EN 60317-43:1997/A1:2010
(Amendment)Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240
Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240
Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten - Teil 43: Runddrähte aus Kupfer, mit Band aus aromatischem Polyimid umwickelt, Klasse 240
Spécifications pour types particuliers de fils de bobinage - Partie 43: Fil de section circulaire en cuivre recouvert d'un ruban de polyimide aromatique, classe 240
Specifikacije za posebne tipe navitij - 43. del: Z aromatičnim poliimidom ovit bakren okrogel vodnik, razred 240 (IEC 60317-43:1997/A1:2010)
Amandma A1:2010 je dodatek k standardu SIST EN 60317-43:2001
Določa zahteve za ovit bakren okrogel vodnik razreda 240. Izolacija je sestavljena iz enkrat ali dvakrat ovitega traku iz aromatičnega poliimidioma. Razred 240 je toplotni razred, ki zahteva minimalni temperaturni indeks 240 in temperaturo toplotnega šoka vsaj 260 °C. Trak je na eni ali obeh straneh prevlečen s primernim lepilom, na primer s fluoriranim etilen-propilenom. Po ovitju se trak termično zatesni, da nastane neprekinjen in oprijet ovoj. Specifične zahteve so lahko predmet pogodbe.
General Information
- Status
- Published
- Publication Date
- 08-Apr-2010
- Withdrawal Date
- 31-Mar-2013
- Technical Committee
- CLC/TC 55 - Winding wires
- Drafting Committee
- IEC/TC 55 - IEC_TC_55
- Parallel Committee
- IEC/TC 55 - IEC_TC_55
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 09-Apr-2010
- Completion Date
- 09-Apr-2010
Relations
- Effective Date
- 29-Jan-2023
Overview
EN 60317-43:1997/A1:2010 (identical to IEC 60317-43:1997/A1:2010) defines specifications for a particular type of winding wire: aromatic polyimide tape wrapped round copper wire, thermal class 240. Published by CENELEC/CENELEC members as a European adoption of the IEC standard, Amendment A1 (2010) updates normative references and certain test clauses. This standard applies to manufacturers, test laboratories, designers and specifiers who require high‑temperature insulated winding wire with polyimide tape insulation.
Key topics and requirements
- Product description: Round copper conductor with an external wrapping of aromatic polyimide tape-intended for winding applications where high thermal performance is required (class 240).
- Thermal class: Designated class 240, indicating suitability for high‑temperature service in accordance with insulation class conventions.
- Normative references: The amendment updates references (adds prefix “60” to normative references) and lists essential test standards such as the IEC 60172 procedure for temperature index determination and the IEC 60851 series of winding‑wire test methods.
- Testability notes introduced in A1:
- The clause on elongation has been replaced with the statement “Test inappropriate.”
- A new Clause 23 (Pin hole test) is added and similarly marked “Test inappropriate.”
- Reference to IEC 60172 (temperature index test) is retained; the amendment removes the year from that reference.
- Regulatory and national adoption: Amendment A1 was approved by CENELEC and national electrotechnical committees; the amendment must be implemented as a national standard without alteration.
Applications
- Specifying and producing insulated winding wire for:
- Electric motors and generators requiring high‑temperature insulation
- Power and distribution transformers
- High‑temperature coils, reactors and solenoids
- Aerospace, automotive, and industrial equipment where elevated thermal endurance and reliable insulation are critical
- Used by:
- Wire and cable manufacturers creating class‑rated winding products
- Design engineers selecting insulation systems for high‑temperature applications
- Test laboratories and compliance teams verifying conformity to EN/IEC winding‑wire requirements
- Procurement and quality assurance groups specifying materials for long‑term thermal performance
Related standards
- IEC 60172 - Test procedure for determination of temperature index of enamelled winding wires
- IEC 60851 series - Winding wires - Test methods
- ISO 3 - Preferred numbers (referenced for conductor sizing where applicable)
This standard is essential when specifying or verifying polyimide tape wrapped copper winding wire (class 240) for high‑temperature electrical applications. Keywords: EN 60317-43, IEC 60317-43, polyimide tape winding wire, class 240, winding wires standard, aromatic polyimide insulation.
Get Certified
Connect with accredited certification bodies for this standard

UL Solutions
Global safety science company with testing, inspection and certification.
CEPREI Certification Center (Guangzhou Saibao)
Pioneer of third-party certification, subsidiary of Electronic Fifth Research Institute.
CESI Beijing Certification (Saisi)
Subsidiary of China Electronics Standardization Institute (CESI), established 1963.
Sponsored listings
Frequently Asked Questions
EN 60317-43:1997/A1:2010 is a amendment published by CLC. Its full title is "Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240". This standard covers: Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240
Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240
EN 60317-43:1997/A1:2010 is classified under the following ICS (International Classification for Standards) categories: 29.060.10 - Wires. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60317-43:1997/A1:2010 has the following relationships with other standards: It is inter standard links to EN 60317-43:1997. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60317-43:1997/A1:2010 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2010
6SHFLILNDFLMH]DSRVHEQHWLSHQDYLWLMGHO=DURPDWLþQLPSROLLPLGRPRYLW
EDNUHQRNURJHOYRGQLNUD]UHG,(&$
Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape
wrapped round copper wire, class 240 (IEC 60317-43:1997/A1:2010)
Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten - Teil 43:
Runddrähte aus Kupfer, mit Band aus aromatischem Polyimid umwickelt, Klasse 240
(IEC 60317-43:1997/A1:2010)
Spécifications pour types particuliers de fils de bobinage - Partie 43: Fil de section
circulaire en cuivre recouvert d'un ruban de polyimide aromatique, classe 240 (CEI
60317-43:1997/A1:2010)
Ta slovenski standard je istoveten z: EN 60317-43:1997/A1:2010
ICS:
29.060.10 Žice Wires
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 60317-43/A1
NORME EUROPÉENNE
April 2010
EUROPÄISCHE NORM
ICS 29.060.10
English version
Specifications for particular types of winding wires -
Part 43: Aromatic polyimide tape wrapped round copper wire, class 240
(IEC 60317-43:1997/A1:2010)
Spécifications pour types particuliers Technische Lieferbedingungen
de fils de bobinage - für bestimmte Typen von Wickeldrähten -
Partie 43: Fil de section circulaire Teil 43: Runddrähte aus Kupfer, mit Band
en cuivre recouvert d'un ruban aus aromatischem Polyimid umwickelt,
de polyimide aromatique, classe 240 Klasse 240
(CEI 60317-43:1997/A1:2010) (IEC 60317-43:1997/A1:2010)
This amendment A1 modifies the European Standard EN 60317-43:1997; it was approved by CENELEC on
2010-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60317-43:1997/A1:2010 E
Foreword
The text of document 55/1175/FDIS, future amendment 1 to IEC 660317-43:1997, prepared by
IEC TC 55, Winding wires, was submitted to the IEC-CENELEC parallel vote and was approved by
CENELEC as amendment A1 to EN 60317-43:1997 on 2010-04-01.
Attention is drawn to the possibility that some of the elements of this document may be the subjec
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...