CLC/BTTF 146-1 - Losses of small transformers : methods of measurement, marking and other requirements related to eco-design regulation
To prepare a standard dealing with the measurement of the load and of the no load losses for general purpose small power transformers with a highest voltage for equipment not exceeding 1 kV, and other requirements related to eco design regulation.
Losses of small transformers : methods of measurement, marking and other requirements related to eco-design regulation
To prepare a standard dealing with the measurement of the load and of the no load losses for general purpose small power transformers with a highest voltage for equipment not exceeding 1 kV, and other requirements related to eco design regulation.
General Information
Frequently Asked Questions
CLC/BTTF 146-1 is a Technical Committee within CLC. It is named "Losses of small transformers : methods of measurement, marking and other requirements related to eco-design regulation" and is responsible for: To prepare a standard dealing with the measurement of the load and of the no load losses for general purpose small power transformers with a highest voltage for equipment not exceeding 1 kV, and other requirements related to eco design regulation. This committee has published 1 standards.
CLC/BTTF 146-1 develops CLC standards in the area of Z99 - UNDETERMINED - Information technology. The scope of work includes: To prepare a standard dealing with the measurement of the load and of the no load losses for general purpose small power transformers with a highest voltage for equipment not exceeding 1 kV, and other requirements related to eco design regulation. Currently, there are 1 published standards from this technical committee.
CLC is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in CLC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.
This European Standard gives Ecodesign requirements for small power transformers complying with the EN 61558 series and in relation to Commission Regulation (EU) N° 548/2014 implementing the European Directive 2009/125/EC. This European Standard is applicable to transformers with 50 Hz AC input and output with a rated power of 1 kVA or more and a voltage lower than 1 kV, except those excluded in the regulation. For transformers with a voltage between 1 kV and 1,1 kV, this standard may be used as a guide.
- Standard10 pagesEnglish languagee-Library read for1 day