ASTM D1725-12(2019)
(Practice)Standard Practice for Preparing Resin Solutions for Viscosity Measurement by Bubble Time Method
Standard Practice for Preparing Resin Solutions for Viscosity Measurement by Bubble Time Method
ABSTRACT
This test method details the standard procedure for measuring the viscosity of resin solutions. The apparatuses required here are constant-temperature water bath, wide-mouthed screw capped bottles, cellophane sheets, No. 2 short taper corks, viscosity tube holder, bottle shaker, timing device, and viscosity tubes. Solid resins are dissolved in organic solvents by cold-cut or hot-cut methods in the laboratory. The viscosity of such prepared solutions, or of commercial solutions of resins is then determined by the bubble time method. The bubble seconds are approximately equal to stokes.
SCOPE
1.1 This practice provides instructions for preparing resin solutions viscosity measurement by bubble time method.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
- Status
- Published
- Publication Date
- 31-May-2019
- Technical Committee
- D01 - Paint and Related Coatings, Materials, and Applications
- Drafting Committee
- D01.33 - Polymers and Resins
Relations
- Effective Date
- 01-Jun-2019
- Effective Date
- 01-Sep-2018
- Effective Date
- 01-May-2013
- Refers
ASTM D1545-13 - Standard Test Method for Viscosity of Transparent Liquids by Bubble Time Method - Effective Date
- 01-Feb-2013
- Effective Date
- 01-Feb-2012
- Effective Date
- 01-Nov-2011
- Effective Date
- 01-Dec-2010
- Effective Date
- 01-Dec-2009
- Effective Date
- 01-Oct-2008
- Refers
ASTM D1545-07 - Standard Test Method for Viscosity of Transparent Liquids by Bubble Time Method - Effective Date
- 01-Jul-2007
- Effective Date
- 01-Nov-2005
- Effective Date
- 01-Sep-2005
- Effective Date
- 10-Dec-2001
- Effective Date
- 10-Dec-2001
- Effective Date
- 10-May-1999
Overview
ASTM D1725-12(2019), Standard Practice for Preparing Resin Solutions for Viscosity Measurement by Bubble Time Method, provides a systematic approach for preparing resin solutions to accurately measure viscosity using the bubble time method. Published by ASTM International, this standard ensures reliable and repeatable viscosity measurements, providing essential guidance for laboratories and industries working with resin solutions. The practice specifies the equipment needed, solution preparation techniques, and safety considerations, supporting consistency and quality in viscosity testing.
Key Topics
- Resin Solution Preparation: Outlines both cold-cut and hot-cut methods for dissolving solid resins in compatible organic solvents, ensuring complete solutions prior to viscosity measurement.
- Apparatus Requirements: Describes the essential equipment, including constant-temperature baths, screw-capped bottles, cellophane sheets, viscosity tube holders, bottle shakers, timing devices, and standardized viscosity tubes.
- Viscosity Measurement: Uses the bubble time method, where the time for an air bubble to rise through a specific distance of resin solution is recorded as an indicator of viscosity. Bubble seconds are approximately equivalent to stokes, enabling practical viscosity assessment.
- Solution Parameters: Emphasizes the importance of consistent solution concentration, solvent choice, and method (hot-cut or cold-cut), as viscosity results depend on these variables and should be mutually agreed upon by relevant parties.
- Precision and Repeatability: The procedure requires repeated measurements, with guidelines for acceptable repeatability to ensure reliability across different laboratories and batches.
Applications
- Quality Control in Manufacturing: Critical for producers of paints, coatings, adhesives, and resins that require consistent viscosity for application and performance.
- Laboratory Testing: Widely used in research and development laboratories evaluating resin behavior in solution, particularly for hydrocarbon resins and related polymer materials.
- Product Specification Compliance: Facilitates agreement between manufacturers and purchasers on resin solution viscosity, helping avoid disputes and establishing common quality metrics.
- Comparison of Resin Batches: Enables the reliable evaluation and comparison of commercial resin solutions, as well as the formulation of custom resin blends or modifications.
- Industrial Standards and Protocols: Supports the establishment of standardized methods in industry, reducing variability and uncertainty in viscosity measurements.
Related Standards
- ASTM D1545 - Test Method for Viscosity of Transparent Liquids by Bubble Time Method: The core reference for the bubble time measurement technique used with solutions prepared per ASTM D1725.
- ASTM D6440 - Terminology Relating to Hydrocarbon Resins: Provides important definitions relevant to the materials covered by ASTM D1725.
- ASTM E691 - Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method: Offers guidance for validating the repeatability and reproducibility of viscosity measurements.
- OSHA Regulations (29 CFR 1910.1000 & 1910.1200): Cited for safety and handling of laboratory chemicals and solvents in the preparation of resin solutions.
Practical Value
The ASTM D1725-12(2019) standard enhances the reliability and comparability of viscosity measurements for resin solutions, a key parameter affecting product performance and processing. Its step-by-step procedures, coupled with precise apparatus specifications and safety instructions, help ensure uniformity across the resin industry. By following this standard, organizations can achieve better quality control, meet regulatory demands, and establish trusted product benchmarks across national and international markets.
Keywords: resin solution viscosity, bubble time method, ASTM D1725, laboratory testing, viscosity measurement, standard practice, quality control, resin preparation, polymer solutions, industrial standards.
Buy Documents
ASTM D1725-12(2019) - Standard Practice for Preparing Resin Solutions for Viscosity Measurement by Bubble Time Method
Frequently Asked Questions
ASTM D1725-12(2019) is a standard published by ASTM International. Its full title is "Standard Practice for Preparing Resin Solutions for Viscosity Measurement by Bubble Time Method". This standard covers: ABSTRACT This test method details the standard procedure for measuring the viscosity of resin solutions. The apparatuses required here are constant-temperature water bath, wide-mouthed screw capped bottles, cellophane sheets, No. 2 short taper corks, viscosity tube holder, bottle shaker, timing device, and viscosity tubes. Solid resins are dissolved in organic solvents by cold-cut or hot-cut methods in the laboratory. The viscosity of such prepared solutions, or of commercial solutions of resins is then determined by the bubble time method. The bubble seconds are approximately equal to stokes. SCOPE 1.1 This practice provides instructions for preparing resin solutions viscosity measurement by bubble time method. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ABSTRACT This test method details the standard procedure for measuring the viscosity of resin solutions. The apparatuses required here are constant-temperature water bath, wide-mouthed screw capped bottles, cellophane sheets, No. 2 short taper corks, viscosity tube holder, bottle shaker, timing device, and viscosity tubes. Solid resins are dissolved in organic solvents by cold-cut or hot-cut methods in the laboratory. The viscosity of such prepared solutions, or of commercial solutions of resins is then determined by the bubble time method. The bubble seconds are approximately equal to stokes. SCOPE 1.1 This practice provides instructions for preparing resin solutions viscosity measurement by bubble time method. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D1725-12(2019) is classified under the following ICS (International Classification for Standards) categories: 87.060.20 - Binders. The ICS classification helps identify the subject area and facilitates finding related standards.
ASTM D1725-12(2019) has the following relationships with other standards: It is inter standard links to ASTM D1725-12, ASTM D6440-10(2018), ASTM E691-13, ASTM D1545-13, ASTM D1545-07(2012), ASTM E691-11, ASTM D6440-10, ASTM D154-85(2009), ASTM E691-08, ASTM D1545-07, ASTM E691-05, ASTM D6440-05, ASTM D6440-00A, ASTM D6440-01, ASTM E691-99. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ASTM D1725-12(2019) is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D1725 − 12 (Reapproved 2019)
Standard Practice for
Preparing Resin Solutions for Viscosity Measurement by
Bubble Time Method
This standard is issued under the fixed designation D1725; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2.2 Other Document:
OSHA Regulations, 29 CFR, paragraphs 19.10.1000 and
1.1 This practice provides instructions for preparing resin
1910.1200
solutions viscosity measurement by bubble time method.
1.2 The values stated in SI units are to be regarded as the
3. Terminology
standard. The values given in parentheses are for information
3.1 For definitions related to hydrocarbon resins see Termi-
only.
nology D6440.
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
4. Summary of Practice
responsibility of the user of this standard to establish appro-
4.1 Solid resins are dissolved in organic solvents by cold-
priate safety, health, and environmental practices and deter-
cut or hot-cut methods in the laboratory. The viscosity of such
mine the applicability of regulatory limitations prior to use.
prepared solutions, or of commercial solutions of resins is then
For specific hazard statements, see Section 7.
determined by the bubble time method (Test Method D1545).
1.4 This international standard was developed in accor-
The bubble seconds are approximately equal to stokes.
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the
5. Apparatus
Development of International Standards, Guides and Recom-
5.1 Bath, constant-temperature, consisting of a cylindrical
mendations issued by the World Trade Organization Technical
glass jar of about 5-gal capacity, or an aquarium tank with
Barriers to Trade (TBT) Committee.
controls capable of maintaining the temperature at 25 6 0.1°C
2. Referenced Documents with water as the bath medium.
2.1 ASTM Standards: 5.2 Bottles, 225-mL (8-oz), wide-mouth, screw cap.
D154 Guide for Testing of Varnishes (Withdrawn 2018)
5.3 Cellophane, sheet, cut into 102 or 127-mm (4 or 5-in.)
D1545 Test Method for Viscosity of Transparent Liquids by
squares.
Bubble Time Method
5.4 Corks, No. 2 short taper, to fit viscosity tubes.
D6440 Terminology Relating to Hydrocarbon Resins
E691 Practice for Conducting an Interlaboratory Study to 5.5 Holder for Viscosity Tubes, preferably a mechanical
Determine the Precision of a Test Method
holder withrackandpinionforinvertingthetubes.Theholder
should be checked with a small level and T-square to make
certain it holds the tubes in an exact vertical position after
This practice is under the jurisdiction of ASTM Committee D01 on Paint and being placed in the constant-temperature bath.
Related Coatings, Materials, and Applications and is the direct responsibility of
5.6 Bottle Shaker, preferably one which will give end-over-
Subcommittee D01.33 on Polymers and Resins.
Current edition approved June 1, 2019. Published June 2019. Originally end agitation.
approved in 1960. Last previous edition approved in 2012 as D1725 – 12. DOI:
10.1520/D1725–12R19.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM AvailablefromU.S.GovernmentPrintingOfficeSuperintendentofDocuments,
Standards volume information, refer to the standard’s Document Summary page on 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http://
the ASTM website. www.access.gpo.gov.
3 5
The last approved version of this historical standard is referenced on Suitable mechanical viscosity tube holders are available from various labora-
www.astm.org. tory supply companies.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D1725 − 12 (2019)
5.7 Timing Device, such as a stopwatch or electric stop possible as it is added. Place the cellophane sheet over the
clock capable of being read to a precision of 0.1 s. mouth of the bottle and screw on the cap tightly.
8.2.4 Immediately shake vigorously by hand and place on a
5.8 Viscosity Tubes, of clear glass and flat bottoms, having
shaker to give end-over-end agitation for an overnight period.
10.65 6 0.025-mm inside diameter and 114 6 1-mm outside
8.2.5 Check the weight of the bottle, cap, cellophane and
length. Plainly legible lines shall be located on the tubes as
solution to make certain that none was lost during the mixing.
follows:
If appreciable loss has occurred, discard the solution and
27±0.5mm
prepare a fresh one.
100 ± 0.5 mm
108 ± 0.5 mm
8.3 Hot-Cut Solutions:
All distances shall be measured from the bottom outside of
8.3.1 Prepare 100 g of solution as follows:Weigh a 250-mL
the tube. The distance between the first and second lines shall
Erlenmeyer flask with a ground joint to the nearest 0.05 g.
be 73 6 0.5 mm.
Weigh into the flask to the nearest 0.05 g the appropriate
amount of solvent (40 g for a 60 % solution).
6. Solvent
8.3.2 Weigh into the flask to the nearest 0.05 g the correct
6.1 The solvent used should be mutually agreed upon
amount (60 g for a 60 % solution) of the freshly crushed resin
between the purchaser and the manufacturer. Toluene, xylene,
passing a No. 10 (2000-
...