ASTM C739-08
(Specification)Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation
Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation
ABSTRACT
This specification covers the composition and physical requirements of chemically treated, recycled cellulosic fiber loose-fill type thermal insulation for installation in attics or enclosed spaces in housing and other buildings by pneumatic or pouring method. While the products are used in various constructions, they are adaptable primarily, but not exclusively, to wood joists, rafters, and stud constructions. The basic material shall be made from selected paper, paperboard stock, or ground wood stock, excluding contaminated materials, which may reasonably be expected to be retained in the finished product. Suitable chemicals are introduced to provide properties such as flame resistance, processing, and handling characteristics. Products shall be prepared suitably to undergo test methods, for which they should comply with the following physical and chemical property requirements: corrosiveness; critical radiant flux; fungi resistance; moisture vapor sorption; odor emission; smoldering combustion; and thermal resistance.
SCOPE
1.1 This specification covers the composition and physical requirements of chemically treated, recycled cellulosic fiber loose-fill type thermal insulation for use in attics or enclosed spaces in housing, and other framed buildings within the ambient temperature range from − 45 to 90°C by pneumatic or pouring application. While products that comply with this specification are used in various constructions, they are adaptable primarily, but not exclusively, to wood joist, rafters, and stud construction.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C739 – 08
Standard Specification for
1
Cellulosic Fiber Loose-Fill Thermal Insulation
This standard is issued under the fixed designation C739; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope C687 Practice for Determination of Thermal Resistance of
Loose-Fill Building Insulation
1.1 This specification covers the composition and physical
C1045 PracticeforCalculatingThermalTransmissionProp-
requirements of chemically treated, recycled cellulosic fiber
erties Under Steady-State Conditions
loose-fill type thermal insulation for use in attics or enclosed
C1114 Test Method for Steady-State Thermal Transmission
spaces in housing, and other framed buildings within the
Properties by Means of the Thin-Heater Apparatus
ambient temperature range from−45 to 90°C by pneumatic or
C1338 Test Method for Determining Fungi Resistance of
pouring application. While products that comply with this
Insulation Materials and Facings
specification are used in various constructions, they are adapt-
C1363 Test Method for Thermal Performance of Building
able primarily, but not exclusively, to wood joist, rafters, and
Materials and Envelope Assemblies by Means of a Hot
stud construction.
Box Apparatus
1.2 The values stated in SI units are to be regarded as
C1374 Test Method for Determination of Installed Thick-
standard. No other units of measurement are included in this
ness of PneumaticallyApplied Loose-Fill Building Insula-
standard.
tion
1.3 This standard does not purport to address all of the
C1485 Test Method for Critical Radiant Flux of Exposed
safety concerns, if any, associated with its use. It is the
Attic Floor Insulation Using an Electric Radiant Heat
responsibility of the user of this standard to establish appro-
Energy Source
priate safety and health practices and determine the applica-
E691 Practice for Conducting an Interlaboratory Study to
bility of regulatory limitations prior to use.
Determine the Precision of a Test Method
2. Referenced Documents E970 Test Method for Critical Radiant Flux of Exposed
2
AtticFloorInsulationUsingaRadiantHeatEnergySource
2.1 ASTM Standards:
B152/B152M Specification for Copper Sheet, Strip, Plate,
3. Terminology
and Rolled Bar
3.1 Definitions—For definitions of terms used in this speci-
C168 Terminology Relating to Thermal Insulation
fication, see Terminology C168.
C177 Test Method for Steady-State Heat Flux Measure-
3.2 Definitions of Terms Specific to This Standard:
ments and Thermal Transmission Properties by Means of
3.2.1 attic—an enclosed space between the roof and ceiling
the Guarded-Hot-Plate Apparatus
of the occupied part of a building.
C518 Test Method for Steady-State Thermal Transmission
3.2.2 critical radiant flux—thelevelofincidentradiantheat
Properties by Means of the Heat Flow Meter Apparatus
energy on the attic floor insulation system at the most distant
2
flame-out point (W/cm ).
1
This specification is under the jurisdiction of ASTM Committee C16 on
Thermal Insulation and is the direct responsibility of Subcommittee C16.23 on 4. Materials and Manufacture
Blanket and Loose Fill Insulation.
4.1 The basic material shall be recycled cellulosic fiber
Current edition approvedAug. 15, 2008. Published November 2008. Originally
´1
made from selected paper, paperboard stock, or ground wood
approved 1973. Last previous edition approved 2005 C739–05b . DOI: 10.1520/
C0739-08.
stock, excluding contaminated materials, which may reason-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
ablybeexpectedtoberetainedinthefinishedproduct.Suitable
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
chemicals are introduced to provide properties such as flame
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. resistance, processing, and handling characteristics.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C739 – 08
NOTE 2—The importance of an insulation’s product to maintain its fire
4.2 The basic material may be processed into a form
retardant characteristics is recognized. A task group in ASTM C16.31 is
suitable for installation by pneumatic or pouring methods.
currently studying methods to ascertain if there is a long-term deteriora-
5. Physical and Chemical Properties tion of fire performance characteristics of cellulose insulation. Should the
need for a permanency test be determ
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation:C739–05b Designation: C 739 – 08
Standard Specification for
1
Cellulosic Fiber Loose-Fill Thermal Insulation
This standard is issued under the fixed designation C739; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1
´ NOTE—Table3 was editorially corrected in May 2007.
1. Scope
1.1 Thisspecificationcoversthecompositionandphysicalrequirementsofchemicallytreated,recycledcellulosicfiberloose-fill
type thermal insulation for use in attics or enclosed spaces in housing, and other framed buildings within the ambient temperature
range from−45 to 90°C (−49 to 194°F) by pneumatic or pouring application. While products that comply with this specification
are used in various constructions, they are adaptable primarily, but not exclusively, to wood joist, rafters, and stud construction.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses No other units of measurement
are provided for information only. included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
B152152/B152M Specification for Copper Sheet, Strip, Plate, and Rolled Bar
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the
Guarded-Hot-Plate Apparatus
C518 TestMethodforSteady-StateHeatFluxMeasurementsandThermalTransmissionPropertiesbyMeansoftheHeatFlow
Meter Apparatus
C687 Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
C1045 Practice for Calculating Thermal Transmission Properties fromUnder Steady-State Conditions
C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus
C1374Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation
1338 Test Method for Determining Fungi Resistance of Insulation Materials and Facings
C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box
Apparatus
C1374 Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation
C1485 Test Method for Critical Radiant Flux of ExposedAttic Floor Insulation Using an Electric Radiant Heat Energy Source
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E970 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
3. Terminology
3.1 Definitions—For definitions of terms used in this specification, see Terminology C168.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 attic—an enclosed space between the roof and ceiling of the occupied part of a building.
3.2.2 critical radiant flux—the level of incident radiant heat energy on the attic floor insulation system at the most distant
2 2
flame-out point (W/cm (Btu/ft · s)). ).
1
ThisspecificationisunderthejurisdictionofASTMCommitteeC16onThermalInsulationandisthedirectresponsibilityofSubcommitteeC16.23onBlanketandLoose
Fill Insulation.
Current edition approved Nov. 15, 2005. Published December 2005. Originally approved 1973. Last previous edition approved 2005 C739–05a.
´1
Current edition approved Aug. 15, 2008. Published October 2008. Originally approved 1973. Last previous edition approved 2005 C739–05b .
2
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C739–08
4. Materials and Manufacture
4.1The4.1 The basic material shall be recycled cellulosic fiber made from selected paper, paperboard stock, or ground wood
stock, excluding contaminated materials, which may reason
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.