EN 60793-2-30:2002
(Main)Optical fibres - Part 2-30: Product specifications - Sectional specification for category A3 multimode fibres
- BACK
- 04-Apr-2002
- 28-Feb-2005
- 33.180.10
- CLC/TC 86A
Optical fibres - Part 2-30: Product specifications - Sectional specification for category A3 multimode fibres
Applies to optical fibre types A3a, A3b, A3c and A3d. It covers requirements common to A3 multimode fibres. It also covers particular requirements for individual fibre types and specific applications.
Lichtwellenleiter - Teil 2-30: Produktspezifikationen - Rahmenspezifikation für Mehrmodenfasern der Kategorie A3
Fibres optiques - Partie 2-30: Spécifications de produit - Spécification intermédiaire pour les fibres multimodales de catégorie A3
S'applique aux fibres optiques de type A3a, A3b, A3c et A3d. Elle couvre des prescriptions communes aux fibres multimodales de catégorie A3. Elle couvre aussi des prescriptions particulières applicables à des types particuliers de fibres et à des applications données.
Optična vlakna – 2-30. del: Specifikacije izdelka - Področna specifikacija za večrodna vlakna kategorije A3 (IEC 60793-2-30:2002)*
General Information
Relations
This May Also Interest You
IEC 60794-1-209:2024 defines test procedures to be used in establishing uniform requirements for the environmental performance of: - optical fibre cables for use with telecommunication equipment and devices employing similar techniques; and - cables having a combination of both optical fibres and electrical conductors. Throughout this document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This document defines a test standard to determine cable aging performance by high temperature exposure and temperature cycling in order to simulate lifetime behaviour of the attenuation of cables, or physical attributes. See IEC 60794‑1‑2 for a reference guide to test methods of all types and for general requirements and definitions. This document partially cancels and replaces IEC 60794‑1‑22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794‑1‑22:2017: a) the ambient temperature test condition has been defined as per IEC 60794‑1‑2; b) all the maximum allowable attenuation increase values for single-mode and multimode fibres have been deleted, and have been included in the list of details to be specified.
- Draft7 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Jul-2024
- 33.180.10
- CLC/TC 86A
IEC 60794-1-201: 2024 defines test procedures to be used in establishing uniform requirements for the environmental performance of: - optical fibre cables for use with telecommunication equipment and devices employing similar techniques; and - cables having a combination of both optical fibres and electrical conductors. Throughout this document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This document defines a test standard to determine the ability of a cable to withstand the effects of temperature cycling by observing changes in attenuation. See IEC 60794-1-2 for a reference guide to test methods of all types and for general requirements and definitions. This document partially replaces IEC 60794-1-22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-22:2017: a) all references to the temperature sensing device have been removed and replaced with a note "for further study"; b) the conditioning procedure has been separated into Procedure 1 and Procedure 2 to avoid confusion; c) the ambient temperature test condition has been defined as per IEC 60794-1-2; d) the minimum soak time has been decreased for sample mass >16 kg in Table 1.
- Draft11 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Jul-2024
- 33.180.10
- CLC/TC 86A
IEC 60794-1-101:2024 applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors. This document defines test procedures to be used in establishing uniform requirements for tensile performance. Throughout this document the wording "optical cable" includes optical fibre units, microduct fibre units, etc. See IEC 60794-1-2 for general requirements and definitions and for a complete reference guide to test methods of all types.
- Standard12 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Jun-2024
- 33.180.10
- CLC/TC 86A
IEC 60794-1-104:2024 applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors. This document defines test procedures to be used in establishing uniform requirements for impact performance. Throughout this document the wording “optical cable” includes optical fibre units, microduct fibre units, etc. See IEC 60794-1-2 for general requirements and definitions and for a complete reference guide to test methods of all types. This document partially cancels and replaces IEC 60794-1-21:2015, which will be withdrawn. In the context of the revision of IEC 60794-1-21:2015, its contents were split into separate test methods. It includes an editorial revision, based on the new structure and numbering system for optical fibre cable test methods.
- Standard13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Jun-2024
- 33.180.10
- CLC/TC 86A
IEC 60794-1-213:2024 defines test procedures to be used in establishing uniform requirements for the environmental performance of microduct. The test determines the capability of the microduct to withstand internal pressure without leakage and visible damage. This document applies to microduct used for installation of microduct cable or fibre unit by blowing. Throughout this document, the wording "microduct" can also include protected microduct(s). See IEC 60794-1-2 for a reference guide to test methods of all types and for general requirements and definitions.This document partially cancels and replaces IEC 60794-1-22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-22:2017: a) pressure gauge used to monitor internal pressure of microduct added as part of the test apparatus; b) "test temperature" added to the details to be specified; c) added a new subclause “4.7 Details to be reported”.
- Standard10 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Jun-2024
- 33.180.10
- CLC/TC 86A
IEC 60793-1-45:2024 is available as IEC 60793-1-45:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60793-1-45:2024 establishes uniform requirements for measuring the mode field diameter (MFD) of single-mode optical fibre, thereby assisting in the inspection of fibres and cables for commercial purposes. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) modification of the minimum distance between the fibre end and the detector for the direct far field scan (Annex A). b) generalization of the requirement for the minimum dynamic range for all fibre types (Annex A).
- Standard34 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.10
- CLC/TC 86A
IEC 60793-1-41:2024 is available as IEC 60793-1-41:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60793-1-41:2024 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-2-30, and the IEC 60793‑2‑40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are: Method A – Time domain (pulse distortion) measurement Method B – Frequency-domain measurement Method C – Overfilled launch modal bandwidth calculated from differential mode delay (OMBc) Method A and method B can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition. Method C is only defined for A1-OM3 to A1-OM5 multimode fibres and uses a weighted summation of DMD launch responses with the weights corresponding to an overfilled launch condition. The relevant test method and launch condition is chosen according to the type of fibre. NOTE 1 These test methods are commonly used in production and research facilities and are not easily accomplished in the field. NOTE 2 OFL has been used for the modal bandwidth value for LED-based applications for many years. However, no single launch condition is representative of the laser (e.g. VCSEL) sources that are used for gigabit and higher rate transmission. This fact drove the development of IEC 60793-1-49 for determining the effective modal bandwidth of laser optimized 50 µm fibres. See IEC 60793-2-10 and IEC 61280-4-1 for more information. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the addition of a direct reference for method A and method B.
- Standard33 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-May-2024
- 33.180.10
- CLC/TC 86A
IEC 60794-1-212:2024 defines the test procedure to examine the attenuation behaviour (change in attenuation) when an optical fibre cable with cable elements fixed at both ends is subjected to temperature cycling. This test assesses the attenuation behaviour of a cable under a no-end movement condition intended for termination with, for example, interconnecting devices or passive components. This document partially cancels and replaces IEC 60794-1-22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-22:2017: a) the description of the test method has been changed to “with cable elements fixed at both ends”; b) subclauses have been added to the procedure clause; c) the preparation of cable sample and test set-up has been arranged in a logical way; d) Figure 1 has been added for illustration of the preparation of cable sample, DUT and test set-up; e) the temperature chamber temperature tolerance has been changed to ± 3 °C as done in IEC 60794‑1‑22, method F1; f) all required steps have been added to the subclause for temperature cycling as well as the table for the minimum soak time and the figure for the cycle procedure, and removed the reference to IEC 60794-1-22, method F1; g) the maximum change in attenuation has been added to the details to be specified; h) a new subclause 4.5 has been added for details to be reported.
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 23-May-2024
- 33.180.10
- CLC/TC 86A
IEC 60794-1-217:2024 series defines the test procedure to measure the permanent fibre protrusion compared to the cable elements and cable sheath due to thermal exposure of a cable. This document partially replaces IEC 60794‑1‑22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794‑1‑22:2017: a) added clarification in the objective that the purpose of this test procedure is to measure the permanent fibre protrusion of cables without rigid strength members; b) replaced the reference to method F1 for the apparatus with a detailed description for the temperature chamber and temperature sensing device as done in IEC 60794-1-211; c) added a measuring device in the subclause for apparatus; d) added conditioning before cutting the cable sample as done in IEC 60794-1-211 e) added all required steps in the subclause for temperature cycling as well as the table for the minimum soak time and the figure for the cycle procedure, and removed the reference to IEC 60794-1-22, method F1; f) improved the figures and added a figure for preparation of the cable sample; g) added the informative Annex A for the test procedure recommended for cables with rigid strength members.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
- 23-May-2024
- 33.180.10
- CLC/TC 86A
IEC 60794-1-312: 2024 describes test procedures to be used in establishing uniform requirements of optical fibre cable elements for the mechanical property – tensile strength and elongation at low temperature. This document applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors. Throughout the document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This document partially cancels and replaces method G11B of IEC 60794-1-23:2019. This edition includes the following significant technical changes with respect to IEC 60794‑1‑23:2019: a) alignment of the title with the content of the method.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-Mar-2024
- 33.180.10
- CLC/TC 86A
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.