IEC/SC 36C - IEC_SC_36C
Standardization of insulators for substations, and couplings of these insulators
IEC_SC_36C
Standardization of insulators for substations, and couplings of these insulators
General Information
This International Standard applies to composite hollow insulators consisting of a load-bearing insulating tube made of resin impregnated fibres, a housing (outside the insulating tube) made of elastomeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. The object of this standard is: To define the terms used; to prescribe test methods; and to prescribe acceptance criteria.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard applies to composite station post insulators consisting of a load bearing cylindrical insulating solid core made of resin impregnated fibres, a housing (outside the insulating solid core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings attached to the insulating core. Composite station post insulators covered by this standard are subjected to cantilever, torsion, tension and compression loads. They are intended for substations with a.c. voltages greater than 1 000 V up to 245 kV.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to ceramic and glass hollow insulators intended for general use in electrical equipment and ceramic hollow insulators intended for use with a permanent gas pressure in switchgear and controlgear. These insulators are intended for indoor and outdoor use in electrical equipment, operating on alternating current with a rated voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct-current equipment with a rated voltage of greater than 1 500 V.
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day
EN following parallel vote
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to post insulators of organic material for indoor service in electrical installations or equipment operating in air at atmospheric pressure on alternating current with a nominal voltage greater than 1 000 V up, but not including, 300 kV, as defined by range I of EN 60071-1, and a frequency not greater than 100 Hz. Composite insulators are not covered by this standard. The object of this standard is - to define the terms used, - define electrical and mechanical characteristics of post insulators of organic material and to prescribe the conditions under which the specified values of these characteristics are verified, - to prescribe methods of testing, - to prescribe acceptance criteria. This standard does not give numerical values for insulator characteristics, nor does it deal with a choice of insulators for specific operating conditions. HD 578 S1 specifies numerical values for electrical and mechanical characteristics and gives the dimensions necessary for interchangeability of post insulators.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
EN following parallel vote
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to post insulators and post insulator units of ceramic material or glass for indoor and outdoor service in electrical installations or equipment operating on alternating current with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. Notes: -May also be regarded as a provisional standard for insulators for use on d.c. systems, see IEC 60438. -When considering hollow insulators, see HD 329. -Tests on indoor post insulators of organic material will be covered by a future publication: Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV. -For artificial pollution and radio-interference tests, see EN 60437 and 60507. -For numerical values for insulator characteristics and for selection of insulators for specific operating conditions, see EN 60273.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to post insulators and post insulator units of ceramic material or glass intended for indoor or outdoor service, and to post insulators of organic material intended for indoor service in electrical installations or equipment operating on alternating current systems with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It may also be regarded as a provisional standard for insulators for use on direct current systems.
- Standardization document44 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to hollow insulators made of ceramic material, with their fixing devices, intended for use with a permanent gas pressure greater than 50 kPa gauge having an internal volume equal to or greater than 1 l (1 000 cm3). They are intended for use in electrical equipment operating on alternating current with a rated voltage greater than 1000 V and a frequency not greater than 100 Hz or for use in direct current equipment with a rated voltage greater than 1 500 V.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to insulating weather shields and containers made of ceramic material or glass before any metal fittings are attached intended for use in electrical equipment operating on d.c. or a.c., such as instrument transformers, lightning arresters. capacitors, bushings, cable sealing ends and circuit-breakers.
- Standardization document12 pagesEnglish languagesale 10% offe-Library read for1 day