(Main)Water meters for cold potable water and hot water - Part 5: Installation requirements (ISO/DIS 4064-5:2023)
Water meters for cold potable water and hot water - Part 5: Installation requirements (ISO/DIS 4064-5:2023)
ISO 4064-5:2014 applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.
ISO 4064-5:2014 specifies criteria for the selection of single, combination and concentric water meters, associated fittings, installation, special requirements for meters, and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter.
In addition to meters based on mechanical principles, ISO 4064-5:2014 also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. It also applies to electronic ancillary devices. Ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.
The recommendations of ISO 4064-5:2014 apply to water meters, irrespective of technology, defined as integrating measuring instruments continuously determining the volume of water flowing through them.
Wasserzähler zum Messen von kaltem Trinkwasser und heißem Wasser - Teil 5: Einbaubedingungen (ISO/DIS 4064-5:2023)
Der vorliegende Teil der ISO 4064 gilt für Wasserzähler zur Volumenmessung von kaltem Trinkwasser und heißem Wasser, das durch eine vollständig gefüllte, geschlossene Leitung fließt. Diese Wasserzähler sind mit Einrichtungen versehen, die das kumulierte Volumen anzeigen.
Der vorliegende Teil der ISO 4064 legt Kriterien für die Auswahl von einzelnen Wasserzählern, Verbundzählern und konzentrischen Wasserzählern, zugehörigen Armaturen, den Einbau, besondere Anforderungen an Zähler und die Inbetriebnahme von neuen oder reparierten Zählern fest, um eine genaue konstante Messung und zuverlässige Ablesung der Zähler sicherzustellen.
Zusätzlich zu den auf mechanischen Funktionsprinzipien beruhenden Wasserzählern gilt der vorliegende Teil der ISO 4064 ebenfalls für Wasserzähler, die auf elektrischen oder elektronischen Funktionsprinzipien beruhen, und für Wasserzähler nach mechanischem Funktionsprinzip mit elektronischen Einrichtungen, die zur Messung des Volumens von kaltem Trinkwasser und heißem Wasser dienen. Er gilt außerdem für elektronische Zusatzeinrichtungen. Zusatzeinrichtungen sind optional. In nationalen oder internationalen Vorschriften können allerdings einige Zusatzeinrichtungen hinsichtlich der Verwendung von Wasserzählern verbindlich vorgeschrieben sein.
Die Empfehlungen dieses Teils der ISO 4064 gelten für Wasserzähler unabhängig von der Technologie, die als integrierende Messgeräte das Volumen des sie durchlaufenden Wassers bestimmen.
ANMERKUNG Im Verwendungsland gilt die nationale Gesetzgebung.
Compteurs d'eau potable froide et d'eau chaude - Partie 5: Exigences d'installation (ISO/DIS 4064-5:2023)
L'ISO 4064-5:2013 s'applique aux compteurs d'eau utilisés pour mesurer le volume d'eau potable froide et d'eau chaude s'écoulant dans une conduite fermée et à pleine charge. Ces compteurs d'eau comportent des dispositifs indiquant le volume compté.
L'ISO 4064-5:2013 spécifie des critères pour le choix de compteurs d'eau individuels, combinés et concentriques, les accessoires associés, l'installation ainsi que des exigences spéciales pour la première mise en service de compteurs neufs ou réparés pour garantir un mesurage d'une exactitude constante et une lecture fiable du compteur.
En plus des compteurs dont le fonctionnement est basé sur des principes mécaniques, l'ISO 4064-5:2013 s'applique aussi aux compteurs d'eau dont le fonctionnement est basé sur un principe électrique ou électronique, ainsi qu'aux compteurs d'eau à fonctionnement mécanique incluant des dispositifs électroniques utilisés pour mesurer le volume débité d'eau chaude et d'eau potable froide. Elle s'applique également aux dispositifs électroniques auxiliaires. Les dispositifs auxiliaires sont facultatifs. Cependant, des réglementations nationales ou internationales peuvent rendre certains dispositifs auxiliaires obligatoires selon l'utilisation du compteur d'eau.
Les recommandations de l'ISO 4064-5:2013 s'appliquent aux compteurs d'eau, indépendamment de leur technologie, définis en tant qu'instruments de mesure totalisateurs de débit, déterminant de manière continue le volume de débit d'eau les traversant.
Vodomeri za merjenje hladne pitne vode in vroče vode - 5. del: Zahteve za vgradnjo (ISO/DIS 4064-5:2023)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2023
Vodomeri za merjenje hladne pitne vode in vroče vode - 5. del: Zahteve za
vgradnjo (ISO/DIS 4064-5:2023)
Water meters for cold potable water and hot water - Part 5: Installation requirements
(ISO/DIS 4064-5:2023)
Wasserzähler zum Messen von kaltem Trinkwasser und heißem Wasser - Teil 5:
Einbaubedingungen (ISO/DIS 4064-5:2023)
Compteurs d'eau potable froide et d'eau chaude - Partie 5: Exigences d'installation
(ISO/DIS 4064-5:2023)
Ta slovenski standard je istoveten z: prEN ISO 4064-5
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
91.140.60 Sistemi za oskrbo z vodo Water supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT INTERNATIONAL STANDARD
ISO/DIS 4064-5
ISO/TC 30/SC 7 Secretariat: BSI
Voting begins on: Voting terminates on:
2023-10-13 2024-01-05
Water meters for cold potable water and hot water —
Part 5:
Installation requirements
Compteurs d'eau potable froide et d'eau chaude —
Partie 5: Exigences d'installation
ICS: 91.140.60
This document is circulated as received from the committee secretariat.
THIS DOCUMENT IS A DRAFT CIRCULATED
FOR COMMENT AND APPROVAL. IT IS
ISO/CEN PARALLEL PROCESSING
THEREFORE SUBJECT TO CHANGE AND MAY
NOT BE REFERRED TO AS AN INTERNATIONAL
STANDARD UNTIL PUBLISHED AS SUCH.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
USER PURPOSES, DRAFT INTERNATIONAL
STANDARDS MAY ON OCCASION HAVE TO
BE CONSIDERED IN THE LIGHT OF THEIR
POTENTIAL TO BECOME STANDARDS TO
WHICH REFERENCE MAY BE MADE IN
Reference number
NATIONAL REGULATIONS.
ISO/DIS 4064-5:2023(E)
RECIPIENTS OF THIS DRAFT ARE INVITED
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
PROVIDE SUPPORTING DOCUMENTATION. © ISO 2023
ISO/DIS 4064-5:2023(E)
DRAFT INTERNATIONAL STANDARD
ISO/DIS 4064-5
ISO/TC 30/SC 7 Secretariat: BSI
Voting begins on: Voting terminates on:
Water meters for cold potable water and hot water —
Part 5:
Installation requirements
Compteurs d'eau potable froide et d'eau chaude —
Partie 5: Exigences d'installation
ICS: 91.140.60
This document is circulated as received from the committee secretariat.
THIS DOCUMENT IS A DRAFT CIRCULATED
FOR COMMENT AND APPROVAL. IT IS
© ISO 2023
ISO/CEN PARALLEL PROCESSING
THEREFORE SUBJECT TO CHANGE AND MAY
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
NOT BE REFERRED TO AS AN INTERNATIONAL
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on STANDARD UNTIL PUBLISHED AS SUCH.
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
IN ADDITION TO THEIR EVALUATION AS
or ISO’s member body in the country of the requester. BEING ACCEPTABLE FOR INDUSTRIAL,
TECHNOLOGICAL, COMMERCIAL AND
ISO copyright office
USER PURPOSES, DRAFT INTERNATIONAL
CP 401 • Ch. de Blandonnet 8
STANDARDS MAY ON OCCASION HAVE TO
BE CONSIDERED IN THE LIGHT OF THEIR
CH-1214 Vernier, Geneva
POTENTIAL TO BECOME STANDARDS TO
Phone: +41 22 749 01 11
WHICH REFERENCE MAY BE MADE IN
Reference number
Email: copyright@iso.org
NATIONAL REGULATIONS.
Website: www.iso.org ISO/DIS 4064-5:2023(E)
RECIPIENTS OF THIS DRAFT ARE INVITED
Published in Switzerland
TO SUBMIT, WITH THEIR COMMENTS,
NOTIFICATION OF ANY RELEVANT PATENT
RIGHTS OF WHICH THEY ARE AWARE AND TO
ii
PROVIDE SUPPORTING DOCUMENTATION. © ISO 2023
ISO/DIS 4064-5:2023(E)
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Criteria for the selection of water meters . 2
4.1 General considerations. 2
4.2 Information to be provided by the manufacturer . 2
4.3 Meters operating in parallel or in a group . 3
5 Associated fittings. 3
5.1 General . 3
5.2 Upstream of the meter . 3
5.3 Downstream of the meter. 3
6 Installation .4
6.1 General requirements . 4
6.2 Installation requirements . 4
6.3 Water quality (suspended particles) . 5
6.4 Electromagnetic meters . 5
6.5 Meters operating in parallel or in a group . 5
6.6 Security of operation . 5
7 Hydraulic disturbances .6
7.1 General considerations. 6
7.2 Methods to eliminate disturbances . 6
8 First operation of new or repaired water meters . 7
8.1 General considerations. 7
8.2 Meters operating in parallel or in a group . 7
8.3 Protection of the meter . 7
8.3.1 Frost . 7
8.3.2 Reverse water flow . 7
8.3.3 Intentional fraud . 8
8.3.4 Cartridge meters . 8
8.3.5 Meters with exchangeable metrological modules . 9
8.4 Safety of personnel and users . 10
8.4.1 General . 10
8.4.2 Manhole installation . 10
8.4.3 Installation requirements for pipes greater than DN 40 . 10
8.4.4 Protection against hazard related to electrical installations . 10
8.5 Comfort of personnel — Access to the water meter and fittings . 11
8.5.1 General considerations . 11
8.5.2 Installation in manholes . 11
Bibliography .12
iii
ISO/DIS 4064-5:2023(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2, www.iso.org/directives.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received, www.iso.org/patents.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
The committee responsible for this document is ISO/TC 30, Measurement of fluid flow in closed conduits,
Subcommittee SC 7, Volume methods including water meters. It supersedes ISO 4064-2:2005, which has
been technically revised.
ISO 4064 consists of the following parts, under the general title Water meters for cold potable water and
hot water:
— Part 1: Metrological and technical requirements
— Part 2: Test methods
— Part 3: Test report format
— Part 4: Non-metrological requirements not covered in ISO 4064-1
— Part 5: Installation requirements
iv
DRAFT INTERNATIONAL STANDARD ISO/DIS 4064-5:2023(E)
Water meters for cold potable water and hot water —
Part 5:
Installation requirements
1 Scope
This part of ISO 4064 applies to water meters used to meter the volume of cold potable water and hot
water flowing through a fully charged, closed conduit. These water meters incorporate devices which
indicate the integrated volume.
This part of ISO 4064 specifies criteria for the selection of single, combination and concentric water
meters, associated fittings, installation, special requirements for meters, and the first operation of new
or repaired meters to ensure accurate constant measurement and reliable reading of the meter.
In addition to meters based on mechanical principles, this part of ISO 4064 also applies to water
meters based on electrical or electronic principles, and to water meters based on mechanical principles
incorporating electronic devices, used to measure the volume of cold potable water and hot water.
It also applies to electronic ancillary d
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.