Standard Practice for Basic Functional Stability of a Mechanical Pump Dispenser

SIGNIFICANCE AND USE
3.1 This practice is used for determining the accelerated usage of a mechanical pump dispenser for consumer usage.
SCOPE
1.1 This practice covers the determination of the basic functional stability of a mechanical pump dispenser with a product.  
1.2 This practice covers accelerated usage evaluations of mechanical pump dispensers (spray or flow types) with a product.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.Specific precautions are given in Section 5.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Apr-2018
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6633-18 - Standard Practice for Basic Functional Stability of a Mechanical Pump Dispenser
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D6633-18 - Standard Practice for Basic Functional Stability of a Mechanical Pump Dispenser
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D6633 − 18
Standard Practice for
1
Basic Functional Stability of a Mechanical Pump Dispenser
This standard is issued under the fixed designation D6633; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3. Significance and Use
3.1 This practice is used for determining the accelerated
1.1 This practice covers the determination of the basic
usage of a mechanical pump dispenser for consumer usage.
functional stability of a mechanical pump dispenser with a
product.
4. Apparatus
1.2 This practice covers accelerated usage evaluations of
4.1 Containers, that will allow the mechanical pump dis-
mechanical pump dispensers (spray or flow types) with a penser to be affixed to them (Note 1) and also be capable of
containing product for a period of time at various environmen-
product.
tal conditions (Note 2).
1.3 This standard does not purport to address all of the
NOTE 1—If possible, the actual container to be marketed should be
safety concerns, if any, associated with its use. It is the
used.
responsibility of the user of this standard to establish appro-
4.2 Product, a sufficient amount to fill the number of
priate safety, health, and environmental practices and deter-
containers in accordance with 4.1, reference 10.2.
mine the applicability of regulatory limitations prior to us-
e.Specific precautions are given in Section 5.
4.3 Balance, with direct reading to 0.01 g. Top loading or
1.4 This international standard was developed in accor- analytical style is recommended.
dance with internationally recognized principles on standard-
4.4 Environments, where the mechanical pump dispenser
ization established in the Decision on Principles for the
and product will be kept during the test period.
Development of International Standards, Guides and Recom-
4.4.1 Ambient Area, maintained at 23 6 3°C (73 6 5.4°F).
mendations issued by the World Trade Organization Technical
4.4.2 Oven (45°C) , maintained at 45 6 3°C (113 6 5.4°F).
Barriers to Trade (TBT) Committee.
NOTE 2—The oven temperature can be changed according to product
formulation. If different temperatures are used, this should be noted in the
2. Referenced Documents
test report discussed in 11.
2
4.4.3 Cycle Chamber, optional, alternating 5 to 50°C (41 to
2.1 ASTM Standards:
122°F) every 24 h.
D2063 Test Methods for Measurement of Torque Retention
for Packages with Continuous Thread Closures
4.5 Oven-Safe Tray, with absorbent paper towels laid in the
D3890 Test Method for Number of Strokes to Prime a
tray.
Mechanical Pump Dispenser
4.6 Food Coloring or Dye, optional.
D4336 Test Methods for Determination of the Output Per
Stroke of a Mechanical Pump Dispenser 5. Precautions
E122 Practice for Calculating Sample Size to Estimate,With
5.1 Appropriate handling considerations should be given to
Specified Precision, the Average for a Characteristic of a
flammable, toxic, caustic, or other potentially hazardous ma-
Lot or Process
terial used. When testing at any temperature, safety should be
the number one consideration and special attention should be
used on the flash points of the products tested.
1
This practice is under the jurisdiction of ASTM Committee F02 on Primary
6. Sampling
Barrier Packaging and is the direct responsibility of Subcommittee F02.30 on
Mechanical Dispensers.
6.1 Based upon the desired precision, sampling shall be
Current edition approved May 1, 2018. Published June 2018. Originally
performed in accordance with Practice E122.
approved in 2001. Last previous edition approved in 2010 as D6633 – 05(2010).
DOI: 10.1520/D6633-18.
6.2 In the absence of any special sampling plan, perfor-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
mance shall be based on not less than the number of represen-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
tative specimens exposed to any of the environmental condi-
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. tions as specified in Section 9.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6633 − 18
7. Test Specimen 10.5 For trigger sprayers, remove all of the test specimens
from their respective environments once every two weeks for
7.1 Test specimens shall be clean, dry and previously
a duration of 12 weeks for a total
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D6633 − 05 (Reapproved 2010) D6633 − 18
Standard Test Method Practice for
1
Basic Functional Stability of a Mechanical Pump Dispenser
This standard is issued under the fixed designation D6633; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method practice covers the determination of the basic functional stability of a mechanical pump dispenser with a
product.
1.2 This test method practice covers accelerated usage evaluations of mechanical pump dispensers (spray or flow types) with
a product.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.Specific precautions are given in Section 5.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D2063 Test Methods for Measurement of Torque Retention for Packages with Continuous Thread Closures
D3890 Practice for Number of Strokes to Prime a Mechanical Pump Dispenser
D4336 Practice for Determination of the Output Per Stroke of a Mechanical Pump Dispenser
E122 Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or
Process
3. Significance and Use
3.1 This test method practice is used for determining the accelerated usage of a mechanical pump dispenser for consumer usage.
4. Apparatus
4.1 Containers, that will allow the mechanical pump dispenser to be affixed to them (Note 1) and also be capable of containing
product for a period of time at various environmental conditions (Note 2).
NOTE 1—If possible, the actual container to be marketed should be used.
4.2 Product, a sufficient amount to fill the number of containers in accordance with 4.1, reference 10.2.
4.3 Balance, with direct reading to 0.01 g. Top loading or analytical style is recommended.
4.4 Environments, where the mechanical pump dispenser and product will be kept during the test period.
4.4.1 Ambient Area, maintained at 23 6 3°C (73 6 5.4°F).
4.4.2 Oven (45°C) , maintained at 45 6 3°C (113 6 5.4°F).
NOTE 2—The oven temperature can be changed according to product formulation. If different temperatures are used, this should be noted in the test
report discussed in 11.
4.4.3 Cycle Chamber, optional, alternating 5 to 50°C (41 to 122°F) every 24 h.
1
This test method practice is under the jurisdiction of ASTM Committee F02 on FlexiblePrimary Barrier Packaging and is the direct responsibility of Subcommittee F02.30
on Mechanical Pump Dispensers.
Current edition approved Oct. 1, 2010May 1, 2018. Published March 2011June 2018. Originally approved in 2001. Last previous edition approved in 20052010 as
D6633 – 05.D6633 – 05(2010). DOI: 10.1520/D6633-05R10.10.1520/D6633-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6633 − 18
4.5 Oven-Safe Tray, with absorbent paper towels laid in the tray.
4.6 Food Coloring or Dye, optional.
5. Precautions
5.1 Appropriate handling considerations should be given to flammable, toxic, caustic, or other potentially hazardous material
used. When testing at any temperature, safety should be the number one consideration and special attention should be used on the
flash points of the products tested.
6. Sampling
6.1 Based upon the desired precision, sampling shall be performed in accordance with Practice E122.
6.2 In the absence of any special sampling plan, performance shall be based on not less than the number of representative
specimens exposed to any of the environmental
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.