Shunt power capacitors of the non-self-healing type for AC systems having a rated voltage up to and including 1 000 V - Part 1: General

IEC 60931-1:2025 is applicable to both non-self-healing capacitor units and non-self-healing capacitor banks intended to be used, particularly, for power-factor correction of AC power systems having a rated voltage up to and including 1 000 V and frequencies 15 Hz to 60 Hz. This document also applies to capacitors intended for use in power filter circuits.

Nichtselbstheilende Leistungs-Parallelkondensatoren für Wechselstromanlagen mit einer Nennspannung bis einschließlich 1000 V – Teil 1: Allgemeines

Condensateurs shunt de puissance non autorégénérateurs pour réseaux à courant alternatif de tension assignée inférieure ou égale à 1 000 V - Partie 1 : Généralités

IEC 60931-1:2025 La présente partie de l’IEC 60931 s’applique aux condensateurs unitaires non autorégénérateurs et aux batteries de condensateurs non autorégénérateurs destinés plus particulièrement à la correction du facteur de puissance des réseaux à courant alternatif de tension assignée inférieure ou égale à 1 000 V et de fréquence comprise entre 15 Hz et 60 Hz. Le présent document s’applique également aux condensateurs destinés à être utilisés dans des circuits de filtrage de puissance.

Nesamoozdravljivi vzporedni močnostni kondenzatorji za izmenične tokovne sisteme z naznačeno napetostjo do vključno 1000 V - 1. del: Splošno (IEC 60931-1:2025)

Ta del standarda IEC 60931 se uporablja za nesamoozdravljive kondenzatorske enote in nesamoozdravljive kondenzatorske baterije, namenjene zlasti za korekcijo faktorja moči izmeničnih tokovnih sistemov z naznačeno napetostjo do vključno 1000 V in s frekvencami 15 Hz do 60 Hz.
Ta dokument se uporablja tudi za kondenzatorje, namenjene uporabi v močnostnih filtrirnih vezjih. Dodatne definicije, zahteve in preskusi za filtrirne kondenzatorje so navedeni v dodatku A.
V tem delu standarda IEC 60931 niso obravnavani naslednji kondenzatorji:
– samoozdravljivi vzporedni energetski kondenzatorji za izmenično-tokovne sisteme z naznačeno napetostjo do vključno 1000 V (skupina standardov IEC 60831 [1]1);
– vzporedni kondenzatorji za izmenične napajalne sisteme z naznačeno napetostjo nad 1000 V (skupina standardov IEC 60871 [2]);
– vzporedni močnostni kondenzatorji za naprave za indukcijsko gretje (skupina standardov IEC 60110 [3]);
– zaporedni kondenzatorji za elektroenergetske sisteme (skupina standardov IEC 60143 [4]);
– kondenzatorji za motorje (skupina standardov IEC 60252 [5]);
– sklopni kondenzatorji in kondenzatorski delilniki (skupina standardov IEC 60358 [6]);
– kondenzatorji za močnostno elektroniko (IEC 61071 [7]);
– majhni kondenzatorji za izmenični tok za fluorescenčne in druge sijalke (IEC 61048 [8] in IEC 61049 [9]);
– kondenzatorji za odpravljanje radijskih motenj (v obravnavi);
– kondenzatorji, namenjeni uporabi v različnih vrstah električne opreme, zaradi česar se štejejo za komponente;
– kondenzatorji, namenjeni uporabi z izmenično napetostjo, superponirano na enosmerno napetost;
– samoozdravljivi vzporedni energetski kondenzatorji za izmenične tokovne sisteme z naznačeno napetostjo nad 1000 V (IEC 63210 [10]).
Dodatna oprema, kot so izolatorji, stikala, instrumentni transformatorji, varovalke itd. mora biti v skladu z ustreznimi standardi IEC.
Namen tega dokumenta je:
a) določiti enotna pravila glede zmogljivosti, preskušanja in ocenjevanja;
b) določiti posebna varnostna pravila;
c) zagotoviti navodila za namestitev in delovanje.

General Information

Status
Published
Publication Date
28-Aug-2025
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
29-Aug-2025
Due Date
03-Oct-2025
Completion Date
29-Aug-2025

Relations

Standard
EN IEC 60931-1:2025
English language
43 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2025
Nadomešča:
SIST EN 60931-1:1999
SIST EN 60931-1:1999/A1:2003
Nesamoozdravljivi vzporedni močnostni kondenzatorji za izmenične tokovne
sisteme z naznačeno napetostjo do vključno 1000 V - 1. del: Splošno (IEC 60931-
1:2025)
Shunt power capacitors of the non-self-healing type for AC systems having a rated
voltage up to and including 1000 v - Part 1: General (IEC 60931-1:2025)
Nichtselbstheilende Leistungs-Parallelkondensatoren für Wechselstromanlagen mit einer
Nennspannung bis einschließlich 1000 V - Teil 1: Allgemeines (IEC 60931-1:2025)
Condensateurs shunt de puissance non autorégénérateurs pour réseaux à courant
alternatif de tension assignée inférieure ou égale à 1000 v - Partie 1: Généralités (IEC
60931-1:2025)
Ta slovenski standard je istoveten z: EN IEC 60931-1:2025
ICS:
29.120.99 Druga električna dodatna Other electrical accessories
oprema
31.060.70 Močnostni kondenzatorji Power capacitors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 60931-1

NORME EUROPÉENNE
EUROPÄISCHE NORM August 2025
ICS 29.120.99; 31.060.70 Supersedes EN 60931-1:1996; EN 60931-1:1996/A1:2003
English Version
Shunt power capacitors of the non-self-healing type for AC
systems having a rated voltage up to and including 1 000 V -
Part 1: General
(IEC 60931-1:2025)
Condensateurs shunt de puissance non autorégénérateurs Nichtselbstheilende Leistungs-Parallelkondensatoren für
pour réseaux à courant alternatif de tension assignée Wechselstromanlagen mit einer Nennspannung bis
inférieure ou égale à 1 000 V - Partie 1 : Généralités einschließlich 1000 V - Teil 1: Allgemeines
(IEC 60931-1:2025) (IEC 60931-1:2025)
This European Standard was approved by CENELEC on 2025-07-31. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2025 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60931-1:2025 E

European foreword
The text of document 33/721/FDIS, future edition 3 of IEC 60931-1, prepared by TC 33 "Power
capacitors and their applications" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN IEC 60931-1:2025.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2026-08-31
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2028-08-31
document have to be withdrawn
This document supersedes EN 60931-1:1996 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 60931-1:2025 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standard indicated:
IEC 60831 series NOTE Approved as EN 60831 series
IEC 60871 series NOTE Approved as EN 60871 series
IEC 60110 series NOTE Approved as EN 60110 series
IEC 60143 series NOTE Approved as EN IEC 60143 series
IEC 60252 series NOTE Approved as EN 60252 series
IEC 60358 series NOTE Approved as EN IEC 60358 series
IEC 61071 NOTE Approved as EN 61071
IEC 61048 NOTE Approved as EN 61048
IEC 61049 NOTE Approved as EN 61049
IEC 63210 NOTE Approved as EN IEC 63210
IEC 60831-1:2014 NOTE Approved as EN 60831-1:2014 (not modified)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cencenelec.eu.
Publication Year Title EN/HD Year
IEC 60060-1 - High-voltage test techniques - Part 1: EN IEC 60060-1 -
General terminology and test requirements
IEC 60931-2 - Shunt power capacitors of the non-self- EN IEC 60931-2 -
healing type for AC systems having a rated
voltage up to and including 1 000 V - Part
2: Ageing test and destruction test
IEC 61000-2-2 2002 Electromagnetic compatibility (EMC) - Part EN 61000-2-2 2002
2-2: Environment - Compatibility levels for
low-frequency conducted disturbances and
signalling in public low-voltage power
supply systems
IEC/TR 61000-4-1 - Electromagnetic compatibility (EMC) - Part - -
4-1: Testing and measurement techniques
- Overview of the IEC 61000-4 series

IEC 60931-1 ®
Edition 3.0 2025-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Shunt power capacitors of the non-self-healing type for AC systems having a
rated voltage up to and including 1 000 V –
Part 1: General
Condensateurs shunt de puissance non autorégénérateurs pour réseaux à
courant alternatif de tension assignée inférieure ou égale à 1 000 V –
Partie 1 : Généralités
ICS 29.120.99, 31.060.70 ISBN 978-2-8327-0506-3

IEC 60931-1:2025-06(en-fr)
IEC 60931-1:2025 © IEC 2025
CONTENTS
FOREWORD. 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 7
4 Service conditions . 10
4.1 Normal service conditions . 10
4.2 Unusual service conditions . 11
5 Test requirements . 11
5.1 General . 11
5.2 Test conditions . 11
6 Tests . 11
6.1 Classification . 11
6.1.1 General . 11
6.1.2 Routine tests . 11
6.1.3 Type tests . 12
6.1.4 Acceptance tests. 12
6.2 Capacitance measurement and output calculation . 13
6.2.1 Measuring procedure . 13
6.2.2 Capacitance tolerances . 13
6.3 Measurement of the tangent of the loss angle (tan δ) of the capacitor . 13
6.3.1 Measuring procedure . 13
6.3.2 Loss requirements . 14
6.4 Voltage tests between terminals . 14
6.4.1 Routine test . 14
6.4.2 Type test . 14
6.5 Voltage tests between terminals and container . 14
6.5.1 Routine test . 14
6.5.2 Type test . 15
6.6 Test of internal discharge device . 15
6.7 Sealing test . 15
6.8 Thermal stability test . 16
6.9 Measurement of the tangent of the loss angle (tan δ) of the capacitor at
elevated temperature . 17
6.9.1 Measuring procedure . 17
6.9.2 Requirements . 17
6.10 Lightning impulse voltage test between terminals and container . 17
6.11 Discharge test . 18
6.12 Ageing test . 18
6.13 Destruction test . 18
6.14 Disconnecting test on internal fuses . 18
6.14.1 General . 18
6.14.2 Test procedure . 19
6.14.3 Capacitance measurement . 19
6.14.4 Inspection of the unit . 20
6.14.5 Voltage test after opening the container . 20
7 Maximum permissible voltage . 20
IEC 60931-1:2025 © IEC 2025
7.1 Long-duration voltages . 20
7.2 Switching voltages . 21
8 Maximum permissible current . 21
9 Discharge device . 21
10 Container connections . 22
11 Protection of the environment . 22
12 Other safety requirements . 22
13 Marking of the unit . 22
13.1 Rating plate . 22
13.2 Standardized connection symbols . 23
13.3 Warning plate . 23
14 Marking of the bank . 23
14.1 Instruction sheet or rating plate . 23
14.2 Warning plate . 23
15 General . 24
16 Choice of the rated voltage . 24
17 Operating temperature . 25
17.1 General . 25
17.2 Installation . 25
17.3 High ambient air temperature . 25
17.4 Evaluation of losses . 25
18 Special service conditions . 26
19 Overvoltages . 26
20 Overload currents . 27
21 Switching and protective devices and connections . 27
22 Choice of creepage distance . 28
23 Capacitors connected to systems with audio-frequency remote control. 28
24 Electromagnetic compatibility (EMC) . 29
24.1 Emission . 29
24.2 Immunity . 29
24.2.1 General . 29
24.2.2 Low-frequency disturbances . 29
24.2.3 Conducted transients and high-frequency disturbances . 29
24.2.4 Electrostatic discharges . 29
24.2.5 Magnetic disturbances . 29
24.2.6 Electromagnetic disturbances . 30
Annex A (normative) Additional definitions, requirements and tests for power filter
capacitors . 31
A.1 Additional terms and definitions . 31
A.1.1 Band-pass and high-pass filter capacitor (filter capacitor) . 31
A.1.2 Rated voltage (U ) (see 3.11) . 31
N
A.1.3 Rated output (Q ) (see 3.10) . 31
N
A.1.4 Rated current (I ) (see 3.16) . 31
N
A.2 Quality requirements and tests . 31
A.2.1 Capacitance tolerance . 31
A.2.2 Voltage test between terminals (see 6.4) . 32
IEC 60931-1:2025 © IEC 2025
A.2.3 Thermal stability test (see 6.8) . 32
A.3 Overloads – Maximum permissible current (see Clause 8) . 32
A.4 Markings – Instruction sheet or rating plate (see 14.1) . 32
A.5 Guide for installation and operation – Choice of the rated voltage
(see Clause 16). 32
Annex B (informative) Formulae for capacitors and installations . 33
B.1 Computation of the output of three-phase capacitor from three single-phase
capacitance measurements . 33
B.2 Resonance frequency . 33
B.3 Voltage rise . 33
B.4 Inrush transient current . 34
B.4.1 Switching in of single capacitor . 34
B.4.2 Switching of capacitors in parallel with energized capacitor(s) . 34
B.4.3 Discharge resistance in single-phase units or in one-phase or
polyphase units . 34
Annex C (normative) Test procedures for the disconnecting test on internal fuses . 36
C.1 General . 36
C.2 Test procedure . 36
Annex D (informative) Guidance for coordination of fuse protection . 38
D.1 General . 38
D.2 Protection sequence . 38
Bibliography . 39

Figure B.1 – k values depending on the method of connection of the resistors with the
capacitor units . 35

Table 1 – Letter symbols for upper limit of temperature range . 10
Table 2 – Ambient air temperature for the thermal stability test . 16
Table 3 – Admissible voltage levels in service . 20

IEC 60931-1:2025 © IEC 2025
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Shunt power capacitors of the non-self-healing type for AC systems
having a rated voltage up to and including 1 000 V –
Part 1: General
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 60931-1 has been prepared by IEC technical committee 33: Power capacitors and their
applications. It is an International Standard.
This third edition cancels and replaces second edition published in 1996 and
Amendment 1:2002. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) integration of IEC 60931-3 within IEC 60931-1;
b) deletion of self-healing test.
IEC 60931-1:2025 © IEC 2025
The text of this International Standard is based on the following documents:
Draft Report on voting
33/721/FDIS 33/725/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all parts in the IEC 60931 series, published under the general title Shunt power
capacitors of the non-self-healing type for AC systems having a rated voltage up to and
including 1 000 volts, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn, or
• revised.
IEC 60931-1:2025 © IEC 2025
1 Scope
This part of IEC 60931 is applicable to both non-self-healing capacitor units and non-self-
healing capacitor banks intended to be used, particularly, for power-factor correction of AC
power systems having a rated voltage up to and including 1 000 V and frequencies 15 Hz to
60 Hz.
This document also applies to capacitors intended for use in power filter circuits. Additional
definitions, requirements, and tests for filter capacitors are given in Annex A.
The following capacitors are excluded from this part of IEC 60931:
– Shunt power capacitors of the self-healing type for AC systems having a rated voltage up
to and including 1 000 V (IEC 60831 series [1] )
– Shunt capacitors for AC power systems having a rated voltage above 1 000 V (IEC 60871
series [2])
– Power capacitors for induction heating installations (IEC 60110 series [3])
– Series capacitors for power systems (IEC 60143 series [4])
– Capacitors for motor applications (IEC 60252 series [5])
– Coupling capacitors and capacitor dividers (IEC 60358 series [6])
– Capacitors for power electronics (IEC 61071 [7])
– Small AC capacitors to be used for fluorescent and discharge lamps (IEC 61048 [8] and
IEC 61049 [9])
– Capacitors for suppression of radio interference (under consideration)
– Capacitors intended to be used in various types of electrical equipment and thus considered
as components
– Capacitors intended for use with DC voltage superimposed on the AC voltage
– Shunt power capacitors of the self-healing type for AC systems having a rated voltage above
1 000 V (IEC 63210 [10])
Accessories such as insulators, switches, instrument transformers, fuses, etc., are to be in
accordance with the relevant IEC standards.
The purpose of this document is:
a) to formulate uniform rules regarding performances, testing and rating;
b) to formulate specific safety rules;
c) to provide a guide for installation and operation.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60060-1, High-voltage test techniques – Part 1: General definitions and test requirements
IEC 60931-2, Shunt power capacitors of the non-self-healing type for a.c. systems having a
rated voltage up to and including 1000 V – Part 2: Ageing test and destruction test
___________
Numbers in square brackets refer to the Bibliography.
IEC 60931-1:2025 © IEC 2025
IEC 61000-2-2:2002, Electromagnetic compatibility (EMC) – Part 2-2: Environment –
Compatibility levels for low-frequency conducted disturbances and signalling in public low-
voltage power supply systems
IEC TR 61000-4-1, Electromagnetic compatibility (EMC) – Part 4-1: Testing and measurement
techniques – Overview of IEC 61000-4 series
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
• IEC Electropedia: available at https://www.electropedia.org/
• ISO Online browsing platform: available at https://www.iso.org/obp
3.1
capacitor element
element
device consisting essentially of two electrodes separated by a dielectric
[SOURCE: IEC 60050-436:1990 [11], 436-01-03]
3.2
capacitor unit
unit
assembly of one or more capacitor elements in the same container with terminals brought out
[SOURCE: IEC 60050-436:1990 [11], 436-01-04]
3.3
non-self-healing capacitor
capacitor in which the dielectric, after local break-down, is not restored
3.4
capacitor bank
bank
number of capacitor units connected so as to act together
[SOURCE: IEC 60050-436:1990 [11], 436-01-06]
3.5
capacitor
generic term, encompassing the notions of capacitor unit and capacitor bank
Note 1 to entry: In this part of IEC 60931, the word capacitor is used when it is not necessary to lay particular stress
upon the different meanings of the words capacitor unit or capacitor bank.
[SOURCE: IEC 60831-1:2014 [12], 3.5]
IEC 60931-1:2025 © IEC 2025
3.6
discharge device
device which may be incorporated in a capacitor, capable of reducing the
voltage between the terminals practically to zero, within a given time, after the capacitor has
been disconnected from a network
[SOURCE: IEC 60050-436:1990 [11], 436-03-15, modified – "intended to" replaced with
"capable of", "to a given value" replaced with "practically to zero"]
3.7
internal fuse
fuse connected inside a capacitor unit, in series with an element or a group of
elements
[SOURCE: IEC 60050-436:1990 [11], 436-03-16]
3.8
line terminal
terminal intended for connection to a line conductor of a network
Note 1 to entry: In polyphase capacitors, a terminal intended to be connected to the neutral conductor is not
considered to be a line terminal.
[SOURCE: IEC 60050-436:1990 [11], 436-03-01]
3.9
rated capacitance
C
N
capacitance value for which the capacitor has been designed
[SOURCE: IEC 60050-436:1990 [11], 436-01-12, modified – "derived from the values of rated
output, voltage and frequency of the capacitor" replaced with "for which the capacitor has been
designed"]
3.10
rated output
Q
N
reactive power derived from the rated values of capacitance, frequency and
voltage
[SOURCE: IEC 60050-436:1990 [11], 436-01-16, modified – "for which the capacitor has been
designed" replaced with "derived from the rated values of capacitance, frequency and voltage"]
3.11
rated voltage
U
N
RMS value of the alternating voltage for which the capacitor has been designed
Note 1 to entry: In the case of capacitors consisting of one or more separate circuits (such as single-phase units
intended for use in polyphase connection, or polyphase units with separate circuits), U refers to the rated voltage
N
of each circuit.
Note 2 to entry: For polyphase capacitors with internal electrical connections between the phases, and for
polyphase capacitor banks, U refers to the phase-to-phase voltage.
N
[SOURCE: IEC 60050-436:1990 [11], 436-01-15]
IEC 60931-1:2025 © IEC 2025
3.12
rated frequency
f
N
frequency for which the capacitor has been designed
[SOURCE: IEC 60050-436:1990 [11], 436-01-14]
3.13
rated current
I
N
RMS value of the alternating current for which the capacitor has been designed
[SOURCE: IEC 60050-436:1990 [11], 436-01-13]
3.14
capacitor losses
active power dissipated in the capacitor
Note 1 to entry: All loss-producing components should be included, for example:
– for a unit, losses from dielectric, internal fuses, internal discharge resistor, connections, etc.
– for a bank, losses from units, external fuses, busbars, discharge and damping reactors, etc.
[SOURCE: IEC 60050-436:1990 [11], 436-04-10]
3.15
tangent of the loss angle
tan δ
ratio between the equivalent series resistance and the capacitive reactance of
the capacitor at specified sinusoidal alternating voltage and frequency
[SOURCE: IEC 60050-436:1990 [11], 436-04-11]
3.16
ambient air temperature
temperature of the air at the proposed location of the capacitor.
3.17
cooling air temperature
temperature of the cooling air measured at the hottest position in the bank, under steady-state
conditions, midway between two units
Note 1 to entry: If only one unit is involved, it is the temperature measured at a point approximately 0,1 m away
from the capacitor container and at two-thirds of the height from its base.
[SOURCE: IEC 60831-1:2014 [12], 3.22]
3.18
steady-state condition
thermal equilibrium attained by the capacitor at constant output and at constant ambient air
temperature
3.19
residual voltage
the voltage remaining on the terminals of a capacitor at a certain time following disconnection
IEC 60931-1:2025 © IEC 2025
3.20
rated voltage
U
Ne
RMS value of the alternating voltage for which the capacitor element
has been designed
4 Service conditions
4.1 Normal service conditions
This document gives requirements for capacitors intended for use in the following conditions:
a) Residual voltage at energization
Not to exceed 10 % rated voltage (Clause 9, Clause 19, and Annex B).
b) Altitude
Not exceeding 2 000 m.
c) Ambient air temperature categories
Capacitors are classified in temperature categories, each category being specified by a number
followed by a letter. The number represents the lowest ambient air temperature at which the
capacitor may operate.
The letters represent upper limits of temperature variation ranges, having maximum values
specified in Table 1. The temperature categories cover the temperature range of −50 °C to
+55 °C.
The lowest ambient air temperature at which the capacitor may be operated should be chosen
from the five preferred values +5 °C, −5 °C, −25 °C, −40 °C, −50 °C.
For indoor use, a lower limit of −5 °C is normally applicable.
Table 1 is based on service conditions in which the capacitor does not influence the ambient
air temperature (for example outdoor installations).
Table 1 – Letter symbols for upper limit of temperature range
Symbol Ambient temperature
°C
Maximum Highest mean over any period of
24 h 1 year
A 40 30 20
B 45 35 25
C 50 40 30
D 55 45 35
The temperature values according to Table 1 can be found in the meteorological temperature
table covering the installation site.
Higher temperature values than those indicated in Table 1 can be considered in special
applications by mutual agreement between manufacturer and purchaser. In that case, the
temperature category should be indicated by the combination of minimum and maximum
temperature values, for example, −40/60.
IEC 60931-1:2025 © IEC 2025
If the capacitor influences the air temperature, the ventilation and/or choice of capacitor shall
be such that the Table 1 limits are maintained. The cooling air temperature in such an
installation shall not exceed the temperature limits of Table 1 by more than 5 °C.
Any combination of minimum and maximum values may be chosen for the standard temperature
category of a capacitor, for example −40/A or −5/C.
Preferred temperature categories are:
−40/A, −25/A, −5/A and −5/C.
4.2 Unusual service conditions
Unless otherwise agreed between manufacturer and purchaser, this document does not apply
to capacitors, the service conditions of which, in general, are incompatible with the
requirements of this document.
5 Test requirements
5.1 General
This clause gives the test requirements for capacitor units and, when specified, for capacitor
elements.
Supporting insulators, switches, instrument transformers, fuses, etc, shall be in accordance
with relevant IEC standards.
5.2 Test conditions
Unless otherwise specified for a particular test or measurement, the temperature of the
capacitor dielectric at the start of the test shall be in the range of +5 °C to +35 °C.
It may be assumed that the dielectric temperature is the same as the ambient temperature,
provided that the capacitor has been left in an unenergized state at constant ambient
temperature for an adequate period. When a correction has to be applied, the reference
temperature to be used is +20 °C, unless otherwise agreed between the manufacturer and the
purchaser.
The AC tests and measurements shall be carried out at a frequency of 50 Hz or 60 Hz ± 2 Hz,
independent of the rated frequency of the capacitor, if not otherwise specified.
6 Tests
6.1 Classification
6.1.1 General
The tests are classified as routine tests, type tests and acceptance tests.
6.1.2 Routine tests
The following tests are routine tests. For details, reference should be made to the relevant
clauses or subclauses.
a) Capacitance measurement and output calculation (see 6.2).
b) Measurement of the tangent of the loss angle (tan δ) of the capacitor (see 6.3).
c) Voltage test between terminals (see 6.4.1).
IEC 60931-1:2025 © IEC 2025
d) Voltage test between terminals and container (see 6.5.1).
e) Test of the internal discharge device (see 6.6).
f) Sealing test (see 6.7).
Routine tests shall have been carried out by the manufacturer on every capacitor before
delivery. The purchaser shall, on request, be supplied with a certificate detailing the results of
such tests.
In general, the indicated sequence of the tests is not mandatory.
6.1.3 Type tests
The following tests are type tests. For details, reference should be made to the relevant clauses
or subclauses:
a) Thermal stability test (see 6.8).
b) Measurement of the tangent of the loss angle (tan δ) of the capacitor at elevated
temperature (see 6.9).
c) Voltage test between terminals (see 6.4.2).
d) Voltage test between terminals and container (see 6.5.2).
e) Lightning impulse voltage test between terminals and container (see 6.10).
f) Discharge test (see 6.11).
g) Ageing test (see 6.12).
h) Destruction test (see 6.13).
i) Disconnecting test on internal fuses (see 6.14).
Type tests are carried out in order to ascertain that, as regards design, size, materials and
construction, the capacitor complies with the specified characteristics and operation
requirements detailed in this document.
Unless otherwise specified, every capacitor sample to which it is intended to apply the type test
shall first have withstood satisfactorily the application of all the routine tests.
The type tests shall have been carried out by the manufacturer, and the purchaser shall, on
request, be supplied with a certificate detailing the results of such tests.
The successful completion of each type test is also valid for units having the same rated voltage
and lower output, provided that they do not differ in any way that can influence the properties
to be checked by the test. It is not essential that all type tests be carried out on the same
capacitor sample.
The number of samples for the type test shall be subjected to agreement between the
manufacturer and user.
6.1.4 Acceptance tests
The routine and/or type tests, or some of them, may be repeated by the manufacturer in
connection with any contract by agreement with the purchaser. The kind of tests, the number
of samples that may be subjected to such repeated tests and the acceptance criteria shall be
subject to agreement between manufacturer and purchaser, and shall be stated in the contract.
IEC 60931-1:2025 © IEC 2025
6.2 Capacitance measurement and output calculation
6.2.1 Measuring procedure
The capacitance shall be measured at the voltage and the frequency chosen by the
manufacturer. The method used shall not include errors due to harmonics or to accessories
external to the capacitor to be measured such as reactors and blocking circuits in the measuring
circuit. The accuracy of the measuring method and the correlation with the values measured at
rated voltage and frequency shall be given.
The capacitance measurement shall be carried out after the voltage test between terminals
(see 6.4).
Measurement at a voltage between 0,9 and 1,1 times the rated voltage, and at a frequency
between 0,8 and 1,2 times the rated frequency, shall be performed on the capacitor used for
the thermal stability test (see 6.8) and the ageing test (see 6.12) before these tests, and may
be performed on other capacitors on request of the purchaser in agreement with the
manufacturer.
6.2.2 Capacitance tolerances
The capacitance shall not differ from the rated capacitance by more than
–5 % to +10 % for units and banks up to and including 100 kvar,
–5 % to +5 % for units and banks above 100 kvar.
The capacitance value is that measured under the conditions of 6.2.1.
In three-phase units, the ratio of maximum to minimum value of the capacitance measured
between any two line terminals shall not exceed 1,08.
NOTE A formula for calculation of the output of a three-phase capacitor from single-phase capacitance
measurement is given in Annex B.
6.3 Measurement of the tangent of the loss angle (tan δ) of the capacitor
6.3.1 Measuring procedure
The capacitor losses (tan δ) shall be measured at the voltage and the frequency chosen by the
manufacturer. The method used shall not include errors due to harmonics or to accessories
external to the capacitor to be me
...