Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the systems

This part of EN 1329 specifies the requirements for solid wall unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and the system intended for:
-   soil and waste discharge applications (low and high temperature) inside buildings (application area code "B");
-   soil and waste discharge applications (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD").
NOTE 1   The intended use is reflected in the marking of products by "B" or "BD".
NOTE 2   For use buried in ground within the building structure are intended only those components (marked with "BD") with nominal outside diameters equal to or greater than 75 mm.
This part of EN 1329 is also applicable to PVC-U pipes, fittings and the system intended for the following purposes:
-   ventilating part of the pipework in association with discharge applications;
-   rainwater pipework within the building structure.
It also specifies the test parameters for the test method referred to in this European Standard.
This European Standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
NOTE 3   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user.
NOTE 4   Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 24.
NOTE 5   Joints and adhesives are considered to be part of the system as covered in the scope.

Kunststoff-Rohrleitungssysteme zum Ableiten von Abwasser (niedriger und hoher Temperatur) innerhalb der Gebäudestruktur - Weichmacherfreies Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre, Formstücke und das Rohrleitungssystem

Systèmes de canalisations en plastique pour l'évacuation des eaux-vannes et des eaux usées (à basse et à haute température) à l'intérieur de la structure des bâtiments - Poly(chlorure de vinyle) non plastifié (PVC-U) - Partie 1 : Spécifications pour tubes, raccords et le système

Cevni sistemi iz polimernih materialov za (nizko- in visokotemperaturne) odvodne sisteme v zgradbah - Nemehčan polivinilklorid (PVC-U) - 1. del: Zahteve za cevi, fitinge in sistem

General Information

Status
Not Published
Current Stage
5060 - Closure of Vote - Formal Approval
Start Date
26-Oct-2017
Due Date
21-Jun-2018
Completion Date
26-Oct-2017

Relations

Effective Date
19-Jan-2023
Effective Date
25-Nov-2015

Overview

EN 1329-1:2014/FprA1 is a European standard developed by CEN that specifies the requirements for unplasticized poly(vinyl chloride) (PVC-U) plastic piping systems used for soil and waste discharge at both low and high temperatures within building structures. This standard applies to solid wall PVC-U pipes, fittings, and systems designed for applications inside buildings and, in some cases, buried within the building structure. It covers a range of nominal sizes, physical and mechanical characteristics, and includes provisions for marking and testing, ensuring reliable performance for soil and waste discharge systems.

Key Topics

  • Application Areas

    • Area B: Discharge applications inside buildings (soil and waste)
    • Area BD: Discharge applications both inside buildings and buried within the building structure, applicable for pipes with nominal outside diameters of 75 mm and above
  • Scope of Use

    • Soil and waste discharge piping for low and high temperature conditions
    • Ventilation parts of pipework associated with discharge systems
    • Rainwater pipework within the building structure
  • Product Marking and Identification

    • Pipes and fittings carry marked codes "B" or "BD" to indicate application suitability
    • Additional marking includes manufacturer’s name/trade mark, nominal diameter, wall thickness, material type (PVC or PVC-U), and for BD applications, the nominal ring stiffness (e.g., SN 4)
    • Special "ice crystal" symbol marking signifies suitability for cold climate performance and low-temperature impact resistance
  • Mechanical and Physical Requirements

    • Impact resistance tested at low temperatures using standard methods such as ISO 3127 and ISO 11173
    • Vicat softening temperature minimum of 79 °C ensures thermal performance (ISO 2507-1)
    • Longitudinal reversion and resistance to dichloromethane are tested to guarantee durability and chemical resistance
    • Tensile properties and gelation assessments are conducted to certify material quality and system integrity
  • Testing, Quality Control, and Conformity

    • Manufacturers are required to perform factory production control tests selecting appropriate test methods in alignment with national regulations and health and safety policies
    • The standard defines detailed test parameters and joint compatibility to ensure system performance and safety

Applications

EN 1329-1:2014/FprA1 piping systems are integral for modern building infrastructure where hygienic, durable, and efficient soil and waste discharge is critical. Common applications include:

  • Residential and Commercial Buildings
    Inside-building soil and waste discharge pipe networks that carry sewage and wastewater safely to sewer connections

  • Buried Piping within Building Structures
    Waterproof, robust discharge systems buried under floors or foundations with compliance to buried piping requirements

  • Ventilation Pipework
    Vent pipes connected to soil and waste discharge systems ensuring proper airflow and prevention of sewer gases

  • Rainwater Drainage Systems
    Internal rainwater piping that channels rainwater away from roofs and building facades safely

Use of this standard ensures compliance with European building codes, longevity of piping systems, and compatibility with other standardized components, leading to reliable wastewater management and environmentally sound building designs.

Related Standards

  • EN ISO 6259 Series – Testing tensile properties of plastic pipes
  • ISO 3127 – Low temperature impact testing procedures for plastics pipes
  • ISO 2507-1 – Determination of Vicat softening temperature for plastics
  • EN ISO 2505 – Longitudinal reversion tests for plastic pipes
  • ISO 9852 – Resistance testing to dichloromethane for PVC materials
  • CEN/TS 1329-2 – Guidance for factory production control for plastics piping systems

These related standards complement EN 1329-1:2014/FprA1 by providing harmonized test methods, ensuring comprehensive evaluation of PVC-U piping systems for soil and waste discharge applications.


Keywords: EN 1329-1, PVC-U pipes, soil and waste discharge, plastic piping systems, building drainage systems, low temperature impact resistance, plumbing standards, European plastic pipe specifications, wastewater piping, rainwater drainage, building plumbing standards.

Draft

EN 1329-1:2014/oprA1:2017

English language
6 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

EN 1329-1:2014/FprA1 is a draft published by the European Committee for Standardization (CEN). Its full title is "Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the systems". This standard covers: This part of EN 1329 specifies the requirements for solid wall unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and the system intended for: - soil and waste discharge applications (low and high temperature) inside buildings (application area code "B"); - soil and waste discharge applications (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD"). NOTE 1 The intended use is reflected in the marking of products by "B" or "BD". NOTE 2 For use buried in ground within the building structure are intended only those components (marked with "BD") with nominal outside diameters equal to or greater than 75 mm. This part of EN 1329 is also applicable to PVC-U pipes, fittings and the system intended for the following purposes: - ventilating part of the pipework in association with discharge applications; - rainwater pipework within the building structure. It also specifies the test parameters for the test method referred to in this European Standard. This European Standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 24. NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope.

This part of EN 1329 specifies the requirements for solid wall unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and the system intended for: - soil and waste discharge applications (low and high temperature) inside buildings (application area code "B"); - soil and waste discharge applications (low and high temperature) for both inside buildings and buried in ground within the building structure (application area code "BD"). NOTE 1 The intended use is reflected in the marking of products by "B" or "BD". NOTE 2 For use buried in ground within the building structure are intended only those components (marked with "BD") with nominal outside diameters equal to or greater than 75 mm. This part of EN 1329 is also applicable to PVC-U pipes, fittings and the system intended for the following purposes: - ventilating part of the pipework in association with discharge applications; - rainwater pipework within the building structure. It also specifies the test parameters for the test method referred to in this European Standard. This European Standard covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. For external above ground application additional requirements depending on the climate should be agreed between the manufacturer and the user. NOTE 4 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 24. NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope.

EN 1329-1:2014/FprA1 is classified under the following ICS (International Classification for Standards) categories: 23.040.01 - Pipeline components and pipelines in general; 91.140.80 - Drainage systems. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1329-1:2014/FprA1 has the following relationships with other standards: It is inter standard links to EN 1329-1:2014+A1:2018, EN 1329-1:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase EN 1329-1:2014/FprA1 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CEN standards.

Standards Content (Sample)


SLOVENSKI STANDARD
SIST EN 1329-1:2014/oprA1:2017
01-januar-2017
&HYQLVLVWHPLL]SROLPHUQLKPDWHULDORY]D QL]NRLQYLVRNRWHPSHUDWXUQH RGYRGQH
VLVWHPHY]JUDGEDK1HPHKþDQSROLYLQLONORULG 39&8 GHO=DKWHYH]DFHYL
ILWLQJHLQVLVWHP
Plastics piping systems for soil and waste discharge (low and high temperature) within
the building structure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications
for pipes, fittings and the system
Kunststoff-Rohrleitungssysteme zum Ableiten von Abwasser (niedriger und hoher
Temperatur) innerhalb der Gebäudestruktur - Weichmacherfreies Polyvinylchlorid (PVC-
U) - Teil 1: Anforderungen an Rohre, Formstücke und das Rohrleitungssystem
Ta slovenski standard je istoveten z: EN 1329-1:2014/prA1
ICS:
23.040.01 Deli cevovodov in cevovodi Pipeline components and
na splošno pipelines in general
91.140.80 Drenažni sistemi Drainage systems
SIST EN 1329-1:2014/oprA1:2017 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

SIST EN 1329-1:2014/oprA1:2017

SIST EN 1329-1:2014/oprA1:2017

DRAFT
EUROPEAN STANDARD
EN 1329-1:2014
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
November 2016
ICS 23.040.01; 91.140.80
English Version
Plastics piping systems for soil and waste discharge (low
and high temperature) within the building structure -
Unplasticized poly(vinyl chloride) (PVC-U) - Part 1:
Specifications for pipes, fittings and the systems
Systèmes de canalisations en plastique pour Kunststoff-Rohrleitungssysteme zum Ableiten von
l'évacuation des eaux-vannes et des eaux usées (à Abwasser (niedriger und hoher Temperatur) innerhalb
basse et à haute température) à l'intérieur de la der Gebäudestruktur - Weichmacherfreies
structure des bâtiments - Poly(chlorure de vinyle) Polyvinylchlorid (PVC-U) - Teil 1: Anforderungen an
(PVC-U) - Partie 1 : Spécifications pour tubes, raccords Rohre, Formstücke und das Rohrleitungssystem
et le système
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 155.

This draft amendment A1, if approved, will modify the European Standard EN 1329-1:2014. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 1329-1:2014/prA1:2016 E
worldwide for CEN national Members.

SIST EN 1329-1:2014/oprA1:2017
EN 1329-1:2014/prA1:2016 (E)
Contents
Page
1 General . 3
2 Modifications to 7.1.1, Table 18 . 4
3 Modifications to 7.1.2 . 5
4 Modifications to 8.1, Table 21. 5
5 Modifications to 12.2, Table 25 . 6

SIST EN 1329-1:
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.