Gullies for buildings - Part 6: Trapped floor gullies with a depth of water seal less than 50 mm

This document classifies floor gullies for domestic waste water for use inside buildings, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking of factory made gullies for buildings, irrespective of the material, for use in drainage systems requiring a trap with a depth of water seal less than 50 mm (referred to as floor gullies).
NOTE   Floor gullies with a depth of water seal less than 50 mm are not covered by EN 1253 1, EN 1253 7 and EN 1253 8.
These products are intended to be installed where the three following conditions are met:
-   space limitation will not accommodate a gully with a 50 mm water seal;
-   the building does not exceed a ground-floor and three floors above;
-   at least two domestic sanitary appliances are installed in addition to the gully but with only one WC on the same branch (connection pipe) or secondary or branch ventilation is installed (see EN 12056 2:2000, 4.3.2 or 4.3.4.

Abläufe für Gebäude - Teil 6: Bodenabläufe mit Geruchverschluss mit einer Sperrwasserhöhe von weniger als 50 mm

Dieses Dokument klassifiziert Bodenabläufe für häusliches Abwasser für den Einsatz innerhalb von Gebäuden, gibt eine Anleitung hinsichtlich der Einbaustellen und legt Anforderungen an die Konstruktion, Ausführung, Funktion und Kennzeichnung von werkmäßig hergestellten Abläufen für Gebäude, unabhängig vom Werkstoff, zur Verwendung in Entwässerungsanlagen, mit Geruchverschluss mit einer Sperwasserhöhe von weniger als 50 mm (im Folgenden als Bodenabläufe bezeichnet) fest.
ANMERKUNG   Bodenabläufe mit einer Sperrwasserhöhe von weniger als 50 mm werden in EN 1253 1, EN 1253 7 und EN 1253 8 nicht behandelt.
Diese Produkte sind für den Einbau unter den folgenden drei Bedingungen bestimmt:
—   aus Platzgründen kann kein Bodenablauf mit einer Sperrwasserhöhe von 50 mm untergebracht werden;
—   das Gebäude weist neben dem Erdgeschoss nicht mehr als drei Stockwerke auf;
—   mindestens zwei häusliche Entwässerungsgegenstände sind zusätzlich zum Bodenablauf installiert, wobei jedoch nur ein WC am gleichen Abzweig vorhanden ist (Verbindungsrohr), oder es ist eine sekundäre Belüftung bzw. Abzweigbelüftung installiert (siehe EN 12056 2:2000, 4.3.2 oder 4.3.4).

Avaloirs et siphons pour bâtiments - Partie 6 : Siphons de sol avec garde d’eau inférieure à 50 mm

Le présent document classifie les siphons de sol utilisés à l’intérieur des bâtiments pour les eaux usées domestiques, fournit des recommandations pour les lieux d’installation et spécifie les exigences concernant la construction, la conception, les performances et le marquage des siphons de sol pour bâtiments fabriqués en usine, indépendamment des matériaux, destinés à être utilisés dans les réseaux d’évacuation nécessitant un siphon de sol ayant une profondeur de garde d’eau inférieure à 50 mm (appelés « siphons de sol » dans le reste du document).
NOTE   Les siphons de sol ayant une profondeur de garde d’eau inférieure à 50 mm ne sont pas traités dans l’EN 1253 1, l’EN 1253 7 et l’EN 1253 8.
Ces produits sont destinés à être installés lorsque les trois conditions suivantes sont remplies :
-   l’installation d’un siphon de sol avec une garde d’eau de 50 mm est impossible pour des raisons d’encombrement ;
-   la hauteur du bâtiment ne dépasse pas un rez-de-chaussée surmonté de trois étages ;
-   au moins deux appareils sanitaires domestiques sont installés en plus du siphon de sol mais avec une seule toilette sur la même conduite de raccordement, ou lorsqu’une ventilation secondaire ou une ventilation de la conduite de raccordement est installée (voir l’EN 12056 2:2000, 4.3.2 ou 4.3.4).

Odtoki v stavbah - 6. del: Talni odtoki z zaporo vode na višini manj kot 50 mm

Ta dokument razvršča talne odtoke v stavbah, vsebuje napotke za mesta postavitve ter določa zahteve za gradnjo, projektiranje, učinkovitost in označevanje tovarniško izdelanih odtokov v stavbah, ne glede na material, za uporabo v drenažnih sistemih, pri katerih je potreben lovilnik z zaporo vode na višini manj kot 50 mm (imenovani talni odtoki).
Opomba: Talni odtoki z zaporo globine vode manj kot 50 mm niso zajeti v 1. delu, 7. delu, 8. delu.
Ti izdelki so namenjeni za namestitev samo na mestih:
– kjer zaradi prostorske omejitve ni mogoče namestiti talnega odtoka s 50-mm vodno zaporo;
– kjer stavba ne obsega več kot pritličja in treh nadstropij;
– kjer sta poleg talnega odtoka nameščeni vsaj dve sanitarni napravi, vendar le eno stranišče na istem kraku (priključna cev);
– ali kjer je sekundarno ali razvejeno prezračevanje nameščeno v skladu s točkama 4.3.2 ali 4.3.4 iz standarda EN 12056-2.

General Information

Status
Published
Publication Date
25-Oct-2022
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
26-Oct-2022
Due Date
20-Mar-2022
Completion Date
26-Oct-2022

Buy Standard

Standard
EN 1253-6:2023
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2023
Odtoki v stavbah - 6. del: Talni odtoki z zaporo vode na višini manj kot 50 mm
Gullies for buildings - Part 6: Trapped floor gullies with a depth of water seal less than 50
mm
Abläufe für Gebäude - Teil 6: Bodenabläufe mit Geruchverschluss mit einer
Geruchverschlusshöhe von weniger als 50 mm
Avaloirs et siphons pour bâtiments - Partie 6 : Siphons de sol avec garde d’eau inférieure
à 50 mm
Ta slovenski standard je istoveten z: EN 1253-6:2022
ICS:
91.140.80 Drenažni sistemi Drainage systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 1253-6
EUROPEAN STANDARD
NORME EUROPÉENNE
October 2022
EUROPÄISCHE NORM
ICS 91.140.80
English Version
Gullies for buildings - Part 6: Trapped floor gullies with a
depth of water seal less than 50 mm
Avaloirs et siphons pour bâtiments - Partie 6 : Siphons Abläufe für Gebäude - Teil 6: Bodenabläufe mit
de sol avec garde d'eau inférieure à 50 mm Geruchverschluss mit einer Geruchverschlusshöhe von
weniger als 50 mm
This European Standard was approved by CEN on 26 September 2022.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 1253-6:2022 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Design and construction . 8
4.1 General. 8
4.2 Appearance . 9
4.3 Aperture in gratings . 9
4.4 Resistance of trap in mechanical closure to pressure . 9
4.4.1 Requirements . 9
4.4.2 Test method . 9
4.5 Blockage prevention . 10
4.5.1 Access for cleaning . 10
4.5.2 Self-cleansing capacity . 11
4.5.3 Anti-blockage . 12
4.6 Places of installation . 12
4.7 Materials . 12
4.8 Thermal behaviour of floor gullies . 13
4.8.1 General. 13
4.8.2 Requirements . 13
4.8.3 Test method . 13
4.8.4 Additional test for floor gullies for use with sheet floor coverings and liquid applied
membranes . 13
4.9 Tightness . 14
4.9.1 Odour-tightness . 14
4.9.2 Watertightness of bodies . 16
4.9.3 Watertightness of extensions . 16
4.10 Mechanical strength . 16
4.10.1 Loading strength . 16
4.10.2 Clamping ring strength . 19
4.10.3 Additional mechanical strength according to the installation . 19
4.10.4 Floor gullies for use with liquid applied membranes . 23
4.11 Flow rates . 23
4.11.1 Requirements . 23
4.11.2 Test method . 24
4.11.3 Test arrangement . 24
5 Allocation and sequence of tests . 25
6 Marking . 27
7 Evaluation of conformity . 27
Annex A (normative) Examples of top view of the positioning of shape of test blocks applied
on the gratings . 28
Bibliography . 30
European foreword
This document (EN 1253-6:2022) has been prepared by Technical Committee CEN/TC 165 “Waste water
engineering”, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by April 2023, and conflicting national standards shall be
withdrawn at the latest by April 2023.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
Within its program of work, Technical Committee CEN/TC 165 requested CEN/TC 165/WG 11 “Gratings,
covers and other ancillary components for use inside buildings” to prepare the following standard:
EN 1253-6, Trapped floor gullies with a depth of water seal less than 50 mm.
The EN 1253 series under the main title Gullies for buildings will actually consist of the following parts:
— Part 1: Trapped floor gullies with a depth water seal of at least 50 mm;
— Part 2: Roof drains and floor gullies without trap;
— Part 3: Evaluation of conformity;
— Part 4: Access covers;
— Part 5: Gullies with light liquids closure;
— Part 6: Trapped floor gullies with a depth of water seal less than 50 mm;
— Part 7: Trapped floor gullies with mechanical closure;
— Part 8: Trapped floor gullies with combined mechanical closure and water seal.
Any feedback and questions on this document should be directed to the users’ national standards body.
A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia,
Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the United
Kingdom.
1 Scope
This document classifies floor gullies for domestic waste water for use inside buildings, gives guidance
for places of installation and specifies requirements for the construction, design, performance and
marking of factory made gullies for buildings, irrespective of the material, for use in drainage systems
requiring a trap with a depth of water seal less than 50 mm (referred to as floor gullies).
NOTE Floor gullies with a depth of water seal less than 50 mm are not covered by EN 1253-1, EN 1253-7 and
EN 1253-8.
These products are intended to be installed where the three following conditions are met:
— space limitation will not accommodate a gully with a 50 mm water seal;
— the building does not exceed a ground-floor and three floors above;
— at least two domestic sanitary appliances are installed in addition to the gully but with only one WC
on the same branch (connection pipe) or secondary or branch ventilation is installed (see
EN 12056-2:2000, 4.3.2 or 4.3.4.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 476, General requirements for components used in drains and sewers
EN 1253-3, Gullies for buildings — Part 3: Evaluation of conformity
EN 16323, Glossary of wastewater engineering terms
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 16323 and the following apply.
3.1
trapped floor gully
discharge fitting the top of which is a grating or cover capable of installation at ground or floor level,
intended to receive wastewater either through apertures in the grating and/or channels joined to the
body of the gully and to drain that wastewater through the outlet
Note 1 to entry: Four generic types of floor gullies are shown in Figure 1.
Note 2 to entry: In this document, the term “trapped floor gully” includes linear products, such as channel drains.
a) Floor gully with flange for bonding b) Floor gully with flange for clamping
waterproofing membranes (example) membranes (fixed and loose flange)
(example)
c) Floor gully with flange for clamping d) Channel drain with flange for bonding
flexible flooring (e.g. PVC flooring) (example) liquid applied membranes (example)
Key
1 finished floor 10 flange for bonding membranes
2 grating/cover 11 sediment bucket
3 extension 12 connecting flange with counter flange
4 trap a fixed flange
5 depth of water seal (H < 50 mm) b loose flange
6 outlet 13 flange for clamping flexible flooring with a clamping ring
7 body 14 seal
8 access for cleaning 15 flange for bonding liquid applied membrane
9 weep hole
Figure 1 — Examples of four generic types of floor gullies according to this standard
3.2
grating
removable component with apertures which permits the discharge of water
3.3
frame
support for a grating or cover which is connected to a body either directly or by means of a membrane
clamping ring or an extension
3.4
cover
removable part of an a
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.