PT 62704-3 - Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz ? Part 3: Specific Requirements for using the Finite-Difference Time-Domain (FDTD) Method for SAR Calculations of Mobile Phones
- Abstract
To develop an international standard on the Specific Requirements for Finite Difference Time Domain (FDTD) Modelling of Exposure from mobile phones in order to calculate the Specific Absorption Rate (SAR) in the Human Body
- Slovenian
Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz ? Part 3: Specific Requirements for using the Finite-Difference Time-Domain (FDTD) Method for SAR Calculations of Mobile Phones
To develop an international standard on the Specific Requirements for Finite Difference Time Domain (FDTD) Modelling of Exposure from mobile phones in order to calculate the Specific Absorption Rate (SAR) in the Human Body
IEC/IEEE 62704-3:2017 defines the concepts, techniques, benchmark phone models, validation procedures, uncertainties and limitations of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in standardized head and body phantoms exposed to the electromagnetic fields generated by wireless communication devices, in particular pre-compliance assessment of mobile phones, in the frequency range from 30 MHz to 6 GHz. It recommends and provides guidance on the numerical modelling of mobile phones and benchmark results to verify the general approach for the numerical simulations of such devices. It defines acceptable modelling requirements, guidance on meshing and test positions of the mobile phone and the phantom models.
This document does not recommend specific SAR limits since these are found in other documents, e.g. IEEE C95.1-2005 and ICNIRP
Key words: Mobile Phone, Spatial-Average Specific Absorption Rate, Finite-Difference Time-Domain, Human Body
- Standard72 pagesEnglish and French languagesale 15% off
Frequently Asked Questions
PT 62704-3 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz ? Part 3: Specific Requirements for using the Finite-Difference Time-Domain (FDTD) Method for SAR Calculations of Mobile Phones" and is responsible for: To develop an international standard on the Specific Requirements for Finite Difference Time Domain (FDTD) Modelling of Exposure from mobile phones in order to calculate the Specific Absorption Rate (SAR) in the Human Body This committee has published 1 standards.
PT 62704-3 develops IEC standards in the area of Information technology. The scope of work includes: To develop an international standard on the Specific Requirements for Finite Difference Time Domain (FDTD) Modelling of Exposure from mobile phones in order to calculate the Specific Absorption Rate (SAR) in the Human Body Currently, there are 1 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.