Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass insulator units for AC systems - Characteristics of insulator units of the cap and pin type

IEC 60305:2021 applies to string insulator units of the cap and pin type with insulating parts of ceramic material or glass, intended for AC overhead lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to insulators of similar design used in substations. This document applies to string insulator units of the cap and pin type either with ball and socket couplings or with clevis and tongue couplings. This document applies to string insulator units for use on overhead lines in clean areas and polluted areas. For use in areas characterized by very heavy pollution levels and for other particular or extreme environmental conditions, it may be necessary for certain dimensions to be changed and insulator units having different creepage distances, spacing and forms may be preferred (for example, flat profile, hemispherical etc.). Insulators for use on DC systems may also need different dimensions. In any case, it is applicable that the standardized mechanical characteristics of this document and coupling sizes are retained. This fifth edition cancels and replaces the fourth edition published in 1995. This edition includes the following significant technical changes with respect to the previous edition: - wording in Scope changed from "it is recommended" to "it is applicable"; - new normative references added; - electromechanical or mechanical failing load in Clause 4 specified; - new figures added showing profiles.

Isolatoren für Freileitungen mit einer Nennspannung über 1 000 V - Keramik- oder Glas-Kettenisolatoren für Wechselstromsysteme - Kenngrößen von Kettenisolatoren vom Typ Kappenisolator

Isolateurs pour lignes aériennes de tension nominale supérieure a 1 000 V - Éléments d’isolateurs en céramique ou en verre pour réseaux à tension alternative - Caractéristiques des éléments d'isolateurs du type capot et tige

L'IEC 60305:2021 s'applique aux éléments de chaînes d'isolateurs du type à capot et tige ayant des parties isolantes en matière céramique ou en verre et destinés aux lignes aériennes fonctionnant en courant alternatif à une tension nominale supérieure à 1 000 V et à une fréquence au plus égale à 100 Hz. Elle s'applique également aux isolateurs du même type utilisés dans les postes. Le présent document s'applique aux éléments de chaînes d'isolateurs du type à capot et tige soit avec assemblage à rotule, soit avec assemblage à chape et tenon. Le présent document s'applique aux éléments de chaînes d'isolateurs destinés aux lignes aériennes situées dans des régions polluées et non polluées. Pour les isolateurs destinés à être utilisés dans des régions très fortement polluées et dans d'autres conditions environnementales particulières ou extrêmes, il peut être nécessaire de modifier certaines dimensions et il peut être préférable d'utiliser des éléments d'isolateurs ayant des lignes de fuite, des pas et des formes différentes (par exemple, profil plat, hémisphérique, etc.). Les isolateurs destinés à être utilisés sur les réseaux à tension continue peuvent également nécessiter des dimensions différentes. Dans tous les cas, il est possible de retenir les caractéristiques mécaniques normalisées du présent document et les dimensions d'assemblage. Cette cinquième édition annule et remplace la quatrième édition parue en 1995. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: - reformulation du domaine d'application: "il est recommandé d’utiliser" a été remplacé par "il est possible de retenir"; - ajout de nouvelles références normatives; - spécification à l'Article 4 de la charge de rupture électromécanique ou mécanique; - ajout de nouvelles figures représentant des profils.

Izolatorji za nadzemne vode za nazivne napetosti nad 1000 V - Keramični ali stekleni izolatorski členi za izmenične sisteme - Karakteristike izolatorskih členov za kapaste izolatorje (IEC 60305:2021)

General Information

Status
Published
Publication Date
25-Feb-2021
Current Stage
6060 - Document made available - Publishing
Start Date
26-Feb-2021
Completion Date
26-Feb-2021

Relations

Buy Standard

Standard
EN IEC 60305:2021
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2021
Nadomešča:
SIST EN 60305:1997
Izolatorji za nadzemne vode za nazivne napetosti nad 1000 V - Keramični ali
stekleni izolatorski členi za izmenične sisteme - Karakteristike izolatorskih členov
za kapaste izolatorje (IEC 60305:2021)
Insulators for overhead lines with a nominal voltage above 1000 V - Ceramic or glass
insulator units for AC systems - Characteristics of insulator units of the cap and pin type
(IEC 60305:2021)
Isolatoren für Freileitungen mit einer Nennspannung über 1000 V – Keramik- oder Glas-
Kettenisolatoren für Wechselstromsysteme – Kenngrößen von Kettenisolatoren vom Typ
Kappenisolator (IEC 60305:2021)
Isolateurs pour lignes aériennes de tension nominale supérieure à 1000 V - Eléments
d'isolateurs en matière céramique ou en verre pour systèmes à courant alternatif -
Caractéristiques des éléments d'isolateurs du type capot et tige (IEC 60305:2021)
Ta slovenski standard je istoveten z: EN IEC 60305:2021
ICS:
29.080.10 Izolatorji Insulators
29.240.20 Daljnovodi Power transmission and
distribution lines
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 60305

NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2021
ICS 29.080.10; 29.240.20 Supersedes EN 60305:1996 and all of its amendments
and corrigenda (if any)
English Version
Insulators for overhead lines with a nominal voltage above
1 000 V - Ceramic or glass insulator units for AC systems -
Characteristics of insulator units of the cap and pin type
(IEC 60305:2021)
Isolateurs pour lignes aériennes de tension nominale  Isolatoren für Freileitungen mit einer Nennspannung über
supérieure a 1 000 V - Éléments d'isolateurs en céramique 1000 V – Keramik- oder Glas-Kettenisolatoren für
ou en verre pour réseaux à tension alternative - Wechselstromsysteme – Kenngrößen von Kettenisolatoren
Caractéristiques des éléments d'isolateurs du type capot et vom Typ Kappenisolator
tige (IEC 60305:2021)
(IEC 60305:2021)
This European Standard was approved by CENELEC on 2021-02-15. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2021 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 60305:2021 E
European foreword
The text of document 36/499/FDIS, future edition 5 of IEC 60305, prepared by IEC/TC 36 "Insulators"
was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-11-15
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2024-02-15
document have to be withdrawn
This document supersedes EN 60305:1996 and all of its amendments and corrigenda (if any).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 60305:2021 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 60120:2020 NOTE Harmonized as EN IEC 60120:2020 (not modified)
IEC 60471:2020 NOTE Harmonized as EN IEC 60471:2020 (not modified)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the
relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60383-1 - Insulators for overhead lines with a EN 60383-1 -
nominal voltage above 1000 V - Part 1:
Ceramic or glass insulator units for a.c.
systems - Definitions, test methods and
acceptance criteria
IEC 60305 ®
Edition 5.0 2021-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Insulators for overhead lines with a nominal voltage above 1 000 V – Ceramic or

glass insulator units for AC systems – Characteristics of insulator units of the

cap and pin type
Isolateurs pour lignes aériennes de tension nominale supérieure a 1 000 V –

Éléments d’isolateurs en céramique ou en verre pour réseaux à tension

alternative – Caractéristiques des éléments d'isolateurs du type capot et tige

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.080.10; 29.240.20 ISBN 978-2-8322-9203-7

– 2 – IEC 60305:2021 © IEC 2021
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Mechanical characteristics, dimensions and types . 6
5 Designation and marking with respect to shed profile . 6
6 Tolerances . 8
Bibliography . 14

Figure 1 – Typical "standard" profile . 7
Figure 2 – Typical "anti-fog" profile "P" . 7
Figure 3 – Typical "aerodynamic" profile "D" . 7
Figure 4 – Typical "two-alternating" profile "V" . 7
Figure 5 – Typical "three-alternating" profile "T" . 8
Figure 6 – String insulator unit of standard and anti-fog profile with ball and socket
coupling . 8
Figure 7 – String insulator unit of standard and anti-fog profile with clevis and tongue
coupling . 10
Figure 8 – String insulator unit of aerodynamic profile with ball and socket coupling . 11
Figure 9 – String insulator unit of two-alternating profile with ball and socket coupling . 11
Figure 10 – String insulator unit of three-alternating profile with ball and socket
coupling . 12

Table 1 – Specified values of mechanical and dimensional characteristics for string
insulator units of standard and anti-fog profile with ball and socket couplings . 9
Table 2 – Specified values of mechanical and dimensional characteristics for string
insulator units of standard and anti-fog profile with clevis and tongue couplings . 10
Table 3 – Specified values of mechanical and dimensional characteristics for string
insulator units of aerodynamic profile with ball and socket couplings . 11
Table 4 – Specified values of mechanical and dimensional characteristics for string
insulator units of two-alternating profile with ball and socket couplings . 12
Table 5 – Specified values of mechanical and dimensional characteristics for string
insulator units of three-alternating profile with ball and socket couplings . 13

IEC 60305:2021 © IEC 2021 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
INSULATORS FOR OVERHEAD LINES WITH
A NOMINAL VOLTAGE ABOVE 1 000 V –
CERAMIC OR GLASS INSULATOR UNITS FOR AC SYSTEMS –
CHARACTERISTICS OF INSULATOR UNITS OF THE CAP AND PIN TYPE

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC
Publication(s)"). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60305 has been prepared by IEC technical committee 36:
Insulators.
This fifth edition cancels and replaces the fourth edition published in 1995. This edition
constitutes a technical revision.
This edition includes the following significant technical changes w
...