Standard Test Method for Measuring the Light Penetration of a Rolled Erosion Control Product (RECP)

SIGNIFICANCE AND USE
5.1 Light penetration may be used to control the quality of many RECPs. Light penetration has not been proven to relate to field performance for all materials.  
5.2 The light penetration of RECPs may vary considerably, depending on the composite materials used in the matrix of the mat or due to inconsistency within a given mat. To minimize variation, specific sample size and procedures are indicated in this test method to help ensure comparable results.  
5.3 This test method may be used to determine the effect of different composite materials and makeup of RECPs on the penetration of light.  
5.4 This test method may be used for acceptance testing of commercial shipments of RECPs. Comparative tests as directed in 5.4.1 may be advisable.  
5.4.1 In case of a dispute arising from differences in reported test results when using this test method for acceptance testing of commercial shipments, the purchaser and the supplier should conduct comparative tests to determine if there is a statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. At a minimum, the two parties should take a group of test specimens that are as homogeneous as possible and that are formed from a lot of material of the type in question. The test specimens should be randomly assigned in equal numbers to each laboratory for testing. The average results from the two laboratories should be compared using Student’s t-test for unpaired data and an acceptable probability level chosen by the two begun. If bias is found, either its cause must be corrected, or the purchaser and supplier must agree upon the known bias.
Note 1: The light penetration has no definitive relationship to the amount of ground cover provided by a RECP, as the amount of light penetration may include light passing through translucent elements or light deflecting off of elements of the RECP structure. Thus, this test method is not intended to be used to determine a...
SCOPE
1.1 This test method covers measuring the amount of incandescent light that penetrates through a rolled erosion control product.  
1.2 This test method does not provide light penetration values for RECPs under variable normal sun and soil conditions. This test method determines nominal light penetration.  
1.3 This test method is not to be used to determine a percent ground cover value for RECPs, as the amount of light penetration may include light passing through translucent material or reflecting off surfaces.  
1.4 The values stated as a percentage are to be regarded as the standard. The values provided in footcandles are for information only.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-May-2018
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6567-18 - Standard Test Method for Measuring the Light Penetration of a Rolled Erosion Control Product (RECP)
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D6567-18 - Standard Test Method for Measuring the Light Penetration of a Rolled Erosion Control Product (RECP)
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ASTM D6567-18 - Standard Test Method for Measuring the Light Penetration of a Rolled Erosion Control Product (RECP)
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D6567 − 18
Standard Test Method for
Measuring the Light Penetration of a Rolled Erosion Control
1
Product (RECP)
This standard is issued under the fixed designation D6567; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D4439 Terminology for Geosynthetics
E177 Practice for Use of the Terms Precision and Bias in
1.1 This test method covers measuring the amount of
ASTM Test Methods
incandescent light that penetrates through a rolled erosion
E691 Practice for Conducting an Interlaboratory Study to
control product.
Determine the Precision of a Test Method
1.2 This test method does not provide light penetration
values for RECPs under variable normal sun and soil condi-
3. Terminology
tions. This test method determines nominal light penetration.
3.1 Definitions:
1.3 This test method is not to be used to determine a percent
3.1.1 light penetration, n—the percent of light incident on
ground cover value for RECPs, as the amount of light
the front surface of a material that is emitted from the back
penetration may include light passing through translucent
surface of the material.
material or reflecting off surfaces.
3.2 For definitions of other textile terms used in this test
1.4 The values stated as a percentage are to be regarded as
method, refer to Terminology D123.
the standard. The values provided in footcandles are for
3.3 For definitions of other terms relating to geotextiles and
information only.
geomembranes used in this test method, refer to Terminology
1.5 This standard does not purport to address all of the
D4439.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
4. Summary of Test Method
priate safety, health, and environmental practices and deter-
4.1 The nominal light penetration of RECPs is determined
mine the applicability of regulatory limitations prior to use.
by the meter reading in footcandles with and without place-
1.6 This international standard was developed in accor-
ment of the specimen in a determined location between the
dance with internationally recognized principles on standard-
light source and the meter.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
5. Significance and Use
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
5.1 Light penetration may be used to control the quality of
many RECPs. Light penetration has not been proven to relate
2. Referenced Documents
to field performance for all materials.
2
2.1 ASTM Standards:
5.2 The light penetration of RECPs may vary considerably,
D123 Terminology Relating to Textiles
depending on the composite materials used in the matrix of the
D4354 Practice for Sampling of Geosynthetics and Rolled
mat or due to inconsistency within a given mat. To minimize
Erosion Control Products (RECPs) for Testing
variation, specific sample size and procedures are indicated in
this test method to help ensure comparable results.
5.3 This test method may be used to determine the effect of
1
This test method is under the jurisdiction of ASTM Committee D35 on
different composite materials and makeup of RECPs on the
Geosynthetics and is the direct responsibility of Subcommittee D35.05 on Geosyn-
thetic Erosion Control.
penetration of light.
Current edition approved June 1, 2018. Published June 2018. Originally
5.4 This test method may be used for acceptance testing of
approved in 2000. Last previous edition approved in 2017 as D6567 – 17. DOI:
10.1520/D6567-18.
commercial shipments of RECPs. Comparative tests as di-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
rected in 5.4.1 may be advisable.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.4.1 In case of a dispute arising from differences in
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. reported test results when using this test method for acceptance
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6567 − 18
testing of commercial shipments, the purchaser and the sup- RECP material in place.Ameter with a digital readout such as
plier should conduct comparative tests to determine if there is Extech Instruments Model 4070
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D6567 − 17 D6567 − 18
Standard Test Method for
Measuring the Light Penetration of a Rolled Erosion Control
1
Product (RECP)
This standard is issued under the fixed designation D6567; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers measuring the amount of incandescent light that penetrates through a rolled erosion control product.
1.2 This test method does not provide light penetration values for RECPs under variable normal sun and soil conditions. This
test method determines nominal light penetration.
1.3 This test method is not to be used to determine a percent ground cover value for RECPs, as the amount of light penetration
may include light passing through translucent material or reflecting off surfaces.
1.4 The values stated as a percentage are to be regarded as the standard. The values provided in foot-candlesfootcandles are for
information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D123 Terminology Relating to Textiles
D4354 Practice for Sampling of Geosynthetics and Rolled Erosion Control Products (RECPs) for Testing
D4439 Terminology for Geosynthetics
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
3. Terminology
3.1 Definitions:
3.1.1 light penetration, n—the percent of light incident on the front surface of a material that is emitted from the back surface
of the material.
3.2 For definitions of other textile terms used in this test method, refer to Terminology D123.
3.3 For definitions of other terms relating to geotextiles and geomembranes used in this test method, refer to Terminology
D4439.
4. Summary of Test Method
4.1 The nominal light penetration of RECPs is determined by the meter reading in foot candles footcandles with and without
placement of the specimen in a determined location between the light source and the meter.
1
This test method is under the jurisdiction of ASTM Committee D35 on Geosynthetics and is the direct responsibility of Subcommittee D35.05 on Geosynthetic Erosion
Control.
Current edition approved July 1, 2017June 1, 2018. Published July 2017June 2018. Originally approved in 2000. Last previous edition approved in 20142017 as
D6567 – 14.D6567 – 17. DOI: 10.1520/D6567-17.10.1520/D6567-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6567 − 18
5. Significance and Use
5.1 Light penetration may be used to control the quality of many RECPs. Light penetration has not been proven to relate to field
performance for all materials.
5.2 The light penetration of RECPs may vary considerably, depending on the composite materials used in the matrix of the mat
or due to inconsistency within a given mat. To minimize variation, specific sample size and procedures are indicated in this test
method to help ensure comparable results.
5.3 This test method may be used to determine the effect of different composite materials and makeup of RECPs on the
penetration of light.
5.4 This test method may be used for acceptance testing of commercial shipments of RECPs. Comparative tests as directed in
5.4.1 may be advisable.
5.4.1 In case of a dispute arising from differences in reported test results when using this test method for acceptance testing
...

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D6567 − 18
Standard Test Method for
Measuring the Light Penetration of a Rolled Erosion Control
1
Product (RECP)
This standard is issued under the fixed designation D6567; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D4439 Terminology for Geosynthetics
E177 Practice for Use of the Terms Precision and Bias in
1.1 This test method covers measuring the amount of
ASTM Test Methods
incandescent light that penetrates through a rolled erosion
E691 Practice for Conducting an Interlaboratory Study to
control product.
Determine the Precision of a Test Method
1.2 This test method does not provide light penetration
values for RECPs under variable normal sun and soil condi-
3. Terminology
tions. This test method determines nominal light penetration.
3.1 Definitions:
1.3 This test method is not to be used to determine a percent
3.1.1 light penetration, n—the percent of light incident on
ground cover value for RECPs, as the amount of light
the front surface of a material that is emitted from the back
penetration may include light passing through translucent
surface of the material.
material or reflecting off surfaces.
3.2 For definitions of other textile terms used in this test
1.4 The values stated as a percentage are to be regarded as
method, refer to Terminology D123.
the standard. The values provided in footcandles are for
3.3 For definitions of other terms relating to geotextiles and
information only.
geomembranes used in this test method, refer to Terminology
1.5 This standard does not purport to address all of the
D4439.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
4. Summary of Test Method
priate safety, health, and environmental practices and deter-
4.1 The nominal light penetration of RECPs is determined
mine the applicability of regulatory limitations prior to use.
by the meter reading in footcandles with and without place-
1.6 This international standard was developed in accor-
ment of the specimen in a determined location between the
dance with internationally recognized principles on standard-
light source and the meter.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
5. Significance and Use
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
5.1 Light penetration may be used to control the quality of
many RECPs. Light penetration has not been proven to relate
2. Referenced Documents
to field performance for all materials.
2
2.1 ASTM Standards:
5.2 The light penetration of RECPs may vary considerably,
D123 Terminology Relating to Textiles
depending on the composite materials used in the matrix of the
D4354 Practice for Sampling of Geosynthetics and Rolled
mat or due to inconsistency within a given mat. To minimize
Erosion Control Products (RECPs) for Testing
variation, specific sample size and procedures are indicated in
this test method to help ensure comparable results.
5.3 This test method may be used to determine the effect of
1
This test method is under the jurisdiction of ASTM Committee D35 on
different composite materials and makeup of RECPs on the
Geosynthetics and is the direct responsibility of Subcommittee D35.05 on Geosyn-
thetic Erosion Control.
penetration of light.
Current edition approved June 1, 2018. Published June 2018. Originally
5.4 This test method may be used for acceptance testing of
approved in 2000. Last previous edition approved in 2017 as D6567 – 17. DOI:
10.1520/D6567-18.
commercial shipments of RECPs. Comparative tests as di-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
rected in 5.4.1 may be advisable.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.4.1 In case of a dispute arising from differences in
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. reported test results when using this test method for acceptance
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6567 − 18
testing of commercial shipments, the purchaser and the sup- RECP material in place. A meter with a digital readout such as
Extech Instruments Model 407026 Heavy Duty Light Meter is
plier should conduct comparative tests to determine if there is
3
recommended.
a statistical bias between their laboratories. Competent statis-
tical assistance is recommended for th
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.