CEN/TC 135/WG 14 - Execution of aluminium structures and steel structures with cold formed structural sheeting
Execution of aluminium structures and steel structures with cold formed structural sheeting
General Information
This European Standard specifies requirements for the execution, i.e. the manufacture and the installation, of cold-formed structural steel members and sheeting and cold-formed structures for roof, ceiling, floor, wall and cladding applications.
This European Standard applies to structures designed according to the EN 1993 series.
This European Standard applies to structural members and sheeting to be designed according to EN 1993 1 3.
This European Standard may be used for structures designed according to other design rules provided that conditions for execution comply with them and any necessary additional requirements are specified.
This European Standard also specifies requirements for the execution i.e. the manufacture and the installation of structures made from cold formed profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading or seismic loading conditions and their documentation.
This European Standard covers sheeting of structural classes I and II according to EN 1993 1 3 used in structures.
This European Standard covers structural members of all structural classes according to EN 1993 1 3.
Structural sheeting are understood here to be:
- profiled sheet, such as trapezoidal, sinusoidal or liner trays (Figure 1), or
Structural members are understood here to be:
- members (linear profiled cross sections) that are produced by cold forming (Figure 2).
This European Standard also covers:
- not welded built-up sections (Figure 2b and 2c);
- cold-formed hollow sections including the welding of the longitudinal seam, not covered by EN 10219 1;
- perforated, punctured and micro profiled sheeting and members;
NOTE 1 Welded built-up sections, are not covered, the execution provisions are given in EN 1090–2.
This European Standard also covers spacer constructions between the outer and inner or upper and lower skins for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as all are involved in load transfer.
This European Standard covers steel profiled sheeting for composite floors, e.g. during installation and in stage of pouring concrete.
Composite structural members where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.
This European Standard does not cover the necessary analyses and detailing and execution rules for thermal insulation, moisture protection, noise control and fire protection.
This European Standard does not cover regulations of roof cladding and wall cladding, produced by traditional plumber methods or tinsmith methods.
Annex B of this standard concerns provisions which are not yet included in EN 1993 1 3. The guidelines in this annex may be wholly or partially superseded by future guidelines added to EN 1993.
This European Standard does not cover detailed requirements for water tightness or air permeability resistance and thermal aspects of sheeting.
NOTE 2 The structures covered in this standard can be for example
- single- or multi-skin roofs, whereby the load-bearing structure (lower skin) or the actual roof covering (upper skin) or both consist of cold-formed structural members and sheeting;
- single- or multi-skin walls whereby the load-bearing structure (inner skin), the actual cladding (outer skin) or both consist of cold-formed structural members and sheeting, or
- trusses from cold formed members.
NOTE 3 Structures can consist of an assembly of structural members and sheeting made of steel according to EN 1090–4 and of aluminium according to EN 1090-5.
- Standard91 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard96 pagesGerman languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures.
Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part.
Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas.
This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements.
A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply.
Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.
NOTE The structures covered in this standard can be for example
- single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements;
- single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or
- suspended ceilings for interior fitting.
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day