Standard Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes

ABSTRACT
This specification includes the requirements for mixing rooms where paste and mortar specimens are prepared and for moist cabinets, moist rooms, and water storage tanks where paste, mortar, and concrete specimens are stored; intended for use in the testing of hydraulic cements and concretes. The system shall be equipped with a temperature recorder and a reference temperature measuring device that are to be placed practically near to each other. The air and mixing water temperatures and the relative humidity in the cement mixing room shall be maintained at specific values. Moist cabinets and moist rooms shall be constructed of durable materials with tight-fitting doors or windows for all openings. Air in moist cabinet or moist room shall be saturated with moisture in order to provide specified storage conditions and air temperature shall be controlled with provisions made for heating, cooling, or both. The specified relative humidity in these systems shall be maintained by the use of one or more fog sprays, water sprays, or curtains of water on the inner walls. Water storage tanks shall be constructed of non-corroding materials with provisions for automatic control of water temperature. The water in a storage tank shall be saturated with calcium hydroxide to prevent leaching.
SCOPE
1.1 This specification includes requirements for mixing rooms where paste and mortar specimens are prepared; and for moist cabinets, moist rooms, and water storage tanks where paste, mortar, and concrete specimens are stored.  
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and rounding given in Standard IEEE/ASTM SI 10, of measurements made in other units.  
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
14-Jun-2019
Technical Committee
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM C511-19 - Standard Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C511-19 - Standard Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C511 −19
Standard Specification for
Mixing Rooms, Moist Cabinets, Moist Rooms, and Water
Storage Tanks Used in the Testing of Hydraulic Cements
1
and Concretes
This standard is issued under the fixed designation C511; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* E77 Test Method for Inspection and Verification of Ther-
mometers
1.1 This specification includes requirements for mixing
C125 Terminology Relating to Concrete and Concrete Ag-
rooms where paste and mortar specimens are prepared; and for
gregates
moist cabinets, moist rooms, and water storage tanks where
C219 Terminology Relating to Hydraulic Cement
paste, mortar, and concrete specimens are stored.
IEEE/ASTM SI 10 Standard for Use of the International
1.2 The values stated in SI units are to be regarded as
System of Units (SI): The Modern Metric System
standard. No other units of measurement are included in this
standard. Values in SI units shall be obtained by measurement
3. Terminology
in SI units or by appropriate conversion, using the Rules for
3.1 Definitions:
Conversion and rounding given in Standard IEEE/ASTM SI
3.1.1 RefertoTerminologyC125andTerminologyC219for
10, of measurements made in other units.
definitions of terms used in this test method.
1.3 The text of this standard references notes and footnotes
3.2 Definitions of Terms Specific to This Standard:
which provide explanatory material. These notes and footnotes
3.2.1 mixing room, n—a room with controlled temperature
(excluding those in tables and figures) shall not be considered
and relative humidity where cement paste and mortar speci-
as requirements of this standard.
mens are prepared.
1.4 This standard does not purport to address all of the
3.2.2 moist cabinet, n—a compartmented storage facility of
safety concerns, if any, associated with its use. It is the
moderate dimensions with controlled temperature and relative
responsibility of the user of this standard to establish appro-
humidity.
priate safety, health, and environmental practices and deter-
3.2.3 moist room, n—a “walk-in” storage facility with
mine the applicability of regulatory limitations prior to use.
controlled temperature and relative humidity, commonly called
1.5 This international standard was developed in accor-
a fog room when the prescribed relative humidity is achieved
dance with internationally recognized principles on standard-
by the atomization of water.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
4. Requirements for Cement Mixing Rooms
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
4.1 The temperature of the air in the vicinity of the mixing
slab, molds, and base plates shall be maintained at 23.0 6
2. Referenced Documents
4.0 °C and at a relative humidity of not less than 50 %.
2
2.1 ASTM Standards:
4.2 The temperature of the mixing water used to prepare
C51 Terminology Relating to Lime and Limestone (as used
cement paste and mortar specimens shall be 23.0 6 2.0 °C.
by the Industry)
5. Temperature Measuring Devices
1
This specification is under the jurisdiction of ASTM Committee C01 on
Cement and is the direct responsibility of Subcommittee C01.95 on Coordination of
5.1 Reference Temperature Measuring Device—used to
Standards.
verify the temperature recorder, must be accurate and readable
Current edition approved June 15, 2019. Published June 2019. Originally
to 0.5 ºC. A copy of the certificate or report which verifies the
approved in 1968. Last previous edition approved in 2013 as C511 – 13. DOI:
10.1520/C0511-19. accuracy shall be available in the laboratory.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
NOTE 1—The ice-point method described in Test Method E77 may be
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on used to ensure that no damage to the reference thermometer has occurred
the ASTM website. during shipping.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C511−19
5.2 Temperature Recorder—shall record temperatures every 6.1.1.2 Thermostatically control the space surrounding the
15 min or less and shall be accurate and readable to 1 ºC. The moist cabinet or moist room and manually control the tempera-
data from the recorder shall
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C511 − 13 C511 − 19
Standard Specification for
Mixing Rooms, Moist Cabinets, Moist Rooms, and Water
Storage Tanks Used in the Testing of Hydraulic Cements
1
and Concretes
This standard is issued under the fixed designation C511; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification includes requirements for mixing rooms where paste and mortar specimens are prepared; and for moist
cabinets, moist rooms, and water storage tanks where paste, mortar, and concrete specimens are stored.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
Values in SI units shall be obtained by measurement in SI units or by appropriate conversion, using the Rules for Conversion and
rounding given in Standard IEEE/ASTM SI 10, of measurements made in other units.
1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C51 Terminology Relating to Lime and Limestone (as used by the Industry)
E77 Test Method for Inspection and Verification of Thermometers
C125 Terminology Relating to Concrete and Concrete Aggregates
C219 Terminology Relating to Hydraulic Cement
IEEE/ASTM SI 10 Standard for Use of the International System of Units (SI): The Modern Metric System
3. Terminology
3.1 Definitions:
3.1.1 Refer to Terminology C125 and Terminology C219 for definitions of terms used in this test method.
3.2 Definitions:Definitions of Terms Specific to This Standard:
3.2.1 mixing room, n—a room with controlled temperature and relative humidity where cement paste and mortar specimens are
prepared.
3.2.2 moist cabinet, n—a compartmented storage facility of moderate dimensions with controlled temperature and relative
humidity.
3.2.3 moist room, n—a “walk-in” storage facility with controlled temperature and relative humidity, commonly called a fog
room when the prescribed relative humidity is achieved by the atomization of water.
1
This specification is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.95 on Coordination of Standards.
Current edition approved Dec. 1, 2013June 15, 2019. Published January 2014June 2019. Originally approved in 1968. Last previous edition approved in 20092013 as
C511C511 – 13.–09. DOI: 10.1520/C0511-13.10.1520/C0511-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C511 − 19
4. Requirements for Cement Mixing Rooms
4.1 The temperature of the air in the vicinity of the mixing slab, molds, and base plates shall be maintained at 23.0 6 4.0 °C
4.0 °C and at a relative humidity of not less than 50 %.
4.2 The temperature of the mixing water used to prepare cement paste and mortar specimens shall be 23.0 6 2.0 °C.
5. Temperature Measuring Devices
5.1 Reference Temperature Measuring Device—used to verify the temperature recorder, must be accurate and readable to 0.5
ºC. A copy of the certificate or report which verifies the accuracy shall be available in the laboratory.
NOTE 1—The ice-point method described in Test Method E
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.