This document specifies the particular requirements, including performance criteria for washerdisinfectors
(WD) that are intended to be used for cleaning and chemical disinfection of thermolabile
endoscopes.
This document also specifies the performance requirements for the cleaning and disinfection of the
washer-disinfector and its components and accessories which can be required to achieve the necessary
performance criteria.
The methods, instrumentation and instructions required for type ...
view more

    • sale 10% off
    • Standard
      95 pages
      English language
    • e-Library read for
      1 day

This document specifies the particular requirements, including performance criteria for washer-disinfectors (WD) that are intended to be used for cleaning and chemical disinfection of thermolabile endoscopes.
This document also specifies the performance requirements for the cleaning and disinfection of the washer-disinfector and its components and accessories which can be required to achieve the necessary performance criteria.
The methods, instrumentation and instructions required for type tes...
view more

    • sale 10% off
    • Standard
      95 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the performance requirements and test methods for small steam sterilizers and sterilization cycles which are used for medical purposes or for materials that are likely to come into contact with blood or body fluids.
This European Standard applies to automatically controlled small steam sterilizers that generate steam using electrical heaters or use steam that is generated by a system external to the sterilizer.
This European Standard applies to small steam ster...
view more

    • sale 10% off
    • Standard
      84 pages
      English language
    • e-Library read for
      1 day

This document specifies the particular requirements, including performance criteria for washer-disinfectors (WD) that are intended to be used for cleaning and chemical disinfection of thermolabile endoscopes. This document also specifies the performance requirements for the cleaning and disinfection of the washer-disinfector and its components and accessories which can be required to achieve the necessary performance criteria. The methods, instrumentation and instructions required for type testi...view more

    • sale 15% off
    • Standard
      81 pages
      English language
    • sale 15% off
    • Standard
      81 pages
      French language

This European Standard specifies the performance requirements and test methods for small steam sterilizers and sterilization cycles which are used for medical purposes or for materials that are likely to come into contact with blood or body fluids.
This European Standard applies to automatically controlled small steam sterilizers that generate steam using electrical heaters or use steam that is generated by a system external to the sterilizer.
This European Standard applies to small steam ster...
view more

    • sale 10% off
    • Standard
      84 pages
      English language
    • e-Library read for
      1 day

This part of ISO 15883 specifies the particular requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of re-usable items such as:
a) bedframes;
b) bedside tables;
c) transport carts;
d) containers;
e) surgical tables;
f) sterilization containers;
g) surgical clogs;
h) wheelchairs, aids for the disabled.
This Part of ISO 15883 also specifies the performance requirements for the cleaning and disinfection of the washe...
view more

    • sale 10% off
    • Standard
      47 pages
      English language
    • e-Library read for
      1 day

ISO 15883-7:2016 specifies the particular requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of reusable items such as the following:
a) bedframes;
b) bedside tables;
c) transport carts;
d) containers;
e) surgical tables;
f) sterilization containers;
g) surgical clogs;
h) wheelchairs, aids for the disabled.
ISO 15883-7:2016 also specifies the performance requirements for the cleaning and disinfection of ...
view more

    • sale 10% off
    • Standard
      47 pages
      English language
    • e-Library read for
      1 day

It specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. Examples of such equipment include the following: a) sterilizers and disinfectors using steam, and/or hot water as the sterilant; b) sterilizers and disinfectors using toxic gas, toxic aerosol or toxic vapour as the sterilant; c) sterilizers and di...view more

    • sale 10% off
    • Standard
      40 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and the relevant tests for large steam sterilizers primarily used in health care for the sterilization of medical devices and their accessories contained in one or more sterilization modules. The test loads described in this European Standard are selected to represent the majority of loads (i.e. wrapped goods consisting of metal, rubber and porous materials) for the evaluation of general purpose steam sterilizer for medical devices. However, specific...view more

    • sale 10% off
    • Standard
      102 pages
      English language
    • e-Library read for
      1 day

ISO 15883-7:2016 specifies the particular requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of reusable items such as the following: a) bedframes; b) bedside tables; c) transport carts; d) containers; e) surgical tables; f) sterilization containers; g) surgical clogs; h) wheelchairs, aids for the disabled. ISO 15883-7:2016 also specifies the performance requirements for the cleaning and disinfection of the washe...view more

    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 15% off
    • Standard
      32 pages
      French language
    • sale 15% off
    • Standard
      30 pages
      English language

This European Standard specifies requirements and the relevant tests for large steam sterilizers primarily used in health care for the sterilization of medical devices and their accessories contained in one or more sterilization modules. The test loads described in this European Standard are selected to represent the majority of loads (i.e. wrapped goods consisting of metal, rubber and porous materials) for the evaluation of general purpose steam sterilizers for medical devices. However, specifi...view more

    • sale 10% off
    • Standard
      102 pages
      English language
    • e-Library read for
      1 day

ISO 15883-6:2011 specifies particular requirements for washer-disinfectors (WDs) intended for use when the level of assurance of disinfection that is necessary can be achieved by cleaning and thermal disinfection (A0 not less than 60) and does not require an independent automated record of critical processes to be kept. It is intended to be used in conjunction with ISO 15883-1, which gives general requirements for WDs.
The range of products on which WDs of this particular type can be used is re...
view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

ISO 15883-6:2011 specifies particular requirements for washer-disinfectors (WDs) intended for use when the level of assurance of disinfection that is necessary can be achieved by cleaning and thermal disinfection (A0 not less than 60) and does not require an independent automated record of critical processes to be kept. It is intended to be used in conjunction with ISO 15883-1, which gives general requirements for WDs.
The range of products on which WDs of this particular type can be used is re...
view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

This part of ISO 15883 specifies general performance requirements for washer-disinfectors (WD) and their accessories that are intended to be used for cleaning and disinfection of re-usable medical devices and other articles used in the context of medical, dental, pharmaceutical and veterinary practice. It specifies performance requirements for cleaning and disinfection as well as for the accessories which can be required to achieve the necessary performance. The methods and instrumentation requi...view more

    • sale 10% off
    • Amendment
      16 pages
      English language
    • e-Library read for
      1 day

EN 14180 specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure only. These sterilizers are primarily used for the sterilization of heat labile medical devices in health care facilities. This European Standard specifies minimum requirements: - for the performance and design of sterilizers to ensure that the process is capable of sterilizing medical devices; - for the e...view more

    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day

EN 1422 specifies the requirements and the relevant tests for automatically controlled sterilizers employing ethylene oxide (EO) gas as the sterilant, either as a pure gas or a mixture with other gases, being used for the sterilization of medical devices and their accessories. This European Standard specifies requirements for ethylene oxide sterilizers (EO-sterilizers) working at super or sub-atmospheric pressure for: - the performance and design of sterilizers to ensure that the process is capa...view more

    • sale 10% off
    • Standard
      49 pages
      English language
    • e-Library read for
      1 day

2013-08-02 EMA: Draft for // vote received in ISO/CS (see notification of 2013-08-02 in dataservice).
2012-02-14 EMA: WI allocated to WG 8 as per TC secretary request.
2012-01-06 EMA: Draft for // ENQ received in ISO/CS (see notification of 2011-12-06 in dataservice).

    • sale 10% off
    • Amendment
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      6 pages
      French language
    • sale 15% off
    • Standard
      6 pages
      English language

This European Standard specifies the requirements and the relevant tests for automatically controlled sterilizers employing ethylene oxide (EO) gas as the sterilant, either as a pure gas or a mixture with other gases, being used for the sterilization of medical devices and their accessories.
This European Standard specifies requirements for ethylene oxide sterilizers (EO-sterilizers) working at super or sub-atmospheric pressure for:
- the performance and design of sterilizers to ensure that th...
view more

    • sale 10% off
    • Standard
      49 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure only.
These sterilizers are primarily used for the sterilization of heat labile medical devices in health care facilities.
This European Standard specifies minimum requirements:
- for the performance and design of sterilizers to ensure that the process is capable of sterilizing medical de...
view more

    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day