CEN/TC 134/WG 3 - Plastics floor coverings
Preparation of draft standard test methods and specifcations in the field of plastics floor covering and contribution to the general standards of TC 134 via WG 6.
Plastics floor coverings
Preparation of draft standard test methods and specifcations in the field of plastics floor covering and contribution to the general standards of TC 134 via WG 6.
General Information
This European Standard specifies the characteristics for resilient floor coverings based upon synthetic thermoplastic polymers, supplied either in roll or tile form.
This specification does not apply to floor coverings specified in the series EN 649 to EN 654.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of floor coverings with sustainable enhanced slip resistant characteristics under specified conditions based on polyvinyl chloride and modifications thereof, supplied in either tile or roll form.
To encourage the consumer to make an informed choice, this European Standard includes a classification system (see EN 685) based on intensity of use, which shows where resilient floor coverings should give satisfactory service.
In addition, this European Standard details the requirements for the information to be included on the packaging labels.
The slip measurements are made in a laboratory on ex-factory floor covering surfaces only. The method described is suitable for testing on wet surfaces.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the minimum additional characteristics which are necessary for:
- polyvinyl chloride floor coverings in roll form according to EN 649, and
- polyvinyl chloride floor coverings with foam backing in roll form to EN 651
to be installed satisfactorily in special wet areas to form a watertight installation with a long life. It specifies two categories (A and B) for use on different substrates.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the mass per unit area of a reinforcement or backing of a polyvinyl chloride-based floor covering.
- Standard4 pagesEnglish languagesale 10% offe-Library read for1 day
To provide an informative annex that defines the precision of the test method according to interlaboratory trial results.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard describes the Stuttgart method for determining the wear resistance of the wear layer of polyvinyl chloride floor coverings under laboratory conditions. The method is applicable to polyvinyl chloride floor coverings with smooth surfaces. It can be used to determine the wear resistance of surfaces against abrasion and particularly for ranking different wear layer types within one type of product. It is not appropriate for comparing the wear resistance of different materials e.g. rubber and polyvinyl chloride.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of floor coverings based on polyvinyl chloride and modifications thereof, on jute or polyester backing or on polyester felt with polyvinyl chloride backing, supplied in either tile or roll form. To encourage the consumer to make an informed choice the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the characteristics of semi-flexible tiles based on polyvinyl chloride and modifications thereof. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of agglomerated cork with a wear layer based on polyvinyl chloride and modifications thereof. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the characteristics of semi-flexible tiles based on polyvinyl chloride and modifications thereof. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of floor coverings based on expanded (cushioned) polyvinyl chloride and modifications thereof supplied in either tile or roll form. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of homogeneous and heterogeneous floor coverings, based on polyvinyl chloride and modifications thereof, supplied in either tile or roll form. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of floor coverings based on polyvinyl chloride with polyvinyl chloride foam layer, supplied in either tile or roll form. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of floor coverings based on polyvinyl chloride and modifications thereof with a cork-based backing, supplied in either tile or roll form. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of floor coverings based on polyvinyl chloride with polyvinyl chloride foam layer, supplied in either tile or roll form. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics of homogeneous and heterogeneous floor coverings, based on polyvinyl chloride and modifications thereof, supplied in either tile or roll form. To encourage the consumer to make an informed choice, the standard includes a classification system (see EN 685) based on intensity of use, which shows where these floor coverings should give satisfactory service. It also specifies requirements for marking.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day