CEN/TC 50/WG 5 - Revision of product standards
Revision of all parts of EN 40
Revision of product standards
Revision of all parts of EN 40
General Information
Frequently Asked Questions
CEN/TC 50/WG 5 is a Working Group within the European Committee for Standardization (CEN). It is named "Revision of product standards" and is responsible for: Revision of all parts of EN 40 This committee has published 3 standards.
CEN/TC 50/WG 5 develops CEN standards in the area of Information technology. The scope of work includes: Revision of all parts of EN 40 Currently, there are 3 published standards from this working group.
The European Committee for Standardization (CEN) is a public standards organization that brings together the national standardization bodies of 34 European countries. CEN provides a platform for developing European Standards (ENs) and other technical documents in relation to various products, materials, services, and processes, supporting the European Single Market.
A Working Group in CEN is a specialized group responsible for developing standards or technical work within a defined scope. These bodies bring together international experts to create consensus-based standards that support global trade, safety, and interoperability.
This European Standard specifies the requirements for the verification of the design of lighting columns by calculation. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard. Fibre reinforced polymer composite lighting columns are covered in this standard in conjunction with EN 40-7.
This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767).
The calculations used in this European Standard are based on limit state principles, where the effects of factored loads are compared with the relevant resistance of the structure. Two limit states are considered:
a) the ultimate limit state, which corresponds to the load-carrying capacity of the lighting column;
b) the serviceability limit state, which relates to the deflection of the lighting column in service.
NOTE In following this approach, simplifications appropriate to lighting columns have been adopted, These are:
1) the calculations are applicable to circular and regular octagonal cross-sections;
2) the number of separate partial safety factors have been reduced to a minimum;
3) serviceability partial safety factors have a value equal to unity.
- Standard28 pagesEnglish languagee-Library read for1 day
This European Standard specifies design loads for lighting columns. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this standard. Fibre reinforced polymer composite lighting columns are covered in this document, in conjunction with Annex B of EN 40-7:2002.
This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767).
- Standard15 pagesEnglish languagee-Library read for1 day
This European Standard specifies the requirements for the verification of the design of steel, aluminium, concrete and fibre reinforced polymer composite lighting columns by testing. It gives type tests and so does not cover testing for quality control purposes. It applies to lighting columns of nominal height (including any bracket) not exceeding 20 m. Special structural designs to permit the attachment of signs, overhead wires, etc. are not covered by this European Standard.
This European Standard includes a simplified method for testing steel and aluminium lighting columns. Refer to EN 40-4 for concrete lighting columns and to EN 40-7 for fibre reinforced polymer composite lighting columns.
NOTE For a more detailed test procedure, refer to Annex D of EN 1990:2002.
The requirements for lighting columns made from materials other than concrete, steel, aluminium or fibre reinforced polymer composite (for example wood, plastic and cast iron) are not specifically covered in this European Standard.
This European Standard includes performance requirements for horizontal loads due to wind. Passive safety and the behaviour of a lighting column under the impact of a vehicle are not addressed. Such lighting columns will have additional requirements (see EN 12767).
- Standard14 pagesEnglish languagee-Library read for1 day