Standard Test Method for Vibratory Packing Density of Formed Catalyst Particles and Catalyst Carriers

SIGNIFICANCE AND USE
5.1 This test method is to be used for measuring the vibratory packing density of formed particles that will not break up during sampling, filling, or vibrating of the measuring cylinder under test conditions.
SCOPE
1.1 This test method covers the determination of the vibratory packing density of formed catalyst and catalyst carriers. For the purpose of this test, catalyst particles are defined as extrudates, spheres, or formed pellets of 0.8-mm to 4.8-mm (1/32-in. to 3/16-in.) nominal diameter.  
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Sep-2023
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D4180-23 - Standard Test Method for Vibratory Packing Density of Formed Catalyst Particles and Catalyst Carriers
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D4180-23 - Standard Test Method for Vibratory Packing Density of Formed Catalyst Particles and Catalyst Carriers
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D4180 − 23
Standard Test Method for
Vibratory Packing Density of Formed Catalyst Particles and
1
Catalyst Carriers
This standard is issued under the fixed designation D4180; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope E691 Practice for Conducting an Interlaboratory Study to
Determine the Precision of a Test Method
1.1 This test method covers the determination of the vibra-
E1272 Specification for Laboratory Glass Graduated Cylin-
tory packing density of formed catalyst and catalyst carriers.
ders
For the purpose of this test, catalyst particles are defined as
extrudates, spheres, or formed pellets of 0.8-mm to 4.8-mm
3. Terminology
1 3
( ⁄32-in. to ⁄16-in.) nominal diameter.
3.1 Definitions—See Terminology D3766.
1.2 The values stated in SI units are to be regarded as the
4. Summary of Test Method
standard. The values given in parentheses are for information
only.
4.1 A preconditioned sample of formed catalyst or catalyst
1.3 This standard does not purport to address all of the carrier is vibrated in a cylinder. The vibratory packing density
is determined from a known mass and vibrated volume.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
5. Significance and Use
priate safety, health, and environmental practices and deter-
5.1 This test method is to be used for measuring the
mine the applicability of regulatory limitations prior to use.
vibratory packing density of formed particles that will not
1.4 This international standard was developed in accor-
break up during sampling, filling, or vibrating of the measuring
dance with internationally recognized principles on standard-
cylinder under test conditions.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
6. Apparatus
mendations issued by the World Trade Organization Technical
6.1 Glass Cylinders, capacity 250 mL, feed and measuring,
Barriers to Trade (TBT) Committee.
conforming to Specification E1272, Class A.
2. Referenced Documents 3
6.2 Vibrator, conventional handheld, with hard rubber or
2
2.1 ASTM Standards:
metal impactor.
B215 Practices for Sampling Metal Powders
6.3 Feed Funnel, plastic, glass, or metal as shown in Fig. 1.
D3766 Terminology Relating to Catalysts and Catalysis
6.4 Ring Stand, Vibrator Holder and Clamps as shown in
E105 Guide for Probability Sampling of Materials
Figs. 2 and 3.
E122 Practice for Calculating Sample Size to Estimate, With
Specified Precision, the Average for a Characteristic of a
6.5 Desiccator, with a desiccant grade molecular sieve such
Lot or Process
as a No. 4A.
E177 Practice for Use of the Terms Precision and Bias in
6.6 Balance having sensitivity of 0.1 g.
ASTM Test Methods
6.7 Drying Oven.
E456 Terminology Relating to Quality and Statistics
7. Sampling
1
This test method is under the jurisdiction of ASTM Committee D32 on 7.1 Test sample(s) shall be obtained from larger composites
Catalysts and is the direct responsibility of Subcommittee D32.02 on Physical-
by riffling or splitting in accordance with subsection 5.12 of
Mechanical Properties.
Current edition approved Oct. 1, 2023. Published October 2023. Originally
3
approved in 1988. Last previous edition approved in 2018 as D4180 – 13 (2018). The sole source of supply of the vibrator known to the committee at this time
DOI: 10.1520/D4180-23. is Wahl Clipper Corp., Sterling, IL. Model 4120 used at low speed is recommended
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or to replace Model 4180, which is discontinued. If you are aware of alternative
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM suppliers, please provide this information to ASTM International Headquarters.
Standards volume information, refer to the standard’s Document Summary page on Your comments will receive careful consideration at a meeting of the responsible
1
the ASTM website. technical committee, which you may attend.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D4180 − 23
8.4 Transfer all the catalyst to the measuring cylinder at a
uniform rate not less than 2 mL/s or exceeding 3 mL/s. The
entire transfer time should be between 83 s and 125 s.
8.5 After an additional 60 s turn off vibrat
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D4180 − 13 (Reapproved 2018) D4180 − 23
Standard Test Method for
Vibratory Packing Density of Formed Catalyst Particles and
1
Catalyst Carriers
This standard is issued under the fixed designation D4180; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the determination of the vibratory packing density of formed catalyst and catalyst carriers. For the
1
purpose of this test, catalyst particles are defined as extrudates, spheres, or formed pellets of 0.80.8-mm to 4.8-mm ( ⁄32-in. to
3
⁄16-in.) nominal diameter.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
B215 Practices for Sampling Metal Powders
D3766 Terminology Relating to Catalysts and Catalysis
E105 Guide for Probability Sampling of Materials
E122 Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or
Process
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
E456 Terminology Relating to Quality and Statistics
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E1272 Specification for Laboratory Glass Graduated Cylinders
3. Terminology
3.1 Definitions—See Terminology D3766.
1
This test method is under the jurisdiction of ASTM Committee D32 on Catalysts and is the direct responsibility of Subcommittee D32.02 on Physical-Mechanical
Properties.
Current edition approved May 1, 2018Oct. 1, 2023. Published May 2018October 2023. Originally approved in 1988. Last previous edition approved in 20132018 as
D4180 – 13.D4180 – 13 (2018). DOI: 10.1520/D4180-13R18.10.1520/D4180-23.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D4180 − 23
4. Summary of Test Method
4.1 A preconditioned sample of formed catalyst or catalyst carrier is vibrated in a cylinder. The vibratory packing density is
determined from a known mass and vibrated volume.
5. Significance and Use
5.1 This test method is to be used for measuring the vibratory packing density of formed particles that will not break up during
sampling, filling, or vibrating of the measuring cylinder under test conditions.
6. Apparatus
6.1 Glass Cylinders, capacity 250 mL, feed and measuring, conforming to Specification E1272, Class A.
3
6.2 Vibrator, conventional handheld, with hard rubber or metal impactor.
6.3 Feed Funnel, plastic, glass, or metal as shown in Fig. 1.
6.4 Ring Stand, Vibrator Holder and Clamps as shown in Figs. 2 and 3.
6.5 Desiccator, with a desiccant grade molecular sieve such as a No. 4A.
6.6 Balance having sensitivity of 0.1 g.
6.7 Drying Oven.
7. Sampling
7.1 Test sample(s) shall be obtained from larger composites by riffling or splitting in accordance with subsection 5.12 of STP
4
447A with the aim of obtaining a representative sample that mirrors the shape and size distribution of the larger composite. Guide
E105 provides guidance on constructing a sampling plan and Practice E122 assists the analyst with determining the representative
sample size. The analyst is also urged to consult Practice B215 which contains excellent sampling guidance.
FIG. 1 Feed Funnel
3
The sole source of supply of the vibrator known to the committee at this ti
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.