit
coaxiaux pour fréquences radioélectriques avec diamètre 13,5 mm Innendurchmesser des Außenleiters und
intérieur des conducteurs extérieurs de 13,5 mm à Bajonettverschluss - Wellenwiderstand 50 Ohm (Typ QLI)
verrouillage à baïonnette - Impédance caractéristique 50 O (IEC 61169-51:2015)
(type QLI)
(IEC 61169-51:2015)
This European Standard was approved by CENELEC on 2015-03-12. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61169-51:2015 E
Foreword
The text of document 46F/295/FDIS, future edition 1 of IEC 61169-51, prepared by SC 46F "R.F. and
microwave passive components", of IEC/TC 46 "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN 61169-51:2015.
The following dates are fixed:
(dop) 2015-12-12
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2018-03-12
• latest date by which the national standards conflicting with
the document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61169-51:2015 was approved by CENELEC as a European
Standard without any modification.

- 3 - EN 61169-51:2015
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60529 -  Degrees of protection provided by - -
enclosures (IP Code)
IEC 61169-1 2013 Radio-frequency connectors -- Part 1: EN 61169-1 2013
Generic specification - General
requirements and measuring methods
IEC 62037 series Passive RF and microwave devices, EN 62037 series
intermodulation level measurement
ISO 21207 -  Corrosion tests in artificial atmospheres - - -
Accelerated corrosion tests involving
alternate exposure to corrosion-
promoting gases, neutral salt-spray and
drying
IEC 61169-51 ®
Edition 1.0 2015-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 51: Sectional specification for RF coaxial connectors with inner diameter of

outer conductors 13,5 mm with bayonet lock – Characteristic impedance 50 Ω

(type QLI)
Connecteurs pour fréquences radioélectriques –

Partie 51: Spécification intermédiaire relative aux connecteurs coaxiaux pour

fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs

de 13,5 mm à verrouillage à baïonnette – Impédance caractéristique 50 Ω

(type QLI)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30 ISBN 978-2-8322-2238-6

– 2 – IEC 61169-51:2015 © IEC 2015

CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references. 7
3 Mating face and gauge information . 8
3.1 Dimensions – General connectors . 8
3.1.1 Connector with socket-centre contact . 8
3.1.2 Connector with pin-centre contact. 12
3.2 Gauges for connector with socket-centre contact . 14
3.2.1 Centre contact . 14
3.2.2 Test procedure . 14
3.2.3 Gauge for outer contact . 15
4 Quality assessment procedures . 15
4.1 General . 15
4.2 Ratings and characteristics . 15
4.3 Periodic tests . 18
4.4 Procedures for the qualification approval . 20
4.4.1 Quality conformance inspection . 20
4.4.2 Qualification approval and its maintenance . 20
5 Instructions for preparation of detail specifications (DS) . 20
5.1 General . 20
5.2 Identification of the component . 20
5.3 Performances . 21
5.4 Marking, ordering information and related matters . 21
5.5 Selection of tests, test conditions and severities . 21
5.6 Blank detail specification pro-forma for type QLI connector . 22
6 Marking . 27
6.1 Marking of component . 27
6.2 Marking and contents of package . 27

Figure 1 – Connector with socket-centre contact with 2 options (for dimensions and
key, see Table 1) . 8
Figure 2 – Detail of bayonet lock groove, option 1 (for dimensions and key, see Table 1) . 9
Figure 3 – Detail of bayonet lock groove, option 2 (for dimensions and key, see Table 1) . 9
Figure 4 – Female centre contact (for dimensions and key, see Table 1 . 10
Figure 5 – Connector with pin-centre contact (for dimensions and key, see Table 2) . 12
Figure 6 – Details of pin-centre contact (for dimensions, see Table 2) . 12
Figure 7– Gauge pin for socket-centre contact (for dimensions, see Table 3) . 14
Figure 8 – Gauge ring for socket outer contact (for dimensions, see Table 4) . 15

IEC 61169-51:2015 © IEC 2015 – 3 –
Table 1 – Dimensions of connector with socket-centre contact . 11
Table 2 – Dimensions of connector with pin-centre contact . 13
Table 3 – Gauge dimensions for socket-centre contact . 14
Table 4 – Dimensions of gauge ring for socket outer contact . 15
Table 5 – Rating and characteristics . 16
Table 6 – Acceptance tests . 18
Table 7 – Periodic tests . 19

– 4 – IEC 61169-51:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 51: Sectional specification for
RF coaxial connectors with inner diameter
of outer conductors 13,5 mm with bayonet lock –
Characteristic impedance 50 Ω (type QLI)

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
International Standard IEC 61169-51 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
46F/295/FDIS 46F/310/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

IEC 61169-51:2015 © IEC 2015 – 5 –
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – IEC 61169-51:2015 © IEC 2015
INTRODUCTION
The international Electrotechnical Commission (IEC) draws attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning the
design of the connector given in 3.1.
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/she is willing to negotiate licence
under reasonable and non-discriminatory terms and conditions with applicants throughout the
world. In this respect, the statement of the holders of this patent right is registered with IEC.
More detailed information may be obtained from:
Radiall SA
Mr. Pierre Bigot, RFI Division
Pierre.bigot@radiall.com
Phone:+33 47 650 0057
Z.I Centr’alp – 642 rue Emile Romanet, B.P. 35 – F-38341 Voreppe Cedex, France
Attention is drawn to the possibility that some of elements of this document may be the
subject of patent rights other than those identified above. IEC shall not be held responsible for
identifying any or all such patent rights.
ISO (www.iso.org/patents) and IEC (http://patents.iec.ch) maintain on-line data bases of
patents relevant to their standards. Users are encouraged to consult the data bases for the
most up to date information concerning patents.

IEC 61169-51:2015 © IEC 2015 – 7 –
RADIO-FREQUENCY CONNECTORS –
Part 51: Sectional specification for
RF coaxial connectors with inner diameter
of outer conductors 13,5 mm with bayonet lock –
Characteristic impedance 50 Ω (type QLI)

1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for type QLI R.F. coaxial connectors with quick
lock.
The connectors are normally used with 50 Ω corrugated cable and flexible cables for middle
power applications in an operating range up to 6 GHz.
It describes the interface dimensions for general purpose connectors with gauging information
and the mandatory tests selected from IEC 61169-1 applicable to all detail specifications
relative to type QLI connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a DS and covers all tests schedules and inspection requirements.
NOTE Metric dimension are original dimensions.
All un-dimensioned pictorial configurations are for reference purpose only.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 61169-1:2013, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement
ISO 21207, Corrosion tests in artificial atmospheres – Accelerated corrosion tests involving
alternate exposure to corrosion-promoting gases, neutral salt-spray and drying

– 8 – IEC 61169-51:2015 © IEC 2015
3 Mating face and gauge information
3.1 Dimensions – General connectors
3.1.1 Connector with socket-centre contact

IEC IEC
a) Option 1 − connector for outdoor b) Option 2 − connector for indoor
(1) Reference plane
(2) Slotted and flared to meet mechanical and electrical requirements
(3) Sealing O-ring to meet required electrical and environmental performance
(4) The nut is permitted to use either option 1 or option 2 depending on outdoor or indoor use.
Figure 1 – Connector with socket-centre contact with 2 options
(for dimensions and key, see Table 1)

IEC 61169-51:2015 © IEC 2015 – 9 –

IEC
(1) Reference plane
Figure 2 – Detail of bayonet lock groove, option 1 (for dimensions and key, see Table 1)
IEC
(1) Reference plane
Figure 3 – Detail of bayonet lock groove, option 2 (for dimensions and key, see Table 1)

– 10 – IEC 61169-51:2015 © IEC 2015

IEC
(5) Slotted and closed to meet socket gauge test
Figure 4 – Female centre contact (for dimensions and key, see Table 1

IEC 61169-51:2015 © IEC 2015 – 11 –
Table 1 – Dimensions of connector with socket-centre contact
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

Frequently Asked Questions

EN 61169-51:2015 is a standard published by CLC. Its full title is "Radio-frequency connectors - Part 51: Sectional specification for RF coaxial connectors with inner diameter of outer conductors 13,5 mm with bayonet lock - Characteristic impedance 50 Ohm (type QLI)". This standard covers: IEC 61169-51:2015 provides information and rules for the preparation of detail specifications (DS) for type QLI R.F. coaxial connectors with quick lock. The connectors are normally used with 50 Ohms corrugated cable and flexible cables for middle power applications in an operating range up to 6 GHz. It describes the interface dimensions for general purpose connectors with gauging information and the mandatory tests selected from IEC 61169-1 applicable to all detail specifications relative to type QLI connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements.

IEC 61169-51:2015 provides information and rules for the preparation of detail specifications (DS) for type QLI R.F. coaxial connectors with quick lock. The connectors are normally used with 50 Ohms corrugated cable and flexible cables for middle power applications in an operating range up to 6 GHz. It describes the interface dimensions for general purpose connectors with gauging information and the mandatory tests selected from IEC 61169-1 applicable to all detail specifications relative to type QLI connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements.

EN 61169-51:2015 is classified under the following ICS (International Classification for Standards) categories: 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

You can purchase EN 61169-51:2015 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.