CLC/TC 64/WG 23 - To be set up - Construction and demolition side installation - Restrictive conductive locations
HD 60364-7-704 - HD 60364- 7-706
To be set up - Construction and demolition side installation - Restrictive conductive locations
HD 60364-7-704 - HD 60364- 7-706
General Information
Frequently Asked Questions
CLC/TC 64/WG 23 is a Working Group within CLC. It is named "To be set up - Construction and demolition side installation - Restrictive conductive locations" and is responsible for: HD 60364-7-704 - HD 60364- 7-706 This committee has published 5 standards.
CLC/TC 64/WG 23 develops CLC standards in the area of W27 - ELECTRICAL INSTALLATIONS IN BUILDINGS - Information technology. The scope of work includes: HD 60364-7-704 - HD 60364- 7-706 Currently, there are 5 published standards from this working group.
CLC is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Working Group in CLC is a specialized group responsible for developing standards or technical work within a defined scope. These bodies bring together international experts to create consensus-based standards that support global trade, safety, and interoperability.
IEC 60364-7-7-704:2017(E) lays down requirements which apply to installations for construction and demolition sites for use during the period of the construction or demolition work which are intended to be taken out of service upon completion of the works. Examples include the following: - construction work of new buildings; - repair, alteration, extension or demolition of existing buildings or parts of existing buildings; - engineering works; - earthworks; - work of similar nature. The requirements apply to fixed or moveable installations. This new edition includes the following significant technical changes with respect to the previous edition: - clarification of the scope; - clarification of compliance with standards; - clarification of devices for isolation.
- Standardization document26 pagesEnglish languagee-Library read for1 day
The particular requirements of this part apply to fixed equipment in conducting locations where movement of persons is restricted by the location, and to supplies for portable equipment for use in such locations. A conducting location with restricted movement is comprised mainly of metallic or other conductive surrounding parts, within which it is likely that a person will come in contact through a substantial portion of his body with the metallic or other conductive surrounding parts and where the possibility of interrupting this contact is limited.
- Amendment11 pagesEnglish languagee-Library read for1 day
The particular requirements of this part apply to fixed equipment in conducting locations where movement of persons is restricted by the location, and to supplies for portable equipment for use in such locations. A conducting location with restricted movement is comprised mainly of metallic or other conductive surrounding parts, within which it is likely that a person will come in contact through a substantial portion of his body with the metallic or other conductive surrounding parts and where the possibility of interrupting this contact is limited.
- Standardization document6 pagesEnglish languagee-Library read for1 day
The special requirements of this part apply to temporary installations for construction and demolition sites during the period of the construction or demolition work, including for example the following: - construction work of new buildings; - repair, alteration, extension, demolition of existing buildings or parts of existing buildings; - engineering works; - earthworks; - work of similar nature. The requirements apply to fixed or moveable installations.
- Standardization document10 pagesEnglish languagee-Library read for1 day
- Standardization document11 pagesGerman languagee-Library read for1 day
- Standard – translation12 pagesSlovenian languagee-Library read for1 day