EN 2346-005:2017
(Main)Aerospace series - Cable, electrical, fire resistant - Operating temperatures between -65 °C and 260 °C - Part 005: DW family, single UV laser printable and multicore assembly - Light weight - Product standard
Aerospace series - Cable, electrical, fire resistant - Operating temperatures between -65 °C and 260 °C - Part 005: DW family, single UV laser printable and multicore assembly - Light weight - Product standard
This European Standard specifies the characteristics of light weight fire proof, unscreened, electrical cables for use in the on-board electrical systems of aircraft at operating temperature between - 65 °C and 260 °C.
This cable has not been demonstrated to be arc resistance at a.c.voltages above 200 V rms (network 115/200 V rms).
Single core is UV laser printable in accordance with EN 3838; UV laser markability is not mandatory for multicore cables.
Luft- und Raumfahrt - Feuerbeständige elektrische Leitungen - Betriebstemperaturen zwischen -65 °C und 260 °C - Teil 005: DW-Familie, einadrige, UV-Laser bedruckbar, und mehradrige Leitungen - Gewichtsoptimiert - Produktnorm
Diese Europäische Norm legt die Anforderungen an gewichtsoptimierte, feuerbeständige, ungeschirmte elektrische Leitungen zur Verwendung in elektrischen Bordnetzen von Luftfahrzeugen bei Betriebstemperaturen zwischen -65 °C und 260 °C fest.
Bei dieser Leitung konnte nicht nachgewiesen werden, dass sie bei Wechselspannungen von mehr als 200 V effektiv (Netzwerk 115/200 V effektiv) lichtbogenbeständig ist.
Einadrige Leitungen sind nach EN 3838 mit UV-Laser bedruckbar; die Kennzeichnung durch UV-Laser ist bei mehradrigen Leitungen nicht zwingend vorgeschrieben.
Série aérospatiale - Câbles électriques résistant au feu - Températures de fonctionnement comprises entre -65 °C et 260 °C - Partie 005 : Famille DW, fil simple marquable au laser UV et éléments assemblés - Version allégée - Norme de produit
Aeronavtika - Električni ognjevzdržni kabli - Delovne temperature med –65 °C in 260 °C - 005. del: Družina DW, snop enožilnih in večžilnih kablov z možnostjo UV-laserskega tiskanja - Lahki kabli - Standard za proizvod
Ta evropski standard določa lastnosti lahkih, ognjevzdržnih, neoklopljenih električnih
kablov za uporabo v električnih sistemih na krovu letala pri delovnih temperaturah od –65 °C do 260 °C.
Za ta kable ni bilo dokazano, da so odporni proti obloku pri napetosti 200 V AC RMS (omrežje
115/200 V RMS).
Snop enožilnih kablov ima možnost UV-laserskega tiskanja v skladu s standardom EN 3838. Označljivost z UV-laserjem ni obvezna za večžilne kable.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Luft- und Raumfahrt - Feuerbeständige elektrische Leitungen - Betriebstemperaturen zwischen -65 °C und 260 °C - Teil 005: DW-Familie, einadrige, UV-Laser bedruckbar, und mehradrige Leitungen - Gewichtsoptimiert - ProduktnormSérie aérospatiale - Câbles électriques résistant au feu - Températures de fonctionnement comprises entre -65 °C et 260 °C - Partie 005 : Famille DW, fil simple marquable au laser UV et éléments assemblés - Version allégée - Norme de produitAerospace series - Cable, electrical, fire resistant - Operating temperatures between -65 °C and 260 °C - Part 005: DW family, single UV laser printable and multicore assembly - Light weight - Product standard49.060Aerospace electric equipment and systems29.060.20KabliCablesICS:Ta slovenski standard je istoveten z:EN 2346-005:2017SIST EN 2346-005:2018en,fr,de01-februar-2018SIST EN 2346-005:2018SLOVENSKI
STANDARDSIST EN 2346-005:20141DGRPHãþD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 2346-005
November
t r s y ICS
v {ä r x r Supersedes EN
t u v xæ r r wã t r s uEnglish Version
Aerospace series æ Cableá electricalá fire resistant æ Operating temperatures between æ x w
¹C and
t x r
¹C æ Part
r r wã DW familyá single UV laser printable and multicore assembly æ Light weight æ Product standard Série aérospatiale æ Câbles électriques résistant au feu æTempératures de fonctionnement comprises entre æ x w
¹C et
t x r
¹C æ Partie
r r w ã Famille DWá fil simple marquable au laser UV et éléments assemblés æ Version allégée æ Norme de produit
Luftæ und Raumfahrt æ Feuerbeständige elektrische Leitungen æ Betriebstemperaturen zwischen æ x w
¹C und
t x r
¹C æ Teil
r r wã DWæFamilieá einadrigeá UVæLaser bedruckbará und mehradrige Leitungen æ Gewichtsoptimiert æ Produktnorm This European Standard was approved by CEN on
t u July
t r s yä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Serbiaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
t r s y CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
t u v xæ r r wã t r s y ESIST EN 2346-005:2018
Single core is UV laser printable in accordance with EN 3838; UV laser markability is not mandatory for multicore cables. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 2234, Aerospace series — Cable, electrical, fire resistant — Technical specification EN 2346-002, Aerospace series — Cable, electrical, fire resistant — Operating temperatures between − 65 °C and 260 °C — Part 002: General
EN 3475 (all parts), Aerospace series — Cables, electrical, aircraft use — Test methods
EN 3838, Aerospace series — Requirements and tests on user-applied markings on aircraft electrical cables
EN 4608-001, Aerospace series — Cable, electrical, fire resistant — Single and twisted multicore assembly, screened (braided) and jacketed — Operating temperatures between – 65 °C and 260 °C — Part 001: Technical specification
EN 9133, Aerospace series — Quality Management Systems — Qualification Procedure for Aerospace Standard Products IEC 28:1925, Inter
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.