ASTM D6831-05
(Test Method)Standard Test Method for Sampling and Determining Particulate Matter in Stack Gases Using an In-Stack, Inertial Microbalance
Standard Test Method for Sampling and Determining Particulate Matter in Stack Gases Using an In-Stack, Inertial Microbalance
SCOPE
1.1 This test method describes the procedures for determining the mass concentration of particulate matter in gaseous streams using an automated, in-stack test method. This method, an in-situ, inertial microbalance, is based on inertial mass measurement using a hollow tube oscillator. This method is describes the design of the apparatus, operating procedure, and the quality control procedures required to obtain the levels of precision and accuracy stated.
1.2 This method is suitable for collecting and measuring filterable particulate matter concentrations in the ranges 0.2 mg/m3 and above taken in effluent ducts and stacks.
1.3 This test method may be used for calibration of automated monitoring systems (AMS). If the emission gas contains unstable, reactive, or semi-volatile substances, the measurement will depend on the filtration temperature, and this method (and other in-stack methods) may be more applicable than out-stack methods for the calibration of automated monitoring systems.
1.4 This test method can be employed in sources having gas temperature up to 200C and having gas velocities from 3 to 27 m/s.
1.5 This test method includes a description of equipment and methods to be used for obtaining and analyzing samples and a description of the procedure used for calculating the results.
1.6 Stack temperatures limitation for this test method is approximately 200C (392F).
1.7 This test method may be also be limited from use in sampling gas streams that contain fluoride, or other reactive species having the potential to react with or within the sample train.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 6831 – 05
Standard Test Method for
Sampling and Determining Particulate Matter in Stack Gases
1
Using an In-Stack, Inertial Microbalance
This standard is issued under the fixed designation D 6831; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
1.1 This test method describes the procedures for determin- 2.1 ASTM Standards:
ing the mass concentration of particulate matter in gaseous D 1356 Terminology Relating to Atmospheric Sampling
streamsusinganautomated,in-stacktestmethod.Thismethod, and Analysis
an in-situ, inertial microbalance, is based on inertial mass D 3154 Test MethodAverageVelocity in a Duct (PitotTube
measurement using a hollow tube oscillator. This method is Method)
describes the design of the apparatus, operating procedure, and D 3685/D 3685M Test Methods for Sampling and Determi-
the quality control procedures required to obtain the levels of nation of Particulate Matter in Stack Gases
precision and accuracy stated. D 3796 Practice for Calibration of Type S Pitot Tubes
1.2 This method is suitable for collecting and measuring D 6331 Test Method for Determination of Mass Concentra-
filterable particulate matter concentrations in the ranges 0.2 tion of Particulate Matter from Stationary Sources at Low
3
mg/m and above taken in effluent ducts and stacks. Concentrations (Manual Gravimetric Method)
1.3 This test method may be used for calibration of auto-
3. Terminology
mated monitoring systems (AMS). If the emission gas contains
3.1 For definitions of terms used in this test method, refer to
unstable, reactive, or semi-volatile substances, the measure-
ment will depend on the filtration temperature, and this method Terminology D 1356.
3.2 Definition of terms specific to this standard:
(and other in-stack methods) may be more applicable than
out-stack methods for the calibration of automated monitoring 3.2.1 particulate matter—for solid particles of any shape,
structure, or density dispersed in the gas phase at flue gas
systems.
1.4 This test method can be employed in sources having gas temperature and pressure conditions.
3.2.1.1 Discussion—In accordance with the described test
temperatureupto200°Candhavinggasvelocitiesfrom3to27
method, all material that may be collected by filtration under
m/s.
1.5 This test method includes a description of equipment specified conditions and that remains upstream of the filter and
on the filter after drying under specified conditions are consid-
and methods to be used for obtaining and analyzing samples
and a description of the procedure used for calculating the ered to be particulate matter. For the purposes of this test
method,particulatematterisdefinedbygasbornematter(solid
results.
1.6 Stack temperatures limitation for this test method is or liquid) captured on or in the filter after drying and weighing
in accordance with this test method.
approximately 200°C (392°F).
1.7 This test method may be also be limited from use in 3.2.2 in-stack, inertial microbalance—a mechanical oscilla-
tor constructed of a hollow tube of a specific metal alloy and
sampling gas streams that contain fluoride, or other reactive
species having the potential to react with or within the sample fitted with a filter cartridge that is designed to oscillate at a
frequency that is proportional to the mass of the hollow tube
train.
1.8 This standard does not purport to address all of the oscillator plus the mass of its filter cartridge.
3.2.3 mass transducer—the mass transducer is a principle
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- component of an in-stack inertial, microbalance. The mass
transducer provides the mechanical structure to support and
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. contain the hollow tube oscillator and to support the sample
inlet nozzle fixture, source gas temperature thermocouple, and
1
This test method is under the jurisdiction of ASTM Committee D22 on Air
2
Quality and is the direct responsibility of Subcommittee D22.03 on Ambient For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Atmospheres and Source Emissions. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Current edition approved June 1, 2005. Published June 2005. Originally Standards volume information, refer to the standard’s Document Summary page on
approved in 2002. Last previous edition approved in 2002 as D 6831 - 02. the ASTM website.
Copyright © ASTM International,
...
Questions, Comments and Discussion