Chemicals used for treatment of water intended for human consumption - Chemicals for emergency use - Sodium dichloroisocyanurate, dihydrate

This European Standard is applicable to sodium dichloroisocyanurate dihydrate used for emergency treatment of water intended for human consumption. It describes the characteristics of sodium dichloroisocyanurate dihydrate and specifies the requirements and the corresponding test methods for sodium dichloroisocyanurate dihydrate. It gives information on its use in water treatment. It also determines the rules relating to safe handling and use of sodium dichloroisocyanurate dihydrate (see Annex B).

Produkte zur Aufbereitung von Wasser für den menschlichen Gebrauch - Produkte für den Notfall - Natriumdichlorisocyanurat-dihydrat

Diese Europäische Norm gilt für Natriumdichlorisocyanurat-dihydrat zur Aufbereitung von Wasser für den
menschlichen Gebrauch im Notfall. Sie beschreibt die Eigenschaften von Natriumdichlorisocyanurat-dihydrat
und legt die Anforderungen sowie die entsprechenden Prüfverfahren für Natriumdichlorisocyanurat-dihydrat
fest. Sie enthält Angaben zu dessen Anwendung in der Wasseraufbereitung. Sie legt darüber hinaus Regeln
für die sichere Handhabung und Verwendung von Natriumdichlorisocyanurat-dihydrat fest (siehe Anhang B).

Produits chimiques pour le traitement de l'eau destinée à la consommation humaine - Produits chimiques utilisés en cas d'urgence - Dichloroisocyanurate de sodium, dihydraté

La présente Norme européenne s’applique au dichloroisocyanurate de sodium dihydraté utilisé pour le traitement en cas d’urgence de l’eau destinée à la consommation humaine. Elle décrit les caractéristiques du dichloroisocyanurate de sodium dihydraté et spécifie les exigences et les méthodes d’essai correspondantes. Elle donne des informations pour son emploi dans le traitement de l’eau. Elle détermine également les règles relatives à la manipulation et à l’utilisation en toute sécurité du dichloroisocyanurate de sodium dihydraté (voir l’Annexe B).

Kemikalije, ki se uporabljajo za pripravo pitne vode - Kemikalije za uporabo v sili - Natrijev dikloroizociaourat, dehidriran

General Information

Status
Withdrawn
Publication Date
29-Jul-2008
Withdrawal Date
24-Mar-2015
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
25-Mar-2015

Relations

Buy Standard

Standard
EN 12932:2008
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kemikalije, ki se uporabljajo za pripravo pitne vode - Kemikalije za uporabo v sili - Natrijev dikloroizociaourat, dehidriranProdukte zur Aufbereitung von Wasser für den menschlichen Gebrauch - Produkte für den Notfall - Natriumdichlorisocyanurat-dihydratProduits chimiques pour le traitement de l'eau destinée à la consommation humaine - Produits chimiques utilisés en cas d'urgence - Dichloroisocyanurate de sodium, dihydratéChemicals used for treatment of water intended for human consumption - Chemicals for emergency use - Sodium dichloroisocyanurate, dihydrate71.100.80Chemicals for purification of water13.060.20Pitna vodaDrinking waterICS:Ta slovenski standard je istoveten z:EN 12932:2008SIST EN 12932:2008en,fr,de01-november-2008SIST EN 12932:2008SLOVENSKI
STANDARDSIST EN 12932:20001DGRPHãþD

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 12932July 2008ICS 71.100.80Supersedes EN 12932:2000
English VersionChemicals used for treatment of water intended for humanconsumption - Chemicals for emergency use - Sodiumdichloroisocyanurate, dihydrateProduits chimiques pour le traitement de l'eau destinée à laconsommation humaine - Produits chimiques utilisés encas d'urgence - Dichloroisocyanurate de sodium, dihydratéProdukte zur Aufbereitung von Wasser für denmenschlichen Gebrauch - Produkte für den Notfall -Natriumdichlorisocyanurat-dihydratThis European Standard was approved by CEN on 28 June 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12932:2008: ESIST EN 12932:2008

General information on sodium dichloroisocyanurate, dihydrate.19 Annex B (normative)
General rules relating to safety.21 Annex C (normative)
Determination of arsenic, antimony and selenium (atomic absorption spectrometry hydride technique).23 Bibliography.30
 Deletion of reference to EU Directive 80/778/EEC of July 15, 1980 in order to take into account the latest Directive in force (see [1]). Other amendments: a) section 3.1.2 – addition of “Troclosene sodium, dihydrate” as a synonym; b) section 4.3 – inclusion of the maximum admissible water content {14%}; c) section 5.2: 1) inclusion of section 5.2.2.1 Water; 2) change numbering of following section to
5.2.2.2 Sodium chloride; d) section 6.1 – inclusion of big bags as permitted means of delivery; e) section 6.2 – updating of risk and safety labelling according to EU directives (Annex I of the Directive 67/548EEC and its latest Adaptations to Technical Progress); 1) correction of hazard symbols {“N : Dangerous for the environment” instead of “O : Oxidizing”} 2) addition of R phrase:  R 50/53: Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment. 3) addition of S phrases:  S2: Keep out of the reach of children.  S 60: This material and its container must be disposed of as hazardous waste.  S 61: Avoid release to the environment. Refer to special instructions/safety data sheets. f) section 6.3 : SIST EN 12932:2008

1) Chemical Abstracts Service Registry Number. 2) European Inventory of Existing Commercial Chemical Substances. 3) 100 kPa = 1 bar SIST EN 12932:2008

Users of this product should check the national regulations in order to clarify whether it is of appropriate purity for treatment of water intended for human consumption, taking into account raw water quality, required dosage, contents of other impurities and additives used in the product not stated in this product standard. Limits have been given for impurities and chemical parameters where these are likely to be present in significant quantities from the current production process and raw materials. If the production process or raw materials lead to significant quantities of impurities, by-products or additives being present, this shall be notified to the user. 4.2 Composition of commercial product The product shall contain at least a mass fraction of 55 % of available chlorine as calculated in accordance with the corresponding method given in 5.2.1. 4.3 Impurities and main by-products The water content shall be less than a mass fraction of 14 % of the product. SIST EN 12932:2008

Limit mg/kg of product Element Type 1 Type 2 Arsenic (As) max. 10 10 Cadmium (Cd) max. 1 1 Chromium (Cr) max. 6 10 Mercury (Hg) max. 0,02 0,02 Nickel (Ni) max. 3 3 Lead (Pb) max. 4 4 Antimony (Sb) max. 5 5 Selenium (Se) max. 1 1 NOTE Cyanide, which does not exist in a strong oxidizing medium such as sodium dichloroisocyanurate, dihydrate, is not a relevant chemical parameter. Pesticides and polycyclic aromatic hydrocarbons are not by-products of the manufacturing process. For parametric values of sodium dichloroisocyanurate on trace metal content in drinking water, see [1]. 5 Test methods 5.1 Sampling Observe the general recommendations of ISO 3165 and take account of ISO 6206. Prepare the laboratory sample(s) required by the relevant procedure described in ISO 8213. 5.2 Analysis 5.2.1 Determination of available chlorine (main product) 5.2.1.1 Principle The available chlorine is determined by measuring active chlorine in the sample. The oxidizing chlorine reacts with potassium iodide releasing iodine which is then titrated with sodium thiosulfate standard volumetric solution in the presence of starch indicator solution. 5.2.1.2 Reagents All reagents shall be of a recognized analytical grade and the water used shall conform to grade 3 in accordance with EN ISO 3696. 5.2.1.2.1 Potassium iodide crystals (KI). 5.2.1.2.2 Glacial acetic acid. SIST EN 12932:2008

Alternatively a standard volumetric solution can be prepared by the following procedure: Dissolve 24,8 g Na2S2O3 . 5 H2O in a 1 000 ml one-mark volum
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.