Protective gloves against cold

This European Standard specifies the requirements and test methods for gloves which protect against convective and conductive cold down to –50 °C. This cold can be linked to the climatic conditions or an industrial activity. The specific values of the different performance levels are decided by the special requirements for each class of risk or the special areas of application. Product tests may only give performance levels and not levels of protection.

Schutzhandschuhe gegen Kälte

Diese Europäische Norm legt die Anforderungen und Prüfverfahren für Schutzhandschuhe gegen konvektive
Kälte oder Kontaktkälte bis - 50 °C fest. Die Kälte kann mit den klimatischen Bedingungen oder einer
beruflichen Tätigkeit zusammenhängen. Die spezifischen Werte der verschiedenen Leistungsstufen werden
durch die speziellen Anforderungen für jede Risikoklasse oder den speziellen Anwendungsbereich bestimmt.
Produktprüfungen können nur für Leistungsstufen und nicht für Schutzstufen erfolgen.

Gants de protection contre le froid

La présente Norme européenne définit les exigences et les méthodes d'essai des gants offrant une protection
contre le froid transmis par convection ou conduction jusqu'à - 50 °C. Ce froid peut être lié aux conditions
climatiques ou à une activité industrielle. Les valeurs spécifiques des différents niveaux de performance sont
déterminées d'après les exigences propres à chaque catégorie de risque ou à chaque domaine d'application
spécial. Les essais sur produits ne fournissent que des niveaux de performance et non des niveaux de
protection.

Rokavice za zaščito pred mrazom

General Information

Status
Published
Publication Date
25-Apr-2006
Current Stage
9060 - Closure of 2 Year Review Enquiry - Review Enquiry
Start Date
02-Dec-2021
Completion Date
02-Dec-2021

Relations

Effective Date
22-Dec-2008

Buy Standard

Standard
EN 511:2006
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Protective gloves against coldGants de protection contre le froidSchutzhandschuhe gegen KälteTa slovenski standard je istoveten z:EN 511:2006SIST EN 511:2006en13.340.40ICS:SIST EN 511:19961DGRPHãþDSLOVENSKI
STANDARDSIST EN 511:200601-julij-2006

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 511April 2006ICS 13.340.40Supersedes EN 511:1994
English VersionProtective gloves against coldGants de protection contre le froidSchutzhandschuhe gegen KälteThis European Standard was approved by CEN on 9 March 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 511:2006: E

Convective cold — Description of test apparatus.10 Annex B (informative)
Protection against cold according to the application.13 Annex C (informative)
Uncertainties of measurement and results interpretation.15 Annex D (informative)
Significant technical changes between this European Standard and the previous edition.16 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 89/686/EEC.17

1 Scope This European Standard specifies the requirements and test methods for gloves which protect against convective and conductive cold down to –50 °C. This cold can be linked to the climatic conditions or an industrial activity. The specific values of the different performance levels are decided by the special requirements for each class of risk or the special areas of application. Product tests may only give performance levels and not levels of protection. 2 Normative references The following referenced documents are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 388, Protective gloves against mechanical risks EN 420, Protective gloves — General requirements and test methods EN ISO 7854:1997, Rubber- or plastics-coated fabrics — Determination of resistance to damage by flexing (ISO 7854:1995) ISO 4675, Rubber- or plastics-coated fabrics — Low- temperature bend test ISO 5085-1, Textiles — Determination of thermal resistance — Part 1: Low thermal resistance ISO 7000, Graphical symbols for use on equipment — Index and synopsis ISO 15383, Protective gloves for firefighters — Laboratory test methods and performance requirements 3 General requirements These gloves shall meet all the applicable requirements of EN 420. 4 Performance requirements 4.1 Mechanical requirements The gloves shall at least comply with performance level 1 of EN 388 in abrasion and tear resistance. This minimum requirement can be different according to the levels of protection against cold (see 4.5 and 4.6). 4.2 Flexibility behaviour When tested in accordance with 5.2 there shall not be any cracks. This test is not necessary for uncoated materials. 4.3 Water penetration The gloves shall be tested according to 5.3. A level of performance of 1 shall be indicated when no leakage is seen at the end of the testing period. If this requirement is not passed, then a performance level of 0 shall be indicated, and a warning stating that the

For a convective cold performance level of 2 to 4, the product shall record at least level 2 in abrasion and tear resistance according to EN 388, otherwise the maximum convective cold performance that shall be reported is level 1. 4.6 Contact cold When tested in accordance with 5.6, the thermal resistance properties of the material shall comply with the values given in Table 2. Table 2 — Thermal resistance values Performance level Thermal resistance R in m2 K/W 1 0,025 ≤ R < 0,050 2 0,050 ≤ R < 0,100 3 0,100 ≤ R < 0,150 4 0,150 ≤ R
For a contact cold performance level of 2 to 4, the product shall record at least level 2 in abrasion and tear resistance according to EN 388, otherwise the maximum contact cold performance that shall be reported is level 1.

(23 ± 2) °C; relative humidity
(50 ± 5) %. The test shall be preferably carried out in this atmosphere. If the test is carried out under different climatic conditions then it should be started within 3 min of the time the samples were removed from the standard atmosphere. For protective gloves with a multi-layer construction the test shall be carried out on all layers simultaneously, even if these, when removed, are not connected to one another (see 5.5). 5.2 Flexibility behaviour The test shall be carried out in accordance with Method A of EN ISO 7854:1997 at a test temperature of (-20 ± 2) °C or an alternative temperature as specified by the glove's manufacturer.  The number of cycles shall be 10 000.  From each palm of a pair of protective gloves two samples shall be taken (four samples in total).  If the direction of manufacture of the material is recognizable then one sample shall be so taken that the longitudinal axis lies in the direction of the manufacture and one in the direction at right angles to it.  If the direction of manufacture is not given and one cannot be established then the two samples are taken in two directions at right angles to one another.  The samples are taken without seams. If this is not possible then the sample is taken in such a way that the seams lie, during the test, in the area of the clip and do not influence the bending. 5.3 Water penetration The test shall be carried out according to the whole glove integrity test described in ISO 15383, with complete immersion of the glove up to the wrist line only. 5.4 Extreme cold flexibility The test shall be carried out in accordance with ISO 4675 with a test temperature of (-50 ± 2) °C.  From each palm and back of a pair of gloves a sample will be taken (four samples in total).  If the direction of manufacture of the material is recognizable then one sample shall be taken so that the longitudinal axis lies in the direction of manufacture and one in the direction at right angles to it.  If the direction of manufacture is not given and one cannot be established then the two samples are taken in two directions at right angles to one another.

30 °C to 35 °C at an ambient temperature, which is at least 20 °C lower. 5.5.2 Apparatus The test apparatus consists of:  hand model;  climatic room;  measuring equipment. See Annex A. 5.5.3 Test sample The test sample shall be of size 9 (see EN 420). 5.5.4 Procedure The hand model is dressed with the test glove and placed vertically, fingers down in the test zone of the climatic room. The ambient temperature (TA) is set sufficiently low to meet the requirements of Annex A. The air velocity is kept at (4 ± 0,5) m/s and relative humidity (50 ± 5) %. Alternative conditions may be used provided correlation between the results obtained is demonstrated. When the temperature of the hand (THand) and power consumption (QHand) have reached a steady state, the measurements are taken of their average values for a period of 10 min. The resultant thermal insulation is calculated by: HandAHandTRQTTI−= TRI is the resistance to dry heat loss from the hand, which includes the resistance provided by the handwear and the air layer around the dressed model; THand is the mean surface temperature of the measuring zone of the hand, in °C; TA is the mean temperature of the air in the climatic room, in °C; QHand is the measured power supply to the measuring zone of the hand during steady state, in W/m2.

2 3 1
convective cold
contact cold
water penetration
Figure 1 The pictogram shall be used only if a minimum level of 1 is obtained for convective cold according to 4.5 or contact cold according to 4.6. The sign X, instead of a number, means that the glove is not designed for the use covered by the corresponding test. 7 Information supplied by the manufacturer The information supplied by the manufacturer shall be according to the appropriate clause of EN 420. If the glove consists of separate parts which are not permanently interconnected, the manufacturer shall indicate that the performance levels and the protection only apply to the complete assembly. The manufacturer shall provide information or indicate where information can be obtained on the maximum permissible user exposure, e.g. temperature, duration. Annex B may be used as a help. If the glove is not reaching a level of performance of 1 according to the water penetration test, then a warning stat
...