Foodstuffs - Determination of trace elements - Determination of sodium and magnesium by flame atomic absorption spectrometry (AAS) after microwave digestion

This document specifies methods for the determination of sodium and magnesium in foodstuffs by flame atomic absorption spectrometry (AAS) after microwave digestion. Collaborative studies have been carried out (Annex A). The method is suitable for the determination of sodium not less than 1 500 mg/kg and magnesium not less than 250 mg/kg. Data for calcium is included for information (Annex B). The method is not applicable to wheat bran.

Lebensmittel - Bestimmung von Elementspuren - Bestimmung von Natrium und Magnesium mit Flammen-Atomabsorptionsspektrometrie (AAS) nach Mikrowellenaufschluss

Dieses Dokument legt Verfahren zur Bestimmung von Natrium und Magnesium in Lebensmitteln mit
Flammen-Atomabsorptionsspektrometrie (AAS) nach Mikrowellenaufschluss fest. Ringversuche wurden
durchgeführt (Anhang A). Das Verfahren ist für die Bestimmung von Natrium bei einer Konzentration von
mindestens 1 500 mg/kg Trockensubstanz und Magnesium von mindestens 250 mg/kg Trockensubstanz
geeignet. Zur Information sind Daten für Calcium enthalten (Anhang B). Das Verfahren ist nicht auf
Weizenkleie anwendbar.

Produits alimentaires - Dosage des éléments traces - Dosage du sodium et du magnésium par spectrométrie d'absorption atomique de flamme après digestion par micro-ondes

Le présent document prescrit des méthodes de dosage du sodium et du magnésium dans les produits
alimentaires par spectrométrie d’absorption atomique de flamme après digestion par micro-ondes. Des études
conjointes ont été réalisées (Annexe A). La méthode convient pour le dosage du sodium et du magnésium,
avec une teneur respective en matière sèche au moins égale à 1 500 mg/kg et 250 mg/kg. Les données
concernant le calcium sont incluses pour information (Annexe B). La méthode n’est pas applicable au son de
blé.

Živila - Določevanje elementov v sledovih - Določevanje natrija in magnezija z uporabo spektrometrije s plamensko atomsko absorpcijo (AAS) po mikrovalovnem razklopu

General Information

Status
Published
Publication Date
04-Mar-2008
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
17-Sep-2024
Completion Date
14-Apr-2025
Standard
EN 15505:2009
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.NURYDORYQHPUD]NORSXLebensmittel - Bestimmung von Elementspuren - Bestimmung von Natrium und Magnesium mit Flammen-Atomabsorptionsspektrometrie (AAS) nach MikrowellenaufschlussProduits alimentaires - Dosage des éléments traces - Dosage du sodium et du magnésium par spectrométrie d'absorption atomique de flamme après digestion par micro-ondesFoodstuffs - Determination of trace elements - Determination of sodium and magnesium by flame atomic absorption spectrometry (AAS) after microwave digestion67.050Splošne preskusne in analizne metode za živilske proizvodeGeneral methods of tests and analysis for food productsICS:Ta slovenski standard je istoveten z:EN 15505:2008SIST EN 15505:2009en,fr,de01-april-2009SIST EN 15505:2009SLOVENSKI
STANDARD
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15505March 2008ICS 67.050 English VersionFoodstuffs - Determination of trace elements - Determination ofsodium and magnesium by flame atomic absorptionspectrometry (AAS) after microwave digestionProduits alimentaires - Dosage des éléments traces -Dosage du sodium et du magnésium par spectrométried'absorption atomique de flamme après digestion parmicro-ondesLebensmittel - Bestimmung von Elementspuren -Bestimmung von Natrium und Magnesium mit Flammen-Atomabsorptionsspektrometrie (AAS) nachMikrowellenaufschlussThis European Standard was approved by CEN on 7 February 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15505:2008: ESIST EN 15505:2009

Results of the inter-laboratory tests.9 Annex B (informative)
Additional information on calcium.12 Bibliography.15
WARNING — The use of this standard may involve hazardous materials, operations and equipment. This standard does not purport to address all the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 4 Reagents 4.1 General Use only reagents and water, which shall have an element level low enough not to affect results. The use of certified stock solutions is advisable. 4.2 Nitric acid 4.2.1 Nitric acid, not less than 65 % of approximately mass concentration ρ(HNO3) = 1,4 g/ml.
In case of insufficient purity, it is necessary to purify the nitric acid in a distillation apparatus as described in EN 13805. 4.2.2 Diluted nitric acid solution 1, mass fraction w = 2,7 %
Dilute 42 ml nitric acid (4.2.1) to 1 000 ml with water. 4.2.3 Diluted nitric acid solution 2, mass fraction w = 0,65 %
Mix nitric acid (4.2.1) and water in a proportion minimum of 1 + 99 parts by volume. SIST EN 15505:2009

4.4 Hydrogen peroxide, mass fraction w = 30 % 4.5 Cesium chloride solution (CsCl), for use in AAS analysis Dissolve 31,75 g of cesium chloride in water and dilute to 250 ml. The solution will be stable in a refrigerator for at least 6 months. 4.6 Lanthanum(III)oxide (La2O3) solution, for use in AAS analysis, 5 % (weight/volume) Weigh 14,66 g of lanthanum(III)oxide into a 250 ml beaker, moisten with 10 ml of water and add 62,5 ml of HCl (4.3). Transfer to a 250 ml volumetric flask and fill up with water. The solution will be stable in a refrigerator for one month. 4.7 Sodium solution 4.7.1 Sodium stock solution, mass concentration ρ(Na) = 1 000 mg/l
4.7.2 Sodium standard solution, mass concentration ρ(Na) = 10 mg/l
Dilute 1 ml of sodium stock solution (4.7.1) to 100 ml in a volumetric flask with 2,7 % nitric acid (4.2.2). The solution will remain stable for one month at room temperature. 4.8 Magnesium solution 4.8.1 Magnesium stock solution, mass concentration ρ(Mg) = 1 000 mg/l 4.8.2 Magnesium standard solution, mass concentration ρ(Mg) = 10 mg/l
Dilute 1 ml of magnesium stock solution (4.8.1) to 100 ml in a volumetric flask with 0,65 % nitric acid (4.2.3). The solution will remain stable for one month at room temperature. SIST EN 15505:2009

6.3 Dilution Pipette a suitable volume of the sample solution, add 5 % La-solution (4.6) and dilute this volume with 0,65 % nitric acid (4.2.3) so that the final concentration of Mg is within the linear range of measurement of the elements. In this example, the following ranges are selected for the standard curves; for Mg, 0,05 mg/l to 0,4 mg/l. The lowest point may be lower, if required by the concentrations of the sample solutions. Add 5 % of La-solution (4.6) to a final mass fraction of La of 1 % (e.g. 2 ml 5 % is diluted to 10 ml). Pipette a suitable volume of the sample solution, add 1 ml of Cs-solution (4.5) and dilute this volume with 2,7 % nitric acid (4.2.2) so that the final concentration of Na is within the range of measurement of the element. In this example, the following range is selected for the standard curve: 0,1 mg/l to 1,0 mg/l. The lowest point may be lower required by concentration of the sample solution. SIST EN 15505:2009
...