CEN/TC 72/WG 18 - Line-type heat detectors
Line-type heat detectors
General Information
This European Standard applies to non-resettable line-type heat detectors consisting of a sensing element using an electrical sensor cable which can be connected to a sensor control unit or either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works (see EN 54 1:2011).
The non-resettable sensing element has a fixed temperature alarm threshold and does not distinguish between short circuit and alarm condition.
This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of non-resettable line-type heat detectors to this European Standard.
This European Standard also covers non-resettable line-type heat detectors intended for use in the local protection of plant and equipment.
Non-resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this standard.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of resettable line-type heat detectors to this EN.
This European Standard also covers resettable line-type heat detectors intended for use in the local protection of plant and equipment.
Resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this EN.
This European Standard does not cover line-type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called digital systems).
- Standard74 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to Resettable Line type Heat Detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works.
This European Standard specifies the requirements and performance criteria, the corresponding test methods and the evaluation of conformity of the product to the standard.
This European Standard also covers Resettable Line type Heat Detectors intended for use in the local protection of plant and equipment.
Resettable Line type Heat Detectors with special characteristics and developed for specific risks are not covered by this standard.
This European Standard does not cover line-type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called "digital" systems).
- Draft82 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to non-resettable line type heat detectors consisting of a sensing element using an electrical sensor cable connected to a sensor control unit, either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in buildings and tunnels. The non-resettable sensing element has a fixed temperature alarm threshold and does not distinguish between short circuit and alarm condition. This standard also covers non-resettable line type heat detectors intended for use in the local protection of plants and machinery. Non-resettable line type heat detectors with special characteristics and developed for specific risks are not covered by this standard. This standard specifies the requirements and performance criteria. This standard specifies the corresponding test methods and the evaluation of conformity of the product to the standard.
- Draft65 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of resettable line-type heat detectors to this EN.
This European Standard also covers resettable line-type heat detectors intended for use in the local protection of plant and equipment.
Resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this EN.
This European Standard does not cover line-type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called digital systems).
- Draft12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to line type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in buildings and tunnels.
This standard also covers line type heat detectors intended for use in the local protection of plant and machinery.
Line type heat detectors with special characteristics and developed for specific risks are not covered by this standard.
This standard also does not cover line type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called "digital" systems).
This standard specifies the requirements and performance criteria. This standard specifies the corresponding test methods and the evaluation of conformity of the product to the standard.
- Draft73 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN 54-1:2011).
This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of resettable line-type heat detectors to this EN.
This European Standard also covers resettable line-type heat detectors intended for use in the local protection of plant and equipment.
Resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this EN.
This European Standard does not cover line-type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called digital systems).
- Standard83 pagesEnglish languagesale 10% offe-Library read for1 day