This European Standard establishes the principles and basic methodology of a formal system of biocontamination control in Cleanrooms and associated controlled environments. These principles are based on establishing control and then on demonstrating control.
This standard specifies the methods required for assessing risk monitoring risk zones in a consistent way and for applying control measures appropriate to the degree of risk involved.
It will also give guidance on the assessment and verifi...
view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      75 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      55 pages
      English language
    • e-Library read for
      1 day

This document provides test methods in support of the operation for cleanrooms and clean zones to meet air cleanliness classification, other cleanliness attributes and related controlled conditions. Performance tests are specified for two types of cleanrooms and clean zones: those with unidirectional airflow and those with non-unidirectional airflow, in three possible occupancy states: as-built, at-rest and operational. The test methods, recommended test apparatus and test procedures for determi...view more

    • sale 10% off
    • Standard
      60 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      79 pages
      English language
    • e-Library read for
      1 day

This document provides test methods in support of the operation for cleanrooms and clean zones to meet air cleanliness classification, other cleanliness attributes and related controlled conditions.
Performance tests are specified for two types of cleanrooms and clean zones: those with unidirectional airflow and those with non-unidirectional airflow, in three possible occupancy states: as-built, at-rest and operational.
The test methods, recommended test apparatus and test procedures for deter...
view more

    • sale 10% off
    • Standard
      60 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      79 pages
      English language
    • e-Library read for
      1 day

This document provides test methods in support of the operation for cleanrooms and clean zones to meet air cleanliness classification, other cleanliness attributes and related controlled conditions. Performance tests are specified for two types of cleanrooms and clean zones: those with unidirectional airflow and those with non-unidirectional airflow, in three possible occupancy states: as-built, at-rest and operational. The test methods, recommended test apparatus and test procedures for determi...view more

    • sale 15% off
    • Standard
      52 pages
      English language
    • sale 15% off
    • Standard
      58 pages
      French language
    • sale 15% off
    • Standard
      59 pages
      French language
    • sale 15% off
    • Standard
      53 pages
      English language

This standard gives recommendations on reducing energy consumption and maintaining energy efficiency in new and existing cleanrooms and clean air devices, as classified by EN ISO 14644-1.

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day

This document gives guidance and recommendations for optimizing energy usage and maintaining energy efficiency in new and existing cleanrooms, clean zones and separative devices. It provides guidance for the design, construction, commissioning and operation of cleanrooms.
This document covers all cleanroom-specific features and can be used in different areas to optimize energy use in electronic, aerospace, nuclear, pharmaceutical, hospital, medical device, food industries and other clean air a...
view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day

This document gives guidance and recommendations for optimizing energy usage and maintaining energy efficiency in new and existing cleanrooms, clean zones and separative devices. It provides guidance for the design, construction, commissioning and operation of cleanrooms. This document covers all cleanroom-specific features and can be used in different areas to optimize energy use in electronic, aerospace, nuclear, pharmaceutical, hospital, medical device, food industries and other clean air app...view more

    • sale 15% off
    • Standard
      43 pages
      English language
    • sale 15% off
    • Standard
      46 pages
      French language

This document covers the monitoring of air cleanliness by particles in terms of concentration of airborne nanoscale particles. For monitoring purposes, only populations of particles with a lower size limit of 0.1 microns (100 nm) or less ? "nanoscale" ? are considered. The monitoring given in this document is for use mainly in "operational" states. NOTE 1 For the purposes of this document, reference is made to "nanoscale particles", which means all nano-objects having one (nanoplate), two (nanof...view more

    • sale 15% off
    • Standard
      11 pages
      English language

This document provides requirements and guidelines for assessing the chemical airborne cleanliness
of equipment and materials which are foreseen to be used in cleanrooms and associated controlled
environments which are linked to the ISO standard for cleanliness classes by chemical concentration
(see ISO 14644-8).
The following are outside the scope of this document:
— health and safety requirements;
— compatibility with cleaning agents and techniques;
— cleanability;
— biocontamination;
...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

ISO 14644-15:2017 provides requirements and guidelines for assessing the chemical airborne cleanliness of equipment and materials which are foreseen to be used in cleanrooms and associated controlled environments which are linked to the ISO standard for cleanliness classes by chemical concentration (see ISO 14644‑8).
The following are outside the scope of ISO 14644-15:2017:
- health and safety requirements;
- compatibility with cleaning agents and techniques;
- cleanability;
- biocontaminat...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

ISO 14644-15:2017 provides requirements and guidelines for assessing the chemical airborne cleanliness of equipment and materials which are foreseen to be used in cleanrooms and associated controlled environments which are linked to the ISO standard for cleanliness classes by chemical concentration (see ISO 14644‑8). The following are outside the scope of ISO 14644-15:2017: - health and safety requirements; - compatibility with cleaning agents and techniques; - cleanability; - biocontamination; ...view more

    • sale 15% off
    • Standard
      22 pages
      French language
    • sale 15% off
    • Standard
      21 pages
      English language

This part of ISO 14644 addresses the cleaning (removal of contaminants) to a specified degree on cleanroom surfaces, surfaces of equipment in the cleanroom and surfaces of materials in the cleanroom.
The following are excluded from this document:
• product and process cleaning;
• cleaning of microbiological contamination;
• detailed cleaning methods and procedures.
This part of ISO 14644 provides guidance about different cleaning techniques, classified, e.g. as wet/dry and physical/chemical.
Thi...
view more

    • sale 10% off
    • Standard
      43 pages
      English language
    • e-Library read for
      1 day

ISO 14644-13:2017 gives guidelines for cleaning to a specified degree on cleanroom surfaces, surfaces of equipment in a cleanroom and surfaces of materials in a cleanroom. Under consideration are all surfaces (external or internal) that are of interest. It provides guidance on the assessment of cleaning methods for achieving the required surface cleanliness by particle concentration (SCP) and surface cleanliness by chemical concentration (SCC) classes and which techniques should be considered to...view more

    • sale 10% off
    • Standard
      43 pages
      English language
    • e-Library read for
      1 day

ISO 14644-13:2017 gives guidelines for cleaning to a specified degree on cleanroom surfaces, surfaces of equipment in a cleanroom and surfaces of materials in a cleanroom. Under consideration are all surfaces (external or internal) that are of interest. It provides guidance on the assessment of cleaning methods for achieving the required surface cleanliness by particle concentration (SCP) and surface cleanliness by chemical concentration (SCC) classes and which techniques should be considered to...view more

    • sale 15% off
    • Standard
      34 pages
      English language
    • sale 15% off
    • Standard
      36 pages
      French language

This part of ISO 14644 specifies a methodology to assess the suitability of equipment (e.g. machinery,
measuring equipment, process equipment, components and tools) for use in cleanrooms and associated
controlled environments, with respect to airborne particle cleanliness as specified in ISO 14644-1.
Particle sizes range from 0,1 μm to equal to or larger than 5 μm (given in ISO 14644-1).
NOTE Where regulatory agencies impose supplementary guidelines or restrictions, appropriate adaptation
o...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

ISO 14644-14:2016 specifies a methodology to assess the suitability of equipment (e.g. machinery, measuring equipment, process equipment, components and tools) for use in cleanrooms and associated controlled environments, with respect to airborne particle cleanliness as specified in ISO 14644‑1. Particle sizes range from 0,1 µm to equal to or larger than 5 µm (given in ISO 14644‑1).
NOTE Where regulatory agencies impose supplementary guidelines or restrictions, appropriate adaptation of the ass...
view more

    • sale 10% off
    • Standard
      29 pages
      English language
    • e-Library read for
      1 day

ISO 14644-14:2016 specifies a methodology to assess the suitability of equipment (e.g. machinery, measuring equipment, process equipment, components and tools) for use in cleanrooms and associated controlled environments, with respect to airborne particle cleanliness as specified in ISO 14644‑1. Particle sizes range from 0,1 µm to equal to or larger than 5 µm (given in ISO 14644‑1). NOTE Where regulatory agencies impose supplementary guidelines or restrictions, appropriate adaptation of the asse...view more

    • sale 15% off
    • Standard
      21 pages
      English language
    • sale 15% off
    • Standard
      21 pages
      French language
    • sale 15% off
    • Standard
      21 pages
      English language
    • sale 15% off
    • Standard
      21 pages
      French language

This part of ISO 14644 specifies minimum requirements for a monitoring plan for cleanroom or clean
zone performance related to air cleanliness by particle concentration, based upon parameters that
measure or affect airborne particle concentration.
This part of ISO 14644 does not address condition monitoring of aspects such as vibration or general
maintenance of the engineering systems. It does not provide for monitoring of particle populations
that are outside the specified lower threshold ...
view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

This Part of this European Standard specifies the classification of particulate cleanliness for cleanrooms and clean air controlled spaces in three possible occupancy states according to the number concentration of airborne particulate matter present.

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day

ISO 14644-1:2015 specifies the classification of air cleanliness in terms of concentration of airborne particles in cleanrooms and clean zones; and separative devices as defined in ISO 14644‑7.
Only particle populations having cumulative distributions based on threshold (lower limit) particle sizes ranging from 0,1 µm to 5 µm are considered for classification purposes.
The use of light scattering (discrete) airborne particle counters (LSAPC) is the basis for determination of the concentration ...
view more

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day