Child care articles - Children’s bedguards for domestic use - Safety requirements and test methods

This document specifies safety requirements and test methods for children’s bedguards for domestic use intended for use with junior or adult beds.
These bedguards, when used in conjunction with a bed/mattress combination, are intended to prevent children aged between 18 months and 4 years from falling out of bed.
This document is not applicable to bedguards designed for adult use, or to bedguards which are an integral part of a bed, i.e. a permanent fixture not intended to be detached.
If the bedguard has several functions or can be converted into another function, the relevant European standard/s apply to it.

Artikel für Säuglinge und Kleinkinder - Sicherheitstechnische Anforderungen und Prüfverfahren für Kinderbettschutzgitter für den Wohnbereich

Dieses Dokument legt sicherheitstechnische Anforderungen und Prüfverfahren für Kinderbettschutzgitter für den Wohnbereich fest, die zur Verwendung in Betten für Kinder oder Erwachsene vorgesehen sind.
Diese Bettschutzgitter sollen in Verbindung mit einer Bett-Matratzen-Kombination verhindern, dass Kinder im Alter zwischen 18 Monaten und 4 Jahren aus dem Bett fallen.
Dieses Dokument gilt weder für Bettschutzgitter, die für Erwachsene bestimmt sind, noch für Bettschutzgitter, die ein fester Bestandteil des Bettes sind, d. h. eine dauerhafte Einrichtung, die nicht abgenommen werden kann.
Falls das Bettschutzgitter mehrere Funktionen aufweist oder für eine andere Funktion umgewandelt werden kann, gilt/gelten dafür jeweils die einschlägige(n) Europäische(n) Norm(en).

Articles de puériculture - Barrières de lit pour enfant à usage domestique - Exigences de sécurité et méthodes d’essai

Le présent document spécifie les exigences de sécurité et les méthodes d’essai pour les barrières de lit pour enfant à usage domestique destinées à être utilisées avec des lits d’enfant ou d’adulte.
Ces barrières de lit, lorsqu’elles sont utilisées avec une combinaison lit/matelas, sont destinées à empêcher les enfants de 18 mois à 4 ans de tomber du lit.
Le présent document n’est pas applicable aux barrières de lit conçues pour un usage par un adulte, ni aux barrières de lit qui font partie intégrante d’un lit, c’est-à-dire qui sont fixées de manière permanente et qui ne sont pas prévues pour être détachées.
Si la barrière de lit offre plusieurs fonctions ou peut être convertie en une autre fonction, la ou les Normes européennes pertinentes s’appliquent.

Izdelki za otroke - Varnostne ograje za otroške posteljice za domačo uporabo - Varnostne zahteve in preskusne metode

General Information

Status
Not Published
Publication Date
05-Dec-2023
Current Stage
4060 - Closure of enquiry - Enquiry
Start Date
05-Sep-2024
Due Date
11-Oct-2022
Completion Date
05-Sep-2024
Draft
prEN 18102:2024
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2024
Izdelki za otroke - Varnostne ograje za otroške posteljice za domačo uporabo -
Varnostne zahteve in preskusne metode
Child care articles - Children’s bedguards for domestic use - Safety requirements and
test methods
Artikel für Säuglinge und Kleinkinder - Sicherheitstechnische Anforderungen und
Prüfverfahren für Kinderbettschutzgitter für den Wohnbereich
Ta slovenski standard je istoveten z: prEN 18102
ICS:
97.140 Pohištvo Furniture
97.190 Otroška oprema Equipment for children
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2024
ICS 97.190
English Version
Child care articles - Children's bedguards for domestic use
- Safety requirements and test methods

This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 252.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 18102:2024 E
worldwide for CEN national Members.

Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Test equipment . 6
4.1 Tolerances . 6
4.2 Test surface . 6
4.3 Test mattress . 6
4.4 Small parts cylinder . 7
4.5 Test probes . 7
4.6 Ball chain loop and spherical mass . 7
4.7 Ball chain loop and spherical mass . 8
4.8 Test mass . 10
5 General requirements and test conditions . 10
5.1 Product conditioning . 10
5.2 Test conditions . 10
6 Chemical hazards . 10
6.1 General. 10
6.2 Migration of certain elements (see A.2) . 10
6.3 Formaldehyde (see A.2). 11
6.4 Colourants (see A.2) . 11
6.5 Aniline (see A.2) . 12
7 Thermal hazards . 12
7.1 Requirements . 12
7.2 Test method . 12
8 Mechanical hazards . 12
8.1 General. 12
8.2 Choking and ingestion hazards (see A.3.2) . 12
8.3 Suffocation hazards (see A.3.3) . 13
8.4 Entrapment hazards (see A.3.4) . 14
8.5 Hazards due to folding of the product (see A.3.5) . 15
8.6 Entanglement hazards (see A.3.6) . 16
8.7 Protrusion and projection hazards (see A.3.7) . 17
8.8 Hazardous edges (see A.3.8) . 17
8.9 Protective function (see A.3.9) . 17
8.10 Structural integrity (see A.3.10) . 17
9 Product information . 19
9.1 General. 19
9.2 Marking . 19
9.3 Purchase information. 19
9.4 Instructions for use . 20
Annex A (informative) Rationales . 22
A.1 General . 22
A.2 Chemical hazards (Clause 6). 22
A.3 Mechanical hazards (Clause 8) . 22
Annex ZA (informative) Relationship between this European Standard and the safety
requirements of Directive 2001/95/EC aimed to be covered . 24
Bibliography . 27
European foreword
This document (prEN 18102:2024) has been prepared by Technical Committee CEN/TC 252 “Child care
articles”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a standardization request addressed to CEN by the European
Commission. The Standing Committee of the EFTA States subsequently approves these requests for its
Member States.
For the relationship with EU Legislation, see informative Annex ZA, which is an integral part of this
document.
1 Scope
This document specifies safety requirements and test methods for children’s bedguards for domestic
use intended for use with junior or adult beds.
These bedguards, when used in conjunction with a bed/mattress combination, are intended to prevent
children aged between 18 months and 4 years from falling out of bed.
This document is not applicable to bedguards designed for adult use, or to bedguards which are an
integral part of a bed, i.e. a permanent fixture not intended to be detached.
If the bedguard has several functions or can be converted into another function, the relevant European
standard/s apply to it.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 71-2:2020, Safety of toys — Part 2: Flammability
EN 71-3:2019+A1:2021, Safety of toys — Part 3: Migration of certain elements
EN 71-10:2005, Safety of toys — Part 10: Organic chemical compounds — Sample preparation and
extraction
EN 71-11:2005, Safety of toys — Part 11: Organic chemical compounds — Methods of analysis
EN 622-1:2003, Fibreboards — Specifications — Part 1: General requirements
EN 717-1:2004, Wood-based panels — Determination of formaldehyde release — Part 1: Formaldehyde
emission by the chamber method
EN ISO 105-A03:2019, Textiles — Tests for colour fastness — Part A03: Grey scale for assessing staining
(ISO 105-A03:2019)
EN ISO 2439:2008, Flexible cellular polymeric materials — Determination of hardness (indentation
technique) (ISO 2439:2008)
EN ISO 14184-1:2011, Textiles — Determination of formaldehyde — Part 1: Free and hydrolysed
formaldehyde (water extraction method) (ISO 14184-1:2011)
EN ISO 14362-1:2017, Textiles — Methods for determination of certain aromatic amines derived from azo
colorants — Part 1: Detection of the use of certain azo colorants accessible with and without extracting
the fibres (ISO 14362-1:2017)
EN ISO 17234-1:2020, Leather — Chemical tests for the determination of certain azo colourants in dyed
leathers — Part 1: Determination of certain aromatic amines derived from azo colorants (ISO 17234-
1:2020)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at https://www.electropedia.org/
3.1
underframe
part of the bedguard which fits under the mattress
Note 1 to entry: The underframe is sometimes referred to as the “arm”, “leg” or “horizontal member”.
3.2
single-sided bedguard
bedguard with a vertical element on one side of the bed only, intended to fit against one long side of a
mattress
3.3
double-sided bedguard
bedguard with a vertical element on both sides of the bed, intended to fit against both long sides of a
mattress
4 Test equipment
4.1 Tolerances
Unless otherwise specified, the accuracy of the test equipment shall be:
a) Forces: ±5 % of the nominal force;
b) Masses: ±0,5 % of the nominal mass;
c) Dimensions: ±1 mm;
d) Angles: ±0,5°;
e) Time: ±1 s.
The tests are described in terms of the application of forces. Masses can however be used. The
relationship 10 N = 1 kg may be used for this purpose.
Unless otherwise specified, the test forces may be applied by any suitable device which does not
adversely affect the results.
4.2 Test surface
A smooth, hard surface, e.g. of medium-density fibreboard.
4.3 Test mattress
Mattress, of dimensions (1,900 ± 10) mm x (762 ± 10) mm x (150 ± 10) mm, made from flexible
polyether foam with a thickness of 100 mm, a density of (30 ± 2) kg/m and an indentation hardness
index of (170 ± 20) N in accordance with A40 in EN ISO 2439:2008. The size of the mattress shall be
such as to overlap the size of the loading pad by at least 100 mm all round.
The test mattress shall have a light, soft cotton cover with a mass not greater than 120 g/m .
4.4 Small parts cylinder
Small parts cylinder for the assessment of small components, having dimensions in accordance with
Figure 1.
Dimensions in millimetres
Figure 1 — Small parts cylinder
4.5 Test probes
Probes made from plastic or other hard, smooth material mounted on a force measuring device, one
0,1 0
each of diameters 45− mm and 65 mm with a rounded or conical end (see Figure 2).
+0 +0,1
Dimensions in millimetres
Figure 2 — Test probe
4.6 Ball chain loop and spherical mass
This equipment comprises a ball chain loop attached to a spherical mass at a common fixing point.
The ball chain comprises a maximum of 10 balls per 40 mm, equally distributed along the length of the
chain when the chain is loaded with a mass of 2,5 kg. See Figure 3.
The diameter of each ball is (3,2 ± 0,2) mm.
Dimensions in millimetres
Figure 3 — Ball chain
The ball chain loop is formed by the ball chain entering the spherical mass at a common fixing point
with a ball from each side of the chain in contact with each other. The external peripheral length of the
+5
ball chain loop shall be 400 mm. See Figure 4.
A smooth spherical mass of (2,5 ± 0,05) kg and a diameter of 115 mm.
Dimensions in millimetres
Key
1 ball chain loop
2 spherical mass
3 common fixing point
Figure 4 — Ball chain loop and spherical mass
4.7 Ball chain loop and spherical mass
4.7.1 Test probes with hemispherical end
0 +0,1
Probes made from plastic or other hard, smooth material of diameters 7 mm and 12 mm with a
−0,1 0
full hemispherical end that can be mounted on a force-measuring device, see Figure 5.
Dimensions in millimetres
Key
Probe type 7 mm probe 12 mm probe
Diameter A
0 +0,1
7 12
−0,1 0
Radius RB half of diameter A half of diameter A
1 Line ascribed around circumference showing depth of penetration
Figure 5 — Test probe with hemispherical end
4.7.2 Test probe for mesh with hemispherical end
Mesh probe made from plastic or other hard, smooth material as shown in Figure 6.
Dimensions in millimetres
Key
Diameter A
−0,1
Diameter B
5,6
−0,1
Radius RB half of diameter B
Figure 6 — Test probe for mesh
4.7.3 Shape assessment probe
Probe made from plastic or other hard, smooth material with the dimensions shown in Figure 7.
Dimensions in millimetres
Key
A front view
B top view
C side view
D 3D view
Figure 7 — Shape assessment probe
4.8 Test mass
Test mass B is a rigid cylinder (200 ± 5) mm in diameter and (300 ± 5) mm in height, having a mass of
+0,01
15 kg and with its centre of gravity in the centre of the cylinder. All edges shall have a radius of
(5 ± 1) mm.
5 General requirements and test conditions
5.1 Product conditioning
Before testing, any fabric used shall be cleaned or washed and dried twice in accordance with the
manufacturer’s instructions.
All samples shall be conditioned at a temperature of (23 ± 10) °C for at least 24 h prior to tests.
5.2 Test conditions
The test shall be carried out in ambient conditions of (23 ± 10) °C.
The tests are applied to bedguards that are fully assembled and ready for use according to the
manufacturer’s instructions.
6 Chemical hazards
6.1 General
If testing is required, a separate unconditioned sample shall be used for the tests in Clause 6.
6.2 Migration of certain elements (see A.2)
The migration of elements from materials on exterior surfaces shall comply with
EN 71-3:2019+A1:2021.
6.3 Formaldehyde (see A.2)
Accessible textile components shall not contain free and hydrolysed formaldehyde in excess of
30 mg/kg.
When testing is performed, the method described in EN ISO 14184-1:2011 shall be used.
Resin-bonded wood components shall not release formaldehyde in excess of 0,124 mg/m3 (class E1
according to EN 622-1:2003).
When testing is performed, the method described in EN 717-1:2004 shall be used.
6.4 Colourants (see A.2)
When tested in accordance with EN 71-10:2005, Annex A, if the colour fastness to sweat of textile
components is lower than 3-4 on the grey scale as defined in EN ISO 105-A03:2019, the part shall be
tested for colourants with the methods described in EN 71-10:2005 and EN 71-11:2005 and the limits
in Table 1 shall be fulfilled.
Table 1 — Colourants limits
Colour Index Generic Colour Index CAS Number Limit
Name (CIGN) Constitution Number
(CICN)
Disperse Blue 1 64500 2475–45–8 Action limit
Disperse Blue 3 61505 2475–46–9 Action limit
Disperse Blue 106 111935 12223–01–7 Action limit
Disperse Blue 124 111938 61951–51–7 Action limit
Disperse Yellow 3 11855 2832–40–8 Action limit
Disperse Orange 3 11855 730–40–5 Action limit
Disperse Orange 37/76/59 11132 12223–33–5 Action limit
13301–61–6
Disperse Red 1 11110 2872–52–8 Action limit
Solvent Yellow 1 11000 60–09–3 Action limit
Solvent Yellow 2 11020 60–11–7 Action limit
Solvent Yellow 3 11160 97–56–3 Action limit
Basic Red 9 42500 569–61–9 Action limit
Basic Violet 1 42535 8004–87–3 Action limit
Basic Violet 3 42555 548–62–9 Action limit
Acid Red 26 16150 3761–53–3 Action limit
Acid Violet 49 42640 1694–09–3 Action limit
6.5 Aniline (see A.2)
Aniline shall not exceed the limit of 30 mg/kg after reductive cleavage from textile components.
When testing is performed, the methods of EN ISO 14362-1:2017 and EN ISO 17234-1:2020, adapted as
appropriate to measure aniline, shall be used.
7 Thermal hazards
7.1 Requirements
When tested in accordance with 7.2, there shall be no surface flash and the rate of spread of flame shall
not exceed 50 mm/s.
A separate sample, conditioned according to 5.1, may be used for these tests.
7.2 Test method
To verify the surface flash effect, apply the test flame defined in EN 71-2:2020, 5.5 for (3 ± 0,5) s to the
bedguard in different places likely to cause surface flash.
To verify rate of spread of flame apply the test flame defined in EN 71-2:2020, 5.4.
8 Mechanical hazards
8.1 General
Connecting screws for direct fastening, e g self-tapping screws, shall not be used for the assembly of any
component that is designed to be removed or loosened when dismantling the bedguard for purposes of
transportation or storage.
8.2 Choking and ingestion hazards (see A.3.2)
8.2.1 Requirements
When tested in accordance with 8.2.2 any component or part of a component that is removed, whether
intended to be removed without the use of a tool or not, shall not fit entirely within the small parts
cylinder specified in 4.4.
Paper, fabric (including elastic fabric), yarn, string and fuzz are excluded from these requirements.
However, felt and tightly packed stuffed components made of fabric and/or yarn are not excluded from
these requirements.
8.2.2 Requirements
8.2.2.1 Assessment of child’s ability to grip components
A component is considered to be able to be gripped by a child if it can grip the component between its
thumb and forefinger or between its teeth.
Where it is difficult to assess whether a child can grip a component, establish whether it can be gripped
by inserting once the test probe specified in 4.5 between the component and the underlying layer or
body of the bedguard at an angle between 0° and 10° from the surface of the underlying layer or body of
the bedguard using a force of (10 ± 1) N. If the gauge can be inserted more than 2 mm, the component is
considered to be able to be gripped by the child.
8.2.2.2 Torque test
Apply a torque gradually to the component within a period of 5 s in a clockwise direction until either:
a) a rotation of 180° from the original position has been attained; or
b) a torque of 0,34 Nm is reached.
The maximum rotation or required torque shall be applied for (10 ± 1) s.
The component shall then be allowed to return to a relaxed condition and the procedure repeated in an
anticlockwise direction.
Where projections, components or assemblies are rigidly mounted on an accessible rod or shaft,
designed to rotate together with the projections, components or assemblies, during the test the rod or
shaft shall be clamped to prevent rotation.
If a component attached by a screw thread becomes loosened during application of the required torque,
the torque shall continue to be applied until the required torque is exceeded or the component
disassembles or it becomes apparent that the component will not disassemble.
When using clamps and test equipment, care shall be taken not to damage the attachment mechanism
or body of the component.
Check whether any component or part of a component that is removed during the test fits wholly in any
orientation, without compressing or manipulating it, within the small parts cylinder specified in 4.4.
8.2.2.3 Tensile test
The tensile test shall be carried out on the same components as the torque test.
Attach a suitable clamp to the component, taking care not to damage the attachment mechanism or
body of the component.
Fasten the component in a tensile testing machine and apply a tensile force of 90 N to the component to
be tested. Apply the force gradually within a period of 5 s and maintain for (10 ± 1) s.
Check whether any component or part of a component that is removed during the test fits wholly in any
orientation, without compressing or manipulating it, within the small parts cylinder specified in 4.4.
8.3 Suffocation hazards (see A.3.3)
8.3.1 Packaging
The rationale for this requirement is given in A.3.6.
Any plastic covering used for packaging with an area greater than 100 mm × 100 mm shall conform to
at least one of the following requirements:
a) have an average sheet thickness of 0,038 mm or more; or
b) be perforated with defined holes so that a minimum of 1 % of the area has been removed over any
area of 30 mm × 30 mm.
Any plastic covering used for packaging with an opening perimeter greater than 360 mm shall not have
a drawstring or cord as a means of closing and shall be marked in the official language(s) of the country
where the product is sold with the following statement:
“Keep plastic covering away from children to avoid suffocation”.
NOTE The statement can be expressed in different words providing they clearly convey the same message.
The text shall be accompanied by the symbol of the warning triangle ( ). The symbol, with a minimum
height of 1 cm, can be put on the top of the list of warnings when different languages are used.
8.4 Entrapment hazards (see A.3.4)
8.4.1 Head and neck entrapment
8.4.1.1 Requirements
a) Any gap between the underside of the lowest horizontal member on the vertical face of the bedguard
and the upper surface of t
...

Questions, Comments and Discussion