ASTM C1522-05(2013)
(Test Method)Standard Test Method for Extensibility After Heat Aging of Cold Liquid-Applied Elastomeric Waterproofing Membranes
Standard Test Method for Extensibility After Heat Aging of Cold Liquid-Applied Elastomeric Waterproofing Membranes
SIGNIFICANCE AND USE
6.1 This test method is used to determine a membrane's ability to bridge a crack that forms after the membrane has been applied and allowed to cure.
SCOPE
1.1 This test method describes a laboratory procedure for determining extensibility for one- or two-component cold liquid-applied elastomeric waterproofing membranes.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1522 −05 (Reapproved 2013)
Standard Test Method for
Extensibility After Heat Aging of Cold Liquid-Applied
Elastomeric Waterproofing Membranes
This standard is issued under the fixed designation C1522; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 5. Summary of Test Method
1.1 This test method describes a laboratory procedure for 5.1 Thistestmethodconsistsofpreparingthreesamples,for
determining extensibility for one- or two-component cold eachmembranetobetested,andextendingafteraging14days
liquid-applied elastomeric waterproofing membranes. at 70 6 2°C (158 6 3.6°F).
1.2 The values stated in SI units are to be regarded as the
6. Significance and Use
standard. The values in parentheses are for information only.
6.1 This test method is used to determine a membrane’s
1.3 Thecommitteewithjurisdictionoverthisstandardisnot
ability to bridge a crack that forms after the membrane has
aware of any comparable standards published by other orga-
been applied and allowed to cure.
nizations.
7. Apparatus
1.4 This standard does not purport to address all of the
7.1 Forced Draft Oven, controlled to 70 6 2°C (158 6
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- 3.6°F).
priate safety and health practices and determine the applica-
7.2 Three Mortar Test Blocks, dimensions 12 × 76 × 152
bility of regulatory limitations prior to use.
1 1
mm ( ⁄2×3×6 in.) nominal with 6 mm ( ⁄4 in.) deep notch cut
across the width (see Fig. 1).
2. Referenced Documents
7.3 Masking Tape.
2.1 ASTM Standards:
7.4 Sand.
C717Terminology of Building Seals and Sealants
C1250TestMethodforNonvolatileContentofColdLiquid-
7.5 Wood Board, Steel Wedge, Hammer, and Wood Blades.
Applied Elastomeric Waterproofing Membranes
7.6 Testing Machine,withtensiongripscapableofpullingat
C1375Guide for Substrates Used in Testing Building Seals
a rate of separation of 12.7 mm (0.5 in.)/min.
and Sealants
7.7 Vernier Calipers.
3. Terminology
8. Conditioning/Mixing
3.1 Definitions—Refer to Terminology C717 for definitions
8.1 Unless otherwise specified by those authorizing the test,
of terms used in this standard.
standardconditionsare23 61°C(73.4 61.8°F)and50 65%
relative humidity.
4. Comparison to Other Standards
8.2 Store all membrane materials to be tested in an un-
4.1 Thecommitteewithjurisdictionoverthisstandardisnot
openedcontaineratstandardconditionsforatleast24hbefore
aware of any comparable standards published by other orga-
any test specimens are prepared.
nizations.
8.3 Follow the manufacturer’s instructions for mixing and
preparing membrane materials for testing. Thoroughly stir
ThistestmethodisunderthejurisdictionofASTMCommitteeD08onRoofing
one-component materials before using. Mix two-component
and Waterproofing and is the direct responsibility of Subcommittee D08.22 on
compounds in the ratio recommended by the manufacturer. If
Waterproofing and Dampproofing Systems.
required by the manufacturer, mix each component prior to the
Current edition approved May 1, 2013. Published May 2013. Originally
approved in 2002. Last previous edition approved in 2005 as C1522–05. DOI: final mix.
10.1520/C1522-05R13.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or 9. Procedure
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
9.1 Prepare three test specimens for each membrane to be
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. tested as follows:
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
C1522−05 (2013)
FIG. 1Test Block for Testing Extensibility After Heat Aging
9.1.1 Cut each of the three mortar slabs crosswise in the 9.1.5 Forself-levelingmembranematerials,laytheslabson
centerofthe152mm(6in.)lengthtoadepthof6mm( ⁄4in.),
a bed of sand and level them.
as shown in Fig. 1.
NOTE 2—For self-leveling membranes, apply 50 mm (1 in.) wide
NOTE 1—Mortar substrates must
...







Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.