ASTM F949-09
(Specification)Standard Specification for Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a Smooth Interior and Fittings
Standard Specification for Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a Smooth Interior and Fittings
ABSTRACT
This specification covers the requirements, test methods, and materials for 4 to 36-in. diameter poly(vinyl chloride) (PVC) corrugated pipes, joints, and fittings that consist of an outer corrugated wall fused to a smooth inner wall, and are suitable for underground use in nonpressure applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage. When evaluated by the test procedures enumerated herein, the products shall conform to dimensional and performance requirements as specified for pipe stiffness, flattening resistance, impact strength, extrusion quality, heat reversion, bond strength, and joint tightness.
SCOPE
1.1 This specification covers requirements, test methods, and materials for 4 to 48 in. diameter poly(vinyl chloride) (PVC) corrugated pipe with a smooth interior. This profile wall pipe consists of an outer corrugated wall fused to a smooth inner wall providing pipe stiffness levels of 46 psi and 115psi. Joints and fittings are included in this specification.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use in nonpressure applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage.
Note 1—Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority, since chemicals not commonly found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.
1.3 Pipe and fittings produced to this specification shall be installed in accordance with Practice D 2321.
Note 2—For perforated pipe applications, the size of the embedment zone and permeability of the embedment material are important to the system's ability to provide the desired level of infiltration or exfiltration. The gradation of the embedment material must be compatible with the perforation slot size to avoid backfill migration into the pipe.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information.
An American National Standard
Designation: F949 – 09
Standard Specification for
Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a
1
Smooth Interior and Fittings
ThisstandardisissuedunderthefixeddesignationF949;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* 2. Referenced Documents
2
1.1 This specification covers requirements, test methods, 2.1 ASTM Standards:
and materials for 4 to 48 in. diameter poly(vinyl chloride) D618 Practice for Conditioning Plastics for Testing
(PVC)corrugatedpipewithasmoothinterior.Thisprofilewall D1600 Terminology for Abbreviated Terms Relating to
pipe consists of an outer corrugated wall fused to a smooth Plastics
inner wall providing pipe stiffness levels of 46 psi and 115psi. D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
Joints and fittings are included in this specification. Compounds and Chlorinated Poly(Vinyl Chloride)
1.2 The requirements of this specification are intended to (CPVC) Compounds
provide pipe and fittings suitable for underground use in D2122 Test Method for Determining Dimensions of Ther-
nonpressureapplicationsforsanitarysewers,stormsewers,and moplastic Pipe and Fittings
perforated and unperforated pipes for subdrainage. D2152 Test Method for Adequacy of Fusion of Extruded
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
NOTE 1—Industrial waste disposal lines should be installed only with
Acetone Immersion
the specific approval of the cognizant code authority, since chemicals not
D2321 Practice for Underground Installation of Thermo-
commonly found in drains and sewers and temperatures in excess of
140°F (60°C) may be encountered. plastic Pipe for Sewers and Other Gravity-Flow Applica-
tions
1.3 Pipe and fittings produced to this specification shall be
D2412 Test Method for Determination of External Loading
installed in accordance with Practice D2321.
Characteristics of Plastic Pipe by Parallel-Plate Loading
NOTE 2—For perforated pipe applications, the size of the embedment
D2444 Test Method for Determination of the Impact Resis-
zone and permeability of the embedment material are important to the
tance of Thermoplastic Pipe and Fittings by Means of a
system’s ability to provide the desired level of infiltration or exfiltration.
Tup (Falling Weight)
The gradation of the embedment material must be compatible with the
D2564 Specification for Solvent Cements for Poly(Vinyl
perforation slot size to avoid backfill migration into the pipe.
Chloride) (PVC) Plastic Piping Systems
1.4 The values stated in inch-pound units are to be regarded
D2855 Practice for Making Solvent-Cemented Joints with
as standard. The values given in parentheses are mathematical
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
conversions to SI units that are provided for information only
D3034 Specification for Type PSM Poly(Vinyl Chloride)
and are not considered standard.
(PVC) Sewer Pipe and Fittings
1.5 The following precautionary caveat pertains only to the
D3212 Specification for Joints for Drain and Sewer Plastic
test method portion, Section 7, of this specification: This
Pipes Using Flexible Elastomeric Seals
standard does not purport to address all of the safety concerns,
F412 Terminology Relating to Plastic Piping Systems
if any, associated with its use. It is the responsibility of the user
F477 SpecificationforElastomericSeals(Gaskets)forJoin-
of this standard to establish appropriate safety and health
ing Plastic Pipe
practices and determine the applicability of regulatory limita-
F679 Specification for Poly(Vinyl Chloride) (PVC) Large-
tions prior to use.
Diameter Plastic Gravity Sewer Pipe and Fittings
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
2
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Aug. 1, 2009. Published August 2009. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1985. Last previous edition approved in 2006 as F949–06a. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/F0949-09. the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F949 – 09
F1057 Practice for Estimating the Quality of Extruded Poly uniform as commercially practical in color
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:F 949–06a Designation: F 949 – 09
Standard Specification for
Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a
1
Smooth Interior and Fittings
This standard is issued under the fixed designation F 949; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 Thisspecificationcoversrequirements,testmethods,andmaterialsfor4to36-in.48in.diameterpoly(vinylchloride)(PVC)
corrugated pipe with a smooth interior. This profile wall pipe consists of an outer corrugated wall fused to a smooth inner wall
providing pipe stiffness levels of 46 psi and 115psi. Joints and fittings are included in this specification.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use in nonpressure
applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage.
NOTE 1—Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority, since chemicals not
commonly found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.
1.3 Pipe and fittings produced to this specification shall be installed in accordance with Practice D2321.
NOTE 2—For perforated pipe applications, the size of the embedment zone and permeability of the embedment material are important to the system’s
ability to provide the desired level of infiltration or exfiltration. The gradation of the embedment material must be compatible with the perforation slot
size to avoid backfill migration into the pipe.
1.4The values stated in inch-pound units are to be regarded as the standard. The values provided in parentheses are for
information purposes only.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 TestMethodforDeterminationoftheImpactResistanceofThermoplasticPipeandFittingsbyMeansofaTup(Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D2855 Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings
D3034 Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Aug. 1, 2006.2009. Published August 2006.2009. Originally approved in 1985. Last previous edition approved in 2006 as F949–06a.
2
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:F 949–06a Designation: F 949 – 09
Standard Specification for
Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a
1
Smooth Interior and Fittings
This standard is issued under the fixed designation F 949; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 Thisspecificationcoversrequirements,testmethods,andmaterialsfor4to36-in.48in.diameterpoly(vinylchloride)(PVC)
corrugated pipe with a smooth interior. This profile wall pipe consists of an outer corrugated wall fused to a smooth inner wall
providing pipe stiffness levels of 46 psi and 115psi. Joints and fittings are included in this specification.
1.2 The requirements of this specification are intended to provide pipe and fittings suitable for underground use in nonpressure
applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage.
NOTE 1—Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority, since chemicals not
commonly found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.
1.3 Pipe and fittings produced to this specification shall be installed in accordance with Practice D2321.
NOTE 2—For perforated pipe applications, the size of the embedment zone and permeability of the embedment material are important to the system’s
ability to provide the desired level of infiltration or exfiltration. The gradation of the embedment material must be compatible with the perforation slot
size to avoid backfill migration into the pipe.
1.4The values stated in inch-pound units are to be regarded as the standard. The values provided in parentheses are for
information purposes only.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 TestMethodforDeterminationoftheImpactResistanceofThermoplasticPipeandFittingsbyMeansofaTup(Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D2855 Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings
D3034 Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Aug. 1, 2006.2009. Published August 2006.2009. Originally approved in 1985. Last previous edition approved in 2006 as F949–06a.
2
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.